RESUMO
OBJECTIVES: The disposable esophagogastroduodenoscopy (EGD) system is a novel endoscopic device which is highly portable and is designed to eliminate the risk of cross-infection caused by reusable EGD. This study aimed to investigate the feasibility and safety of disposable EGD in emergency, bedside, and intraoperative settings. METHODS: This was a prospective, single-center, noncomparative study. Disposable EGD was used for emergency, bedside, and intraoperative endoscopies in 30 patients. The primary end-point was the technical success rate of the disposable EGD. Secondary end-points included technical performance indicators including clinical operability, image quality score, procedure time, the incidence of device malfunction and/or failure, and the incidence of adverse events. RESULTS: A total of 30 patients underwent diagnosis and/or treatment with disposable EGD. Therapeutic EGD was performed on 13/30 patients, including hemostasis (n = 3), foreign body retrieval (n = 6), nasoenteric tube placement (n = 3), and percutaneous endoscopic gastrostomy (n = 1). The technical success rate was 100%: all procedures and indicated interventions were completed without changing to a conventional upper endoscope. The mean image quality score obtained immediately after procedure completion was 3.72 ± 0.56. The mean (± SD) procedure time was 7.4 (± 7.6) min. There were no device malfunctions or failures, device-related adverse events, or overall adverse events. CONCLUSION: The disposable EGD may be a feasible alternative to the traditional EGD in emergency, bedside, and intraoperative settings. Preliminary data show that it is a safe and effective tool for diagnosis and treatment in emergency and bedside upper gastrointestinal cases. TRIAL REGISTRATION: Chinese Clinical Trial Registry (Trial ID: ChiCTR2100051452, https://www.chictr.org.cn/showprojen.aspx?proj=134284).
Assuntos
Endoscopia do Sistema Digestório , Endoscopia , Humanos , Projetos Piloto , Estudos Prospectivos , Endoscopia do Sistema Digestório/métodos , Intubação GastrointestinalRESUMO
To overcome difficulties in the removal of duodenal bulb lesions, especially those in anatomically challenging locations, we developed the endoscopic resection via antral submucosal tunneling (ERAST) technique. In this study, we evaluated the feasibility and safety of ERAST for the removal of superficial and subepithelial lesions in the duodenal bulb. This was a single-center retrospective study of 10 patients with lesions in the bulb. Submucosal tunneling from the gastric antrum to the duodenum was performed to facilitate en bloc tumor resection in the bulb. The en bloc resection rate, postoperative bleeding, and perforation were the primary endpoints. Ten lesions (four superficial and six subepithelial), with an average size of 19.1 ± 9.2 mm, were resected en bloc by ERAST. Esophagogastroduodenoscopy follow-up after 2 months indicated complete wound healing in all patients. In our primary experience, ERAST was found to be a feasible and safe endoscopic resection technique for the removal of lesions in the duodenal bulb, especially those that are difficult to access.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Gástricas , Duodeno/cirurgia , Ressecção Endoscópica de Mucosa/métodos , Endoscopia , Humanos , Estudos Retrospectivos , Neoplasias Gástricas/cirurgia , Resultado do TratamentoRESUMO
AIM: To compare feasibility and safety after gastrointestinal checkup by standing-type magnetically controlled capsule endoscopy (SMCE) and conventional gastroscopy. METHODS: This was a prospective multicenter, blinded study that compared SMCE with gastroscopy in patients from April 2018 to July 2018. All patients first underwent SMCE and then subsequently had gastroscopy with i.v. anesthesia. We calculated the compliance rates of gastric lesion detection by SMCE using gastroscopy as the standard. Capsule retention rate, incidence of adverse events, and patient satisfaction were documented throughout the study. RESULTS: One hundred and sixty-one patients who completed SMCE and gastroscopy were included in the analysis. Positive compliance rate among SMCE and gastroscopy was 92.0% (95% CI: 80.77%-97.78%). Negative compliance rate was 95.5% (89.80%, 98.52%). Moreover, overall compliance rate was 94.41% (89.65%, 97.41%). Sixty-four pathological outcomes were identified. Of these 64 outcomes, 50 were detected by both procedures. The gastroscopy method neglected seven findings (such as five erosions, one polyp, and one ulcer). Furthermore, SMCE also overlooked seven lesions (i.e. one erosion, two polyps, one atrophy, and three submucosal tumors). Capsule retention or related adverse events were not reported. CONCLUSION: Standing-type magnetically controlled capsule endoscopy provides equivalent agreement with gastroscopy and may be useful for screening of gastric illnesses without any anesthesia.
Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula/instrumentação , Gastroscopia , Magnetismo , Gastropatias/diagnóstico , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Preferência do Paciente , Método Simples-CegoRESUMO
OBJECTIVES: Flat colorectal adenomas have a high risk of malignancy; however, their detection is often difficult due to their flat morphology. In this retrospective, large-scale study, we investigated the prevalence and characteristics of flat adenomas in a population in China. METHODS: We analyzed the data collected for 16951 consecutive patients who underwent colonoscopy at four participating hospitals between September 2013 and September 2015. All colonoscopies were performed without magnification. RESULTS: Among the 1,6951 patients, 2938 (17.3%) had adenoma and 796 (4.7%) had flat adenomas. The detection of flat adenoma showed a weak correlation with the detection of adenoma (r = 0.666). Multivariable logistic regression analysis revealed the following independent factors influencing the detection of flat adenomas: patient-related factors of age, presence of warning symptoms, history of adenomas and bowel preparation as well as endoscopist-related factors of endoscopist's level of proficiency, number of colonoscopy operators and withdrawal time. CONCLUSIONS: The prevalence of flat adenomas in our study on Chinese patients was consistent with that reported from other countries. Factors conducive to the detection of flat adenomas were patient age of > 60 years, warning symptoms, history of adenoma, good bowel preparation, experienced endoscopist, single-operator colonoscopy and colonoscopy withdrawal time of >6 min.
Assuntos
Adenoma/diagnóstico por imagem , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Erros de Diagnóstico , Adenoma/epidemiologia , Adulto , Idoso , China/epidemiologia , Neoplasias Colorretais/epidemiologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prevalência , Estudos Retrospectivos , Fatores de Risco , Fatores de TempoRESUMO
AIMS: To evaluate the effectiveness and safety of endoscopic resection for gastric gastrointestinal stromal tumors (GISTs). MATERIAL AND METHODS: The effectiveness and safety of endoscopic resection were mainly assessed by complete resection rate, postoperative adverse event rate, and recurrence rate. Moreover, a comparison of endoscopic with laparoscopic resection for gastric GISTs was made through weighted mean difference by STATA 12.0 with regard to operation time, blood loss, and length of stay after including patients who underwent endoscopic or laparoscopic resection for gastric GISTs in the comparative studies. RESULTS: Eleven studies investigating endoscopic resection for GISTs were included. For stromal tumors <2 cm in average diameters the pooled rates of complete resection, postoperative adverse events and recurrence were 0.97, 0.08, and 0.03, respectively. Only five retrospective studies directly compared endoscopic with laparoscopic resection for gastric GISTs with average diameters from 1.1 cm to 3.8 cm, and endoscopic resection had a shorter operation time than laparoscopic resection, but there were no significant differences in intraoperative blood loss, length of stay, postoperative complications, and postoperative recurrence rates between the two approaches. CONCLUSIONS: Endoscopic resection is predominantly tried for gastric GISTs of relatively small size. It seems effective and safe for gastric GISTs <2 cm in average diameter, with relatively short operation times.
Assuntos
Gastrectomia/métodos , Tumores do Estroma Gastrointestinal/cirurgia , Neoplasias Gástricas/cirurgia , Gastroscopia , Humanos , Laparoscopia , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: Endoscopic submucosal tunneling dissection (ESTD) has been proved to be safe and effective for removal of esophageal submucosal tumors (SMTs) and can maintain the mucosal integrity compared with other endoscopic methods. The aim of the study was to estimate the safety and efficacy of ESTD as well as compare its efficacy with thoracoscopic enucleation for esophageal SMTs, which is used increasingly as a minimally invasive approach. METHODS: We retrospectively collected the clinical data of patients with esophageal SMTs <40 mm who underwent ESTD or thoracoscopic enucleation at Nanfang Hospital between January 2008 and August 2016. Epidemiologic data (sex, age), tumor location, tumor size, en bloc resection rate, adverse events, pathologic results, length of postoperative hospital stay, and cost were compared between ESTD and thoracoscopic enucleation. RESULTS: A total of 126 patients were included. A total of 74 patients underwent ESTD, and the other 52 underwent thoracoscopic enucleation. There was no significant difference between the 2 groups in sex, age, tumor size, hospitalization expense, infection, adverse events, and en bloc resection rate (P < .05). However, patients in the ESTD group had a shorter operating time, less estimated blood loss, shorter length of postoperative hospital stay, and lower chest pain level (P < .05). Kaplan-Meier curves for disease-free survival also showed no statistically significant difference between ESTD and thoracoscopic enucleation groups during the median follow-up of 19.5 and 42 months, respectively. CONCLUSIONS: The treatment efficacy was comparable between the ESTD and thoracoscopic enucleation for esophageal SMTs <40 mm. However, there was a significant advantage in the ESTD group for a shorter operating time, reduced postoperative chest pain, and shorter hospitalization.
Assuntos
Ressecção Endoscópica de Mucosa/métodos , Neoplasias Esofágicas/cirurgia , Esofagoscopia/métodos , Tumores do Estroma Gastrointestinal/cirurgia , Leiomioma/cirurgia , Toracoscopia/métodos , Adulto , Perda Sanguínea Cirúrgica , Dor no Peito , Intervalo Livre de Doença , Neoplasias Esofágicas/patologia , Feminino , Tumores do Estroma Gastrointestinal/patologia , Humanos , Estimativa de Kaplan-Meier , Leiomioma/patologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Dor Pós-Operatória , Estudos Retrospectivos , Infecção da Ferida Cirúrgica , Resultado do Tratamento , Carga TumoralRESUMO
OBJECTIVE: Patency capsule (PC) is a tool to screen the patency of the gastrointestinal (GI) tract. Capsule endoscopy can be performed after the patency is confirmed by the patency capsule. We aimed to estimate the diagnostic value of PC based on the existing trials. METHODS: We searched PubMed, CENTRAL and EMBASE for studies that included patients with suspected small bowel stricture who were evaluated by both PC and a reference standard (following capsule endoscopy and/or surgical pathology and/or endoscopic findings) and who were eligible for inclusion. The quality of the eligible studies was assessed using the Quality Assessment for Diagnostic Accuracy Studies-2 criteria. Sensitivity, specificity, likelihood ratios and the area under the receiver operating characteristic curve (AUROC) were calculated. RESULTS: Five studies including 203 patients fulfilled the eligibility criteria. The pooled data showed a PC sensitivity of 97% (95% CI 93-99%) and a specificity of 83% (95% CI 65-94%). The AUROC was 0.9557. CONCLUSIONS: PC may be of diagnostic value in confirming the patency of the GI tract before capsule endoscopy. The routine use of PC might eliminate the contraindication of capsule endoscopy in many cases of intestinal obstruction.
Assuntos
Endoscopia por Cápsula/métodos , Cápsulas , Obstrução Intestinal/diagnóstico , Intestino Delgado , Humanos , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To construct recombinant lentiviral vectors carrying Rheb gene and its mutant Rheb'D60K gene, and examine their expression in human liver cancer cells. METHODS: Rheb gene was amplified by PCR to construct the recombinant plasmid LV31-Rheb-WT and LV31-Rheb-D60K. HEK-293 FT cells were contransfected with the recombinant lentiviral vector together with a lentiviral package plasmid to produce the lentiviral particles. The expression of PS6 protein was detected in the lentivirus-infected MCF-7 cells. The apoptosis of SK-HEP-1 cells transfected with LV31-Rheb-WT or LV31-Rheb-D60K was observed. RESULTS: The recombinant LV31-Rheb-WT and LV31-Rheb-D60K vectors were confirmed by PCR and DNA sequencing. Western blotting showed that PS6 protein expression was increased in LV31-Rheb-WT-transfected cells while decreased in LV31-Rheb-D60K-transfected cells. LV31-Rheb-D60K-transfected SK-HEP-1 cells showed more obvious apoptosis after starvation than LV31-Rheb-WT-transfected cells. CONCLUSION: Lentiviral vectors carrying Rheb gene and its mutant has been successfully constructed, which can be useful in further investigation of the role of Rheb gene in cancer cells.