Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Rapid Commun Mass Spectrom ; 34 Suppl 2: e8662, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31731326

RESUMO

RATIONALE: Commercial-grade polymer synthesis is performed via melt polymerization, which leads to polydispersion. The work reported herein provides a synthetic strategy to produce mono-dispersive polyurethane oligomers and an analytical strategy to distinguish these oligomers, providing chemists with the tools necessary to synthesize and identify specific polymer structures that exhibit a desired property. METHODS: Three isomeric poly(ethylene glycol)-polyurethane (PEG-PUR) oligomers were synthesized and analyzed via flow-injection ion mobility mass spectrometry (IM-MS). Each polymer oligomer was injected and run independently via flow injection at 100 µL•min-1 and analyzed in positive ion mode on a drift tube quadrupole time-of-flight (QTOF) instrument. Mobility measurements were determined using a single-field approach. For tandem mass spectrometry (MS/MS) experiments, the sodium-adducted singly charged precursor ion was isolated in the quadrupole and subjected to a range of collision energies. RESULTS: In MS experiments, both +1 and +2 sodium-adducted species were observed for each oligomer at m/z 837.4 and 430.2, respectively. When isolated and fragmented via MS/MS, the +1 precursor yielded distinct product ions for each of the three isomeric oligomers. Fragmentation generally occurred at urethane linkages via 1,3- and 1,5-H shift mechanisms. IM was also used to distinguish the three isomers, with greater IM separation observed for the +2 versus the +1 species. CONCLUSIONS: Mono-disperse PEG-PUR oligomers were synthesized and analyzed. Although the polymeric oligomers analyzed in this study are quite small and structurally simple, this work serves as a model system for the synthesis and structural characterization of larger, more complex block copolymers.

2.
Trends Analyt Chem ; 116: 316-323, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31983792

RESUMO

The growth of lipidomics and the high isomeric complexity of the lipidome has revealed a need for analytical techniques capable of structurally characterizing lipids with a high degree of specificity. Lipids are morphologically diverse molecules that can exist as any one of a large number of isomeric species, and as such are often indistinguishable by mass spectrometry without a complementary separation method. Recent developments in the field of lipidomics aim to address these challenges by utilizing a combination of multiple analytical techniques which are selective to lipid primary structure. This review summarizes two emerging strategies for lipidomic analysis, namely, ion mobility-mass spectrometry and ion fragmentation via ozonolysis.

3.
Anal Chem ; 90(3): 1915-1924, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29341601

RESUMO

The increasing focus on lipid metabolism has revealed a need for analytical techniques capable of structurally characterizing lipids with a high degree of specificity. Lipids can exist as any one of a large number of double bond positional isomers, which are indistinguishable by single-stage mass spectrometry alone. Ozonolysis reactions coupled to mass spectrometry have previously been demonstrated as a means for localizing double bonds in unsaturated lipids. Here we describe an online, solution-phase reactor using ozone produced via a low-pressure mercury lamp, which generates aldehyde products diagnostic of cleavage at a particular double bond position. This flow-cell device is utilized in conjunction with structurally selective ion mobility-mass spectrometry. The lamp-mediated reaction was found to be effective for multiple lipid species in both positive and negative ionization modes, and the conversion efficiency from precursor to product ions was tunable across a wide range (20-95%) by varying the flow rate through the ozonolysis device. Ion mobility separation of the ozonolysis products generated additional structural information and revealed the presence of saturated species in a complex mixture. The method presented here is simple, robust, and readily coupled to existing instrument platforms with minimal modifications necessary. For these reasons, application to standard lipidomic workflows is possible and aids in more comprehensive structural characterization of a myriad of lipid species.


Assuntos
Cromatografia Líquida/métodos , Ácidos Graxos Insaturados/química , Lipídeos/química , Ozônio/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Galinhas , Ovos/análise , Glicerofosfolipídeos/química , Isomerismo
4.
Am J Physiol Lung Cell Mol Physiol ; 313(1): L52-L66, 2017 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-28428175

RESUMO

E-cigarettes are generally thought of as a safer smoking alternative to traditional cigarettes. However, little is known about the effects of e-cigarette liquids (e-liquids) on the lung. Since over 7,000 unique flavors have been identified for purchase in the United States, our goal was to conduct a screen that would test whether different flavored e-liquids exhibited different toxicant profiles. We tested the effects of 13 different flavored e-liquids [with nicotine and propylene glycol/vegetable glycerin (PG/VG) serving as controls] on a lung epithelial cell line (CALU3). Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay as an indicator of cell proliferation/viability, we demonstrated a dose-dependent decrease of MTT metabolism by all flavors tested. However, a group of four flavors consistently showed significantly greater toxicity compared with the PG/VG control, indicating the potential for some flavors to elicit more harmful effects than others. We also tested the aerosolized "vapor" from select e-liquids on cells and found similar dose-dependent trends, suggesting that direct e-liquid exposures are a justifiable first-pass screening approach for determining relative e-liquid toxicity. We then identified individual chemical constituents for all 13 flavors using gas chromatography-mass spectrometry. These data revealed that beyond nicotine and PG/VG, the 13 flavored e-liquids have diverse chemical constituents. Since all of the flavors exhibited some degree of toxicity and a diverse array of chemical constituents with little inhalation toxicity available, we conclude that flavored e-liquids should be extensively tested on a case-by-case basis to determine the potential for toxicity in the lung and elsewhere.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Células Epiteliais/citologia , Pulmão/citologia , Aerossóis , Morte Celular/efeitos dos fármacos , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Cinnamomum aromaticum/química , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Concentração Inibidora 50 , Mentol/farmacologia , Nicotina/farmacologia
5.
Analyst ; 140(20): 6871-8, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26325178

RESUMO

Differential ion mobility spectrometry (DIMS) separations are described using similar terminology to liquid chromatography, capillary electrophoresis, and drift tube ion mobility spectrometry. The characterization and comparison of all these separations are typically explained in terms of resolving power, resolution, and/or peak capacity. A major difference between these separations is that DIMS separations are in space whereas the others are separations in time. However, whereas separations in time can, in theory, be extended infinitely, separations in space, such as DIMS separations, are constrained by the physical dimensions of the device. One method to increase resolving power of DIMS separations is to use helium in the DIMS carrier gas. However, ions have a greater mobility in helium which causes more ions to be neutralized due to collisions with the DIMS electrodes or electrode housing, i.e. the space constraints. This neutralization of ions can lead to the loss of an entire peak, or peaks, from a DIMS scan. To take advantage of the benefits of helium use while reducing ion losses, linked scans were developed. During a linked scan the amount of helium present in the DIMS carrier gas is decreased as the compensation field is increased. A comparison of linked scans to compensation field scans with constant helium is presented herein. Resolving powers >7900 are obtained with linked scans. However, this result highlights the limitation of using resolving power as a metric to describe DIMS separations.

6.
J Am Soc Mass Spectrom ; 35(2): 214-223, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38215279

RESUMO

The complexity of the lipidome has necessitated the development of novel analytical approaches for the identification and structural analysis of morphologically diverse classes of lipids. At this time, a variety of dissociation techniques have been utilized to probe lipid decomposition pathways in search of structurally diagnostic fragment ions. Here, we investigate the application of surface-induced dissociation (SID), a fragmentation technique that imparts energy to the target molecule via collision with a coated surface, for the fragmentation of seven lipids across four major lipid subclasses. We have developed a tuning methodology for guiding the efficient operation of a previously developed custom SID device for molecules as small as ca. 300 Da with ion mobility analysis of the fragmentation products. SID fragmentation of the various lipids analyzed was found to generate fragment ions similar to those observed in CID spectra, but fragment ion lab frame onset energies were lower in SID due to the higher energy deposition via a more massive target. For the largest lipid evaluated (cardiolipin 18:1), SID produced chain fragment ions, which yielded analytically useful information regarding the composition of the acyl tails. Ion mobility provided an orthogonal dimension of separation and aided in assigning product ions to their precursors. Overall, the combination of SID and IM-MS is another potential methodology in the analytical toolkit for lipid structural analysis.


Assuntos
Espectrometria de Mobilidade Iônica , Lipídeos , Íons/química , Espectrometria de Massas/métodos
8.
Leuk Res ; 110: 106665, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34293710

RESUMO

The clinical implications of deletions within chromosome 14q32 in CLL pathogenesis remain unclear. We examined the frequency of 14q32 deletions among CLL cases by karyotype and FISH, categorized the variation using genomic microarray, and assessed the prognostic impact by time-to-first-treatment (TTFT) analysis. A 14q32 abnormality was detected in 35 % (245/698) of cases, with the majority containing a 5' partial telomeric 14q32 deletion. These deletions within the IGH variable region (35/40) ranged from 236 kb to 1.4 Mb involving FAM30A, ADAM6, LINC00226, and LINC00221. The 214 kb minimum deleted region implicated in CLL pathogenesis encompassed LINC00221. Cases with a 14q32 deletion had a shorter median TTFT compared to cases with a sole deletion/nullisomy 13q, a good prognostic indicator, and longer than cases with a sole deletion of 11q or 17p, conferring an unfavorable prognosis. This investigation underscores the importance of comprehensive testing to apprehend the implications of 14q32 deletions in CLL.


Assuntos
Biomarcadores Tumorais/genética , Deleção Cromossômica , Cromossomos Humanos Par 14/genética , Leucemia Linfocítica Crônica de Células B/patologia , Análise Citogenética , Humanos , Hibridização in Situ Fluorescente , Leucemia Linfocítica Crônica de Células B/epidemiologia , Leucemia Linfocítica Crônica de Células B/genética , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Estados Unidos/epidemiologia
9.
Methods Mol Biol ; 2306: 11-37, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33954937

RESUMO

Ion mobility (IM) is a gas phase separation strategy that can either supplement or serve as a high-throughput alternative to liquid chromatography (LC) in shotgun lipidomics. Incorporating the IM dimension in untargeted lipidomics workflows can help resolve isomeric lipids, and the collision cross section (CCS) values obtained from the IM measurements can provide an additional molecular descriptor to increase lipid identification confidence. This chapter provides a broad overview of an untargeted ion mobility-mass spectrometry (IM-MS) workflow using a commercial drift tube ion mobility-quadrupole-time-of-flight mass spectrometer (IM-QTOF) for high confidence lipidomics.


Assuntos
Lipidômica/métodos , Lipídeos/análise , Cromatografia Líquida , Humanos , Espectrometria de Mobilidade Iônica , Isomerismo , Espectrometria de Massas em Tandem , Fluxo de Trabalho
10.
J Am Soc Mass Spectrom ; 26(10): 1746-53, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26148526

RESUMO

Differential ion mobility spectrometry (DIMS) separates ions based on differences in their mobilities in low and high electric fields. When coupled to mass spectrometric analyses, DIMS has the ability to improve signal-to-background by eliminating isobaric and isomeric compounds for analytes in complex mixtures. DIMS separation power, often measured by resolution and peak capacity, can be improved through increasing the fraction of helium in the nitrogen carrier gas. However, because the mobility of ions is higher in helium, a greater number of ions collide with the DIMS electrodes or housing, yielding losses in signal intensity. To take advantage of the benefits of helium addition on DIMS separations and reduce ion losses, linked scans were developed. In a linked scan the helium content of the carrier gas is reduced as the compensation field is increased. Linked scans were compared with conventional compensation field scans with constant helium content for the protein ubiquitin and a tryptic digest of bovine serum albumin (BSA). Linked scans yield better separation of ubiquitin charge states and enhanced peak capacities for the analysis of BSA compared with compensation field scans with constant helium carrier gas percentages. Linked scans also offer improved signal intensity retention in comparison to compensation field scans with constant helium percentages in the carrier gas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA