Int J Artif Organs ; 32(6): 344-53, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19670186

RESUMO

OBJECTIVES: A multicentric European Clinical Study is ongoing to evaluate safety and efficacy of a new pulsatile implantable LVAD (BestBeat), smaller and lighter than similar devices, capable of providing synchronous and counterpulsating flow with respect to the LV of end-stage heart failure patients. Preliminary clinical results are reported. METHODS: The new BestBeat LVAD was used, consisting of an implantable pulsatile blood pump, electromechanically driven by a ball screw mechanism, and a wearable electronic controller and power sources. The clinical trial was conducted at 5 european centers. Adult patients affected by CHF in NYHA Class IV despite optimized medical treatment were enrolled. The primary study endpoint was survival at 90 days. Further study endpoints were maintenance of adequate LVAD pump flow and a minimum rate of adverse events during support. RESULTS: As of June 2008, 6 patients received the implant. Cumulative support time was 3.7 years, median support time 176 days. All patients who completed the study survived except for one, who died after 48 days, due to combined infection and cerebrovascular accident. Another two patients died: one from intracranial bleeding 113 days after implant, and one from septic shock after 123 days. Hemodynamic improvement with CI>2.0 l/min/m2 and recovery of end-organ function expressed by consistent improvement of BUN, creatinine and bilirubin were reached in all patients. No device failure was observed. There was no bleeding requiring re-exploration, no hemolysis and only two device-related infections (both in one patient). Neurologic events were reported, the most serious ones occurring in patients with pre-implant respiratory and kidney failure. Three patients were discharged home. Two patients were successfully transplanted, one after 6 months and one after 13 months on device. CONCLUSIONS: Good performance and efficacy of the device were observed; the endpoints of the study were achieved, and its safety was consistent with expectations. The ongoing study will allow further conclusions to be drawn.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Fluxo Pulsátil , Função Ventricular Esquerda , Bilirrubina/sangue , Biomarcadores/sangue , Nitrogênio da Ureia Sanguínea , Creatina/sangue , Desenho de Equipamento , Europa (Continente) , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA