Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Nucl Cardiol ; 26(2): 574-581, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-28905206

RESUMO

BACKGROUND: Attenuation correction using segmentation of scatter and photo-peak window data (SSPAC) enables an evaluation of the attenuation map in a patient-specific manner without additional radiation exposure. We compared the accuracy of SSPAC and non-corrected myocardial perfusion scintigraphy methods for diagnosing the number of stenosed coronary artery vessels. METHODS AND RESULTS: We retrospectively reviewed the data from 183 consecutive patients who underwent 99mTc-tetrofosmin stress/rest SPECT examination and a coronary angiography within 3 months. The MPS images were reconstructed with and without SSPAC attenuation correction. We examined the accuracy of the quantitative interpretation using summed differential score in the detection of coronary artery disease (CAD). The attenuation maps were successfully determined in 179 of 183 patients (98%). In terms of the vessel-based diagnostic ability, sensitivity, specificity, positive predictive and negative predictive values of the SSPAC and non-correction methods for diagnosing CAD in individual coronary territories were 77%*, 89%, 74%*, and 90%* vs 51%, 87%, 62%, and 82%, respectively (*P < .05). In 35 patients with multi-vessel CAD, those values were 78%*, 81%, 93%, and 55%* vs 49%, 81%, 89%, and 34%, respectively (*P < .05; AUC: 0.82 vs 0.62, P < .05). CONCLUSION: SSPAC-corrected SPECT myocardial perfusion images exhibit improved accuracy in the detection of the number of stenosed coronary artery vessels, even in patients with multi-vessel CAD.


Assuntos
Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Adenosina/química , Idoso , Constrição Patológica , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Compostos de Organotecnécio , Perfusão , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Espalhamento de Radiação
2.
J Nucl Cardiol ; 21(1): 109-17, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24185582

RESUMO

BACKGROUND: Attenuation correction using segmentation with scatter and photopeak window data (SSPAC) may enable evaluation of the attenuation map in a patient-specific manner without the need for additional radiation exposure and more acquisition time. We examined the feasibility of SSPAC and compared the sensitivity, specificity, and accuracy of this new correction method with that of conventional non-corrected myocardial perfusion single-photon emission computed tomography (SPECT) among patients with suspected or diagnosed coronary artery disease. METHODS AND RESULTS: One hundred sixty-one patients who underwent both (99m)Tc-tetrofosmin stress/rest SPECT examination and invasive coronary angiography were enrolled in the study. Data from the SSPAC-corrected and non-corrected methods were analyzed quantitatively using summed stress scores. Attenuation maps were obtained successfully for 150 (93%) of the patients. The SSPAC-corrected and non-corrected methods accurately predicted coronary artery disease defined as >50% luminal stenosis verified by coronary artery angiography and/or prior myocardial infarction, for 91% and 77% patients, respectively (P < .05). For diagnosis of coronary artery disease, SSPAC improved sensitivity in the left anterior descending artery territory and specificity in the right coronary artery territory. CONCLUSIONS: Attenuation correction with SSPAC may be a feasible method of correction for myocardial perfusion SPECT and in some cases may provide better accuracy for diagnosing coronary artery disease.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Índice de Massa Corporal , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Teste de Esforço , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Perfusão , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(5): 535-44, 2013 May.
Artigo em Japonês | MEDLINE | ID: mdl-23964534

RESUMO

In cerebral blood flow tests using N-Isopropyl-p-[123I] Iodoamphetamine "I-IMP, quantitative results of greater accuracy than possible using the autoradiography (ARG) method can be obtained with attenuation and scatter correction and image reconstruction by filtered back projection (FBP). However, the cutoff frequency of the preprocessing Butterworth filter affects the quantitative value; hence, we sought an optimal cutoff frequency, derived from the correlation between the FBP method and Xenon-enhanced computed tomography (XeCT)/cerebral blood flow (CBF). In this study, we reconstructed images using ordered subsets expectation maximization (OSEM), a method of successive approximation which has recently come into wide use, and also three-dimensional (3D)-OSEM, a method by which the resolution can be corrected with the addition of collimator broad correction, to examine the effects on the regional cerebral blood flow (rCBF) quantitative value of changing the cutoff frequency, and to determine whether successive approximation is applicable to cerebral blood flow quantification. Our results showed that quantification of greater accuracy was obtained with reconstruction employing the 3D-OSEM method and using a cutoff frequency set near 0.75-0.85 cycles/cm, which is higher than the frequency used in image reconstruction by the ordinary FBP method.


Assuntos
Circulação Cerebrovascular , Iofetamina , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imagens de Fantasmas , Fluxo Sanguíneo Regional
4.
Kaku Igaku ; 44(1): 1-7, 2007 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-18240578

RESUMO

To confirm the previous reports demonstrating the difference in the octanol extraction fractions between the currently available two N-isopropyl-4-iodoamphetamine (123I) products (IMP(A) and IMP(B)), we newly developed the standard input function for IMP(B) in 19 healthy volunteers and compared it with the established standard input function, which has been originally generated with IMP(A). The octanol extraction fractions of IMP(B) were stable from 5 minutes to 16 minutes post injection and significantly higher than those of IMP(A). The mCBFs calculated with IMP(B) by using the established standard input function for IMP(A) tended to be higher than those with the combination of IMP(A) and the established standard input function though the difference was not significant. When measured with IMP(B) combined with the correspondent standard input function, mCBFs were identical to those calculated with IMP(A) with the established standard input function, suggesting that the appropriate standard input function should be used according to the product used.


Assuntos
Radioisótopos do Iodo/normas , Iofetamina/normas , Compostos Radiofarmacêuticos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único
5.
Ann Nucl Med ; 19(4): 277-81, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16097636

RESUMO

UNLABELLED: The aim of this study was to evaluate the usefulness of deep inspiration breath-hold SPECT (BrST, a method for 201Tl SPECT) in the diagnosis of solitary pulmonary nodules (SPN). METHODS: Ten patients with malignant lesions and five with benign lesions were enrolled in this study. Early SPECT acquisition was performed 15 min after injection of 201Tl, while delayed SPECT images were acquired 3 h after injection. The first 15-sec acquisition was done using the BrST technique, and the second with the conventional free breathing (FB) method. We performed this technique alternately, and therefore, the odd data were from BrST and the even data were from FB. We referred to the T/N ratio of the early images as the ER and to the T/N ratio of the delayed images as the DR. To semi-quantitatively evaluate the degree of retention in the lesion, the retention index (RI) was calculated. RESULTS: The RI of BrST indicated greater accuracy than that of FB in the differential diagnosis of SPN. For the benign and malignant lesions, the RI of BrST was -3.07 +/- 31.51 and 29.86 +/- 25.01, respectively (p < 0.05). The sensitivity, specificity, and accuracy of BrST (80%, 80%, and 80%, respectively) were significantly higher than those of FB (p < 0.05). CONCLUSION: The BrST method is more accurate than that of the conventional FB method in the differential diagnosis of SPN.


Assuntos
Artefatos , Aumento da Imagem/métodos , Respiração , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tálio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Nucl Med Technol ; 33(4): 224-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16322122

RESUMO

OBJECTIVE: The radioactivity count distribution in the brain must be determined accurately to accurately measure cerebral blood flow (CBF). Scatter and attenuation are factors that compromise the accuracy of determining radioactivity counts in the brain. METHODS: We compared regional CBF in patients by an autoradiographic method using N-isopropyl-p-[123I] iodoamphetamine when, first, attenuation correction alone was performed uniformly on SPECT images by using empiric mu-values (Chang method); second, scatter correction was performed and the mu-values of a homogeneous-attenuation body of water were used for attenuation correction (triple-energy window [TEW]+Chang method); and third, scatter correction was performed and the mu-values calculated by CT were used for attenuation correction (TEW+CT method). We also compared regional CBF measured by these methods with the values obtained by the xenon CT/CBF method, which uses CT and stable xenon. RESULTS: Scatter correction reduced overestimation of regional CBF in low-flow regions. The TEW+CT method yielded better regional and overall correlations with the xenon CT/CBF method than did either of the other methods. CONCLUSION: The TEW+CT method of correction gave the most accurate measurements of regional CBF.


Assuntos
Autorradiografia/métodos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Algoritmos , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
7.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 61(8): 1144-50, 2005 Aug 20.
Artigo em Japonês | MEDLINE | ID: mdl-16132033

RESUMO

Because SPECT images are acquired under normal respiration, the respiratory motion induces artifacts and decreases resolution. In this study we developed a novel method of acquiring SPECT data during deep inhalation breath-hold (BrST) and assessed its efficacy in reducing motion artifacts and improving resolution. Reproducibility studies found that variations in SPECT image homogeneity were reduced using the BrST method to within a clinically non-problematic range. An experiment using a custom-built respiration phantom showed almost complete elimination of motion artifacts and significant improvement in resolution using the BrST method. Clinical assessment confirmed a significant reduction in motion artifacts along with the improvement in resolution. The BrST method enabled visualization of lesions that previously had been impossible to detect by standard acquisition under normal respiration. The BrST method is expected to both significantly reduce motion artifacts and improve resolution.


Assuntos
Aumento da Imagem/métodos , Respiração , Fenômenos Fisiológicos Respiratórios , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Artefatos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento (Física) , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
J Nucl Med ; 56(12): 1889-94, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26359259

RESUMO

UNLABELLED: Postsystolic shortening (PSS), which is a delayed myocardial contraction that occurs after end-systole, has been considered an important diagnostic index of myocardial ischemia. Recent technological advancements in quantitative gated SPECT (QGS) software enables the left ventricular (LV) regional analysis and may be useful for PSS measurement. The purpose of this study was to evaluate whether PSS at the resting condition determined by QGS is useful to identify patients with coronary artery disease. METHODS: The study comprised 146 patients (mean age ± SD, 71 ± 8 y; 98 men) with normal LV wall motion (mean LV ejection fraction ± SD, 72% ± 9%) who underwent both coronary angiography and resting (99m)Tc-tetrofosmin myocardial perfusion SPECT. The sum of the difference between post-end-systolic maximal LV thickening and end-systolic LV thickening, designated PSS index, was calculated from 17 LV myocardial segments using QGS. RESULTS: The PSS index was significantly higher in patients with significant stenosis of the coronary artery than in the other patients (9.8 ± 10.2 vs. 5.6 ± 5.1; P < 0.01). A cutoff point of 6.0 of the PSS index had sensitivity, specificity, positive predictive value, and negative predictive values of 55%, 70%, 76%, and 47%, respectively, for the diagnosis of coronary artery disease. Multivariate logistic regression analysis demonstrated that a PSS index greater than 6.0 was an independent predictor for the presence of coronary artery disease (odds ratio, 2.46; 95% confidence interval, 1.1-5.4; P < 0.05). CONCLUSION: Among subjects with normal LV function, PSS index even in the resting condition determined using QGS may help to identify patients with coronary artery disease.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Imagem de Perfusão do Miocárdio/métodos , Idoso , Angiografia Coronária , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda
9.
Artigo em Japonês | MEDLINE | ID: mdl-22687902

RESUMO

Autoradiography (ARG) has been used for quantitative analysis of the cerebral blood flow using 123I-IMP, and the regional cerebral blood flow (rCBF) can be assessed more accurately with scatter and attenuation correction. Currently, the filtered back projection (FBP) method is generally used for image reconstruction. However, we anticipate obtaining more accurate rCBF by the ordered subsets expectation maximization method with collimator broad correction three dimensional ordered subsets expectation maximization (3D-OSEM). In the present study, we optimized the processing conditions to quantify rCBF using the 3D-OSEM method and compared them with the FBP method. Regarding the method, we determined the subsets and iteration, compared rCBF values using a profile curve, and compared them with the rCBF values obtained by the XeCT (Xenon-enhanced computed tomography)/CBF method. We found that in the 3D-OSEM method using 90 direction collection and 1.72 mm/pixel, the most accurate image was obtained around subset 9 and iteration 10. In addition, as compared to the profile curve and the XeCT/CBF method, the thalamus rCBF was high in the 3D-OSEM method with a good correlation with that of the XeCT/CBF. Accordingly, we concluded that the 3D-OSEM method can improve the decrease in rCBF due to blurring of the distance between the source (i.e., a structure located in the central part of the brain such as the thalamus and the collimator).


Assuntos
Circulação Cerebrovascular , Processamento de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Autorradiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
10.
Ann Nucl Med ; 24(4): 325-34, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20401547

RESUMO

This synopsis outlines the Japanese guideline Version 1.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology (JSNMT) and the Japanese Council of PET Imaging, and published in Kakuigaku-Gijutsu 29(2):195-235, 2009, in Japanese. The guideline aims at standardizing the PET image quality among facilities and different PET/CT scanner models by determining and/or evaluating the data acquisition condition in experiments using an IEC body phantom, as well as by proposing the criteria for human image quality evaluation using patient noise equivalent count (NEC), NEC density, and liver signal-to-noise ratio.


Assuntos
Fluordesoxiglucose F18 , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Japão , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/normas , Controle de Qualidade , Tomografia Computadorizada por Raios X/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA