Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Exp Eye Res ; 194: 108001, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32173378

RESUMO

Elastic fibres provide tissues with elasticity and flexibility. In the healthy human cornea, elastic fibres are limited to the posterior region of the peripheral stroma, but their specific functional role remains elusive. Here, we examine the physical and structural characteristics of the cornea during development in the mgΔloxPneo dominant-negative mouse model for Marfan syndrome, in which the physiological extracellular matrix of its elastic-fibre rich tissues is disrupted by the presence of a dysfunctional fibrillin-1 glycoprotein. Optical coherence tomography demonstrated a reduced corneal thickness in the mutant compared to wild type mice from embryonic day 16.5 until adulthood. X-ray scattering and electron microscopy revealed a disruption to both the elastic fibre and collagen fibril ultrastructure in the knockout mice, as well as abnormally low levels of the proteoglycan decorin. It is suggested that these alterations might be a result of increased transforming growth factor beta signalling. To conclude, this study has demonstrated corneal structure and ultrastructure to be altered when fibrillin-1 is disrupted and has provided insights into the role of fibrillin-1 in developing a functional cornea.


Assuntos
Córnea/anormalidades , Matriz Extracelular/metabolismo , Síndrome de Marfan/patologia , Animais , Córnea/metabolismo , Córnea/ultraestrutura , Modelos Animais de Doenças , Elasticidade , Feminino , Fibrilina-1/metabolismo , Síndrome de Marfan/metabolismo , Camundongos , Camundongos Knockout , Microscopia Eletrônica , Tomografia de Coerência Óptica/métodos
2.
Br J Nurs ; 26(12): 695, 2017 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-28640729

RESUMO

Jo McCormick, Consultant Nurse and Associate Director of Nursing, Belfast Health and Social Care Trust, Joanna.McCormick@belfasttrust.hscni.net , and Sally Hayes, Director of Strategy, Planning and Resources at the Open University, share their insights from undertaking a Florence Nightingale Leadership Scholarship.


Assuntos
Distinções e Prêmios , Empatia , Relações Enfermeiro-Paciente , Cuidados de Enfermagem/psicologia , Recursos Humanos de Enfermagem/psicologia , Qualidade da Assistência à Saúde , Autocuidado , Adulto , Atitude do Pessoal de Saúde , Atitude Frente a Saúde , Bolsas de Estudo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reino Unido
3.
Exp Eye Res ; 153: 141-151, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27765574

RESUMO

The aim of this study was to investigate corneal enzymatic resistance following epithelium off and on riboflavin/UVA cross-linking (CXL). One hundred and fourteen porcine eyes were divided into four non-irradiated control groups and seven CXL groups. The latter comprised; (i) epithelium-off, 0.1% iso-osmolar riboflavin, 9 mW UVA irradiation for 10 min, (ii) disrupted epithelium, 0.1% hypo-osmolar riboflavin, 9 mW UVA for 10 min, (iii) epithelium-on, 0.25% hypo-osmolar riboflavin with 0.01% benzylalkonium chloride (BACS), 9 mW UVA for 10 min, (iv) epithelium-on, 5 min iontophoresis at 0.1 mA for 5 min with 0.1% riboflavin solution, 9 mW UVA for 10 min or (v) 12.5 min, (vi) epithelium-on, prolonged iontophoresis protocol of 25 min with 1.0 mA for 5 min and 0.5 mA for 5 min with 0.25% riboflavin with 0.01% BACS, 9 mW UVA for 10 min or (vii) 12.5 min. Enzymatic resistance was assessed by daily measurement of a corneal button placed in pepsin solution and measurement of corneal button dry weight after 11 days of digestion. This study revealed that the enzymatic resistance was greater in CXL corneas than non-irradiated corneas (p < 0.0001). Epithelium-off CXL showed the greatest enzymatic resistance (p < 0.0001). The prolonged iontophoresis protocol was found to be superior to all other trans-epithelial protocols (p < 0.0001). A 25% increase in UVA radiance significantly increased corneal enzymatic resistance (p < 0.0001). In conclusion, although epithelium-on CXL appears to be inferior to epithelium-off CXL in terms of enzymatic resistance to pepsin digestion, the outcome of epithelium-on CXL may be significantly improved through the use of higher concentrations of riboflavin solution, a longer duration of iontophoresis and an increase in UVA radiance.


Assuntos
Reagentes de Ligações Cruzadas/uso terapêutico , Resistência a Medicamentos , Epitélio Corneano/efeitos dos fármacos , Ceratocone/tratamento farmacológico , Pepsina A/farmacologia , Fotoquimioterapia/métodos , Riboflavina/farmacologia , Animais , Modelos Animais de Doenças , Epitélio Corneano/metabolismo , Epitélio Corneano/patologia , Ceratocone/metabolismo , Ceratocone/patologia , Fármacos Fotossensibilizantes/farmacologia , Suínos
4.
Graefes Arch Clin Exp Ophthalmol ; 253(12): 2223-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26345527

RESUMO

PURPOSE: This laboratory-based investigation compares the topographic outcomes of conventional penetrating keratoplasty with that of a novel procedure in which donor corneas are cross-linked prior to keratoplasty. METHODS: Penetrating keratoplasty procedures with continuous running sutures were carried out in a porcine whole globe model. Sixty eyes were randomly paired as 'donor' and 'host' tissue before being assigned to one of two groups. In the cross-linked group, donor corneas underwent riboflavin/UVA cross-linking prior to being trephined and sutured to untreated hosts. In the conventional keratoplasty group, both host and donor corneas remained untreated prior to keratoplasty. Topographic and corneal wavefront measurements were performed following surgery, and technical aspects of the procedure evaluated. RESULTS: Mean keratometric astigmatism was significantly lower in the cross-linked donor group at 3.67D (SD 1.8 D), vs. 8.43 D (SD 2.4 D) in the conventional keratoplasty group (p < 0.005). Mean wavefront astigmatism was also significantly reduced in the cross-linked donor group 4.71 D (SD 2.1) vs. 8.29D (SD 3.6) in the conventional keratoplasty group (p < 0.005). Mean RMS higher order aberration was significantly lower in the cross-linked donor group at 1.79 um (SD 0.98), vs. 3.05 um (SD 1.9) in the conventional keratoplasty group (P = 0.02). Qualitative analysis revealed less tissue distortion at the graft-host junction in the cross-linked group. CONCLUSION: Cross-linking of donor corneas prior to keratoplasty reduces intraoperative induced astigmatism and aberrations in an animal model. Further studies are indicated to evaluate the implications of this potential modification of keratoplasty surgery.


Assuntos
Astigmatismo/prevenção & controle , Aberrações de Frente de Onda da Córnea/prevenção & controle , Reagentes de Ligações Cruzadas , Ceratoplastia Penetrante , Fármacos Fotossensibilizantes/uso terapêutico , Doadores de Tecidos , Animais , Colágeno/metabolismo , Substância Própria/metabolismo , Topografia da Córnea , Cuidados Pré-Operatórios , Riboflavina/uso terapêutico , Suínos , Raios Ultravioleta
5.
Eye (Lond) ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396030

RESUMO

The cornea needs to be transparent to visible light and precisely curved to provide the correct refractive power. Both properties are governed by its structure. Corneal transparency arises from constructive interference of visible light due to the relatively ordered arrangement of collagen fibrils in the corneal stroma. The arrangement is controlled by the negatively charged proteoglycans surrounding the fibrils. Small changes in fibril organisation can be tolerated but larger changes cause light scattering. Corneal keratocytes do not scatter light because their refractive index matches that of the surrounding matrix. When activated, however, they become fibroblasts that have a lower refractive index. Modelling shows that this change in refractive index significantly increases light scatter. At the microscopic level, the corneal stroma has a lamellar structure, the parallel collagen fibrils within each lamella making a large angle with those of adjacent lamellae. X-ray scattering has shown that the lamellae have preferred orientations in the human cornea: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus. The directions at the centre of the cornea may help withstand the pull of the extraocular muscles whereas the pseudo-circular arrangement at the limbus supports the change in curvature between the cornea and sclera. Elastic fibres are also present; in the limbus they contain fibrillin microfibrils surrounding an elastin core, whereas at the centre of the cornea, they exist as thin bundles of fibrillin-rich microfibrils. We present a model based on the structure described above that may explain how the cornea withstands repeated pressure changes due to the ocular pulse.

6.
Eye Vis (Lond) ; 11(1): 8, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38414033

RESUMO

BACKGROUND: Corneal cross-linking (CXL) using riboflavin and ultraviolet-A light (UVA) is a treatment used to prevent progression of keratoconus. This ex vivo study assesses the impact on CXL effectiveness, as measured by tissue enzymatic resistance and confocal microscopy, of including a pre-UVA corneal surface rinse with balanced salt solution (BSS) as part of the epithelium-off treatment protocol. METHODS: Sixty-eight porcine eyes, after epithelial debridement, were assigned to six groups in three experimental runs. Group 1 remained untreated. Groups 2-6 received a 16-min application of 0.1% riboflavin/Hydroxypropyl methylcellulose (HPMC) drops, after which Group 3 was exposed to 9 mW/cm2 UVA for 10 min, and Groups 4-6 underwent corneal surface rinsing with 0.25 mL, 1 mL or 10 mL BSS followed by 9 mW/cm2 UVA exposure for 10 min. Central corneal thickness (CCT) was recorded at each stage. Central 8.0 mm corneal buttons from all eyes were subjected to 0.3% collagenase digestion at 37 °C and the time required for complete digestion determined. A further 15 eyes underwent fluorescence confocal microscopy to assess the impact of rinsing on stromal riboflavin concentration. RESULTS: Application of riboflavin/HPMC solution led to an increase in CCT of 73 ± 14 µm (P < 0.01) after 16 min. All CXL-treated corneas displayed a 2-4 fold greater resistance to collagenase digestion than non-irradiated corneas. There was no difference in resistance between corneas that received no BSS rinse and those that received a 0.25 mL or 1 mL pre-UVA rinse, but each showed a greater level of resistance than those that received a 10 mL pre-UVA rinse (P < 0.05). Confocal microscopy demonstrated reduced stromal riboflavin fluorescence after rinsing. CONCLUSIONS: All protocols, with and without rinsing, were effective at enhancing the resistance to collagenase digestion, although resistance was significantly decreased, and stromal riboflavin fluorescence reduced with a 10 mL rinse. This suggests that a 10 mL surface rinse can reduce the efficacy of CXL through the dilution of the stromal riboflavin concentration.

7.
Nat Commun ; 15(1): 5508, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951161

RESUMO

Keratoconus, a disorder characterized by corneal thinning and weakening, results in vision loss. Corneal crosslinking (CXL) can halt the progression of keratoconus. The development of accelerated corneal crosslinking (A-CXL) protocols to shorten the treatment time has been hampered by the rapid depletion of stromal oxygen when higher UVA intensities are used, resulting in a reduced cross-linking effect. It is therefore imperative to develop better methods to increase the oxygen concentration within the corneal stroma during the A-CXL process. Photocatalytic oxygen-generating nanomaterials are promising candidates to solve the hypoxia problem during A-CXL. Biocompatible graphitic carbon nitride (g-C3N4) quantum dots (QDs)-based oxygen self-sufficient platforms including g-C3N4 QDs and riboflavin/g-C3N4 QDs composites (RF@g-C3N4 QDs) have been developed in this study. Both display excellent photocatalytic oxygen generation ability, high reactive oxygen species (ROS) yield, and excellent biosafety. More importantly, the A-CXL effect of the g-C3N4 QDs or RF@g-C3N4 QDs composite on male New Zealand white rabbits is better than that of the riboflavin 5'-phosphate sodium (RF) A-CXL protocol under the same conditions, indicating excellent strengthening of the cornea after A-CXL treatments. These lead us to suggest the potential application of g-C3N4 QDs in A-CXL for corneal ectasias and other corneal diseases.


Assuntos
Reagentes de Ligações Cruzadas , Grafite , Oxigênio , Pontos Quânticos , Riboflavina , Pontos Quânticos/química , Animais , Grafite/química , Oxigênio/metabolismo , Riboflavina/farmacologia , Coelhos , Masculino , Reagentes de Ligações Cruzadas/química , Compostos de Nitrogênio/química , Espécies Reativas de Oxigênio/metabolismo , Ceratocone/tratamento farmacológico , Ceratocone/metabolismo , Raios Ultravioleta , Córnea/efeitos dos fármacos , Córnea/metabolismo , Córnea/patologia , Humanos , Fármacos Fotossensibilizantes/farmacologia , Substância Própria/metabolismo , Substância Própria/efeitos dos fármacos
8.
Ophthalmic Physiol Opt ; 33(2): 78-93, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23406488

RESUMO

PURPOSE: To review cross-linking the cornea using riboflavin and ultraviolet A light, which has been widely adopted, refined and applied in a range of corneal surgeries and pathologies where the strength of the cornea might be compromised. RECENT FINDINGS: A large number of clinical trials have been carried out, most of which have demonstrated that standard cross-linking is a successful method to halt the progression of keratoconus or even aid regression. SUMMARY: This review describes our current understanding of the technique, focussing on how cross-linking works, how the treatment is being optimised, the clinical results that have been reported to date and the potential use of the therapy in the treatment of other corneal disorders.


Assuntos
Córnea/efeitos dos fármacos , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Ensaios Clínicos como Assunto , Humanos , Raios Ultravioleta
9.
Eye (Lond) ; 37(12): 2511-2517, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36539601

RESUMO

OBJECTIVE: To provide an insight into trends in corneal cross-linking (CXL) practice in the UK, including criteria for progression of corneal ectasia, identification of patients for CXL, the CXL procedure itself and post-operative management. METHODS: All ophthalmologist members of the UK Cross-linking (UK-CXL) Consortium were invited to complete an online survey about CXL practice for the year 2019. The data collected was anonymised by site and analysed with descriptive statistics. RESULTS: Responses were received from 16 individual CXL centres (16/38; 42% response rate) and the data represented ~2,000 CXL procedures performed in the UK in 2019. The commonest indication for CXL was progressive keratoconus. Between centres, there were variations in diagnostic evaluation, patient selection for CXL, the CXL procedure and the pre- and post-operative monitoring of patients. CONCLUSION: Consistent with the wide number of CXL treatment techniques described in the published literature world-wide, variations in the monitoring of corneal ectasia, indications for CXL, CXL practice and post-CXL follow-up were found to exist between UK-based CXL centres.


Assuntos
Ceratocone , Fotoquimioterapia , Humanos , Fármacos Fotossensibilizantes/uso terapêutico , Crosslinking Corneano , Riboflavina/uso terapêutico , Raios Ultravioleta , Dilatação Patológica/tratamento farmacológico , Colágeno/uso terapêutico , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/diagnóstico , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Reino Unido , Topografia da Córnea
10.
J Refract Surg ; 38(7): 450-458, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35858194

RESUMO

PURPOSE: To examine central corneal thickness (CCT) changes during in vivo rose bengal-green light corneal cross-linking (RG-CXL) and compare the CXL efficacy of different rose bengal formulations. METHODS: After epithelium removal, the right eyes of rabbits were immersed in rose bengal solution prepared by different solvents (water, phosphate buffered saline, dextran, and hydroxypropyl methylcellulos [HPMC]) for 2 or 20 minutes, then the rose bengal distribution in the corneal stroma was analyzed by confocal fluorescence detection. During the RG-CXL process, the CCT was measured at seven time points. The left eyes served as the untreated control group. Corneal enzymatic resistance and corneal biomechanics were tested to compare the RG-CXL efficacy. RESULTS: The rose bengal infiltration depths were 120 and 200 µm for the 2- and 20-minute groups, respectively. CCT increased significantly after infiltration, then decreased significantly in the first 200 seconds of irradiation and decreased slowly for the next 400 seconds. The CCT of the 20-minute groups was significantly thicker than that of the 2-minute groups (P < .0001). All RG-CXL treatments improved the corneal enzymatic resistance and corneal biomechanics, with the effects being greater in the 20-minute groups. The inclusion of 1.1% HPMC in the rose bengal formulation helped to maintain CCT during irradiation while not affecting either the infiltration of rose bengal or the efficacy of RG-CXL. CONCLUSIONS: Within the range studied, RG-CXL efficacy increased with infiltration time. The incorporation of a 20-minute infiltration of 0.1% rose bengal-1.1% HPMC into the RG-CXL procedure may further improve the safety of the treatment and its prospects for clinical use. [J Refract Surg. 2022;38(7):450-458.].


Assuntos
Riboflavina , Rosa Bengala , Animais , Colágeno/metabolismo , Córnea/metabolismo , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Fármacos Fotossensibilizantes/uso terapêutico , Coelhos , Riboflavina/farmacologia , Riboflavina/uso terapêutico , Rosa Bengala/metabolismo , Rosa Bengala/farmacologia , Raios Ultravioleta
11.
Acta Biomater ; 142: 185-193, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35081430

RESUMO

The mechanical properties of connective tissues are tailored to their specific function, and changes can lead to dysfunction and pathology. In most mammalian tissues the mechanical environment is governed by the micro- and nano-scale structure of collagen and its interaction with other tissue components, however these hierarchical properties remain poorly understood. In this study we use the human cornea as a model system to characterise and quantify the dominant deformation mechanisms of connective tissue in response to cyclic loads of physiological magnitude. Synchronised biomechanical testing, x-ray scattering and 3D digital image correlation revealed the presence of two dominant mechanisms: collagen fibril elongation due to a largely elastic, spring-like straightening of tropocollagen supramolecular twist, and a more viscous straightening of fibril crimp that gradually increased over successive loading cycles. The distinct mechanical properties of the two mechanisms suggest they have separate roles in vivo. The elastic, spring-like mechanism is fast-acting and likely responds to stresses associated with the cardiac cycle, while the more viscous crimp mechanism will respond to slower processes, such as postural stresses. It is anticipated that these findings will have broad applicability to understanding the normal and pathological functioning of other connective tissues such as skin and blood vessels that exhibit both helical structures and crimp. STATEMENT OF SIGNIFICANCE: The tropocollagen spring mechanism allows collagen fibrils from some tissues to elongate significantly under small loads, and its recent discovery has the potential to change our fundamental understanding of how tissue deforms. This time-resolved study quantifies the contribution of the spring mechanism to the local strain in stretched tissue and compares it to the contribution associated with the straightening of fibril waviness, the widely accepted primary low-load strain mechanism. The spring mechanism contributed more to the local tissue strain than fibril straightening, and was found to be elastic while fibril straightening was more viscous. The results suggest that the viscoelastic behaviour of a biomaterial is controlled, at least in part, by the relative amount of fibril-scale crimp and tropocollagen supramolecular twist.


Assuntos
Colágeno , Tropocolágeno , Animais , Fenômenos Biomecânicos , Colágeno/química , Tecido Conjuntivo , Matriz Extracelular , Humanos , Mamíferos , Viscosidade
12.
Biophys J ; 101(1): 33-42, 2011 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-21723812

RESUMO

The collagen microstructure of the peripheral cornea is important in stabilizing corneal curvature and refractive status. However, the manner in which the predominantly orthogonal collagen fibrils of the central cornea integrate with the circumferential limbal collagen is unknown. We used microfocus wide-angle x-ray scattering to quantify the relative proportion and orientation of collagen fibrils over the human corneolimbal interface at intervals of 50 µm. Orthogonal fibrils changed direction 1-1.5 mm before the limbus to integrate with the circumferential limbal fibrils. Outside the central 6 mm, additional preferentially aligned collagen was found to reinforce the cornea and limbus. The manner of integration and degree of reinforcement varied significantly depending on the direction along which the limbus was approached. We also employed small-angle x-ray scattering to measure the average collagen fibril diameter from central cornea to limbus at 0.5 mm intervals. Fibril diameter was constant across the central 6 mm. More peripherally, fibril diameter increased, indicative of a merging of corneal and scleral collagen. The point of increase varied with direction, consistent with a scheme in which the oblique corneal periphery is reinforced by chords of scleral collagen. The results have implications for the cornea's biomechanical response to ocular surgeries involving peripheral incision.


Assuntos
Colágeno/química , Córnea/metabolismo , Idoso , Idoso de 80 Anos ou mais , Colágenos Fibrilares/química , Humanos , Limbo da Córnea/metabolismo , Pessoa de Meia-Idade , Modelos Biológicos , Difração de Raios X
13.
Mol Vis ; 17: 3107-15, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22171156

RESUMO

PURPOSE: In the visually debilitating condition of climatic droplet keratopathy, corneal transparency is progressively lost. Although the precise cause of the disease and the mechanism by which it progresses are not known, a lifetime exposure to high solar radiation and a vitamin C-deficient diet may be involved in its development. This study examines the effect of dietary ascorbate levels and ultraviolet (UV)-B exposure on corneal stromal structure. METHODS: Eight guinea pigs were divided into four treatment groups (A, B, C, and D). For 15 weeks, Groups A and C were fed an ascorbate-rich diet (2 mg/100 g bodyweight/day), while Groups B and D received an ascorbate-deficient diet (0.07 mg/100 g bodyweight/day). For the last 12 weeks of the study, Groups C and D also experienced chronic UVB exposure (0.12 J/cm² for 40 min/day). Following euthanasia, the corneas were enucleated and their stromal ultrastructure examined using X-ray scattering and electron microscopy. RESULTS: UVB exposure resulted in an increased corneal thickness (p<0.001), but this was not accompanied by a widespread expansion of the collagen fibrillar array, and in the case of ascorbate-deficient animals, stromal thickening was associated with the compaction of collagen fibrils (p<0.01). Neither UVB exposure nor ascorbic acid deficiency caused any change in the average diameter or D-periodicity of the stromal collagen fibrils. CONCLUSIONS: UVB-induced changes in the corneal ultrastructure were most pronounced in animals fed an ascorbic acid-deficient diet. This suggests that ascorbic acid may play a vital role in protecting the corneal stroma from the harmful effects of UVB.


Assuntos
Deficiência de Ácido Ascórbico/patologia , Córnea/efeitos da radiação , Córnea/ultraestrutura , Raios Ultravioleta , Animais , Peso Corporal , Córnea/patologia , Substância Própria/patologia , Substância Própria/efeitos da radiação , Substância Própria/ultraestrutura , Cobaias , Masculino , Microscopia , Espalhamento a Baixo Ângulo , Difração de Raios X
14.
Ther Adv Rare Dis ; 2: 26330040211003573, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37181107

RESUMO

Keratoconus is a condition in which the cornea progressively thins and weakens, leading to severe, irregular astigmatism and a significant reduction in quality of life. Although the precise cause of keratoconus is still not known, biochemical and structural studies indicate that overactive enzymes within the cornea break down the constituent proteins (collagen and proteoglycans) and cause the tissue to weaken. As the disease develops, collagen fibres slip past each other and are redistributed across the cornea, causing it to change shape. In recent years, it was discovered that the photochemical induction of cross-links within the corneal extracellular matrix, through the use of riboflavin and ultraviolet (UVA) light, could increase the strength and enzymatic resistance of the tissue and thereby halt keratoconus progression. Worldwide acceptance and use of riboflavin/UVA corneal cross-linking therapy for halting keratoconus progression has increased rapidly, in accordance with the growing body of evidence supporting its long-term effectiveness. This review focusses on the inception of riboflavin/UVA corneal cross-linking therapy for keratoconus, its clinical effectiveness and the latest scientific advances aimed at reducing patient treatment time, improving patient comfort and increasing patient eligibility for treatment. Plain language summary: Review of current treatments using cross-linking to halt the progress of keratoconus Keratoconus is a disease in which the curved cornea, the transparent window at the front of the eye, weakens, bulges forward into a cone-shape and becomes thinner. This change of curvature means that light is not focussed onto the retina correctly and vision is progressively impaired. Traditionally, the effects of early keratoconus were alleviated by using glasses, specialist contact lenses, rings inserted into the cornea and in severe cases, by performing a corneal transplant. However, it was discovered that by inducing chemical bonds called cross-links within the cornea, the tissue could be strengthened and further thinning and shape changes prevented. The standard cross-linking procedure takes over an hour to perform and involves the removal of the cells at the front of the cornea, followed by the application of Vitamin B2 eye drops and low energy ultraviolet light (UVA) to create new cross-links within the tissue. Clinical trials have shown this standard procedure to be safe and effective at halting keratoconus progression. However, there are many treatment modifications currently under investigation that aim to reduce patient treatment time and increase comfort, such as accelerated cross-linking procedures and protocols that do not require removal of the surface cells. This review describes the different techniques being developed to carry out corneal cross-linking efficiently and painlessly, to halt keratoconus progression and avoid the need for expensive surgery.

15.
J R Soc Interface ; 18(175): 20200900, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33622146

RESUMO

This study aims to estimate the reduction in collagen fibril density within the central 6 mm radius of keratoconic corneas through the processing of microstructure and videokeratography data. Collagen fibril distribution maps and topography maps were obtained for seven keratoconic and six healthy corneas, and topographic features were assessed to detect and calculate the area of the cone in each keratoconic eye. The reduction in collagen fibril density within the cone area was estimated with reference to the same region in the characteristic collagen fibril maps of healthy corneas. Together with minimum thickness and mean central corneal refractive power, the cone area was correlated with the reduction in the cone collagen fibrils. For the corneas considered, the mean area of keratoconic cones was 3.30 ± 1.90 mm2. Compared with healthy corneas, fibril density in the cones of keratoconic corneas was lower by as much as 35%, and the mean reduction was 17 ± 10%. A linear approximation was developed to relate the magnitude of reduction to the refractive power, minimum corneal thickness and cone area (R2 = 0.95, p < 0.001). Outside the cone area, there was no significant difference between fibril arrangement in healthy and keratoconic corneas. The presented method can predict the mean fibril density in the keratoconic eye's cone area. The technique can be applied in microstructure-based finite-element models of the eye to regulate its stiffness level and the stiffness distribution within the areas affected by keratoconus.


Assuntos
Córnea , Ceratocone , Topografia da Córnea , Humanos
16.
J Struct Biol ; 169(3): 424-30, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19914381

RESUMO

A network of circumferentially oriented collagen fibrils exists in the periphery of the human cornea, and is thought to be pivotal in maintaining corneal biomechanical stability and curvature. However, it is unknown whether or not this key structural arrangement predominates throughout the entire corneal thickness or exists as a discrete feature at a particular tissue depth; or if it incorporates any elastic fibres and how, with respect to tissue depth, the circumcorneal annulus integrates with the orthogonally arranged collagen of the central cornea. To address these issues we performed a three-dimensional investigation of fibrous collagen and elastin architecture in the peripheral and central human cornea using synchrotron X-ray scattering and non-linear microscopy. This showed that the network of collagen fibrils circumscribing the human cornea is located in the posterior one-third of the tissue and is interlaced with significant numbers of mature elastic fibres which mirror the alignment of the collagen. The orthogonal arrangement of collagen in the central cornea is also mainly restricted to the posterior stromal layers. This information will aid the development of corneal biomechanical models aimed at explaining how normal corneal curvature is sustained and further predicting the outcome of surgical procedures.


Assuntos
Colágeno/fisiologia , Córnea/fisiologia , Tecido Elástico/fisiologia , Limbo da Córnea/fisiologia , Colágeno/metabolismo , Córnea/metabolismo , Tecido Elástico/metabolismo , Humanos , Técnicas In Vitro , Limbo da Córnea/metabolismo , Microscopia , Difração de Raios X
17.
Methods Mol Biol ; 2145: 231-247, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32542611

RESUMO

X-ray scattering enables the structure of collagen-rich tissues, such as the cornea, to be examined at both the molecular and fibrillar level. The high-intensity X-rays available at synchrotron radiation sources, coupled with minimal sample preparation requirements, facilitates the rapid generation of high-quality X-ray scattering data from corneal tissue at a close-to-physiological state of hydration. Analysis of resulting X-ray scatter patterns allows one to quantify numerous structural parameters relating to the average diameter, lateral arrangement and alignment of collagen fibrils within the cornea, as well as the axial and lateral arrangements of collagen molecules within the fibrils. Here we describe the typical experimental setup and considerations involved in the collection of X-ray scattering data from corneal tissue.


Assuntos
Córnea/ultraestrutura , Doenças da Córnea/diagnóstico , Testes Diagnósticos de Rotina/métodos , Difração de Raios X/métodos , Colágeno/isolamento & purificação , Colágeno/ultraestrutura , Doenças da Córnea/patologia , Humanos , Radiografia , Síncrotrons
18.
J Struct Biol ; 166(2): 195-204, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19258040

RESUMO

In the cornea, the precise organisation of fibrillar collagen and associated proteoglycans comprising the stromal extracellular matrix plays a major role in governing tissue form and function. Recently, abnormal collagen alignment was noted in the misshapen corneas of mature chickens affected by the retinopathy, globe enlarged (rge) mutation. Here we further characterize corneal ultrastructural changes as the rge eye develops post-hatch. Wide-angle X-ray scattering disclosed alteration to dominant collagen lamellae directions in the rge chick cornea, compared to age-matched controls. These changes accompanied eye globe enlargement and corneal flattening in affected birds, manifesting as a progressive loss of circumferential collagen alignment in the peripheral cornea and limbus in birds older than 1 month. Collagen intermolecular separation was unchanged in rge. However, small-angle X-ray scattering results suggest collagen fibril separation and diameter increase more rapidly towards the corneal periphery in rge at 3 months post-hatch compared to controls, although central collagen fibril diameter was unchanged. By transmission electron microscopy utilising cuprolinic blue stain, the morphology and distribution of stromal proteoglycans were unaltered in rge corneas otherwise demonstrating abnormal collagen fibril organisation. From a numerical simulation of tissue mechanics, progressive remodelling of stromal collagen in rge during globe enlargement post-hatch appears to be related to the corneal morphometric changes presented by the disease.


Assuntos
Córnea/patologia , Córnea/ultraestrutura , Doenças da Córnea/metabolismo , Doenças da Córnea/patologia , Doenças Retinianas/metabolismo , Doenças Retinianas/patologia , Animais , Galinhas , Colágeno/metabolismo , Simulação por Computador , Técnicas In Vitro , Microscopia Eletrônica de Transmissão , Espalhamento a Baixo Ângulo , Difração de Raios X/instrumentação , Difração de Raios X/métodos
19.
Mol Vis ; 15: 378-85, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19234631

RESUMO

PURPOSE: Structural changes are well known to occur in the cornea after injury. The aim of this study was to investigate collagen orientation changes in the cornea during a short-term wound healing process. METHODS: Seven bovine corneas were injured using a penetrating 5 mm biopsy punch and were subsequently organ cultured for up to two weeks. Six uninjured corneas acted as controls. The trephine wounded samples were snap frozen in liquid nitrogen either immediately after injury (0 h) or after 1 or 2 weeks in culture. Control/uninjured samples were snap frozen on arrival (0 h) or after 1 or 2 weeks in culture. Wide angle X-ray diffraction data were collected from each cornea at the UK Synchrotron Radiation Source or at the European Synchrotron Radiation Facility. Data analysis revealed information about collagen orientation and distribution in the corneal stroma during wound healing. For histology, two trephine wounded corneas at 0 h and 1 week and one control/uninjured cornea at 0 h were fixed in 10% neutral buffered formalin and processed for wax embedding. Wax sections were subsequently counterstained with haematoxylin and eosin to observe tissue morphology and the time course of complete re-epithelialization. RESULTS: Immediately after injury, collagen organization was altered in a small area inside the wound but remained similar to the control/uninjured sample in the remainder of the tissue. After one week, the trephine wounded corneas showed complete re-epithelialization and evidence of swelling while collagen adopted a radial arrangement inside and outside the wound. CONCLUSIONS: Remarkable changes in collagen fibril orientation were observed in trephine wounded corneas. Orientation changes immediately after wounding are likely to be due to the mechanical deformation of the tissue during the wounding process. However, tissue swelling and changes in collagen orientation at later stages probably reflect the processes of tissue repair. These differences will determine corneal stability and strength following trauma and possibly refractive surgery.


Assuntos
Córnea/patologia , Lesões da Córnea , Colágenos Fibrilares/ultraestrutura , Cicatrização , Animais , Bovinos , Córnea/metabolismo , Técnicas de Cultura de Órgãos , Fatores de Tempo , Ferimentos Penetrantes/metabolismo , Ferimentos Penetrantes/patologia , Difração de Raios X
20.
Exp Eye Res ; 88(5): 953-9, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19133259

RESUMO

Corneal collagen ultrastructural changes occur during the healing process. The present study was designed to compare collagen ultrastructural changes after trephine wounding or flap creation. Bovine corneas were injured and maintained in organ culture for up to 4 weeks. Samples were removed from culture at 0, 1, 2, 3 and 4 weeks and snap frozen in liquid N(2). X-ray scattering was used to measure changes in collagen interfibrillar spacing, intermolecular spacing and fibrillar diameter. Some samples were fixed in 10% Neutral Buffered Formalin solution and wax embedded for immunohistochemistry to monitor myofibroblast differentiation in corneal flaps. Swelling effects (i.e. changes in interfibrillar spacing) were more severe in trephined corneas than in those with stromal flaps. Collagen fibrillar diameter remained normal in the periphery of injured corneas, but increased significantly in areas within and around the wound in trephined samples and in the epithelial incision site in corneal flaps. Intermolecular spacing was unchanged in all samples. In the flaps, alphaSMA expression was only detected in an area adjacent to the epithelial plug, and cell numbers gradually increased during the culture. We conclude that stromal swelling is more rapid for trephine-wounded corneas than in stromal flaps, indicating that the intensity of the corneal healing response depends on the type of injury.


Assuntos
Colágeno/ultraestrutura , Substância Própria/fisiologia , Cicatrização/fisiologia , Animais , Bovinos , Diferenciação Celular/fisiologia , Substância Própria/lesões , Substância Própria/metabolismo , Fibroblastos/patologia , Técnicas de Cultura de Órgãos , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA