RESUMO
OBJECTIVE: This study aimed to investigate the feasibility and accuracy of non-radioactive TLN biopsy and TAD in routine clinical practice. BACKGROUND DATA: TAD involves TLN biopsy (TLNB) and sentinel lymph node biopsy and was recently introduced as a new standard for less invasive axillary staging in BC patients undergoing neoadjuvant systemic therapy (NST); however, clinical evidence is limited. METHODS: The SenTa study is a prospective registry study conducted at 50 centers. Patients with invasive BC who nderwent clip insertion into the most suspicious axillary lymph node were eligible. Axillary surgery was performed with or without sentinel lymph node biopsy, TLNB, and/or axillary lymph node dissection (ALND). Main endpoints were the detection rate and FNR of TLNB and TAD after NST. RESULTS: Between 2017 and 2018, 548 consecutive BC patients underwent clip placement into biopsy-confirmed positive lymph nodes. After NST (n = 473), the clipped TLN was intraoperatively resected in 329 of 423 patients [77.8%, 95% confidence interval (CI): 74.0-82.0]. TAD was successful in 199 of 229 patients (detection rate: 86.9%, 95% CI: 81.8-91.0), the SLN and TLN were identical in 129 patient (64.8%). FNRs were 7.2% (8 of 111, 95% CI: 3.1-13.6) for TLNB followed by ALND (n = 203) and 4.3% (2 of 46, 95% CI: 0.5-14.8) for TAD followed by ALND (n = 77). CONCLUSIONS: The SenTa study demonstrates the feasibility of TAD in a real-world cohort of BC patients. Our findings are of great importance for de-escalation of surgical strategies.
Assuntos
Neoplasias da Mama , Axila , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Humanos , Excisão de Linfonodo , Linfonodos/patologia , Linfonodos/cirurgia , Terapia Neoadjuvante , Estadiamento de Neoplasias , Sistema de Registros , Biópsia de Linfonodo SentinelaRESUMO
OBJECTIVE: There is ongoing debate whether cancer qualifies as traumatic stressor. We investigated prevalence and course of posttraumatic stress in patients with early breast cancer (BC) during their first year after diagnosis and determined effects of mastectomy and chemotherapy. METHODS: Patients with stage 0-III BC aged ≤65 years were evaluated with the Structured Clinical Interview for DSM-IV modules for acute and posttraumatic stress disorder (ASD and PTSD, respectively) before treatment, after chemotherapy, and 1 year after diagnosis. Matched controls were assessed at matched intervals. Effects of time, mastectomy, and chemotherapy on BC-related PTSD symptom severity were tested with linear mixed model analysis. RESULTS: Stress disorder (ASD or PTSD) related to BC was diagnosed in 6 (3.6%) of 166 patients before treatment and in 3 patients (2.0%) 1 year later. The rate of patients who experienced PTSD symptoms related to BC decreased from 82.5 to 57.3% (p < 0.001), and the mean of BC-related PTSD symptoms diminished from 3.1 to 1.7 (p < 0.001). Only university education significantly predicted the course of BC-related PTSD symptom severity (p = 0.009). In 60 controls, no diagnosis of stress disorder, a rate of 18% women experiencing PTSD symptoms, and a mean of 0.4 PTSD symptoms (p vs. patients <0.001) were found. CONCLUSIONS: Most newly diagnosed patients with BC experience PTSD symptoms, whereas full diagnoses of DSM-IV stress disorder are rare. Symptoms diminish somewhat within 1 year furthered by university education but independently from mastectomy and chemotherapy. Throughout the year after diagnosis, having BC entails markedly increased PTSD symptom burden. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Neoplasias da Mama/psicologia , Índice de Gravidade de Doença , Transtornos de Estresse Pós-Traumáticos/diagnóstico , Transtornos de Estresse Pós-Traumáticos/psicologia , Idoso , Neoplasias da Mama/diagnóstico , Manual Diagnóstico e Estatístico de Transtornos Mentais , Feminino , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos ProspectivosRESUMO
OBJECTIVES: Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. METHODS: We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. RESULTS: In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. CONCLUSIONS: On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. KEY POINTS: ⢠X-ray dark-field mammography provides significantly improved visualization of tumour features ⢠X-ray dark-field mammography is capable of outperforming conventional mammographic imaging ⢠X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Mamografia/métodos , Neoplasias da Mama/cirurgia , Feminino , Humanos , MastectomiaRESUMO
The introduction of mammography screening programs has significantly reduced breast cancer mortality rates. Nevertheless, some lesions remain undetected, especially in dense breast tissue. Studies have shown that phase-contrast imaging can improve breast cancer diagnosis by increasing soft tissue contrast. Furthermore, grating-based phase-contrast imaging enables the simultaneous acquisition of absorption, phase-contrast, and scattering, so-called dark-field images. The latter allows the classification of microcalcifications. In addition, breast computed tomography (BCT) systems can identify and discriminate overlapping but clinically relevant structures. This study investigates the benefit of combining grating-based phase-contrast with BCT. We explore the potential of grating-based phase-contrast breast computed tomography (gbpc-BCT) with a breast phantom and a freshly dissected fibroadenoma. Improved image contrast could be achieved with radiation doses comparable to those used in clinical BCT.
Assuntos
Neoplasias da Mama , Mamografia , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Feminino , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Mama/diagnóstico por imagem , Fibroadenoma/diagnóstico por imagemRESUMO
OBJECTIVE: Limited contrast between healthy and tumour tissue is a limiting factor in mammography and CT of the breast. Phase-contrast computed tomography (PC-CT) provides improved soft-tissue contrast compared with absorption-based techniques. In this study, we assessed the technical feasibility of grating-based PC-CT imaging of the breast for characterisation of ductal carcinoma in situ (DCIS). METHODS: Grating-based PC-CT was performed on one breast specimen containing an invasive ductal carcinoma and DCIS using monochromatic radiation of 23 keV. Phase-contrast and absorption-based images were compared qualitatively and quantitatively with histopathology in a blinded fashion. RESULTS: Grating-based PC-CT showed improved differentiation of soft-tissue components. Circular structures of high phase-shift contrast corresponding to the walls of the dilated ductuli of the DCIS were visualised with a contrast-to-noise ratio (CNR) of 9.6 using PC-CT but were not detectable on absorption-based images (CNR = 0.27). The high phase-shift structures of the dilated ductuli were identifiable in the PC-CT volume data set allowing for 3D characterisation of DCIS. CONCLUSIONS: Our results indicate that unlike conventional CT, grating-based PC-CT may allow the differentiation between invasive carcinoma and intraductal carcinoma and healthy breast tissue and provide 3D visualisation of DCIS.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Idoso , Biópsia por Agulha , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Meios de Contraste , Diagnóstico Diferencial , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Imuno-Histoquímica , Mamografia/métodos , Mastectomia/métodos , Intensificação de Imagem Radiográfica/métodos , Manejo de EspécimesRESUMO
OBJECTIVE: The evaluation of breast implants for rupture is currently the domain of ultrasound and MRI, while mammography is of very limited diagnostic value. Recently, specific visualisation of silicone has become feasible using dual-energy CT. Our objective was to evaluate whether it is feasible to identify silicone in breast implants by dual-energy CT and to reliably diagnose or rule out ruptures. METHODS: Seven silicone breast implant specimens were examined on dual-source CT at 100- and 140-kV tube potential with a 0.8-mm tin filter (collimation 128 × 0.6 mm, current-time products 165 and 140 mAsref with modulation, rotation time 0.28 s, pitch 0.55). Two patients scheduled for implant removal or replacement were examined with identical parameters. RESULTS: The silicone of the implant specimens showed a strong dual-energy signal. In one patient, both implants were intact, while a rupture was identified in the other patient. Ultrasound, MRI, surgical findings and histology confirmed the dual-energy CT diagnosis. CONCLUSION: Dual-energy CT may serve as an alternative technique for speedy evaluation of silicone breast implants. Specific clinical studies are required to determine the diagnostic accuracy and define indications for this technique.
Assuntos
Implante Mamário/métodos , Implantes de Mama , Mamografia/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Silicones/análise , Tomografia Computadorizada por Raios X/métodos , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Importance: The increasing use of neoadjuvant systemic therapy (NST) has led to substantial pathological complete response rates in patients with initially node-positive, early breast cancer, thereby questioning the need for axillary lymph node dissection (ALND). Targeted axillary dissection (TAD) is feasible for axillary staging; however, data on oncological safety are scarce. Objective: To assess 3-year clinical outcomes in patients with node-positive breast cancer who underwent TAD alone or TAD with ALND. Design, Setting, and Participants: The SenTa study is a prospective registry study and was conducted between January 2017 and October 2018. The registry includes 50 study centers in Germany. Patients with clinically node-positive breast cancer underwent clipping of the most suspicious lymph node (LN) before NST. After NST, the marked LNs and sentinel LNs were excised (TAD) followed by ALND according to the clinician's choice. Patients who did not undergo TAD were excluded. Data analysis was performed in April 2022 after 43 months of follow-up. Exposure: TAD alone vs TAD with ALND. Main Outcomes and Measures: Three-year clinical outcomes were evaluated. Results: Of 199 female patients, the median (IQR) age was 52 (45-60) years. A total of 182 patients (91.5%) had 1 to 3 suspicious LNs; 119 received TAD alone and 80 received TAD with ALND. Unadjusted invasive disease-free survival was 82.4% (95% CI, 71.5-89.4) in the TAD with ALND group and 91.2% (95% CI, 84.2-95.1) in the TAD alone group (P = .04); axillary recurrence rates were 1.4% (95% CI, 0-54.8) and 1.8% (95% CI, 0-36.4), respectively (P = .56). Adjusted multivariate Cox regression indicated that TAD alone was not associated with an increased risk of recurrence (hazard ratio [HR], 0.83; 95% CI, 0.34-2.05; P = .69) or death (HR, 1.07; 95% CI, 0.31-3.70; P = .91). Similar results were obtained for 152 patients with clinically node-negative breast cancer after NST (invasive disease-free survival: HR, 1.26; 95% CI, 0.27-5.87; P = .77; overall survival: HR, 0.81; 95% CI, 0.15-3.83; P = .74). Conclusions and Relevance: These results suggest that TAD alone in patients with mostly good clinical response to NST and at least 3 TAD LNs may confer survival outcomes and recurrence rates similar to TAD with ALND.
Assuntos
Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Neoplasias da Mama/cirurgia , Neoplasias da Mama/tratamento farmacológico , Terapia Neoadjuvante/métodos , Biópsia de Linfonodo Sentinela/métodos , Metástase Linfática/patologia , Excisão de Linfonodo/métodos , Linfonodos/patologia , AxilaRESUMO
INTRODUCTION: Due to the increasing use of dynamic breast MRI and the limited availability of MR-guided interventions, MRI-detected lesions usually undergo a second-look ultrasound (SLUS). We investigated the safety of a negative SLUS and a benign SLUS correlate in excluding malignant and high-risk lesions (B3) and evaluated criteria for the rate of detection on SLUS. METHODS: In the retrospective analysis, all breast MRIs performed between 2011 and 2013 were screened for newly detected lesions. We analyzed the SLUS detection rate dependent on breast density, mass character, lesion size, and histology. We calculated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of a negative and benign SLUS for malignant lesions (B5) and lesions requiring surgical excision (including high-risk and B5 lesions). RESULTS: We successfully correlated 110 of 397 lesions. The detection rate was significantly higher for mass than for non-mass lesions and correlated with lesion size for mass lesions only. Lesions without/with a benign SLUS correlate were more frequently benign (including B3) or required no further procedure (B2). The sensitivity of SLUS in the detection of B3 and B5 lesions was 58%, and 73% in the detection of B5 lesions. The NPV of a negative or benign SLUS for B3 and B5 lesions was 89%, and 96% for B5 lesions. DISCUSSION: SLUS is a safe diagnostic tool for the management of MRI-detected lesions and can spare patients from undergoing invasive procedures.
RESUMO
Purpose: Although the mortality rate of breast cancer was reduced with the introduction of screening mammography, many women undergo unnecessary subsequent examinations due to inconclusive diagnoses. Superposition of anatomical structures especially within dense breasts in conjunction with the inherently low soft tissue contrast of absorption images compromises image quality. This can be overcome by phase-contrast imaging. Approach: We analyze the spatial resolution of grating-based multimodal mammography using a mammographic phantom and one freshly dissected mastectomy specimen at an inverse Compton x-ray source. Here, the focus was on estimating the spatial resolution with the sample in the beam path and discussing benefits and drawbacks of the method used and the estimation of the mean glandular dose. Finally, the possibility of improving the spatial resolution is investigated by comparing monochromatic grating-based mammography with the standard one. Results: The spatial resolution is constant or also higher for the image acquired with monochromatic radiation and the contrast-to-noise ratio (CNR) is higher in our approach while the dose can be reduced by up to 20%. Conclusions: In summary, phase-contrast imaging helps to improve tumor detection by advanced diagnostic image quality. We demonstrate a higher spatial resolution for one mastectomy specimen and increased CNR at an equal or lower dose for the monochromatic measurements.
RESUMO
To assess ultrasound-guided vacuum-assisted biopsy (US-VAB) for selected problem cases and to report experiences with two different biopsy systems. Fifty-one lesions have been biopsied using the Mammotome (n = 24) or the Vacora (n = 27) system. Main indications: lesion in scarring (n = 5), complex cystic >or=8 mm (n = 7), increase in size (n = 10), architectural distortion (n = 4), uncharacteristic palpable abnormality (2), small size (n = 22), regional microcalcifications (n = 1). Results are verified by surgical excision (n = 10) or follow-up (n = 40). One patient was lost to follow-up. In four of the cases preceding core biopsy was inconclusive. four invasive carcinomas, two ductal carcinoma in situ (DCIS), three papillomas, six fibroadenomas, one adenosis tumor, one hamartoma, 10 complex cysts, 16 benign changes, three fat necroses, two granulomas, three unspecific inflammatory changes are verified. Surgery confirmed five malignancies, four benign changes, and converted one uncertain diagnosis (architectural distortion) from "inflammatory" to DCIS. Documented removal of all or most of the lesions correctly increased the level of confidence and open surgery could be avoided in 41/51 lesions. The two systems show different advantages and drawbacks. US-VAB may improve the level of confidence in selected difficult cases. Careful case selection and systematic retrospective correlation of imaging and histology remain crucial.
Assuntos
Doenças Mamárias/patologia , Mama/patologia , Biópsia/métodos , Mama/anatomia & histologia , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Doença da Mama Fibrocística/diagnóstico por imagem , Doença da Mama Fibrocística/patologia , Humanos , Necrose , Tamanho do Órgão , Radiografia , Ultrassonografia/métodos , VácuoRESUMO
BACKGROUND: The extent of intraductal carcinoma in situ (DCIS) is commonly underestimated due to the discontinuous growth and lack of microcalcifications. Specimen radiography has been established to reduce the rate of re-excision. However, the predictive value for margin assessment with conventional specimen radiography for DCIS is low. In this study we assessed the potential of grating-based phase-contrast computed tomography (GBPC-CT) at conventional X-ray sources for specimen tomography of DCIS containing samples. MATERIALS AND METHODS: GBPC-CT was performed on four ex-vivo breast specimens containing DCIS and invasive carcinoma of non-specific type. Phase-contrast and absorption-based datasets were manually matched with corresponding histological slices as the standard of reference. RESULTS: Matching of CT images and histology was successful. GBPC-CT showed an improved soft tissue contrast compared to absorption-based images revealing more histological details in the same sections. Non-calcifying DCIS exceeding the invasive tumor could be correlated to areas of dilated bright ducts around the tumor. CONCLUSIONS: GBPC-CT imaging at conventional X-ray sources offers improved depiction quality for the imaging of breast tissue samples compared to absorption-based imaging, allows the identification of diagnostically relevant tissue details, and provides full three-dimensional assessment of sample margins.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/cirurgia , Feminino , Humanos , Técnicas In Vitro , Mamografia/métodos , Microscopia de Contraste de Fase/métodos , Estudos ProspectivosRESUMO
Organizers of medical educational courses are often confronted with questions that are clinically relevant yet trespassing the frontiers of scientifically proven, evidence-based medicine at the point of care. Therefore, since 2007 organizers of breast teaching courses in German language met biannually to find a consensus in clinically relevant questions that have not been definitely answered by science. The questions were prepared during the 3 months before the meeting according to a structured process and finally agreed upon the day before the consensus meeting. At the consensus meeting, the open questions concerning 2D/3D mammography, breast ultrasound, MR mammography, interventions as well as risk-based imaging of the breast were presented first for electronic anonymized voting, and then the results of the audience were separately displayed from the expert votes. Thereafter, an introductory statement of the moderator was followed by pros/cons of two experts, and subsequently the final voting was performed. With ≥75% of votes of the expert panel, an answer qualified as a consensus statement. Seventeen consensus statements were gained, addressing for instance the use of 2D/3D mammography, breast ultrasound in screening, MR mammography in women with intermediate breast cancer risk, markers for localization of pathologic axillary lymph nodes, and standards in risk-based imaging of the breast. After the evaluation, comments from the experts on each field were gathered supplementarily. Methodology, transparency, and soundness of statements achieve a unique yield for all course organizers and provide solid pathways for decision making in breast imaging.
RESUMO
With the introduction of screening mammography, the mortality rate of breast cancer has been reduced throughout the last decades. However, many women undergo unnecessary subsequent examinations due to inconclusive diagnoses from mammography. Two pathways appear especially promising to reduce the number of false-positive diagnoses. In a clinical study, mammography using synchrotron radiation was able to clarify the diagnosis in the majority of inconclusive cases. The second highly valued approach focuses on the application of phase-sensitive techniques such as grating-based phase-contrast and dark-field imaging. Feasibility studies have demonstrated a promising enhancement of diagnostic content, but suffer from dose concerns. Here we present dose-compatible grating-based phase-contrast and dark-field images as well as conventional absorption images acquired with monochromatic x-rays from a compact synchrotron source based on inverse Compton scattering. Images of freshly dissected mastectomy specimens show improved diagnostic content over ex-vivo clinical mammography images at lower or equal dose. We demonstrate increased contrast-to-noise ratio for monochromatic over clinical images for a well-defined phantom. Compact synchrotron sources could potentially serve as a clinical second level examination.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/instrumentação , Mamografia/métodos , Mastectomia , Síncrotrons , Neoplasias da Mama/cirurgia , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação , Tolerância a Radiação , Raios XRESUMO
X-Ray Phase-Contrast (XPC) imaging is a novel technology with a great potential for applications in clinical practice, with breast imaging being of special interest. This work introduces an intuitive methodology to combine and visualize relevant diagnostic features, present in the X-ray attenuation, phase shift and scattering information retrieved in XPC imaging, using a Fourier domain fusion algorithm. The method allows to present complementary information from the three acquired signals in one single image, minimizing the noise component and maintaining visual similarity to a conventional X-ray image, but with noticeable enhancement in diagnostic features, details and resolution. Radiologists experienced in mammography applied the image fusion method to XPC measurements of mastectomy samples and evaluated the feature content of each input and the fused image. This assessment validated that the combination of all the relevant diagnostic features, contained in the XPC images, was present in the fused image as well.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Análise de Fourier , Processamento de Imagem Assistida por Computador/métodos , Mamografia/métodos , Adulto , Algoritmos , Feminino , Humanos , Reprodutibilidade dos Testes , Raios XRESUMO
Background: Cancer-related cognitive dysfunction has mostly been attributed to chemotherapy; this explanation, however, fails to account for cognitive dysfunction observed in chemotherapy-naïve patients. In a controlled, longitudinal, multisite study, we tested the hypothesis that cognitive function in breast cancer patients is affected by cancer-related post-traumatic stress. Methods: Newly diagnosed breast cancer patients and healthy control subjects, age 65 or younger, underwent three assessments within one year, including paper-and-pencil and computerized neuropsychological tests, clinical diagnostics of post-traumatic stress disorder (PTSD), and self-reported cognitive function. Analysis of variance was used to compare three groups of participants-patients who did or did not receive chemotherapy and healthy control subjects-on age- and education-corrected cognitive performance and cognitive change. Differences that were statistically significant after correction for false discovery rate were investigated with linear mixed-effects models and mediation models. All statistical tests were two-sided. Results: Of 226 participants (166 patients and 60 control subjects), 206 completed all assessment sessions (attrition: 8.8%). Patients demonstrated overall cognitive decline (group*time effect on composite z -score: -0.13, P = .04) and scored consistently worse on Go/Nogo errors. The latter effect was mediated by PTSD symptoms (mediation effect: B = 0.15, 95% confidence interval = 0.02 to 0.38). Only chemotherapy patients showed declined reaction time on a computerized alertness test. Overall cognitive performance correlated with self-reported cognitive problems at one year ( T = -0.11, P = .02). Conclusions: Largely irrespective of chemotherapy, breast cancer patients may encounter very subtle cognitive dysfunction, part of which is mediated by cancer-related post-traumatic stress. Further factors other than treatment side effects remain to be investigated.
Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/psicologia , Cognição/efeitos dos fármacos , Disfunção Cognitiva/etiologia , Transtornos de Estresse Pós-Traumáticos/complicações , Adulto , Idoso , Neoplasias da Mama/complicações , Neoplasias da Mama/epidemiologia , Estudos de Casos e Controles , Cognição/fisiologia , Feminino , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Testes Neuropsicológicos , Transtornos de Estresse Pós-Traumáticos/epidemiologia , Adulto JovemRESUMO
Breast microcalcifications play an essential role in the detection and evaluation of early breast cancer in clinical diagnostics. However, in digital mammography, microcalcifications are merely graded with respect to their global appearance within the mammogram, while their interior microstructure remains spatially unresolved and therefore not considered in cancer risk stratification. In this article, we exploit the sub-pixel resolution sensitivity of X-ray dark-field contrast for clinical microcalcification assessment. We demonstrate that the micromorphology, rather than chemical composition of microcalcification clusters (as hypothesised by recent literature), determines their absorption and small-angle scattering characteristics. We show that a quantitative classification of the inherent microstructure as ultra-fine, fine, pleomorphic and coarse textured is possible. Insights underlying the micromorphological nature of breast calcifications are verified by comprehensive high-resolution micro-CT measurements. We test the determined microtexture of microcalcifications as an indicator for malignancy and demonstrate its potential to improve breast cancer diagnosis, by providing a non-invasive tool for sub-resolution microcalcification assessment. Our results indicate that dark-field imaging of microcalcifications may enhance the diagnostic validity of current microcalcification analysis and reduce the number of invasive procedures.
Assuntos
Neoplasias da Mama/diagnóstico , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Mamografia , Microtomografia por Raio-XRESUMO
Differential phase-contrast X-ray imaging using a Talbot-Lau interferometer has recently shown promising results for applications in medical imaging. However, reducing the applied radiation dose remains a major challenge. In this study, we consider the realization of a Talbot-Lau interferometer in a high Talbot order to increase the signal-to-noise ratio for low-dose applications. The quantitative performance of π and π/2 systems at high Talbot orders is analyzed through simulations, and the design energy and X-ray spectrum are optimized for mammography. It is found that operation even at very high Talbot orders is feasible and beneficial for image quality. As long as the X-ray spectrum is matched to the visibility spectrum, the SNR continuously increases with the Talbot order for π-systems. We find that the optimal X-ray spectra and design energies are almost independent of the Talbot order and that the overall imaging performance is robust against small variations in these parameters. Discontinuous spectra, such as that from molybdenum, are less robust because the characteristic lines may coincide with minima in the visibility spectra; however, they may offer slightly better performance. We verify this hypothesis by realizing a prototype system with a mean fringe visibility of above 40% at the seventh Talbot order. With this prototype, a proof-of-principle measurement of a freshly dissected breast at reasonable compression to 4 cm is conducted with a mean glandular dose of only 3 mGy but with a high SNR.
RESUMO
OBJECTIVES: Neoadjuvant chemotherapy is the state-of-the-art treatment in advanced breast cancer. A correct visualization of the post-therapeutic tumor size is of high prognostic relevance. X-ray phase-contrast computed tomography (PC-CT) has been shown to provide improved soft-tissue contrast at a resolution formerly restricted to histopathology, at low doses. This study aimed at assessing ex-vivo the potential use of PC-CT for visualizing the effects of neoadjuvant chemotherapy on breast carcinoma. MATERIALS AND METHODS: The analysis was performed on two ex-vivo formalin-fixed mastectomy samples containing an invasive carcinoma removed from two patients treated with neoadjuvant chemotherapy. Images were matched with corresponding histological slices. The visibility of typical post-therapeutic tissue changes was assessed and compared to results obtained with conventional clinical imaging modalities. RESULTS: PC-CT depicted the different tissue types with an excellent correlation to histopathology. Post-therapeutic tissue changes were correctly visualized and the residual tumor mass could be detected. PC-CT outperformed clinical imaging modalities in the detection of chemotherapy-induced tissue alterations including post-therapeutic tumor size. CONCLUSIONS: PC-CT might become a unique diagnostic tool in the prediction of tumor response to neoadjuvant chemotherapy. PC-CT might be used to assist during histopathological diagnosis, offering a high-resolution and high-contrast virtual histological tool for the accurate delineation of tumor boundaries.
Assuntos
Antineoplásicos/farmacologia , Neoplasias da Mama/tratamento farmacológico , Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Antineoplásicos/uso terapêutico , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Terapia Neoadjuvante , Fixação de Tecidos , Resultado do TratamentoRESUMO
Phase-contrast mammography using laboratory X-ray sources is a promising approach to overcome the relatively low sensitivity and specificity of clinical, absorption-based screening. Current research is mostly centered on identifying potential diagnostic benefits arising from phase-contrast and dark-field mammography and benchmarking the latter with conventional state-of-the-art imaging methods. So far, little effort has been made to adjust this novel imaging technique to clinical needs. In this article, we address the key points for a successful implementation to a clinical routine in the near future and present the very first dose-compatible and rapid scan-time phase-contrast mammograms of both a freshly dissected, cancer-bearing mastectomy specimen and a mammographic accreditation phantom.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Humanos , Imagens de FantasmasRESUMO
Phase-contrast x-ray imaging is a promising improvement of conventional absorption-based mammography for early tumor detection. This potential has been demonstrated recently, utilizing structured gratings to obtain differential phase and dark-field scattering images. However, the inherently anisotropic imaging sensitivity of the proposed mono-directional approach yields only insufficient diagnostic information, and has low diagnostic sensitivity to highly oriented structures. To overcome these limitations, we present a two-directional x-ray phase-contrast mammography approach and demonstrate its advantages by applying it to a freshly dissected, cancerous mastectomy breast specimen. We illustrate that the two-directional scanning procedure overcomes the insufficient diagnostic value of a single scan, and reliably detects tumor structures, independently from their orientation within the breast. Our results indicate the indispensable diagnostic necessity and benefit of a multi-directional approach for x-ray phase-contrast mammography.