Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Opt Express ; 24(3): 2712-27, 2016 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-26906842

RESUMO

Pair creation by spontaneous parametric down-conversion (SPDC) has become a reliable source for single-photon states, used in many kinds of quantum information experiments and applications. In order to be spectrally pure, the two photons within a generated pair should be as frequency-uncorrelated as possible. For this purpose most experiments use narrow bandpass filters, having to put up with a drastic decrease in count rates. This article elaborates (theoretically and by numerical evaluation) the alternative method to engineer a setup such that the SPDC-generated quantum states are intrinsically pure. Using pulsed pump lasers and periodically poled crystals this approach makes bandpass filtering obsolete and allows for significantly higher output intensities and therefore count rates in the detectors. After numerically scanning all common wavelength regimes, polarisation configurations and three different non-linear crystals, we present a broad variety of setups which allow for an implementation of this method.

2.
Acta Oncol ; 55(11): 1299-1304, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27593107

RESUMO

BACKGROUND: Tumor hypoxia is associated with poor prognosis and outcome and can be visualized using 18F-MISO-positron emission tomography (PET) imaging. The goal of this study was to evaluate the correlation between biological markers and biological imaging in a group of patients in whom a correlation between biological imaging and outcome has previously been demonstrated. MATERIAL AND METHODS: In a prospective pilot project, 16 patients with locally advanced cancer of the head and neck underwent 18F-MISO-PET scans before and during primary radiochemotherapy in addition to 18F-FDG-PET and computed tomography (CT). Tumor biopsies were stained for three tissue-based markers (Ku80, CAIX, CD44); in addition, human papillomavirus (HPV) status was assessed. H-scores of marker expression were generated and the results were correlated with the biological imaging and clinical outcome. RESULTS: No statistically significant correlation was established between the H-scores for Ku80, CD44 and CAIX or between any of the H-scores and the imaging variables (tumor volume on 18F-FDG-PET in ml, hypoxic subvolume as assessed by 18F-MISO-PET in ml, and SUVmax tumor/SUVmean muscle during the 18F-MISO-PET). A statistically significant negative correlation was found between CD44 H-score and HPV status (p = .004). Cox regression analysis for overall survival and recurrence-free survival showed one significant result for CAIX being associated with improved overall survival [hazard ratio 0.96 (0.93-1.00), p = .047]. CONCLUSION: Expression of Ku80, CAIX and CD44 as assessed by immunohistochemistry of tumor biopsies were not correlated to one another or the biological imaging data. However, there was a significant influence of CAIX on overall survival and between CD44 and HPV.


Assuntos
Biomarcadores Tumorais/análise , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/terapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Biomarcadores Tumorais/metabolismo , Anidrase Carbônica IX/análise , Anidrase Carbônica IX/metabolismo , Carcinoma de Células Escamosas/mortalidade , Quimiorradioterapia/métodos , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/mortalidade , Humanos , Receptores de Hialuronatos/análise , Receptores de Hialuronatos/metabolismo , Imuno-Histoquímica , Autoantígeno Ku/análise , Autoantígeno Ku/metabolismo , Masculino , Pessoa de Meia-Idade , Misonidazol/análogos & derivados , Infecções por Papillomavirus/etiologia , Modelos de Riscos Proporcionais , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Hipóxia Tumoral
3.
J Nucl Med ; 65(4): 573-579, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423782

RESUMO

Our primary aim was to compare the therapeutic index (tumor-to-bone marrow and tumor-to-kidney absorbed-dose ratios) of the new radiolabeled somatostatin receptor antagonist [177Lu]Lu-DOTA-JR11 with the established radiolabeled somatostatin receptor agonist [177Lu]Lu-DOTATOC in the same patients with progressive, standard therapy-refractory meningioma. Methods: In this prospective, single-center, open-label phase 0 study (NCT04997317), 6 consecutive patients were included: 3 men and 3 women (mean age, 63.5 y). Patients received 6.9-7.3 GBq (standard injected radioactivity) of [177Lu]Lu-DOTATOC followed by 3.3-4.9 GBq (2 GBq/m2 × body surface area) of [177Lu]Lu-DOTA-JR11 at an interval of 10 ± 1 wk. In total, 1 [177Lu]Lu-DOTATOC and 2-3 [177Lu]Lu-DOTA-JR11 treatment cycles were performed. Quantitative SPECT/CT was done at approximately 24, 48, and 168 h after injection of both radiopharmaceuticals to calculate meningioma and organ absorbed doses as well as tumor-to-organ absorbed-dose ratios (3-dimensional segmentation approach for meningioma, kidneys, liver, bone marrow, and spleen). Results: The median of the meningioma absorbed dose of 1 treatment cycle was 3.4 Gy (range, 0.8-10.2 Gy) for [177Lu]Lu-DOTATOC and 11.5 Gy (range, 4.7-22.7 Gy) for [177Lu]Lu-DOTA-JR11. The median bone marrow and kidney absorbed doses after 1 treatment cycle were 0.11 Gy (range, 0.05-0.17 Gy) and 2.7 Gy (range, 1.3-5.3 Gy) for [177Lu]Lu-DOTATOC and 0.29 Gy (range, 0.16-0.39 Gy) and 3.3 Gy (range, 1.6-5.9 Gy) for [177Lu]Lu-DOTA-JR11, resulting in a 1.4 (range, 0.9-1.9) times higher median tumor-to-bone marrow absorbed-dose ratio and a 2.9 (range, 2.0-4.8) times higher median tumor-to-kidney absorbed-dose ratio with [177Lu]Lu-DOTA-JR11. According to the Common Terminology Criteria for Adverse Events version 5.0, 2 patients developed reversible grade 2 lymphopenia after 1 cycle of [177Lu]Lu-DOTATOC. Afterward, 2 patients developed reversible grade 3 lymphopenia and 1 patient developed reversible grade 3 lymphopenia and neutropenia after 2-3 cycles of [177Lu]Lu-DOTA-JR11. No grade 4 or 5 adverse events were observed at 15 mo or more after the start of therapy. The disease control rate was 83% (95% CI, 53%-100%) at 12 mo or more after inclusion. Conclusion: Treatment with 1 cycle of [177Lu]Lu-DOTA-JR11 showed 2.2-5.7 times higher meningioma absorbed doses and a favorable therapeutic index compared with [177Lu]Lu-DOTATOC after injection of 1.4-2.1 times lower activities. The first efficacy results demonstrated a high disease control rate with an acceptable safety profile in the standard therapy for refractory meningioma patients. Therefore, larger studies with [177Lu]Lu-DOTA-JR11 are warranted in meningioma patients.


Assuntos
Linfopenia , Neoplasias Meníngeas , Meningioma , Tumores Neuroendócrinos , Compostos Organometálicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Meníngeas/radioterapia , Meningioma/radioterapia , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/tratamento farmacológico , Octreotida/efeitos adversos , Compostos Organometálicos/efeitos adversos , Estudos Prospectivos , Radioisótopos/uso terapêutico , Receptores de Somatostatina
4.
EJNMMI Res ; 14(1): 37, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581480

RESUMO

BACKGROUND: A new generation of radiolabeled minigastrin analogs delivers low radiation doses to kidneys and are considered relatively stable due to less enzymatic degradation. Nevertheless, relatively low tumor radiation doses in patients indicate limited stability in humans. We aimed at evaluating the effect of sacubitril, an inhibitor of the neutral endopeptidase 1, on the stability and absorbed doses to tumors and organs by the cholecystokinin-2 receptor agonist [177Lu]Lu-PP-F11N in patients. In this prospective phase 0 study eight consecutive patients with advanced medullary thyroid carcinoma and a current somatostatin receptor subtype 2 PET/CT scan were included. Patients received two short infusions of ~ 1 GBq [177Lu]Lu-PP-F11N in an interval of ~ 4 weeks with and without Entresto® pretreatment in an open-label, randomized cross-over order. Entresto® was given at a single oral dose, containing 48.6 mg sacubitril. Adverse events were graded and quantitative SPECT/CT and blood sampling were performed. Absorbed doses to tumors and relevant organs were calculated. RESULTS: Pretreatment with Entresto® showed no additional toxicity and increased the stability of [177Lu]Lu-PP-FF11N in blood significantly (p < 0.001). Median tumor-absorbed doses were 2.6-fold higher after Entresto® pretreatment (0.74 vs. 0.28 Gy/GBq, P = 0.03). At the same time, an increase of absorbed doses to stomach, kidneys and bone marrow was observed, resulting in a tumor-to-organ absorbed dose ratio not significantly different with and without Entresto®. CONCLUSIONS: Premedication with Entresto® results in a relevant stabilization of [177Lu]Lu-PP-FF11N and consecutively increases radiation doses in tumors and organs. Trial registration clinicaltrails.gov, NCT03647657. Registered 20 August 2018.

5.
EJNMMI Phys ; 9(1): 26, 2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394263

RESUMO

BACKGROUND: Our aim was to determine sets of reconstruction parameters for the Biograph Vision Quadra (Siemens Healthineers) PET/CT system that result in quantitative images compliant with the European Association of Nuclear Medicine Research Ltd. (EARL) criteria. Using the Biograph Vision 600 (Siemens Healthineers) PET/CT technology but extending the axial field of view to 106 cm, gives the Vision Quadra currently an around fivefold higher sensitivity over the Vision 600 with otherwise comparable spatial resolution. Therefore, we also investigated how the number of incident positron decays-i.e., exposure-affects EARL compliance. This will allow estimating a minimal acquisition time or a minimal applied dose in clinical scans while retaining data comparability. METHODS: We measured activity recovery curves on a NEMA IEC body phantom filled with an aqueous 18F solution and a sphere to background ratio of 10-1 according to the latest EARL guidelines. Reconstructing 3570 image sets with varying OSEM PSF iterations, post-reconstruction Gaussian filter full width at half maximum (FWHM), and varying exposure from 59 kDecays/ml (= 3 s frame duration) to 59.2 MDecays/ml (= 1 h), allowed us to determine sets of parameters to achieve compliance with the current EARL 1 and EARL 2 standards. Recovery coefficients (RCs) were calculated for the metrics RCmax, RCmean, and RCpeak, and the respective recovery curves were analyzed for monotonicity. The background's coefficient of variation (COV) was also calculated. RESULTS: Using 6 iterations, 5 subsets and 7.8 mm Gauss filtering resulted in optimal EARL1 compliance and recovery curve monotonicity in all analyzed frames, except in the 3 s frames. Most robust EARL2 compliance and monotonicity were achieved with 2 iterations, 5 subsets, and 3.6 mm Gauss FWHM in frames with durations between 30 s and 10 min. RCpeak only impeded EARL2 compliance in the 10 s and 3 s frames. CONCLUSIONS: While EARL1 compliance was robust over most exposure ranges, EARL2 compliance required exposures between 1.2 MDecays/ml to 11.5 MDecays/ml. The Biograph Vision Quadra's high sensitivity makes frames as short as 10 s feasible for comparable quantitative images. Lowering EARL2 RCmax limits closer to unity would possibly even permit shorter frames.

6.
J Nucl Med ; 63(3): 476-484, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34301780

RESUMO

Our purpose was to evaluate the performance of the Biograph Vision Quadra PET/CT system. This new system is based on the Biograph Vision 600, using the same silicon photomultiplier-based detectors with 3.2 × 3.2 × 20 mm lutetium-oxoorthosilicate crystals. The 32 detector rings of the Quadra provide a 4-fold larger axial field of view (AFOV) of 106 cm, enabling imaging of major organs in 1 bed position. Methods: The physical performance of the scanner was evaluated according to the National Electrical Manufacturers Association NU 2-2018 standard, with additional experiments to characterize energy resolution. Image quality was assessed with foreground-to-background ratios of 4:1 and 8:1. Additionally, a clinical 18F-FDG PET study was reconstructed with varying frame durations. In all experiments, data were acquired using the maximum ring distance of 322 crystals (MRD 322), whereas image reconstructions could be performed with a maximum ring distance of only 85 crystals (MRD 85). Results: The spatial resolution at full width at half maximum in the radial, tangential, and axial directions was 3.3, 3.4, and 3.8 mm, respectively. The sensitivity was 83 cps/kBq for MRD 85 and 176 cps/kBq for MRD 322. The noise-equivalent count rates (NECRs) at peak were 1,613 kcps for MRD 85 and 2,956 kcps for MRD 322, both at 27.49 kBq/mL. The respective scatter fractions at peak NECR equaled 36% and 37%. The time-of-flight resolution at peak NECR was 228 ps for MRD 85 and 230 ps for MRD 322. Image contrast recovery ranged from 69.6% to 86.9% for 4:1 contrast ratios and from 77.7% to 92.6% for 8:1 contrast ratios reconstructed using point-spread function time of flight with 8 iterations and 5 subsets. Thirty-second frames provided readable lesion detectability and acceptable noise levels in clinical images. Conclusion: The Biograph Vision Quadra PET/CT device has spatial and time resolution similar to those of the Biograph Vision 600 but exhibits improved sensitivity and NECR because of its extended AFOV. The reported spatial resolution, time resolution, and sensitivity make it a competitive new device in the class of PET scanners with an extended AFOV.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador , Lutécio , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos
7.
Nat Commun ; 13(1): 7216, 2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36433960

RESUMO

Mammalian models of human disease are expensive and subject to ethical restrictions. Here, we present an independent platform for high-throughput screening, using larvae of the tobacco hornworm Manduca sexta, combining diagnostic imaging modalities for a comprehensive characterization of aberrant phenotypes. For validation, we use bacterial/chemical-induced gut inflammation to generate a colitis-like phenotype and identify significant alterations in morphology, tissue properties, and intermediary metabolism, which aggravate with disease progression and can be rescued by antimicrobial treatment. In independent experiments, activation of the highly conserved NADPH oxidase DUOX, a key mediator of gut inflammation, leads to similar, dose-dependent alterations, which can be attenuated by pharmacological interventions. Furthermore, the developed platform could differentiate pathogens from mutualistic gastrointestinal bacteria broadening the scope of applications also to microbiomics and host-pathogen interactions. Overall, larvae-based screening can complement mammals in preclinical studies to explore innate immunity and host-pathogen interactions, thus representing a substantial contribution to improve mammalian welfare.


Assuntos
Interações entre Hospedeiro e Microrganismos , Manduca , Animais , Humanos , Ensaios de Triagem em Larga Escala , Interações Hospedeiro-Patógeno , Inflamação , Larva , Mamíferos
8.
EJNMMI Phys ; 7(1): 22, 2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32323035

RESUMO

BACKGROUND: For multicenter clinical studies, PET/CT and SPECT/CT scanners need to be validated to ensure comparability between various scanner types and brands. This validation is usually performed using hollow phantoms filled with radioactive liquids. In recent years, 3D printing technology has gained increasing popularity for manufacturing of phantoms, as it is cost-efficient and allows preparation of phantoms of almost any shape. So far, however, direct 3D printing with radioactive building materials has not yet been reported. The aim of this work was to develop a procedure for preparation of 99mTc-containing building materials and demonstrate successful application of this material for 3D printing of several test objects. METHOD: The desired activity of a [99mTc]pertechnetate solution eluted from a 99Mo/99mTc-generator was added to the liquid 3D building material, followed by a minute amount of trioctylphosphine. The resulting two-phase mixture was thoroughly mixed. Following separation of the phases and chemical removal of traces of water, the radioactive building material was diluted with the required volume of non-radioactive building material and directly used for 3D printing. RESULTS: Using our optimized extraction protocol with trioctylphosphine as complex-forming phase transfer agent, technetium-99m was efficiently transferred from the aqueous 99Mo/99mTc-generator eluate into the organic liquid resin monomer. The observed radioactivity concentration ratio between the organic phase and the water phase was > 2000:1. The radioactivity was homogeneously distributed in the liquid resin monomer. We did not note differences in the 3D printing behavior of the radiolabeled and the unlabeled organic liquid resin monomers. Radio-TLC and SPECT studies showed homogenous 2D and 3D distribution of radioactivity throughout the printed phantoms. The radioactivity was stably bound in the resin, apart from a small amount of surface-extractable radioactivity under harsh conditions (ethanol at 50 °C). CONCLUSIONS: 3D printing of radioactive phantoms using 99mTc-containing building materials is feasible. Compared to the classical fillable phantoms, 3D printing with radioactive building materials allows manufacturing of phantoms without cold walls and in almost any shape. Related procedures with longer-lived radionuclides will enable production of phantoms for scanner validation and quality control.

9.
PLoS One ; 15(3): e0229560, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32176698

RESUMO

PURPOSE: Image texture is increasingly used to discriminate tissues and lesions in PET/CT. For quantification or in computer-aided diagnosis, textural feature analysis must produce robust and comparable values. Because statistical feature values depend on image count statistics, we investigated in depth the stability of Haralick features values as functions of acquisition duration, and for common image resolutions and reconstructions. METHODS: A homogeneous cylindrical phantom containing 9.6 kBq/ml Ge-68 was repeatedly imaged on a Siemens Biograph mCT, with acquisition durations ranging from three seconds to three hours. Images with 1.5, 2, and 4 mm isometrically spaced voxels were reconstructed with filtered back-projection (FBP), ordered subset expectation maximization (OSEM), and the Siemens TrueX algorithm. We analysed Haralick features derived from differently quantized (3 to 8-bit) grey level co-occurrence matrices (GLCMs) as functions of exposure E, which we defined as the product of activity concentration in a volume of interest (VOI) and acquisition duration. The VOI was a 50 mm wide cube at the centre of the phantom. Feature stability was defined for df/dE → 0. RESULTS: The most stable feature values occurred in low resolution FBPs, whereas some feature values from 1.5 mm TrueX reconstructions ranged over two orders of magnitude. Within the same reconstructions, most feature value-exposure curves reached stable plateaus at similar exposures, regardless of GLCM quantization. With 8-bit GLCM, median time to stability was 16 s and 22 s for FBPs, 18 s and 125 s for OSEM, and 23 s, 45 s, and 76 s for PSF reconstructions, with longer durations for higher resolutions. Stable exposures coincided in OSEM and TrueX reconstructions with image noise distributions converging to a Gaussian. In FBP, the occurrence of stable values coincided the disappearance of negatives image values in the VOI. CONCLUSIONS: Haralick feature values depend strongly on exposure, but invariance exists within defined domains of exposure. Here, we present an easily replicable procedure to identify said stable exposure domains, where image noise does not substantially add to textural feature values. Only by imaging at predetermined feature-invariant exposure levels and by adjusting exposure to expected activity concentrations, can textural features have a quantitative use in PET/CT. The necessary exposure levels are attainable by modern PET/CT systems in clinical routine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Algoritmos , Animais , Fluordesoxiglucose F18 , Humanos , Imagens de Fantasmas/estatística & dados numéricos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos
10.
Opt Express ; 17(25): 23153-9, 2009 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-20052243

RESUMO

We demonstrate a compact and stable source of polarization-entangled pairs of photons, one at 810 nm wavelength for high detection efficiency and the other at 1550 nm for long-distance fiber communication networks. Due to a novel Sagnac-based design of the interferometer no active stabilization is needed. Using only one 30 mm ppKTP bulk crystal the source produces photons with a spectral brightness of 1.13 x 10(6) pairs/s/mW/THz with an entanglement fidelity of 98.2%. Both photons are single-mode fiber coupled and ready to be used in quantum key distribution (QKD) or transmission of photonic quantum states over large distances.


Assuntos
Cor , Iluminação/instrumentação , Iluminação/métodos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Fótons
11.
Phys Med Biol ; 54(1): R1-25, 2009 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-19060363

RESUMO

In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.


Assuntos
Tomografia por Emissão de Pósitrons/métodos , Radioterapia/métodos , Proliferação de Células , Humanos , Hipóxia/diagnóstico por imagem , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Neoplasias/patologia , Neoplasias/radioterapia , Carga Tumoral
12.
J Comput Assist Tomogr ; 33(3): 475-80, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19478646

RESUMO

The amount and distribution of adipose tissue are important risk factors for different diseases. We present here a novel method with intrinsic water suppression (water-suppressed transition into driven equilibrium [TIDE]) and its application to healthy volunteers for fat volume and distribution evaluations. Water-suppressed TIDE revealed high image quality without artifacts, high signal-to-noise ratio of fat, and excellent suppression of water tissues, with an acquisition time of approximately 0.6 s/slice. Water-suppressed TIDE is a powerful tool for simple quantification of adipose tissue.


Assuntos
Tecido Adiposo/anatomia & histologia , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Humanos , Aumento da Imagem/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Nucl Med Commun ; 28(10): 789-97, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17728609

RESUMO

OBJECTIVE: To determine parameters of perfusion, distribution coefficient, and glucose metabolism as part of the tumour-specific micromilieu of breast cancer and compare them with corresponding values in normal breast tissue. METHODS: H2(15)O PET and 18F-FDG PET were performed on 10 patients with advanced invasive ductal carcinomas of the breast. Perfusion, distribution coefficient, and glucose metabolism and standardized uptake were quantified and analysed. RESULTS: Mean values based on the regions of interest were 59.2+/-43.9 ml x min(-1) x 100 g(-1) (perfusion), 0.58+/-0.26 ml x g(-1) (distribution coefficient), 7.76+/-6.10 (standardized uptake), and 5.4+/-2.5 mg x min(-1) x 100 g(-1) (glucose metabolism). The corresponding values for normal breast tissue were 22.1+/-13.2 ml x min x 100 g(-1) (perfusion), 0.16+/-0.05 ml x g(-1) (distribution coefficient), 0.33+/-0.07 (standardized uptake), and 0.18+/-0.08 mg x min x 100 g(-1) (glucose metabolism). For each tumour-normal tissue parameter pair, the mean values were significantly higher in tumours than normal breast tissue. Region-of-interest and pixel-wise correlation analysis revealed a positive association between glucose metabolism and distribution coefficient and glucose metabolism and perfusion for 7/10 tumours investigated. CONCLUSIONS: H2(15)O PET and 18F-FDG PET were able to differentiate breast cancer and normal breast tissue. The pixel-wise analysis revealed information about the heterogeneity of tumour fine structure in perfusion, distribution coefficient, and glucose metabolism, which may provide important guidelines for improving individual treatment.


Assuntos
Velocidade do Fluxo Sanguíneo , Neoplasias da Mama/fisiopatologia , Fluordesoxiglucose F18/farmacocinética , Glucose/metabolismo , Neovascularização Patológica/fisiopatologia , Radioisótopos de Oxigênio/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Distribuição Tecidual , Água/metabolismo
14.
Sci Rep ; 7(1): 7235, 2017 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-28775324

RESUMO

We demonstrate a new generation mechanism for polarisation- and colour-entangled photon pairs. In our approach we tailor the phase-matching of a periodically poled KTP crystal such that two downconversion processes take place simultaneously. Relying on this effect, our source emits entangled bipartite photon states, emerging intrinsically from a single, unidirectionally pumped crystal with uniform poling period. Its property of being maximally compact and luminous at the same time makes our source unique compared to existing photon-entanglement sources and is therefore of high practical significance in quantum information experiments.

15.
Med Phys ; 44(7): 3761-3766, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28494090

RESUMO

PURPOSE: Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS: RCs were obtained from PET/CT measurements of seven differently sized phantom spheres filled either with 18 F or with 68 Ga. RCs for the respective other isotope were then determined by two different methods: In the first method, images were convolved with positron range transconvolution functions derived from positron annihilation distributions found in literature. This method generated recasted images matching images using the respective other isotope. In the second method, the PET/CT system's isotope independent (intrinsic) point spread function was determined from said phantom measurements and convolved with numerical representations simulating hot spheres filled with the respective other isotope. These simulations included the isotope specific positron annihilation distributions. Recovered activity concentrations were compared between recasted images, simulated images, and the originally acquired images. RESULTS: 18 F and 68 Ga recovery was successfully determined from image acquisitions of the respective opposite isotope as well as from the simulations. 68 Ga RCs derived from 18 F data had a normalized root-mean-square deviation (NRMSD) from real 68 Ga measurements of 0.019% when using the first method and of 0.008% when using the second method. 18 F RCs derived from 68 Ga data had a NRMSD from real 18 F measurements of 0.036% when using the first method and of 0.038% when using the second method. CONCLUSIONS: Applying the principles of transconvolution, 18 F RCs can be recalculated from 68 Ga phantom measurements with excellent accuracy. The maximal additionally introduced error was below 0.4% of the error currently accepted for RCs in the site qualification of multicentre clinical trials by the EARL program of the European Association of Nuclear Medicine (EANM). Therefore, our methods legitimately allow for the use of long-lived solid state 68 Ge/68 Ga phantoms instead of manually prepared 18 F phantoms to characterize comparability of 18 F measurements across different imaging sites or of longitudinal 18 F measurements at a single PET/CT system.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Elétrons , Humanos , Tomografia por Emissão de Pósitrons
16.
Med Phys ; 44(4): 1558-1562, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28206679

RESUMO

PURPOSE: To determine the thyroid clearance effective half-life T with a common handheld electronic dosimeter (ED) in patients undergoing radioiodine treatment for hyperthyroidism. METHODS: Dose rates from 12 inpatients were measured daily with an ED and with a clinical uptake counter. The ED was attached to the patient with two different setups, one using a cervical collar and another employing a neck strap. Estimation of T was performed by linear regression analysis of the log of both the ED and the uptake counter measurements versus time. The latter provided the reference data. RESULTS: Based on repeated neck strap dose rate measurements, individual Ts were determined with clinically required accuracy. The mean difference from the reference method equaled to -0.09 ± 0.35 days. CONCLUSIONS: Determination of individual T is feasible with a common handheld ED using the simple and easy to instruct neck strap measurement setup. This simple method complements stationary uptake counter measurements and thus may improve the accuracy of radioiodine treatment planning by adding an individual T for dose calculation.


Assuntos
Equipamentos e Provisões Elétricas , Radiometria/instrumentação , Glândula Tireoide/metabolismo , Meia-Vida , Humanos , Hipertireoidismo/metabolismo , Hipertireoidismo/radioterapia , Radioisótopos do Iodo/metabolismo , Radioisótopos do Iodo/uso terapêutico , Glândula Tireoide/efeitos da radiação
17.
Eur J Radiol ; 85(9): 1627-36, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27501899

RESUMO

AIMS: To assess incremental and total patient exposure from clinical SPECT/CT imaging by means of effective dose estimations with regards to different protocols and SPECT/CT systems. MATERIALS AND METHODS: Consecutive patient exposure levels were documented prospectively from SPECT/CT operations at three European imaging centers. Documentation included the volume-weighted computed tomography (CT) dose index, the CT dose length product (DLP) and the amount of applied radiopharmaceutical. SPECT/CT examinations were categorized regionally into head, neck, myocardium, thorax, abdomen, extremities and whole-body. Effective dose from the CT (EDCT) was estimated from the DLP using gender specific conversion factors. EDSPECT was estimated from the injected activity levels and corresponding conversion factors (ICRP 106). RESULTS: This study included 678 SPECT/CT examinations. EDCT per indication and EDSPECT per tracer ranged from 0.01mSv to 7.4mSv and from 1.1mSv to 12.2mSv, respectively. In general, EDSPECT contributed most to overall patient exposure. Total EDSPECT/CT averaged across all protocol categories was 6.7mSv. CONCLUSION: Total patient exposure from clinical SPECT/CT is 7mSv on average. Individual dose levels vary with the clinical indication and on-site protocol parameters.


Assuntos
Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Compostos Radiofarmacêuticos/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Áustria , Radiação de Fundo , Carga Corporal (Radioterapia) , Protocolos Clínicos , Humanos , Masculino , Doses de Radiação , Radiometria , Compostos Radiofarmacêuticos/administração & dosagem , Suíça , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos
18.
Med Phys ; 43(10): 5767, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27782715

RESUMO

PURPOSE: A PET/CT system's imaging capabilities are best described by its point spread function (PSF) in the spatial domain or equivalently by its modulation transfer function (MTF) in the spatial frequency domain. Knowing PSFs or MTFs is a prerequisite for many numerical methods attempting to improve resolution and to reduce the partial volume effect. In PET/CT, the observed PSF is a convolution of the system's intrinsic imaging capabilities including image reconstruction (PSF0) and the positron range function (PRF) of the imaged ß+ emitting isotope. A PRF describes the non-Gaussian distribution of ß+ annihilation events around a hypothetical point source. The main aim was to introduce a new method for determining a PET/CT system's intrinsic MTF (MTF0) from phantom measurements of hot spheres independently of the ß+ emitting isotope used for image acquisition. Secondary aim was to examine non-Gaussian and nonlinear MTFs of a modern iterative reconstruction algorithm. METHODS: PET/CT images of seven phantom spheres with volumes ranging from 0.25 to 16 ml and filled either with 18F or with 68Ga were acquired and reconstructed using filtered back projection (FBP). MTFs were modeled with linear splines. The spline fit iteratively minimized the mean squared error between the acquired PET/CT image and a convolution of the thereof derived PSF with a numerical representation of the imaged hot phantom sphere. For determining MTF0, the numerical sphere representations were convolved with a PRF, simulating a fill with either 18F or 68Ga. The MTFs determined by this so-called MTF fit method were compared with MTFs derived from point source measurements and also compared with MTFs derived with a previously published PSF fit method. The MTF fit method was additionally applied to images reconstructed by a vendor iterative algorithm with PSF recovery (Siemens TrueX). RESULTS: The MTF fit method was able to determine 18F and 68Ga dependent MTFs and MTF0 from FBP reconstructed images. Root-mean-square deviation between fit determined MTFs and point source determined MTFs ranged from 0.023 to 0.039. MTFs from Siemens TrueX reconstructions varied with size of the imaged sphere. CONCLUSIONS: MTF0 can be determined regardless of the imaged isotope, when using existing PRF models for the MTF fit method presented. The method proves that modern iterative PET/CT reconstruction algorithms have nonlinear imaging properties. This behaviour is not accessible by point source measurements. MTFs resulting from these clinically applied algorithms need to be estimated from objects of similar geometry to those intended for clinical imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Isótopos
19.
Radiother Oncol ; 117(1): 113-7, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26432067

RESUMO

PURPOSE: The aim was to assess changes of tumour hypoxia during primary radiochemotherapy (RCT) for head and neck cancer (HNC) and to evaluate their relationship with treatment outcome. MATERIAL AND METHODS: Hypoxia was assessed by FMISO-PET in weeks 0, 2 and 5 of RCT. The tumour volume (TV) was determined using FDG-PET/MRI/CT co-registered images. The level of hypoxia was quantified on FMISO-PET as TBRmax (SUVmaxTV/SUVmean background). The hypoxic subvolume (HSV) was defined as TV that showed FMISO uptake ⩾1.4 times blood pool activity. RESULTS: Sixteen consecutive patients (T3-4, N+, M0) were included (mean follow-up 31, median 44months). Mean TBRmax decreased significantly (p<0.05) from 1.94 to 1.57 (week 2) and 1.27 (week 5). Mean HSV in week 2 and week 5 (HSV2=5.8ml, HSV3=0.3ml) were significantly (p<0.05) smaller than at baseline (HSV1=15.8ml). Kaplan-Meier plots of local recurrence free survival stratified at the median TBRmax showed superior local control for less hypoxic tumours, the difference being significant at baseline and after 2weeks (p=0.031, p=0.016). CONCLUSIONS: FMISO-PET documented that in most HNC reoxygenation starts early during RCT and is correlated with better outcome.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/complicações , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Estudos de Viabilidade , Feminino , Radioisótopos de Flúor , Neoplasias de Cabeça e Pescoço/complicações , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Hipóxia/diagnóstico por imagem , Hipóxia/etiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Resultado do Tratamento , Carga Tumoral
20.
Clin Nucl Med ; 28(11): 929-30, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14578714

RESUMO

A 74-year-old man with prostate cancer was screened for bone metastases. The scan exhibited severe degenerative skeletal changes (especially in the spine and the right knee) and catheter drainage of the bladder, but obviously no bone metastases. Surprisingly, 2 almost symmetric "devil-like"-looking lesions were noted in the frontolateral skull. The patient was treated with bilateral bore hole trepanation because of a subdural hematoma 3 weeks earlier. The lesions can be interpreted as augmented bone metabolism in these regions. Although subdural hematoma is fairly common (incidence, 15:100,000 annually), bilateral trepanation is only performed in approximately 5% of patients.


Assuntos
Osso e Ossos/diagnóstico por imagem , Difosfonatos , Hematoma Subdural/diagnóstico por imagem , Compostos de Organotecnécio , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Hematoma Subdural/cirurgia , Humanos , Masculino , Neoplasias da Próstata/patologia , Cintilografia , Compostos Radiofarmacêuticos , Crânio/diagnóstico por imagem , Trepanação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA