Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
HIV Med ; 21(10): 650-658, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32876389

RESUMO

OBJECTIVES: The characteristics of critically ill HIV-positive patients and the causes of their admission to intensive care units (ICUs) are only known through retrospective and unicentric studies. This study aims to fill this knowledge gap. METHODS: This is a prospective, multicentre cohort study of short- and medium-term prognostic factors. The setting consisted of ICUs of three tertiary referral hospitals from the three largest metropolitan areas in Brazil in the period January 2014 to November 2015. In all, 161 HIV patients over 18 years old were included. RESULTS: The clinical data of the outcomes (ICU mortality, hospital mortality and 90-day survival) were extracted from medical records using the REDCap®ï¸ web-based form and analysed with the MedCalc®ï¸ application. Median age was 41.7 [interquartile range (IQR): 34-50] years, the Simplified Acute Physiologic Score 3 (SAPS 3) was 64 (IQR: 56-74), and the Sequential Organ Failure Assessment Score (SOFA) was 6 (IQR: 4-9) points. The main causes of admission were sepsis (54.5%) and acute respiratory failure (13.7%). ICU and hospital mortality rates were 32.3% and 40.4%, respectively. In a multivariate analysis, time until ICU admission ≥ 3 days (P = 0.0013), performance status (Eastern Cooperative Oncology Group score, P = 0.0344), coma (Glasgow Coma Scale ≤ 8 points, P = 0.0213) and sepsis (P = 0.0003) were associated with increased hospital mortality. Coma (P = 0.0002) and sepsis (P = 0.0008) were independently associated with 90-day survival. CONCLUSIONS: Delayed ICU admission and the severity of critical illness determine the short- and medium-term mortality rates of HIV-infected patients admitted to the ICU, rather than factors associated with HIV infection. These results suggest that prognostic factors of HIV-infected patients in the ICU are similar to those of non-HIV-infected populations.


Assuntos
Estado Terminal/mortalidade , Infecções por HIV/mortalidade , Insuficiência Respiratória/epidemiologia , Sepse/epidemiologia , Adulto , Idoso , Brasil/epidemiologia , Cuidados Críticos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/estatística & dados numéricos , Prognóstico , Estudos Prospectivos , Insuficiência Respiratória/mortalidade , Sepse/mortalidade
2.
Med J Malaysia ; 75(5): 555-560, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32918426

RESUMO

INTRODUCTION: Hyperhidrosis is a disorder of excessive and uncontrollable sweating beyond the body's physiological needs. It can be categorised into primary or secondary hyperhidrosis based on its aetiology. Detailed history review including onset of symptoms, laterality of disease and family history are crucial which may suggest primary hyperhidrosis. Secondary causes such as neurological diseases, endocrine disorders, haematological malignancies, neuroendocrine tumours and drugs should be adequately examined and investigated prior to deciding on further management. The diagnosis of primary hyperhidrosis should only be made only after excluding secondary causes. Hyperhidrosis is a troublesome disorder that often results in social, professional, and psychological distress in sufferers. It remains, however, a treatment dilemma among some healthcare providers in this region. METHODS: The medical records and clinical outcomes of 35 patients who underwent endoscopic thoracic sympathectomy for primary hyperhidrosis from 2008 to 2018 in Department of Cardiothoracic Surgery were reviewed. RESULTS: The mean age of the patients was 27±10.1years, with male and female distribution of 18 and 17, respectively. Fifty-one percent of patients complained of palmar hyperhidrosis, while 35% of them had concurrent palmaraxillary and 14% had palmar-plantar-axillary hyperhidrosis. Our data showed that 77% (n=27) of patients were not investigated for secondary causes of hyperhidrosis, and they were not counselled on the non-surgical therapies. All patients underwent single-staged bilateral endoscopic thoracic sympathectomy. There was resolution of symptoms in all 35 (100%) patients with palmar hyperhidrosis, 13(76%) patients with axillary hyperhidrosis and only 2 (50%) patients with plantar hyperhidrosis. Postoperatively 34.3% (n=12) of patients reported compensatory hyperhidrosis. There were no other complications such as pneumothorax, chylothorax, haemothorax and Horner's Syndrome. CONCLUSION: Clinical evaluation of hyperhidrosis in local context has not been well described, which may inadvertently result in the delay of appropriate management, causing significant social and emotional embarrassment and impair the quality of life of the subjects. Detailed clinical assessment and appropriate timely treatment, be it surgical or non-surgical therapies, are crucial in managing this uncommon yet distressing disease.


Assuntos
Endoscopia , Hiperidrose/diagnóstico , Hiperidrose/cirurgia , Satisfação do Paciente , Simpatectomia/métodos , Toracoscopia/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Auditoria Médica , Prontuários Médicos , Avaliação de Resultados em Cuidados de Saúde , Adulto Jovem
3.
Opt Express ; 26(25): 33245-33252, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30645480

RESUMO

For an efficient single-photon source a high-count rate into a well-defined spectral and spatial mode is desirable. Here we have developed a hybrid planar Fabry-Pérot microcavity by using a two-photon polymerization process (2PP) where coupling between single-photon sources (diamond colour centres) and resonance modes is observed. The first step consists of using the 2PP process to build a polymer table structure around previously characterized nitrogen-vacancy (NV) centres on top of a distributed Bragg reflector (DBR) with a high reflectivity at the NV zero-phonon line (ZPL). Afterwards, the polymer structure is covered with a silver layer to create a weak (low Q) cavity where resonance fluorescence measurements from the NVs are shown to be in good agreement with analytical and Finite Difference Time Domain (FDTD) results.

4.
J Int Med Res ; 38(1): 242-52, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20233536

RESUMO

This study was designed to assess the clinical effect of a home-based telephone intervention in Chinese heart failure patients. A total of 550 Chinese heart failure patients were enrolled into either (i) a group that received the usual standard of care (UC group); or (ii) a group that received a home-based heart failure centre management programme using nursing specialist-led telephone consultations (HFC group). The impact of the home-based intervention on admission rate, admission length and medical costs over 6 months was measured. Although the mean left ventricular ejection fraction in HFC patients was 29.3% compared with 34.8% in UC patients, the home-based intervention resulted in a significantly lower all-cause admission rate per person (HFC 0.60 +/- 0.77 times/person; UC 0.96 +/- 0.85 times/person), a shorter all-cause hospital stay (reduced by 8 days per person) and lower total 6-month medical costs (reduced by US$2682 per patient). These results suggest that the home-based intervention with nursing specialist-led telephone consultations may improve the clinical outcome and provide cost-savings for Chinese patients with heart failure.


Assuntos
Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca Sistólica/economia , Insuficiência Cardíaca Sistólica/enfermagem , Serviços Hospitalares de Assistência Domiciliar/economia , Avaliação de Resultados em Cuidados de Saúde/economia , Povo Asiático , Estudos de Casos e Controles , Análise Custo-Benefício , Feminino , Seguimentos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Estudos Prospectivos , Taxa de Sobrevida , Telemedicina , Telefone
5.
Int J Clin Pract ; 62(4): 555-61, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18067561

RESUMO

BACKGROUND: In ST-segment elevation acute myocardial infarction (STEMI), dislodgement of thrombus within the culprit artery during primary percutaneous coronary intervention (PCI) may cause distal embolisation and impaired myocardial reperfusion. Clinical results of thromboembolic protection strategies have been controversial. We conducted this study to investigate whether the benefit of thrombus removal is time dependent. METHODS: Seventy-four STEMI patients within 12 h from onset were randomised to receive either primary PCI with initial thrombosuction (IT) or standard strategy. Results were analysed in subgroups according to the onset-to-lab time intervals (subgroup 1: 0-240 min, subgroup 2: 241-480 min and subgroup 3: 481-720 min). RESULTS: The primary end-points were improvements in thrombolysis in myocardial infarction flow (DeltaTIMI) and myocardial blush grade (DeltaMBG) postprocedure. Better DeltaTIMI (2.2 +/- 1.1 vs. 1.5 +/- 1.3, p = 0.014) and DeltaMBG (2.3 +/- 1.1 vs. 1.0 +/- 1.5, p < 0.001) were observed in IT patients, compared with standard PCI patients. In onset-to-lab time subgroup analysis, the difference between IT and standard PCI is significant only in subgroup 2 (DeltaTIMI 2.6 +/- 1.0 vs. 1.3 +/- 1.2, p = 0.007; DeltaMBG 2.6 +/- 0.9 vs. 1.0 +/- 1.1, p = 0.010), but not in the other two subgroups. CONCLUSIONS: This prospective randomised study shows that primary PCI with IT may improve epicardial flow and myocardial reperfusion in patients with STEMI, and this benefit is the most significant in patients treated within 4-8 h after symptom onset.


Assuntos
Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Reperfusão Miocárdica/métodos , Angioplastia Coronária com Balão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sucção/métodos , Trombectomia/métodos , Fatores de Tempo
6.
J Int Med Res ; 36(5): 1077-84, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18831904

RESUMO

This study evaluated the efficacy and safety of use of the Angio-Seal vascular closure device deployment for early ambulation (2 h) after elective percutaneous coronary intervention in 143 consecutive patients receiving either intravenous low-dose enoxaparin (0.5 mg/kg) or unfractionated heparin (UFH). The initial success rate of Angio-Seal(trade mark) deployment was 98.6%, with no significant difference between the UFH group (98.9%) and the enoxaparin group (98.0%). In-hospital and clinic outcomes were evaluated in the 141 patients with successful Angio-Seal deployment. During hospitalization, there were no deaths, myocardial infarction, urgent target vessel revascularization or bleeding events in either group; three patients in the UFH group and none in the enoxaparin group had minor vascular complications (differences not significant). In clinic follow-up, two patients in the UFH group and none in the enoxaparin group had major vascular complications (differences not significant). Routine use of the Angio-Seal(trade mark) for early ambulation in patients receiving intravenous low-dose enoxaparin compared with UFH provides promising efficacy and safety for daily practice.


Assuntos
Angioplastia Coronária com Balão , Anticoagulantes/uso terapêutico , Deambulação Precoce , Enoxaparina/uso terapêutico , Técnicas Hemostáticas , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Artéria Femoral/cirurgia , Técnicas Hemostáticas/instrumentação , Heparina/análogos & derivados , Heparina/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Cancer Res ; 41(2): 532-6, 1981 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-6449995

RESUMO

The prophage lambda cIts857 induction test with Escherichia coli K12 envA uvrB as the lysogen has been successfully applied to the screening of sparingly water-soluble carcinogens that have been dissolved in dimethyl sulfoxide and metabolically activated with liver enzymes induced either with Aroclor 1254 or phenobarbital. Growth of noninduced lysogenic cells during the test was suppressed with ampicillin, with resultant increase of sensitivity of the test. The maximum inducing activity observed was about 50% of the complete induction level attained with water-soluble carcinogens that did not require metabolic activation. High sensitivity was achieved with the use of the lambda cIts857 prophage strain. In several instances where the Ames Salmonella-microsome test has failed to confirm the carcinogenicity of the respective carcinogens, this induction test has provided a better correlation. Of the carcinogens tested, only one false negative, namely, cyclophosphamide, was encountered. In contrast, the use of the wild-type prophage lambda strain resulted in low sensitivity. The adoption of the endolysin assay technique for the assessment of induction has greatly simplified the procedures and has permitted the screening test to be performed quickly and economically.


Assuntos
Bacteriófago lambda/genética , Carcinógenos/farmacologia , Lisogenia/efeitos dos fármacos , Testes de Mutagenicidade/métodos , Mutação , Relação Estrutura-Atividade , Temperatura
8.
Am J Cardiol ; 76(10): 652-6, 1995 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-7572619

RESUMO

In 24 patients with chronic coronary artery disease, dobutamine stress echocardiography (DSE) was performed within 2 days before and after successful elective percutaneous transluminal coronary angioplasty (PTCA) in a blinded fashion. Patients with ischemic response on DSE before PTCA had significant improvement in the global peak-dose DSE score index after PTCA (1.62 +/- 0.35 to 1.40 +/- 0.29, p < 0.001), whereas patients without ischemic response had no improvement. The positive and negative predictive values of pre-PTCA DSE on early myocardial ischemia relief after angioplasty were 93% and 80%, respectively. In patients showing contractility recruitment during low-dose dobutamine infusion in the DSE before PTCA, there was significant improvement in the global resting wall motion score index in the DSE after PTCA (1.48 +/- 0.43 to 1.34 +/- 0.33, p = 0.004), while patients without contractility recruitment showed no improvement. Again, the positive and negative predictive values of pre-PTCA DSE on early hibernation recovery following angioplasty were 80% and 89%, respectively. In conclusion, DSE in patients with chronic, stable coronary artery disease accurately predicts wall motion improvement after successful angioplasty, and the expected improvement is safely demonstrated early after the procedure.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Dobutamina , Contração Miocárdica , Adulto , Idoso , Análise de Variância , Distribuição de Qui-Quadrado , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Ecocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
9.
Am J Cardiol ; 86(3): 293-8, 2000 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-10922436

RESUMO

Previous studies have shown that ultrasonic integrated backscatter is valuable in characterizing stunned myocardium. Recent investigations have demonstrated that resting cardiac cycle-dependent variation of integrated backscatter closely paralleled the contractile reserve in patients with chronic left ventricular ischemic dysfunction. The purpose of this study was to validate whether ultrasonic tissue characterization (UTC) compared with dobutamine stress echocardiography (DSE) and thallium-201 stress-reinjection single-photon emission computed tomography (Tl-SPECT) could predict reversible myocardial dyssynergy in patients with chronic coronary artery disease. Forty-eight patients with stable coronary artery disease underwent UTC, DSE, and Tl-SPECT simultaneously before successful coronary revascularization and were followed up with echocardiograms at rest >3 months later. Among the 58 investigated segments, the weighted amplitude, a composite parameter derived from the integrated backscatter power curve, was larger for those groups with greater functional recovery (p <0.001). For the persistent akinetic segments, the weighted amplitudes were small with large deviations of the nadir ratios that represented the asynchrony between the intramural contractile events and the global systole. Using the cut-off value 2.0 of the weighted amplitude, the sensitivity and specificity for predicting functional improvement after revascularization were both 82.8% (kappa = 0.66) and comparable to the sensitivity and specificity of DSE and Tl-SPECT. UTC, delineating the myocardial physical state and intramural contraction, can be a novel approach in predicting functional improvement of chronic dyssynergy after revascularization.


Assuntos
Cardiotônicos , Doença das Coronárias/terapia , Dobutamina , Ecocardiografia , Contração Miocárdica/fisiologia , Revascularização Miocárdica , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico , Adulto , Idoso , Doença das Coronárias/diagnóstico , Doença das Coronárias/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
10.
Am J Cardiol ; 84(2): 125-9, 1999 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-10426326

RESUMO

The clinical significance of stress-induced ST-segment elevation and T-wave pseudonormalization in infarct-related leads is still controversial. Therefore, we conducted the present study to assess this issue using simultaneous dobutamine stress echocardiography (DSE) and thallium-201 single-photon emission computed tomography. A total of 119 patients with Q-wave myocardial infarction were enrolled in this study. There were 58 patients with (group I) and 61 patients without (group II) dobutamine-induced ST-T changes. Left ventricular ejection fraction was 43 +/- 13% in group I and 49 +/- 14% in group II (p <0.05). The baseline, low-, and peak-dose global wall motion scores were similar between these 2 groups (26.2 +/- 6.1 vs 26.2 +/- 6.3 [p = NS]; 24.1 +/- 5.3 vs 23.5 +/- 5.7 [p = NS]; 26.4 +/- 5.7 vs 26.7 +/- 6.1 [p = NS]). The sensitivity, specificity, and accuracy of these ST-T changes for detecting residual myocardial viability and ischemia documented by DSE in all patients were 50%, 53%, and 51% (for viability), and 47%, 48%, and 47% (for ischemia), respectively. The sensitivity, specificity, and accuracy of these ST-T changes for detecting a reversible perfusion defect documented by thallium-201 single-photon emission computed tomography were 51%, 54%, and 52%, respectively. In conclusion, dobutamine-induced ST elevation and/or T-wave pseudonormalization is associated with poor resting left ventricular function. These ST-T changes are not associated with residual myocardial ischemia and viability in the infarct area. Therefore, these electrocardiographic changes alone cannot be reliably considered as distinctive markers in formulating the therapeutic strategy of coronary intervention.


Assuntos
Cardiotônicos , Dobutamina , Ecocardiografia/efeitos dos fármacos , Teste de Esforço/efeitos dos fármacos , Infarto do Miocárdio/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Radioisótopos de Tálio
11.
J Virol Methods ; 39(1-2): 125-38, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1331144

RESUMO

The types of Kunjin virus-specified proteins present in purified Vero cell plasma membrane were studied. Immunofluorescence of unfixed Kunjin virus-infected whole cell monolayers, indicated that two structural proteins (envelope and prM) and three non-structural proteins (NS1, 3 and 5) were found at the plasma membrane. There was no obvious progressive accumulation of the observed antigens over the time periods between 8 to 24 h p.i. Thus SDS-PAGE analysis was performed using purified radiolabelled Vero cell plasma membranes. From the protein profiles, all five antigens detected by immunofluorescent staining were also present. In addition, two smaller molecular weight non-structural proteins NS4B and NS2B were also observed. Generally, all the non-structural proteins found in the purified plasma membranes were of the same molecular weights as those found in infected whole cell lysate. Interestingly, both the structural proteins, i.e., envelope (E) and prM proteins in the plasma membrane sample were of higher molecular weights as compared to the counterparts in the infected whole cell lysate. The envelope protein of purified extracellular Kunjin virus was also lower in molecular weight compared to the same protein in the plasma membrane.


Assuntos
Antígenos Virais/isolamento & purificação , Flavivirus/imunologia , Virologia/métodos , Animais , Membrana Celular/imunologia , Membrana Celular/microbiologia , Eletroforese em Gel de Poliacrilamida , Estudos de Avaliação como Assunto , Imunofluorescência , Células Vero , Proteínas Virais/imunologia , Proteínas Virais/isolamento & purificação
12.
Heart ; 80(1): 80-5, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9764066

RESUMO

OBJECTIVE: To develop new electrocardiographic (ECG) criteria for the differentiation between counterclockwise and clockwise atrial flutters. BACKGROUND: Traditionally, the ECG differentiation between counterclockwise and clockwise atrial flutters is based on the flutter wave polarity in the inferior leads. However, determination of flutter wave polarity is subjective and sometimes difficult, especially in flutter waves of undulating pattern. PATIENTS: The study comprised 37 consecutive patients with drug resistant atrial flutter; 30 had counterclockwise and 17 had clockwise atrial flutter (10 had both forms of atrial flutter). The isthmus dependence was confirmed by entrainment study and catheter ablation. The ECG patterns of both types of atrial flutter were compared and the flutter wave polarity in the inferior leads was determined by four independent cardiologists. RESULTS: The flutter wave polarity in the inferior leads appeared negative in 24, positive in one, and equivocal in five of the counterclockwise atrial flutters; polarity appeared negative in one, positive in 10, and equivocal in six of the clockwise atrial flutters. However, the aVF/lead I flutter wave amplitude ratio was > 2.5 in all counterclockwise but < 2.5 in all clockwise atrial flutters. The flutter wave nadirs in the inferior leads corresponded to the upstrokes in V1 in all counterclockwise atrial flutters, but corresponded to the downstrokes in V1 in all clockwise atrial flutters. CONCLUSIONS: The flutter wave polarity in the inferior leads does not correlate well with the flutter wave rotating direction. However, counterclockwise and clockwise atrial flutters can be differentiated by new ECG criteria with high accuracy.


Assuntos
Flutter Atrial/diagnóstico , Eletrocardiografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Flutter Atrial/cirurgia , Ablação por Cateter , Diagnóstico Diferencial , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Estatísticas não Paramétricas
13.
Anticancer Res ; 19(6C): 5607-10, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10697626

RESUMO

BACKGROUND: The purpose of this study was to evaluate the effect of weight changes after completion of chemotherapy on the prognosis and survival of patients with intermediate and high grade non-Hodgkin's lymphoma. MATERIALS AND METHODS: A retrospective analysis of data on patients from the TCOG T1488 protocol, a phase II study using CHOP in the treatment of intermediate and high grade lymphoma. From September, 1988 to December 1994, 138 adult patients had complete weight data for analysis. Weight gain in lymphoma patients after therapy significantly correlated with improved survival (Logrank test p = .0031). In patients with initial B symptoms, weight gain after therapy correlated with survival (Logrank test p = .0039), female patients (odds ratio = 6.2) were less likely to gain weight on treatment. CONCLUSION: Weight gain after chemotherapy for lymphoma is a significant positive prognostic factor for survival.


Assuntos
Peso Corporal , Linfoma não Hodgkin/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Linfoma não Hodgkin/diagnóstico , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
14.
Ultrasound Med Biol ; 27(9): 1191-8, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11597359

RESUMO

We conducted a study to delineate the alterations in the cyclic changes of myocardial ultrasonic integrated backscatter (IBS) in patients receiving angioplasty for chronic coronary artery disease. Ultrasonic tissue characterization (UTC) and dobutamine stress echocardiography were performed in 43 patients before and 24 h after angioplasty, as well as before the follow-up angiography 3 months later. For segments being normokinetic with ischemic burden, the blunted amplitude and increased nadir deviation of IBS cyclic modulation recovered soon after angioplasty. For dyssynergic segments with contractile reserve, the angioplasty rebuilt the amplitude before the wall motion recovered, but corrected the nadir deviation tardily. In both circumstances, the coronary restenosis abolished the initial restoration. Those nonviable segments persistently revealed large deviations and small weighted amplitudes irrelevant to coronary lesions. The progress of myocardial ischemia, the development of wall motion dyssynergy and, then, the loss of viability, show different patterns of alterations in UTC after alleviating coronary obstructions.


Assuntos
Angioplastia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Ecocardiografia , Contração Miocárdica/fisiologia , Idoso , Doença Crônica , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Estudos Transversais , Ecocardiografia sob Estresse , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia
15.
Ultrasound Med Biol ; 26(9): 1413-20, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11179615

RESUMO

Ultrasonic tissue characterization with integrated backscatter is an objective method to quantitatively define the physical state of the myocardium. To determine if backscatter imaging during inotropic stimulation could be used objectively to determine the myocardial viability and ischemia in patients with ischemic heart disease, the backscatter changes were examined in 23 patients with myocardial infarction during dobutamine stress two-dimensional (2-D) echocardiography. Coronary angiography was performed within 1 to 2 days after the stress test. The results of this study demonstrated that changes in backscatter variability correlated significantly with the wall motion changes in stress echocardiography during dobutamine infusion (p < 0.0001). In addition, it was shown that the backscatter changes were significantly different in various types of myocardial tissue. In 23 healthy control segments, the ultrasonic backscatter variability was preserved and unchanged during inotropic stimulation (p = NS). In 15 viable infarct zones, restoration or an increase in backscatter variability during low-dose dobutamine infusion was noted, this being lost when ischemia developing during high-dose dobutamine infusion (p < 0.01). In 9 nonviable infarct zones, the phase-weighted variation was usually < or = 0 and did not change significantly during inotropic stimulation, regardless of the patency of the infarct-related arteries. In 15 remote ischemic myocardial zones, the backscatter variability was preserved at the baseline level, did not change during low-dose dobutamine infusion, but decreased significantly during high-dose dobutamine stress (p < 0.01). In conclusion, dobutamine stress tissue characterization could offer an objective approach for the detection of myocardial viability and ischemia, and might be a useful adjunct to the conventional stress echocardiography.


Assuntos
Cardiotônicos , Dobutamina , Ecocardiografia , Contração Miocárdica/efeitos dos fármacos , Infarto do Miocárdio/diagnóstico por imagem , Angiografia Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Estimulação Química
16.
Ultrasound Med Biol ; 26(2): 341-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10722924

RESUMO

The abnormal spatial distribution of intraventricular flow is superior to clinical and two-dimensional (2-D) echocardiographic variables in predicting left ventricular thrombosis after myocardial infarction. Echocardiography was prospectively performed in 79 patients within 72 h after anterior wall myocardial infarction onset and repeated before discharge. The apical rotating flow pattern in color flow map was recognized as abnormal. By power Doppler echocardiography, the moving blood could generate speckle tracking images to delineate the intraventricular flow. A swirling flow pattern indicating the compartmentalization of left ventricular blood flow with some blood stagnant in the apical dyssynergic area was identified. The flow pattern shown by the speckle tracking image was superior to the color-flow map in correlating with left ventricular thrombosis. It implicated that the more the detail in which we can describe the blood flow pathway, the more information we can realize.


Assuntos
Ecocardiografia Doppler de Pulso , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Trombose/fisiopatologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Diagnóstico Diferencial , Feminino , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Trombose/diagnóstico por imagem , Trombose/etiologia , Pressão Ventricular
17.
Ultrasound Med Biol ; 24(8): 1107-20, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9833578

RESUMO

The identification of viable myocardium and residual ischemia in patients with acute myocardial infarction has important prognostic implications. The ultrasonic tissue characterization with integrated backscatter and dobutamine-atropine stress echocardiography were performed 8.3+/-3 days after AMI in 30 patients. After coronary angioplasty for the residual stenosis of infarct-related artery, both modalities were repeated. The parameter obtained from ultrasonic tissue characterization, phase-weighted variation, could differentiate the myocardium with residual coronary stenosis or nonviable myocardium from the viable myocardium without residual coronary stenosis (p < 0.001). Using the cutoff value of 5.8 dB, the sensitivity, specificity and accuracy for detecting viable myocardium without residual coronary stenosis were 75%, 100% and 90.2%, respectively. The phase-weighted variation of the viable infarction zone restored after the coronary stenosis was relieved. In contrast, the nonviable myocardium had a small phase-weighted variation that was irrelevant to the patency of the infarct-related artery. The ultrasonic tissue characterization may be used in identifying patients with acute myocardial infarction whose infarction zones are viable without residual ischemia.


Assuntos
Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Angioplastia , Atropina , Angiografia Coronária , Doença das Coronárias/terapia , Dobutamina , Eletrocardiografia , Teste de Esforço , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Terapia Trombolítica
18.
Ultrasound Med Biol ; 25(8): 1185-93, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10576261

RESUMO

Alterations of ultrasonic backscatter parameters have been evident in humans with myocardial infarction or ischemia. The backscatter variability could be restored in ischemic or stunned myocardium after reperfusion. The aims of this study were to determinate changes in regional myocardial ultrasonic backscatter during intra-aortic balloon counterpulsation (IABP) support in patients with acute myocardial infarction (AMI), and to evaluate whether backscatter imaging could be a functional guide of IABP support. A total of 9 patients with AMI were investigated during IABP support with a two-dimensional (2-D) ultrasonic backscatter imaging approach for parasternal short-axis view. Coronary angiography was performed in 6 of the 9 patients. A total of 21 vessel territories were studied in different modes of IABP support: 1:1, 1:2 and standby. Restoration of cyclic variation of backscatter after IABP support was demonstrated in 10 vessel territories. Failure of restoration of cyclic variation of backscatter after IABP support was noted in 6 vessel territories with severe coronary lesions (total or nearly total occlusion) or scar tissue. No changes of the ultrasonic backscatter were found in nonischemic vessel territories with patent coronary arteries or TIMI III coronary flow. In addition, the wall motion score did not change significantly with different IABP support. These results suggest that IABP could restore the cyclic variation of backscatter in ischemic myocardium. Myocardial anisotropy may play an influential role in the alterations of ultrasonic backscatter. We propose that ultrasonic backscatter could be a noninvasively functional guide of IABP use in patients with AMI.


Assuntos
Ecocardiografia , Balão Intra-Aórtico , Infarto do Miocárdio/diagnóstico por imagem , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Contração Miocárdica , Infarto do Miocárdio/terapia , Reprodutibilidade dos Testes
19.
Ultrasound Med Biol ; 24(2): 187-96, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9550177

RESUMO

The ultrasonic integrated backscatter of myocardium changes in infarction and ischemia. On the third day after acute myocardial infarction, 30 patients underwent ultrasonic tissue characterization from the parasternal short-axis view. With a composite parameter, the phase-weighted variation, sensitivity, specificity, and accuracy for diagnosing multivessel coronary artery disease were 84.6%, 52.9% and 66.6%, respectively. Using 67 degrees as the cutoff value for the phase deviation of the backscatter power curve, the recanalization of the infarct-related artery could be detected with a positive predictive value of 77.7% and a negative predictive value of 66.6%. Ultrasonic tissue characterization is a feasible technique for detecting the multivessel coronary artery diseases and the recanalization of infarct-related artery for patients with acute myocardial infarction. The diminished cardiac cycle-dependent variation in integrated backscatter and increased phase deviation can differentiate patent coronary arteries from those coronary arteries with anatomically significant stenoses.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Idoso , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Ultrasound Med Biol ; 27(2): 171-9, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11316525

RESUMO

Cardiomyocyte hypertrophy and interstitial fibrin deposition develop in cardiac allografts and contribute to the functional changes of transplanted hearts. We hypothesized that integrated backscatter (IBS) can detect these myocardial changes. A total of 32 heart transplant recipients with either no or mild acute rejection (International Society of Heart and Lung Transplantation grade IA) were enrolled in this study. IBS data of myocardium were collected immediately before simultaneous dobutamine stress echocardiography (DSE) and (201)thallium imaging. Coronary angiography and endomyocardial biopsy were also performed. Coronary angiography showed diffuse narrowing in 1 patient who also had abnormal results of IBS, DSE, and thallium results. In the other 31 patients with patent coronary arteries, there were 3 patients (10%) with abnormal DSE results, 19 patients (61%) with abnormal IBS patterns, and 16 patients (52%) with reversible thallium perfusion defects. Of the patients, 44% had cardiomyocyte hypertrophy and 56% interstitial fibrin deposition. There were significant differences in the prevalence of (201)thallium perfusion defects and serum cyclosporine levels between patients with and without abnormal IBS patterns. Pathologic changes were also associated with abnormal IBS patterns (p = 0.01). However, there was no association between abnormal IBS and DSE results. By multiple logistic regression analysis, the abnormal IBS patterns were associated inversely with serum cyclosporine level (p = 0.028). In conclusion, abnormal IBS patterns are associated significantly with perfusion heterogeneity and pathologic changes in heart transplant recipients without evident acute myocardial rejection. There is no association between abnormal IBS patterns and dobutamine-induced dyssynergy in these patients. IBS provides a noninvasive approach for detection of myocardial changes in transplanted hearts without evident acute rejection.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Transplante de Coração , Cateterismo Cardíaco , Cardiotônicos , Distribuição de Qui-Quadrado , Doença das Coronárias/fisiopatologia , Dobutamina , Ecocardiografia , Teste de Esforço , Feminino , Transplante de Coração/efeitos adversos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA