Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 405(23): 7241-50, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23831828

RESUMO

This paper describes a metrological approach to evaluate the measurement capability of laboratories participating in two proficiency testing (PT) programmes involving the analysis of five polycyclic aromatic hydrocarbons (PAHs) in sediment samples. Reference values of PAHs in the programmes for performance assessment were obtained from an accurate isotope dilution gas chromatography mass spectrometry (ID-GCMS) method which was thoroughly validated and verified. Isotope dilution mass spectrometry (IDMS) technique usually has a well-defined measurement uncertainty budget and a traceability link to an International System of Units. Provision of the metrological reference values in PT enables the establishment of a technical platform to assess the actual competence of the participating laboratories in sediment PAHs analysis. Results of the PT programmes showed that about 80 % of the laboratories employed gas chromatography in their analyses and the remaining used liquid chromatography. Irrespective of the techniques being used, however, the majority of the participating laboratories were observed to underestimate values in which the mean values of the five reported PAHs were less than those of the ID-GCMS-derived reference values by 13-20 %. Only 41-44 % of the participating laboratories were able to achieve satisfactory z-scores. The present study revealed that the reinforcement of the capability for accurate measurement of PAHs in sediment samples in laboratories worldwide should be addressed.

2.
Biosens Bioelectron ; 21(7): 1101-6, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-15886000

RESUMO

A bi-enzyme-based Clark electrode was developed for the determination of 3-hydroxybutyrate. This sensor is based on the specific dehydrogenation by 3-hydroxybutyrate dehydrogenase (HBDH, E.C. 1.1.1.30) in combination with salicylate hydroxylase (SHL E.C. 1.14.13.1). The enzymes were entrapped by a poly(carbamoyl) sulfonate (PCS) hydrogel on a Teflon membrane. The principle of the determination scheme is as follows: the specific detecting enzyme, HBDH, catalyses the specific dehydrogenation of 3-hydroxybutyrate consuming NAD(+). The products, NADH, initiate the irreversible decarboxylation and the hydroxylation of salicylate by SHL in the presence of oxygen. SHL forces the equilibrium of dehydrogenation of 3-hydroxybutyrate by HBDH to the product side by consuming NADH. Dissolved oxygen acts as an essential material for SHL during its enzymatic reactions. This results in a detectable signal due to the SHL-enzymatic consumptions of dissolved oxygen in the measurement of 3-hydroxybutyrate. Interferences from different amino acids and electroactive substances were found to be minimal due to the specificity of HBDH and the application of a Teflon membrane. The sensor has a fast response (2s) and short recovery time (2 min) with a linear range between 8 and 800 microM 3-hydroxybutyrate and a detection limit of 3.9 microM. A good agreement (R(2)=0.9925) with theoretical calculation was obtained in spiked serum sample measurements.


Assuntos
Ácido 3-Hidroxibutírico/sangue , Ácido 3-Hidroxibutírico/química , Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Hidroxibutirato Desidrogenase/química , Oxigenases de Função Mista/química , Transdutores , Técnicas Biossensoriais/métodos , Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Biosens Bioelectron ; 19(12): 1745-52, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15142609

RESUMO

A novel trienzyme sensor for the amperometric determination of lactate was constructed by immobilizing salicylate hydroxylase (SHL, E.C. 1.14.13.1), l-lactate dehydrogenase (LDH, E.C. 1.1.1.27), and pyruvate oxidase (PyOD, E.C. 1.2.3.3) on a Clark-type oxygen electrode. The enzymes were entrapped by a poly(carbamoyl) sulfonate (PCS) hydrogel on a Teflon membrane. LDH catalyzes the specific dehydrogenation of lactate consuming NAD(+). SHL catalyzes the irreversible decarboxylation and the hydroxylation of salicylate in the presence of oxygen and NADH produced by LDH. PyOD decarboxylates pyruvate using oxygen and phosphate. SHL and PyOD force the equilibrium of dehydrogenation of lactate by LDH to the product side by consuming NADH and pyruvate, respectively. Dissolved oxygen acts as an essential material for both PyOD and SHL during their respective enzymatic reactions. Therefore, an amplified signal, caused by the consumptions of dissolved oxygen by the two enzymes, was observed in the measurement of lactate. Regeneration of cofactor was found in the trienzyme system. A Teflon membrane was used to fabricate the sensor in order to avoid interferences. The sensor has a fast response (2s) and short recovery times (2 min). The total test time for a measurement by using this lactate sensor (4 min) was faster than using a commercial lactate testing kit (up to 10 min). The sensor has a linear range between 10 and 400 microM lactate, with a detection limit of 4.3 microM. A good agreement (R2 = 0.9984) with a commercial lactate testing kit was obtained in beverage sample measurements.


Assuntos
Técnicas Biossensoriais/instrumentação , Carbamatos/química , Eletroquímica/instrumentação , Ácido Láctico/análise , Ácido Láctico/química , Oxirredutases/química , Poliésteres/química , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Enzimas Imobilizadas/química , Análise de Falha de Equipamento , Hidrogéis/química , Concentração de Íons de Hidrogênio , Complexos Multienzimáticos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Chromatogr A ; 1218(39): 6907-13, 2011 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-21872867

RESUMO

A new certified reference material (CRM) of melamine in milk GLHK-11-02 was developed aiming to address the great demand from the testing community after the melamine crises. The material was prepared by adding an appropriate quantity of melamine into the skimmed milk samples and the final product was in the form of fine lyophilized powder. Characterization of the material relied on two newly developed gravimetric isotope dilution mass spectrometry (IDMS) methods, one using liquid chromatography-tandem mass spectrometry (LC-MS/MS) and another gas chromatography-mass spectrometry (GC-MS). Experimental parameters with crucial effects on the performance of the two IDMS methods were thoroughly investigated. These included purity of standard used, equilibration time of isotopes, efficiency of extraction methods as well as possible interferences from the matrix and melamine analogues. Precision was found to be excellent with a coefficient of variation of 2.5% for the LC-IDMS/MS (n=46) and 1.9% for the GC-IDMS (n=30) respectively. Using one-tail Student's t-test at 95% confidence interval, analytical data sets generated from the two methods were found to exhibit no significant difference. Measurement accuracy of the methods was further verified through an Asia Pacific Metrology Program (APMP) pilot study. Analytical results of the present LC-IDMS/MS for the two milk test samples at the concentration level of about 0.45 and 3.5 mg kg(-1) were proven to be very good. There were excellent overlaps between our results and the assigned reference values, and the absolute deviation was less than 3.2%. Both the LC-IDMS/MS and GC-IDMS methods were shown to be sufficiently reliable and accurate for certification of the melamine CRM. Certified value of melamine in dry mass fraction in GLHK-11-02 was 1.14 mg kg(-1). Expanded uncertainty due to sample inhomogeneity, long term and short term stability and variability in the characterization procedure was at 7.1% or 0.08 mg kg(-1). The CRM is primarily used to provide a complete method validation for and to improve the technical competence of melamine analysis to food and chemical testing laboratories.


Assuntos
Espectrometria de Massas/métodos , Leite/química , Leite/normas , Triazinas/análise , Animais , Isótopos de Carbono , Cromatografia Líquida , Análise de Alimentos/métodos , Análise de Alimentos/normas , Cromatografia Gasosa-Espectrometria de Massas , Padrões de Referência , Espectrometria de Massas em Tandem , Triazinas/química
5.
Anal Biochem ; 343(2): 263-7, 2005 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15993373

RESUMO

An amperometric biosensor was constructed for analysis of human salivary phosphate without sample pretreatment. The biosensor was constructed by immobilizing pyruvate oxidase (PyOD) on a screen-printed electrode. The presence of phosphate in the sample causes the enzymatic generation of hydrogen peroxide (H(2)O(2)), which was monitored by a potentiostat and was in proportion to the concentration of human salivary phosphate. The sensor shows response within 2s after the addition of standard solution or sample and has a short recovery time (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 to 625 microM phosphate with a detection limit of 3.6 microM. A total of 50 salivary samples were collected for the determination of phosphate. A good level of agreement (R(2)=0.9646) was found between a commercial phosphate testing kit and the phosphate sensor. This sensor maintained a high working stability (>85%) after 12h operation and required only a simple operation procedure. The amperometric biosensor using PyOD is a simple and accurate tool for rapid determinations of human salivary phosphate, and it explores the application of biosensors in oral and dental research and diagnosis.


Assuntos
Técnicas Biossensoriais/métodos , Fosfatos/análise , Saliva/química , Carbamatos/química , Eletroquímica , Enzimas Imobilizadas/química , Polímeros de Fluorcarboneto/química , Humanos , Peróxido de Hidrogênio/química , Fosfatos/química , Poliésteres/química , Piruvato Oxidase/química , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Fatores de Tempo
6.
Appl Microbiol Biotechnol ; 66(4): 377-83, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15300421

RESUMO

A screen-printed phosphate biosensor based on immobilized pyruvate oxidase (PyOD, E.C. 1.2.3.3) has been developed for monitoring phosphate concentrations in a sequencing batch reactor (SBR) system. The enzyme was immobilized by a nafion matrix and covered a poly(carbamoyl) sulfonate (PCS) hydrogel on a screen-printed electrode. PyOD consumes phosphate in the presence of pyruvate and oxygen and generates hydrogen peroxide (H2O2), carbon dioxide and acetylphosphate. The electroactive H2O2, monitored at +420 mV vs Ag/AgCl, is generated in proportion to the concentration of phosphate. The sensor has a fast response time (2 s) and a short recovery period (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 microM to 625 microM phosphate with a detection limit of 3.6 microM. There was good agreement (R2=0.9848) between the commercial phosphate testing kit and the phosphate sensor in measurements of synthetic wastewater in a SBR system. This sensor maintained a high working stability (>85%) after 12 h of operation and involved a simple operation procedure. It therefore serves as a useful tool for rapid and accurate phosphate measurements in the SBR system and probably for process control.


Assuntos
Técnicas Biossensoriais , Fosfatos/análise , Piruvato Oxidase , Reatores Biológicos , Enzimas Imobilizadas , Esgotos/análise , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA