Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
NMR Biomed ; : e5201, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38863271

RESUMO

Quantitative analysis of diffusion-weighted magnetic resonance imaging (DW-MRI) has been explored for many clinical applications since its development. In particular, the intravoxel incoherent motion (IVIM) model for DW-MRI has been commonly utilized in various organs. However, because of the presence of excessive noise, the IVIM parameter maps obtained from pixel-wise fitting are often unreliable. In this study, we propose a kernelized total difference-based curve-fitting method to estimate the IVIM parameters. Simulated DW-MRI data at five signal-to-noise ratios (i.e., 10, 20, 30, 50, and 100) and real abdominal DW-MRI data acquired on a 1.5-T MRI scanner with nine b-values (i.e., 0, 10, 25, 50, 100, 200, 300, 400, and 500 s/mm2) and six diffusion-encoding gradient directions were used to evaluate the performance of the proposed method. The results were compared with those obtained by three existing methods: trust-region reflective (TRR) algorithm, Bayesian probability (BP), and deep neural network (DNN). Our simulation results showed that the proposed method outperformed the other three comparing methods in terms of root-mean-square error. Moreover, the proposed method could preserve small details in the estimated IVIM parameter maps. The experimental results showed that, compared with the TRR method, the proposed method as well as the BP (and DNN) method could reduce the overestimation of the pseudodiffusion coefficient and improve the quality of IVIM parameter maps. For all studied abdominal organs except the pancreas, both the proposed method and the BP method could provide IVIM parameter estimates close to the reference values; the former had higher precision. The kernelized total difference-based curve-fitting method has the potential to improve the reliability of IVIM parametric imaging.

2.
Cytometry A ; 103(4): 295-303, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36268593

RESUMO

Deep learning has been used to classify the while blood cells in peripheral blood smears. However, the classification of developing neutrophils is rarely studied. Moreover, it is still unknown whether deep learning can work well on the data coming from different sources. In this study, we therefore investigate the classification performance of deep learning for immature and mature neutrophils. In particular, we used three open-access datasets obtained from different imaging systems: CellaVision DM 96, CellaVision DM 100, and iCELL ME-150. A total of 26,050 images identified by one laboratory technologist were randomly split into training, validation, and testing datasets. A total of 10 convolutional neural networks were trained to classify six blood cell types: myeloblast, promyelocyte, myelocyte, metamyelocyte, banded neutrophil, and segmented neutrophil. The experimental results showed that compared to any single model, the average ensemble model could achieve a better classification performance and provide a testing accuracy of 90.1%. The sensitivity and specificity of the average ensemble model for the six blood cell types were above 83.5% and 96.9%, respectively. Our results suggest that deep learning is a promising tool for the classification of developing neutrophils, but further improvement is required.


Assuntos
Aprendizado Profundo , Neutrófilos , Redes Neurais de Computação
3.
Opt Express ; 31(12): 19897-19908, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37381395

RESUMO

Quantitative differential phase contrast (QDPC) microscope plays an important role in biomedical research since it can provide high-resolution images and quantitative phase information for thin transparent objects without staining. With weak phase assumption, the retrieval of phase information in QDPC can be treated as a linearly inverse problem which can be solved by Tikhonov regularization. However, the weak phase assumption is limited to thin objects, and tuning the regularization parameter manually is inconvenient. A self-supervised learning method based on deep image prior (DIP) is proposed to retrieve phase information from intensity measurements. The DIP model that takes intensity measurements as input is trained to output phase image. To achieve this goal, a physical layer that synthesizes the intensity measurements from the predicted phase is used. By minimizing the difference between the measured and predicted intensities, the trained DIP model is expected to reconstruct the phase image from its intensity measurements. To evaluate the performance of the proposed method, we conducted two phantom studies and reconstructed the micro-lens array and standard phase targets with different phase values. In the experimental results, the deviation of the reconstructed phase values obtained from the proposed method was less than 10% of the theoretical values. Our results show the feasibility of the proposed methods to predict quantitative phase with high accuracy, and no use of ground truth phase.

4.
J Digit Imaging ; 35(4): 834-845, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35239090

RESUMO

Parametric imaging obtained from kinetic modeling analysis of dynamic positron emission tomography (PET) data is a useful tool for quantifying tracer kinetics. However, pixel-wise time-activity curves have high noise levels which lead to poor quality of parametric images. To solve this limitation, we proposed a new image denoising method based on deep image prior (DIP). Like the original DIP method, the proposed DIP method is an unsupervised method, in which no training dataset is required. However, the difference is that our method can simultaneously denoise all dynamic PET images. Moreover, we propose a modified version of the DIP method called double DIP (DDIP), which has two DIP architectures. The additional DIP model is used to generate high-quality input data for the second DIP model. Computer simulations were performed to evaluate the performance of the proposed DIP-based methods. Our simulation results showed that the DDIP method outperformed the single DIP method. In addition, the DDIP method combined with data augmentation could generate PET parametric images with superior image quality compared to the spatiotemporal-based non-local means filtering and high constrained backprojection. Our preliminary results show that our proposed DDIP method is a novel and effective unsupervised method for simultaneously denoising dynamic PET images.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Algoritmos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Cinética , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído
5.
J Digit Imaging ; 34(1): 149-161, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33432448

RESUMO

Deep learning (DL) has shown great potential in conversions between various imaging modalities. Similarly, DL can be applied to synthesize a high-kV computed tomography (CT) image from its corresponding low-kV CT image. This indicates the feasibility of obtaining dual-energy CT (DECT) images without purchasing a DECT scanner. In this study, we investigated whether a low-to-high kV mapping was better than a high-to-low kV mapping. We used a U-Net model to perform conversions between different kV CT images. Moreover, we proposed a double U-Net model to improve the quality of original single-energy CT images. Ninety-eight patients who underwent brain DECT scans were used to train, validate, and test the proposed DL-based model. The results showed that the low-to-high kV conversion was better than the high-to-low kV conversion. In addition, the DL-based DECT images had better signal-to-noise ratios (SNRs) than the true (original) DECT images, but at the expense of a slight loss in spatial resolution. The mean CT number differences between the true and DL-based DECT images were within [Formula: see text] 1 HU. No statistically significant difference in CT number measurements was found between the true and DL-based DECT images (p > 0.05). The DL-based DECT images with improved SNR could produce low-noise virtual monoenergetic images. Our preliminary results indicate that DL has the potential to generate brain DECT images using single-energy brain CT images.


Assuntos
Aprendizado Profundo , Encéfalo/diagnóstico por imagem , Cabeça , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
6.
NMR Biomed ; 33(4): e4249, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31922646

RESUMO

In this study, we evaluate whether diffusion-weighted magnetic resonance imaging (DW-MRI) data after denoising can provide a reliable estimation of brain intravoxel incoherent motion (IVIM) perfusion parameters. Brain DW-MRI was performed in five healthy volunteers on a 3 T clinical scanner with 12 different b-values ranging from 0 to 1000 s/mm2 . DW-MRI data denoised using the proposed method were fitted with a biexponential model to extract perfusion fraction (PF), diffusion coefficient (D) and pseudo-diffusion coefficient (D*). To further evaluate the accuracy and precision of parameter estimation, IVIM parametric images obtained from one volunteer were used to resimulate the DW-MRI data using the biexponential model with the same b-values. Rician noise was added to generate DW-MRI data with various signal-to-noise ratio (SNR) levels. The experimental results showed that the denoised DW-MRI data yielded precise estimates for all IVIM parameters. We also found that IVIM parameters were significantly different between gray matter and white matter (P < 0.05), except for D* (P = 0.6). Our simulation results show that the proposed image denoising method displays good performance in estimating IVIM parameters (both bias and coefficient of variation were <12% for PF, D and D*) in the presence of different levels of simulated Rician noise (SNRb=0 = 20-40). Simulations and experiments show that brain DW-MRI data after denoising can provide a reliable estimation of IVIM parameters.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Movimento (Física) , Mapeamento Encefálico , Simulação por Computador , Humanos
7.
J Appl Clin Med Phys ; 20(9): 104-113, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31390137

RESUMO

PURPOSE: Virtual monoenergetic images (VMIs) derived from dual-energy computed tomography (DECT) have been explored for several clinical applications in recent years. However, VMIs at low and high keVs have high levels of noise. The aim of this study was to reduce image noise in VMIs by using a two-step noise reduction technique. METHODS: VMI was first denoised using a modified highly constrained backprojection (HYPR) method. After the first-step denoising, a general-threshold filtering method was performed. Two sets of anthropomorphic phantoms were scanned with a clinical dual-source DECT system. DECT data (80/140Sn kV) were reconstructed as VMI series at 12 different energy levels (range, 40-150 keV, interval, 10 keV). For comparison, the averaged VMIs obtained from 10 repeated DECT scans were used as the reference standard. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and root-mean-square error (RMSE) were used to evaluate the quality of VMIs. RESULTS: Compared to the original HYPR method, the proposed two-step image denoising method could provide better performance in terms of SNR, CNR, and RMSE. In addition, the proposed method could achieve effective noise reduction while preserving edges and small structures, especially for low-keV VMIs. CONCLUSION: The proposed two-step image denoising method is a feasible method for reducing noise in VMIs obtained from a clinical DECT scanner. The proposed method can also reduce edge blurring and the loss of intensity in small lesions.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Humanos
8.
Magn Reson Med ; 78(4): 1383-1391, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27797155

RESUMO

PURPOSE: Total variation (TV) method has been used widely for image restoration and reconstruction. In this work, we propose a TV-based algorithm for parametric image generation in intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: We used simulated and real data to investigate whether the proposed TV-based method can provide reliable parametric images. Parametric images of IVIM parameters including perfusion fraction (PF), diffusion coefficient (D), and pseudo-diffusion coefficient (D*) were estimated using DW-MRI data and TV through fitting the IVIM model. The Levenberg-Marquardt (LM) method, which has often been used in the context of IVIM analysis, was employed as the standard method for comparison of the resulting parametric images. RESULTS: The simulation results show that the proposed method outperforms the LM algorithm in terms of precision, providing a 40-81%, 90-93%, and 68-84% improvement for PF, D and D*, respectively, at signal-to-noise ratio (SNR) of 30. For real data, the proposed method showed an average five-fold, three-fold, and four-fold improvement in the SNR for PF, D and D*, respectively. CONCLUSION: We introduced the use of TV to produce parametric images, and demonstrated that the proposed TV-based method is effective in improving the parametric image quality. Magn Reson Med 78:1383-1391, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Feminino , Humanos , Pessoa de Meia-Idade , Razão Sinal-Ruído
9.
J Appl Clin Med Phys ; 16(5): 418­426, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699312

RESUMO

The objective of this study was to evaluate the accuracy of dual-energy CT (DECT) for quantifying iodine using a soft tissue-mimicking phantom across various DECT acquisition parameters and dual-source CT (DSCT) scanners. A phantom was constructed with plastic tubes containing soft tissue-mimicking materials with known iodine concentrations (0-20 mg/mL). Experiments were performed on two DSCT scanners, one equipped with an integrated detector and the other with a conventional detector. DECT data were acquired using two DE modes (80 kV/Sn140 kV and 100 kV/Sn140 kV) with four pitch values (0.6, 0.8, 1.0, and 1.2). Images were reconstructed using a soft tissue kernel with and without beam hardening correction (BHC) for iodine. Using the dedicated DE software, iodine concentrations were measured and compared to true concentrations. We also investigated the effect of reducing gantry rotation time on the DECT-based iodine measurement. At iodine concentrations higher than 10 mg/mL, the relative error in measured iodine concentration increased slightly. This error can be decreased by using the kernel with BHC, compared with the kernel without BHC. Both 80 kV/Sn140 kV and 100 kV/Sn140 kV modes could provide accurate quantification of iodine content. Increasing pitch value or reducing gantry rotation time had only a minor impact on the DECT-based iodine measurement. The DSCT scanner, equipped with the new integrated detector, showed more accurate iodine quantification for all iodine concentrations higher than 10 mg/mL. An accurate quantification of iodine can be obtained using the second-generation DSCT scanner in various DE modes with pitch values up to 1.2 and gantry rotation time down to 0.28 s. For iodine concentrations ≥ 10 mg/mL, using the new integrated detector and the kernel with BHC can improve the accuracy of DECT-based iodine measurements.


Assuntos
Iodo/farmacocinética , Fígado/metabolismo , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomógrafos Computadorizados , Humanos , Software , Distribuição Tecidual , Tomografia Computadorizada por Raios X
10.
Phys Eng Sci Med ; 46(4): 1607-1617, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695508

RESUMO

Material decomposition (MD) is an application of dual-energy computed tomography (DECT) that decomposes DECT images into specific material images. However, the direct inversion method used in MD often amplifies noise in the decomposed material images, resulting in lower image quality. To address this issue, we propose an image-domain MD method based on the concept of deep image prior (DIP). DIP is an unsupervised learning method that can perform different tasks without using a large training dataset with known targets (i.e., basis material images). We retrospectively recruited patients who underwent non-contrast brain DECT scans and investigated the feasibility of using the proposed DIP-based method to decompose DECT images into two (i.e., bone and soft tissue) and three (i.e., bone, soft tissue, and fat) basis materials. We evaluated the decomposed material images in terms of signal-to-noise ratio (SNR) and modulation transfer function (MTF). The proposed DIP-based method showed greater improvement in SNR in the decomposed soft-tissue images compared to the direct inversion method and the iterative method. Moreover, the proposed method produced similar MTF curves in both two- and three-material decompositions. Additionally, the proposed DIP-based method demonstrated better separation ability than the other two studied methods in the case of three-material decomposition. Our results suggest that the proposed DIP-based method is capable of unsupervisedly generating high-quality basis material images from DECT images.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Aprendizado de Máquina não Supervisionado , Imagens de Fantasmas
11.
Biomed Opt Express ; 14(7): 3458-3468, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37497508

RESUMO

Quantitative differential phase-contrast (DPC) imaging is one of the commonly used methods for phase retrieval. However, quantitative DPC imaging requires several pairwise intensity measurements, which makes it difficult to monitor living cells in real-time. In this study, we present a single-shot quantitative DPC imaging method based on the combination of deep learning (DL) and color-encoded illumination. Our goal is to train a model that can generate an isotropic quantitative phase image (i.e., target) directly from a single-shot intensity measurement (i.e., input). The target phase image was reconstructed using a linear-gradient pupil with two-axis measurements, and the model input was the measured color intensities obtained from a radially asymmetric color-encoded illumination pattern. The DL-based model was trained, validated, and tested using thirteen different cell lines. The total number of training, validation, and testing images was 264 (10 cells), 10 (1 cell), and 40 (2 cells), respectively. Our results show that the DL-based phase images are visually similar to the ground-truth phase images and have a high structural similarity index (>0.98). Moreover, the phase difference between the ground-truth and DL-based phase images was smaller than 13%. Our study shows the feasibility of using DL to generate quantitative phase imaging from a single-shot intensity measurement.

12.
Phys Med Biol ; 67(21)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36228623

RESUMO

Objective.Intravoxel incoherent motion (IVIM) imaging obtained by fitting a biexponential model to multipleb-value diffusion-weighted magnetic resonance imaging (DW-MRI) has been shown to be a promising tool for different clinical applications. Recently, several deep neural network (DNN) methods were proposed to generate IVIM imaging.Approach.In this study, we proposed an unsupervised convolutional neural network (CNN) method for estimation of IVIM parameters. We used both simulated and real abdominal DW-MRI data to evaluate the performance of the proposed CNN-based method, and compared the results with those obtained from a non-linear least-squares fit (TRR, trust-region reflective algorithm) and a feed-forward backward-propagation DNN-based method.Main results.The simulation results showed that both the DNN- and CNN-based methods had lower coefficients of variation than the TRR method, but the CNN-based method provided more accurate parameter estimates. The results obtained from real DW-MRI data showed that the TRR method produced many biased IVIM parameter estimates that hit the upper and lower parameter bounds. In contrast, both the DNN- and CNN-based methods yielded less biased IVIM parameter estimates. Overall, the perfusion fraction and diffusion coefficient obtained from the DNN- and CNN-based methods were close to literature values. However, compared with the CNN-based method, both the TRR and DNN-based methods tended to yield increased pseudodiffusion coefficients (55%-180%).Significance.Our preliminary results suggest that it is feasible to estimate IVIM parameters using CNN.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos , Movimento (Física) , Análise dos Mínimos Quadrados , Redes Neurais de Computação , Reprodutibilidade dos Testes
13.
Med Phys ; 38(8): 4587-99, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21928632

RESUMO

PURPOSE: A new model is introduced that individually resolves the delivery, transport, and phosphorylation steps of metabolism of glucose and its analogs in skeletal muscle by interpreting dynamic positron emission tomography (PET) data. METHODS: The model uniquely utilizes information obtained from the competition between glucose and its radiolabeled analogs. Importantly, the model avoids use of a lumped constant which may depend on physiological state. Four basic physiologic quantities constitute our model parameters, including the fraction of total tissue space occupied by interstitial space (f(IS)), a flow-extraction product and interstitial (IS(g)) and intracellular (IC(g)) glucose concentrations. Using the values of these parameters, cellular influx (CI) and efflux (CE) of glucose, glucose phosphorylation rate (PR), and maximal transport (V(G)) and phosphorylation capacities (V(H)) can all be determined. Herein, the theoretical derivation of our model is addressed and characterizes its properties via simulation. Specifically, the model performance is evaluated by simulation of basal and euglycemic hyperinsulinemic (EH) conditions. RESULTS: In fitting the model-generated, synthetic data (including noise), mean estimates of all but IC(g) of the parameter values are within 5% of their values for both conditions. In addition, mean errors of CI, PR, and V(G) are less than 5% whereas those of VH and CE are not. CONCLUSIONS: It is concluded that under the conditions tested, the novel model can provide accurate parameter estimates and physiological quantities, except IC(g) and two quantities that are dependent on IC(g), namely CE and VH. However, the ability to estimate IC(g) seems to improve with increases in intracellular glucose concentrations as evidenced by comparing IC(g) estimates under basal vs EH conditions.


Assuntos
Glucose/metabolismo , Modelos Biológicos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/metabolismo , Animais , Transporte Biológico Ativo , Glicemia/metabolismo , Fluordesoxiglucose F18/farmacocinética , Glucose/análogos & derivados , Técnica Clamp de Glucose , Hiperinsulinismo/metabolismo , Fosforilação , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Ratos
14.
Med Phys ; 48(9): 5300-5310, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34260083

RESUMO

PURPOSE: Due to the lack of depth-of-interaction information, a Compton camera made of lutetium-yttrium orthosilicate (LYSO) crystals suffers from poor spatial resolution, which may lead to an unreliable range verification in proton therapy. The aim of this study is to evaluate the performance of a LYSO-based Compton camera using the origin ensemble algorithm with resolution recovery (OE-RR). We also proposed a regularized version of OE-RR called ROE-RR. METHODS: We simulated a two-layer LYSO-based Compton camera which was used to detect prompt gammas (PGs) produced by a proton beam irradiated on a water phantom. PG images reconstructed by the OE-RR algorithm were evaluated and compared with those reconstructed by the proposed ROE-RR algorithm. RESULTS: Our simulated results show that both the OE-RR and ROE-RR algorithms could provide an accurate estimate of the Bragg peak position, with a mean positioning error of 2.5 mm. Compared to the OE-RR algorithm, the proposed ROE-RR algorithm is less sensitive with respect to initial conditions and requires less iterations for converging to equilibrium. More importantly, the proposed ROE-RR algorithm could provide better image quality than the OE-RR algorithm, especially in low-count data. CONCLUSIONS: For LYSO-based Compton cameras, using a resolution-recovery image reconstruction algorithm is essential for reliable range verification.


Assuntos
Lutécio , Ítrio , Algoritmos , Processamento de Imagem Assistida por Computador , Método de Monte Carlo , Imagens de Fantasmas
15.
IEEE Trans Med Imaging ; 40(11): 3229-3237, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34152982

RESUMO

Quantitative differential phase-contrast (qDPC) imaging is a label-free phase retrieval method for weak phase objects using asymmetric illumination. However, qDPC imaging with fewer intensity measurements leads to anisotropic phase distribution in reconstructed images. In order to obtain isotropic phase transfer function, multiple measurements are required; thus, it is a time-consuming process. Here, we propose the feasibility of using deep learning (DL) method for isotropic qDPC microscopy from the least number of measurements. We utilize a commonly used convolutional neural network namely U-net architecture, trained to generate 12-axis isotropic reconstructed cell images (i.e. output) from 1-axis anisotropic cell images (i.e. input). To further extend the number of images for training, the U-net model is trained with a patch-wise approach. In this work, seven different types of living cell images were used for training, validation, and testing datasets. The results obtained from testing datasets show that our proposed DL-based method generates 1-axis qDPC images of similar accuracy to 12-axis measurements. The quantitative phase value in the region of interest is recovered from 66% up to 97%, compared to ground-truth values, providing solid evidence for improved phase uniformity, as well as retrieved missing spatial frequencies in 1-axis reconstructed images. In addition, results from our model are compared with paired and unpaired CycleGANs. Higher PSNR and SSIM values show the advantage of using the U-net model for isotropic qDPC microscopy. The proposed DL-based method may help in performing high-resolution quantitative studies for cell biology.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Microscopia de Contraste de Fase
16.
Am J Physiol Heart Circ Physiol ; 299(6): H1917-27, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20852054

RESUMO

Previous studies have reported that high fat feeding in mild to moderate heart failure (HF) results in the preservation of contractile function. Recent evidence has suggested that preventing the switch from fatty acid to glucose metabolism in HF may ameliorate dysfunction, and insulin resistance is one potential mechanism for regulating substrate utilization. This study was designed to determine whether peripheral and myocardial insulin resistance exists with HF and/or a high-fat diet and whether myocardial insulin signaling was altered accordingly. Rats underwent coronary artery ligation (HF) or sham surgery and were randomized to normal chow (NC; 14% kcal from fat) or a high-fat diet (SAT; 60% kcal from fat) for 8 wk. HF + SAT animals showed preserved systolic (+dP/dt and stroke work) and diastolic (-dP/dt and time constant of relaxation) function compared with HF + NC animals. Glucose tolerance tests revealed peripheral insulin resistance in sham + SAT, HF + NC, and HF + SAT animals compared with sham + NC animals. PET imaging confirmed myocardial insulin resistance only in HF + SAT animals, with an uptake ratio of 2.3 ± 0.3 versus 4.6 ± 0.7, 4.3 ± 0.4, and 4.2 ± 0.6 in sham + NC, sham + SAT, and HF + NC animals, respectively; the myocardial glucose utilization rate was similarly decreased in HF + SAT animals only. Western blot analysis of insulin signaling protein expression was indicative of cardiac insulin resistance in HF + SAT animals. Specifically, alterations in Akt and glycogen synthase kinase-3ß protein expression in HF + SAT animals compared with HF + NC animals may be involved in mediating myocardial insulin resistance. In conclusion, HF animals fed a high-saturated fat exhibited preserved myocardial contractile function, peripheral and myocardial insulin resistance, decreased myocardial glucose utilization rates, and alterations in cardiac insulin signaling. These results suggest that myocardial insulin resistance may serve a cardioprotective function with high fat feeding in mild to moderate HF.


Assuntos
Gorduras na Dieta/metabolismo , Metabolismo Energético , Insuficiência Cardíaca/fisiopatologia , Resistência à Insulina , Insulina/metabolismo , Contração Miocárdica , Miocárdio/metabolismo , Função Ventricular Esquerda , Animais , Glicemia/metabolismo , Western Blotting , Gorduras na Dieta/administração & dosagem , Gorduras na Dieta/sangue , Modelos Animais de Doenças , Ecocardiografia Doppler , Teste de Tolerância a Glucose , Quinase 3 da Glicogênio Sintase/metabolismo , Glicogênio Sintase Quinase 3 beta , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/metabolismo , Masculino , Fosforilação , Tomografia por Emissão de Pósitrons , Proteínas Proto-Oncogênicas c-akt/metabolismo , Ratos , Ratos Wistar , Transdução de Sinais , Fatores de Tempo , Pressão Ventricular
17.
J Fluoresc ; 20(5): 1087-98, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20405175

RESUMO

Molecular rotors are a group of fluorescent molecules that form twisted intramolecular charge transfer states (TICT) upon photoexcitation. Some classes of molecular rotors, among them those that are built on the benzylidene malononitrile motif, return to the ground state either by nonradiative intramolecular rotation or by fluorescence emission. In low-viscosity solvents, intramolecular rotation dominates, and the fluorescence quantum yield is low. Higher solvent viscosities reduce the intramolecular rotation rate, thus increasing the quantum yield. We recently described a different mechanism whereby the fluorescence quantum yield of the molecular rotor also depends on the shear stress of the solvent. In this study, we examined a possible application for shear-sensitive molecular rotors for imaging flow patterns in fluidic chambers. Flow chambers with different geometries were constructed from polycarbonate or acrylic. Solutions of molecular rotors in ethylene glycol were injected into the chamber under controlled flow rates. LED-induced fluorescence (LIF) images of the flow chambers were taken with a digital camera, and the intensity difference between flow and no-flow images was visualized and compared to computed fluid dynamics (CFD) simulations. Intensity differences were detectable with average flow rates as low as 0.1 mm/s, and an exponential association between flow rate and intensity increase was found. Furthermore, a good qualitative match to computed fluid dynamics simulations was seen. On the other hand, prolonged exposure to light reduced the emission intensity. With its high sensitivity and high spatial and temporal resolution, imaging of flow patterns with molecular rotors may become a useful tool in microfluidics, flow measurement, and control.


Assuntos
Corantes/química , Corantes Fluorescentes/química , Hidrodinâmica , Processamento de Imagem Assistida por Computador , Sondas Moleculares/química , Simulação por Computador , Fluorescência , Microfluídica/instrumentação , Sondas Moleculares/análise , Estrutura Molecular , Solventes/química , Espectrometria de Fluorescência , Viscosidade
18.
Nano Lett ; 9(5): 1839-43, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19338282

RESUMO

A new and general approach to achieving efficient electrically driven light emission from a Si-based nano p-n junction array is introduced. A wafer-scale array of p-type silicon nanotips were formed by a single-step self-masked dry etching process, which is compatible with current semiconductor technologies. On top of the silicon nanotip array, a layer of n-type ZnO film was grown by pulsed laser deposition. Both the narrow line width of 10 nm in cathodoluminescence spectra and the appearance of multiphonon Raman spectra up to the fourth order indicate the excellent quality of the ZnO film. The turn-on voltage of our ZnO/Si nanotip array is found to be approximately 2.4 V, which is 2 times smaller than its thin film counterpart. Moreover, electroluminescence (EL) from our ZnO/Si nanotips array light-emitting diode (LED) has been demonstrated. Our results could open up new possibilities to integrate silicon-based optoelectronic devices, such as highly efficient LEDs, with standard Si ultralarge-scale integrated technology.

19.
Phys Med Biol ; 65(22): 225006, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33200750

RESUMO

Due to high levels of noise in pixel-wise time-activity curves, the indirect method that generates kinetic parametric images from dynamic positron emission tomography (PET) images often results in poor parametric image quality. We have demonstrated that the quality of parametric images can be improved by denoising dynamic PET images, using gradient-free curve-fitting and applying a kernel-based post-filtering to parametric images. However, many gradient-free curve-fitting methods are time-consuming. Moreover, some parameter estimates (e.g. k2 and k3) have large variability. To provide high-quality PET parametric images with low computational cost, we propose a curve-fitting method that incorporates the kernel-based denoising method and the highly constrained backprojection technique into the Levenberg-Marquardt (LM) algorithm. We conducted a simulation study to evaluate the performance of the proposed curve-fitting method. Dynamic PET images were reconstructed using the expectation-maximization (EM) algorithm and were denoised before parameter estimation. Compared to the LM algorithm with and without the kernel-based post-filtering, the proposed method achieved superior performance, offering a decrease in both bias and coefficient of variation (CV) on all parametric images. Overall, the proposed method exhibited lower bias and slightly higher CV than the gradient-free pattern search method with the kernel-based post-filtering (PatS-K). Moreover, the computation time of the proposed method was about 18 times lower than that of the PatS-K method. Finally, we show that the proposed method can further improve the quality of parametric images when dynamic PET images are reconstructed using the kernel-based EM algorithm.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons , Algoritmos , Simulação por Computador , Humanos , Cinética
20.
Phys Med Biol ; 65(10): 105003, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-32187580

RESUMO

The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image prior (DIP). In this method, high-quality prior images obtained from the same patient were used as the network input, and all noisy DW images were used as the network output. Our aim is to denoise all b-value DW images simultaneously. By using early stopping, we expect the DIP-based model to learn the content of images instead of the noise. The performance of the proposed DIP method was evaluated using both simulated and real DW-MRI data. We simulated a digital phantom and generated noise-free DW-MRI data according to the intravoxel incoherent motion model. Different levels of Rician noise were then simulated. The proposed DIP method was compared with the image denoising method using local principal component analysis (LPCA). The simulation results show that the proposed DIP method outperforms the LPCA method in terms of mean-squared error and parameter estimation. The results of real DW-MRI data show that the proposed DIP method can improve the quality of IVIM parametric images. DIP is a feasible method for denoising multiple b-value DW-MRI data.


Assuntos
Aprendizado Profundo , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído , Algoritmos , Humanos , Imagens de Fantasmas , Análise de Componente Principal , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA