Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Int J Cancer ; 149(2): 431-441, 2021 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-33811763

RESUMO

We conducted a prospective evaluation of the diagnostic performance of high-resolution microendoscopy (HRME) to detect cervical intraepithelial neoplasia (CIN) in women with abnormal screening tests. Study participants underwent colposcopy, HRME and cervical biopsy. The prospective diagnostic performance of HRME using an automated morphologic image analysis algorithm was compared to that of colposcopy using histopathologic detection of CIN as the gold standard. To assess the potential to further improve performance of HRME image analysis, we also conducted a retrospective analysis assessing performance of a multi-task convolutional neural network to segment and classify HRME images. One thousand four hundred eighty-six subjects completed the study; 435 (29%) subjects had CIN Grade 2 or more severe (CIN2+) diagnosis. HRME with morphologic image analysis for detection of CIN Grade 3 or more severe diagnoses (CIN3+) was similarly sensitive (95.6% vs 96.2%, P = .81) and specific (56.6% vs 58.7%, P = .18) as colposcopy. HRME with morphologic image analysis for detection of CIN2+ was slightly less sensitive (91.7% vs 95.6%, P < .01) and specific (59.7% vs 63.4%, P = .02) than colposcopy. Images from 870 subjects were used to train a multi-task convolutional neural network-based algorithm and images from the remaining 616 were used to validate its performance. There were no significant differences in the sensitivity and specificity of HRME with neural network analysis vs colposcopy for detection of CIN2+ or CIN3+. Using a neural network-based algorithm, HRME has comparable sensitivity and specificity to colposcopy for detection of CIN2+. HRME could provide a low-cost, point-of-care alternative to colposcopy and biopsy in the prevention of cervical cancer.


Assuntos
Histeroscopia/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Displasia do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Brasil , Colposcopia , Sistemas Computacionais , Feminino , Humanos , Microtecnologia , Pessoa de Meia-Idade , Redes Neurais de Computação , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
2.
Lasers Surg Med ; 53(6): 748-775, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34015146

RESUMO

This article reviews deep learning applications in biomedical optics with a particular emphasis on image formation. The review is organized by imaging domains within biomedical optics and includes microscopy, fluorescence lifetime imaging, in vivo microscopy, widefield endoscopy, optical coherence tomography, photoacoustic imaging, diffuse tomography, and functional optical brain imaging. For each of these domains, we summarize how deep learning has been applied and highlight methods by which deep learning can enable new capabilities for optics in medicine. Challenges and opportunities to improve translation and adoption of deep learning in biomedical optics are also summarized. Lasers Surg. Med. © 2021 Wiley Periodicals LLC.


Assuntos
Aprendizado Profundo , Microscopia , Imagem Óptica , Óptica e Fotônica , Tomografia de Coerência Óptica
3.
Biophys J ; 112(1): 121-132, 2017 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-28076803

RESUMO

Although the effects of ethanol on protein receptors and lipid membranes have been studied extensively, ethanol's effect on vesicles fusing to lipid bilayers is not known. To determine the effect of alcohols on fusion rates, we utilized the nystatin/ergosterol fusion assay to measure fusion of liposomes to a planar lipid bilayer (BLM). The addition of ethanol excited fusion when applied on the cis (vesicle) side, and inhibited fusion on the trans side. Other short-chain alcohols followed a similar pattern. In general, the inhibitory effect of alcohols (trans) occurs at lower doses than the excitatory (cis) effect, with a decrease of 29% in fusion rates at the legal driving limit of 0.08% (w/v) ethanol (IC50 = 0.2% v/v, 34 mM). Similar inhibitory effects were observed with methanol, propanol, and butanol, with ethanol being the most potent. Significant variability was observed with different alcohols when applied to the cis side. Ethanol and propanol enhanced fusion, butanol also enhanced fusion but was less potent, and low doses of methanol mildly inhibited fusion. The inhibition by trans addition of alcohols implies that they alter the planar membrane structure and thereby increase the activation energy required for fusion, likely through an increase in membrane fluidity. The cis data are likely a combination of the above effect and a proportionally greater lowering of the vesicle lysis tension and hydration repulsive pressure that combine to enhance fusion. Alternate hypotheses are also discussed. The inhibitory effect of ethanol on liposome-membrane fusion is large enough to provide a possible biophysical explanation of compromised neuronal behavior.


Assuntos
Etanol/química , Etanol/farmacologia , Bicamadas Lipídicas/metabolismo , Lipossomos/metabolismo , Fusão de Membrana/efeitos dos fármacos , Relação Dose-Resposta a Droga , Exocitose/efeitos dos fármacos , Fluidez de Membrana/efeitos dos fármacos
4.
Adv Radiat Oncol ; 9(1): 101314, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38260228

RESUMO

Purpose: In our experience treating locally advanced pancreatic cancer with magnetic resonance-guided radiation therapy (MRgRT), the true-fast imaging with steady-state free precession sequences used to generate both the real-time 2-dimensional (2D) magnetic resonance images (MRI; 2D cine) and the pretreatment high-resolution 3-dimensional (3D) MRI impart differing intensities for relevant structures between the 2 scans. Since these variations can confound target tracking selection, we propose that an understanding of the differing contrast profiles could improve selection of tracking structures. Methods and Materials: We retrospectively reviewed both 2D cine and 3D MRI images for 20 patients with pancreatic cancer treated with MRgRT. At simulation, an appropriate tracking target was identified and contoured on a single 3-mm sagittal slice of the 3D MRI. This sagittal slice was directly compared with the coregistered 7-mm 2D cine to identify structures with notable discrepancies in signal intensity. The 3D MRI was then explored in additional planes to confirm structure identities. For quantitative verification of the clinically observed differences, the pixel intensity distributions of 2D cine and 3D MRI digital imaging and communications in medicine data sets were statistically compared. Results: In all patients reviewed, arteries (aorta, celiac, superior mesenteric artery, hepatic artery) appeared mildly hyperintense on both scans. However, veins (portal vein, superior mesenteric vein) appeared hyperintense on 2D cine but isointense on 3D MRI. Biliary structures appeared mildly hyperintense on 2D cine but starkly hyperintense on 3D MRI. The pixel intensity distributions extracted from 2D cine and 3D MRI images were confirmed to differ significantly (2 sample Kolmogorov-Smirnov test; test statistic, 0.40; P < .001). Conclusions: There are significant variations in image intensity between the immediate pretreatment 2D cine compared with the initial planning 3D MRI. Understanding variations of image intensity between the different MRI sequences used in MRgRT is valuable to radiation oncologists and may lead to improved target tracking and optimized treatment delivery.

5.
Int J Radiat Oncol Biol Phys ; 115(4): 983-993, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36309075

RESUMO

PURPOSE: We developed a deep learning (DL) model for fast deformable image registration using 2-dimensional sagittal cine magnetic resonance imaging (MRI) acquired during radiation therapy and evaluated its potential for real-time target tracking compared with conventional image registration methods. METHODS AND MATERIALS: Our DL model uses a pair of cine MRI images as input and provides a motion vector field (MVF) as output. The MVF is then applied to align the input images. A retrospective study was conducted to train and evaluate our model using cine MRI data from patients undergoing treatment for abdominal and thoracic tumors. For each treatment fraction, MR-linear accelerator delivery log files, tracking videos, and cine image files were analyzed. Individual MRI frames were temporally sampled to construct a large set of image registration pairs used to evaluate multiple methods. The DL model was optimized using 5-fold cross validation, and model outputs (transformed images and MVFs) using test set images were saved for comparison with 3 conventional registration methods (affine, b-spline, and demons). Evaluation metrics were 3-fold: (1) registration error, (2) MVF stability (both spatial and temporal), and (3) average computation time. RESULTS: We analyzed >21 hours of cine MRI (>629,000 frames) acquired during 86 treatment fractions from 21 patients. In a test set of 10,320 image registration pairs, DL registration outperformed conventional methods in both registration error (affine, b-spline, demons, DL; root mean square error: 0.067, 0.040, 0.036, 0.032; paired t test demons vs DL: t[20] = 4.2, P < .001) and computation time per frame (51, 1150, 4583, 8 ms). Among deformable methods, spatial stability of resulting MVFs was comparable; however, the DL model had significantly improved temporal consistency. CONCLUSIONS: DL-based image registration can leverage large-scale MR cine data sets to outperform conventional registration methods and is a promising solution for real-time deformable motion estimation in radiation therapy.


Assuntos
Aprendizado Profundo , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
6.
Front Med Technol ; 5: 1009638, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36875185

RESUMO

Background: Fluorescence molecular imaging using ABY-029, an epidermal growth factor receptor (EGFR)-targeted, synthetic Affibody peptide labeled with a near-infrared fluorophore, is under investigation for surgical guidance during head and neck squamous cell carcinoma (HNSCC) resection. However, tumor-to-normal tissue contrast is confounded by intrinsic physiological limitations of heterogeneous EGFR expression and non-specific agent uptake. Objective: In this preliminary study, radiomic analysis was applied to optical ABY-029 fluorescence image data for HNSCC tissue classification through an approach termed "optomics." Optomics was employed to improve tumor identification by leveraging textural pattern differences in EGFR expression conveyed by fluorescence. The study objective was to compare the performance of conventional fluorescence intensity thresholding and optomics for binary classification of malignant vs. non-malignant HNSCC tissues. Materials and Methods: Fluorescence image data collected through a Phase 0 clinical trial of ABY-029 involved a total of 20,073 sub-image patches (size of 1.8 × 1.8 mm2) extracted from 24 bread-loafed slices of HNSCC surgical resections originating from 12 patients who were stratified into three dose groups (30, 90, and 171 nanomoles). Each dose group was randomly partitioned on the specimen-level 75%/25% into training/testing sets, then all training and testing sets were aggregated. A total of 1,472 standardized radiomic features were extracted from each patch and evaluated by minimum redundancy maximum relevance feature selection, and 25 top-ranked features were used to train a support vector machine (SVM) classifier. Predictive performance of the SVM classifier was compared to fluorescence intensity thresholding for classifying testing set image patches with histologically confirmed malignancy status. Results: Optomics provided consistent improvement in prediction accuracy and false positive rate (FPR) and similar false negative rate (FNR) on all testing set slices, irrespective of dose, compared to fluorescence intensity thresholding (mean accuracies of 89% vs. 81%, P = 0.0072; mean FPRs of 12% vs. 21%, P = 0.0035; and mean FNRs of 13% vs. 17%, P = 0.35). Conclusions: Optomics outperformed conventional fluorescence intensity thresholding for tumor identification using sub-image patches as the unit of analysis. Optomics mitigate diagnostic uncertainties introduced through physiological variability, imaging agent dose, and inter-specimen biases of fluorescence molecular imaging by probing textural image information. This preliminary study provides a proof-of-concept that applying radiomics to fluorescence molecular imaging data offers a promising image analysis technique for cancer detection in fluorescence-guided surgery.

7.
Artigo em Inglês | MEDLINE | ID: mdl-35600140

RESUMO

Breast-conserving surgery requires that resection margins be cancer-free, but re-excision rates due to positive margins have remained near 20% for much of the last decade with high variability between surgical centers. Recent studies have demonstrated that volumetric X-ray imaging improves margin assessment over standard techniques, given the speed of image reconstruction and full three-dimensional sensing of all margins. Deep learning approaches for automated analysis of volumetric medical image data are gaining traction and could play an important role streamlining the clinical workflow for intra-surgical specimen imaging. X-ray imaging systems currently deployed in clinical studies suffer from poor tumor-to-fibroglandular tissue contrast, motivating the development of adjuvant tools that could potentially complement volumetric X-ray scanning and further improve the future of intra-surgical margin assessment by real-time augmented guidance for the surgeon.

8.
Comput Med Imaging Graph ; 97: 102052, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35299096

RESUMO

Cervical cancer is a public health emergency in low- and middle-income countries where resource limitations hamper standard-of-care prevention strategies. The high-resolution endomicroscope (HRME) is a low-cost, point-of-care device with which care providers can image the nuclear morphology of cervical lesions. Here, we propose a deep learning framework to diagnose cervical intraepithelial neoplasia grade 2 or more severe from HRME images. The proposed multi-task convolutional neural network uses nuclear segmentation to learn a diagnostically relevant representation. Nuclear segmentation was trained via proxy labels to circumvent the need for expensive, manually annotated nuclear masks. A dataset of images from over 1600 patients was used to train, validate, and test our algorithm; data from 20% of patients were reserved for testing. An external evaluation set with images from 508 patients was used to further validate our findings. The proposed method consistently outperformed other state-of-the art architectures achieving a test per patient area under the receiver operating characteristic curve (AUC-ROC) of 0.87. Performance was comparable to expert colposcopy with a test sensitivity and specificity of 0.94 (p = 0.3) and 0.58 (p = 1.0), respectively. Patients with recurrent human papillomavirus (HPV) infections are at a higher risk of developing cervical cancer. Thus, we sought to incorporate HPV DNA test results as a feature to inform prediction. We found that incorporating patient HPV status improved test specificity to 0.71 at a sensitivity of 0.94.


Assuntos
Infecções por Papillomavirus , Displasia do Colo do Útero , Neoplasias do Colo do Útero , Colposcopia/métodos , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Redes Neurais de Computação , Infecções por Papillomavirus/diagnóstico por imagem , Gravidez , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Displasia do Colo do Útero/diagnóstico por imagem , Displasia do Colo do Útero/patologia
9.
J Biomed Opt ; 26(4)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33860648

RESUMO

SIGNIFICANCE: Smartphones come with an enormous array of functionality and are being more widely utilized with specialized attachments in a range of healthcare applications. A review of key developments and uses, with an assessment of strengths/limitations in various clinical workflows, was completed. AIM: Our review studies how smartphone-based imaging (SBI) systems are designed and tested for specialized applications in medicine and healthcare. An evaluation of current research studies is used to provide guidelines for improving the impact of these research advances. APPROACH: First, the established and emerging smartphone capabilities that can be leveraged for biomedical imaging are detailed. Then, methods and materials for fabrication of optical, mechanical, and electrical interface components are summarized. Recent systems were categorized into four groups based on their intended application and clinical workflow: ex vivo diagnostic, in vivo diagnostic, monitoring, and treatment guidance. Lastly, strengths and limitations of current SBI systems within these various applications are discussed. RESULTS: The native smartphone capabilities for biomedical imaging applications include cameras, touchscreens, networking, computation, 3D sensing, audio, and motion, in addition to commercial wearable peripheral devices. Through user-centered design of custom hardware and software interfaces, these capabilities have the potential to enable portable, easy-to-use, point-of-care biomedical imaging systems. However, due to barriers in programming of custom software and on-board image analysis pipelines, many research prototypes fail to achieve a prospective clinical evaluation as intended. Effective clinical use cases appear to be those in which handheld, noninvasive image guidance is needed and accommodated by the clinical workflow. Handheld systems for in vivo, multispectral, and quantitative fluorescence imaging are a promising development for diagnostic and treatment guidance applications. CONCLUSIONS: A holistic assessment of SBI systems must include interpretation of their value for intended clinical settings and how their implementations enable better workflow. A set of six guidelines are proposed to evaluate appropriateness of smartphone utilization in terms of clinical context, completeness, compactness, connectivity, cost, and claims. Ongoing work should prioritize realistic clinical assessments with quantitative and qualitative comparison to non-smartphone systems to clearly demonstrate the value of smartphone-based systems. Improved hardware design to accommodate the rapidly changing smartphone ecosystem, creation of open-source image acquisition and analysis pipelines, and adoption of robust calibration techniques to address phone-to-phone variability are three high priority areas to move SBI research forward.


Assuntos
Aplicativos Móveis , Smartphone , Ecossistema , Processamento de Imagem Assistida por Computador , Estudos Prospectivos , Software
10.
Biomed Opt Express ; 12(11): 6995-7008, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34858694

RESUMO

Smartphone-based fluorescence imaging systems have the potential to provide convenient quantitative image guidance at the point of care. However, common approaches have required the addition of complex optical attachments, which reduce translation potential. In this study, a simple clip-on attachment appropriate for fluorescence imaging of protoporphyrin-IX (PpIX) in skin was designed using the built-in light source and ultrawide camera sensor of a smartphone. Software control for image acquisition and quantitative analysis was developed using the 10-bit video capability of the phone. Optical performance was characterized using PpIX in liquid tissue phantoms and endogenously produced PpIX in mice and human skin. The proposed system achieves a very compact form factor (<30 cm3) and can be readily fabricated using widely available low-cost materials. The limit of detection of PpIX in optical phantoms was <10 nM, with good signal linearity from 10 to 1000 nM (R2 >0.99). Both murine and human skin imaging verified that in vivo PpIX fluorescence was detected within 1 hour of applying aminolevulinic acid (ALA) gel. This ultracompact handheld system for quantification of PpIX in skin is well-suited for dermatology clinical workflows. Due to its simplicity and form factor, the proposed system can be readily adapted for use with other smartphone devices and fluorescence imaging applications. Hardware design and software for the system is made freely available on GitHub (https://github.com/optmed/CompactFluorescenceCam).

11.
Sci Rep ; 11(1): 21832, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34750471

RESUMO

High positive margin rates in oncologic breast-conserving surgery are a pressing clinical problem. Volumetric X-ray scanning is emerging as a powerful ex vivo specimen imaging technique for analyzing resection margins, but X-rays lack contrast between non-malignant and malignant fibrous tissues. In this study, combined micro-CT and wide-field optical image radiomics were developed to classify malignancy of breast cancer tissues, demonstrating that X-ray/optical radiomics improve malignancy classification. Ninety-two standardized features were extracted from co-registered micro-CT and optical spatial frequency domain imaging samples extracted from 54 breast tumors exhibiting seven tissue subtypes confirmed by microscopic histological analysis. Multimodal feature sets improved classification performance versus micro-CT alone when adipose samples were included (AUC = 0.88 vs. 0.90; p-value = 3.65e-11) and excluded, focusing the classification task on exclusively non-malignant fibrous versus malignant tissues (AUC = 0.78 vs. 0.85; p-value = 9.33e-14). Extending the radiomics approach to high-dimensional optical data-termed "optomics" in this study-offers a promising optical image analysis technique for cancer detection. Radiomic feature data and classification source code are publicly available.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Imagem Óptica/métodos , Microtomografia por Raio-X/métodos , Tecido Adiposo/diagnóstico por imagem , Neoplasias da Mama/classificação , Feminino , Humanos , Técnicas In Vitro , Margens de Excisão , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Imagem Multimodal/estatística & dados numéricos , Imagem Óptica/instrumentação , Imagem Óptica/estatística & dados numéricos , Fenômenos Ópticos , Processos Estocásticos , Microtomografia por Raio-X/instrumentação , Microtomografia por Raio-X/estatística & dados numéricos
12.
Phys Med Biol ; 66(17)2021 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-34261044

RESUMO

Photodynamic therapy (PDT) offers localized focal ablation in unresectable pancreatic tumors while tissues surrounding the treatment volume experience a lower light dose, termed photodynamic priming (PDP). While PDP does not cause tissue damage, it has been demonstrated to promote vascular permeability, improve drug delivery, alleviate tumor cell density, and reduce desmoplasia and the resultant internal pressure in pre-clinical evaluation. Preclinical data supports PDP as a neoadjuvant therapy beneficial to subsequent chemotherapy or immunotherapy, yet it is challenging to quantify PDP effects in clinical treatment without additional imaging and testing. This study investigated the potential of radiomic analysis using CT scans acquired before and after PDT to identify areas experiencing PDT-induced necrosis as well as quantify PDP effects in the surrounding tissues. A total of 235 CT tumor slices from seven patients undergoing PDT for pancreatic tumors were examined. Radiomic features assessed included intensity metrics (CT number in Hounsfield Units) and texture analysis using several gray-level co-occurrence matrix (GLCM) parameters. Pre-treatment scans of tumor areas that resulted in PDT-induced necrosis showed statistically significant differences in intensity and texture-based features that could be used to predict the regions that did respond (paired t-test, response versus no response,p < 0.001). Evaluation of PDP effects on the surrounding tissues also demonstrated statistically significant differences, in tumor mean value, standard deviation, and GLCM parameters of contrast, dissimilarity and homogeneity (t-test, pre versus post,p < 0.001). Using leave-one-out cross validation, six intensity and texture-based features were combined into a support-vector machine model which demonstrated reliable prediction of treatment effects for six out of seven patients (ROC curve, AUC = 0.93). This study provides pilot evidence that texture features extracted from CT scans could be utilized as an effective clinical diagnostic prediction and assessment of PDT and PDP effects in pancreatic tumors. (clinical trial NCT03033225).


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/tratamento farmacológico , Humanos , Terapia Neoadjuvante , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/tratamento farmacológico , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Biomed Opt Express ; 12(5): 2800-2812, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34123505

RESUMO

High-resolution microendoscopy (HRME) is a low-cost strategy to acquire images of intact tissue with subcellular resolution at frame rates ranging from 11 to 18 fps. Current HRME imaging strategies are limited by the small microendoscope field of view (∼0.5 mm2); multiple images must be acquired and reliably registered to assess large regions of clinical interest. Image mosaics have been assembled from co-registered frames of video acquired as a microendoscope is slowly moved across the tissue surface, but the slow frame rate of previous HRME systems made this approach impractical for acquiring quality mosaicked images from large regions of interest. Here, we present a novel video mosaicking microendoscope incorporating a high frame rate CMOS sensor and optical probe holder to enable high-speed, high quality interrogation of large tissue regions of interest. Microendoscopy videos acquired at >90 fps are assembled into an image mosaic. We assessed registration accuracy and image sharpness across the mosaic for images acquired with a handheld probe over a range of translational speeds. This high frame rate video mosaicking microendoscope enables in vivo probe translation at >15 millimeters per second while preserving high image quality and accurate mosaicking, increasing the size of the region of interest that can be interrogated at high resolution from 0.5 mm2 to >30 mm2. Real-time deployment of this high-frame rate system is demonstrated in vivo and source code made publicly available.

14.
IEEE J Transl Eng Health Med ; 8: 4300210, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32190430

RESUMO

Cervical cancer disproportionally affects women in low- and middle-income countries, in part due to the difficulty of implementing existing cervical cancer screening and diagnostic technologies in low-resource settings. Single-board computers offer a low-cost alternative to provide computational support for automated point-of-care technologies. Here we demonstrate two new devices for cervical cancer prevention that use a single-board computer: 1) a low-cost imaging system for real-time detection of cervical precancer and 2) a low-cost reader for real-time interpretation of lateral flow-based molecular tests to detect cervical cancer biomarkers. Using a Raspberry Pi computer to provide real-time image collection and processing, we developed: 1) a low-cost, portable high-resolution microendoscope system (PiHRME); and 2) a low-cost automatic lateral flow test reader (PiReader). The PiHRME acquired high-resolution ([Formula: see text]) images of the cervix at half the cost of existing high-resolution microendoscope systems; image analysis algorithms based on convolutional neural networks were implemented to provide real-time image interpretation. The PiReader acquired and analyzed images of a point-of-care human papillomavirus (HPV) serology test with the same contrast and accuracy as a standard flatbed high-resolution scanner coupled to a laptop computer, for less than one-fifth of the cost. Raspberry Pi single-board computers provide a low-cost means to implement point-of-care tools with automatic image analysis. This work demonstrates the promise of single-board computers to develop and translate low-cost, point-of-care technologies for use in low-resource settings.

15.
Expert Rev Mol Diagn ; 19(8): 695-714, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31368827

RESUMO

Introduction: Cervical cancer mortality rates remain high in low- and middle-income countries (LMICs) and other medically underserved areas due to challenges with implementation and sustainability of routine screening, accurate diagnosis, and early treatment of preinvasive lesions. Areas covered: In this review, we first discuss the standard of care for cervical cancer screening and diagnosis in high- and low-resource settings, biomarkers that correlate to cervical precancer and cancer, and needs for new tests. We review technologies for screening and diagnosis with a focus on tests that are already in use in LMICs or have the potential to be adapted for use in LMICs. Finally, we provide perspectives on the next five years of technology development for improved cervical cancer screening and diagnosis in LMICs. Expert opinion: Innovation toward improved molecular and imaging tests is needed to enable effective, affordable see-and-treat approaches to detect and treat cervical precancer in a single visit. Current molecular tests remain too complex and/or costly for widespread use. Especially with imaging tests, decision support may improve performance of new technologies.


Assuntos
Biomarcadores/análise , Programas de Rastreamento/métodos , Neoplasias do Colo do Útero/diagnóstico , Detecção Precoce de Câncer , Feminino , Recursos em Saúde , Humanos , Testes Imediatos , Sensibilidade e Especificidade
16.
Photochem Photobiol ; 94(6): 1308-1313, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29981148

RESUMO

Proflavine is an acridine dye used with high-resolution microendoscopy for in vivo diagnostic evaluation of cervical epithelial cells. However, there are concerns that even short-term exposure of cervical tissue to dilute proflavine may increase cervical cancer risk. We performed a retrospective analysis of women referred for colposcopy to Barretos Cancer Hospital comparing the risk of cervical disease progression in those whose cervical tissue was (n = 232) or was not exposed (n = 160) to proflavine. Patients in both groups underwent treatment and follow-up based on histopathologic results and per the local standards of care. Progression of disease was evaluated by comparing histopathology from the initial visit to the worst subsequent histopathology result from all follow-up visits. Mean duration of follow-up was 18.7 and 20.1 months for the proflavine-exposed and controls groups, respectively. There were no significant differences in disease progression from normal/CIN1 to CIN2/3 or from any initial diagnosis to invasive cancer between the proflavine exposed and control groups overall. Risks of cervical dysplasia progression observed in this study are in agreement with those of the natural history of cervical cancer. Our results suggest that cervical exposure to dilute proflavine does not increase the risk of cervical precancer and cancer.


Assuntos
Colo do Útero/diagnóstico por imagem , Colposcopia/métodos , Meios de Contraste/administração & dosagem , Proflavina/administração & dosagem , Displasia do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Colo do Útero/metabolismo , Colo do Útero/patologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Risco , Neoplasias do Colo do Útero/metabolismo , Neoplasias do Colo do Útero/patologia , Displasia do Colo do Útero/metabolismo , Displasia do Colo do Útero/patologia
17.
Cancer Prev Res (Phila) ; 11(6): 359-370, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29618459

RESUMO

Cervical cancer is a leading cause of death in underserved areas of Brazil. This prospective randomized trial involved 200 women in southern/central Brazil with abnormal Papanicolaou tests. Participants were randomized by geographic cluster and referred for diagnostic evaluation either at a mobile van upon its scheduled visit to their local community, or at a central hospital. Participants in both arms underwent colposcopy, in vivo microscopy, and cervical biopsies. We compared rates of diagnostic follow-up completion between study arms, and also evaluated the diagnostic performance of in vivo microscopy compared with colposcopy. There was a 23% absolute and 37% relative increase in diagnostic follow-up completion rates for patients referred to the mobile van (102/117, 87%) compared with the central hospital (53/83, 64%; P = 0.0001; risk ratio = 1.37, 95% CI, 1.14-1.63). In 229 cervical sites in 144 patients, colposcopic examination identified sites diagnosed as cervical intraepithelial neoplasia grade 2 or more severe (CIN2+; 85 sites) with a sensitivity of 94% (95% CI, 87%-98%) and specificity of 50% (95% CI, 42%-58%). In vivo microscopy with real-time automated image analysis identified CIN2+ with a sensitivity of 92% (95% CI, 84%-97%) and specificity of 48% (95% CI, 40%-56%). Women referred to the mobile van were more likely to complete their diagnostic follow-up compared with those referred to a central hospital, without compromise in clinical care. In vivo microscopy in a mobile van provides automated diagnostic imaging with sensitivity and specificity similar to colposcopy. Cancer Prev Res; 11(6); 359-70. ©2018 AACR.


Assuntos
Colposcopia/métodos , Detecção Precoce de Câncer/estatística & dados numéricos , Microscopia/métodos , Unidades Móveis de Saúde/estatística & dados numéricos , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Feminino , Seguimentos , Humanos , Técnicas In Vitro , Vida Independente , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , População Rural , Neoplasias do Colo do Útero/epidemiologia , Displasia do Colo do Útero/epidemiologia
18.
PLoS One ; 12(5): e0177732, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28520780

RESUMO

A rapid test to identify patients with sickle cell disease could have important benefits in low-resource settings. Sickle cell anemia (SCA) affects about 300,000 newborns each year, the majority of whom are born in sub-Saharan Africa. Low-cost therapies are available to treat SCA, but most countries in sub-Saharan Africa lack robust neonatal screening programs needed to identify patients in need of treatment. To address this need, we developed and evaluated a competitive lateral flow assay that identifies patients with SCA (genotype HbSS) in 15 minutes using undiluted whole blood. A small volume of blood (0.5 µL- 3 µL) is mixed with antibody-coated blue latex beads in a tube and applied to the strip. Strips are then placed in a well of running buffer and allowed to run for 10 minutes. Laboratory evaluation with samples containing different proportions of hemoglobin A (HbA) and hemoglobin S (HbS) indicated that the test should enable identification of SCA patients but not persons with sickle cell trait (SCT). We evaluated the test using 41 samples from individuals with SCA, SCT, and normal blood. With visual inspection or quantitative analysis, we found a 98% accuracy when differentiating SCA from normal and SCT samples as a group (90% sensitivity and 100% specificity for identifying SCA). This work demonstrates important steps towards making a lateral flow test for hemoglobinopathies more appropriate for point-of-care use; further work is needed before the test is appropriate for clinical use.


Assuntos
Anemia Falciforme/sangue , Testes Imediatos/economia , Testes Sorológicos/métodos , África Subsaariana , Anticorpos Imobilizados/imunologia , Hemoglobina Falciforme/imunologia , Humanos , Recém-Nascido , Microesferas , Testes Imediatos/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Testes Sorológicos/economia , Testes Sorológicos/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA