Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Biomed Microdevices ; 22(2): 33, 2020 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-32367325

RESUMO

In this study, we report an opto-microfluidic platform integrated with dark-field light scattering imaging and fluorescence microspectroscopy to investigate the temperature-dependent behavior of nanoliposomes. This newly developed experimental platform enabled both in situ measurements of the temperature of the sample solution and observation of individual nanoliposomes. As a proof-of-concept, the temperature-dependent interaction between 1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC) nanoliposomes and a poly(ethylene glycol) (PEG) grafted surface was investigated using this opto-microfluidic platform. Temperature-dependent detachment behavior of DLPC nanoliposomes, which was because of the phase transition of DLPC, was observed. The opto-microfluidic platform for individual nanoparticle measurements may become a powerful tool for investigating temperature-dependent physicochemical properties of nanoparticles in aqueous solution.


Assuntos
Lipossomos/química , Nanoestruturas/química , Fenômenos Ópticos , Polietilenoglicóis/química , Temperatura , Dispositivos Lab-On-A-Chip , Propriedades de Superfície , Água/química
2.
Analyst ; 143(20): 4923-4929, 2018 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-30221644

RESUMO

Single-molecule digital enzyme assay using micron-sized droplet array is a promising analysis method to quantify biomolecules at extremely low concentrations. However, multiplex digital enzyme assays are still difficult to access because the best buffer conditions can vary largely among enzymes. In addition, the best conditions for flurogenic compounds to retain high quantum efficiency and to avoid leakage into the oil phase can be also very different. In this study, digital enzyme assay was performed using an array of nanometer-sized droplets of 200 aL volume, termed 'nanocell'. Due to the small reaction volume, nanocell enhanced the accumulation rate of fluorescent products by a factor of 100 when compared with micron-sized reactors. Nanocell also enabled oil-free sealing of reactors: when flushed with an air flow, nanocell displayed water droplets under air, allowing enzymes to catalyze the reaction at the same rate as in oil-sealed reactors. Dual digital enzyme assay was also demonstrated using ß-galactosidase and alkaline phosphatase (ALP) at pH 7.4, which is far from the optimum condition for ALP. Even under such a non-optimum condition, ALP molecules were successfully detected. Nanocell could largely expand the applicability of digital bioassay for enzymes under non-optimum conditions or enzymes of low turnover rate. The sealing of the reactor with air would also expand the applicability, allowing the use of fluorescent dyes that leak into oil.


Assuntos
Fosfatase Alcalina/análise , Ensaios Enzimáticos/métodos , Ensaio de Imunoadsorção Enzimática/métodos , beta-Galactosidase/análise , Ensaios Enzimáticos/instrumentação , Ensaio de Imunoadsorção Enzimática/instrumentação , Escherichia coli/enzimologia , Proteínas de Escherichia coli/análise , Fluoresceínas/química , Corantes Fluorescentes/química , Concentração de Íons de Hidrogênio
3.
Sensors (Basel) ; 17(10)2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-29027914

RESUMO

The fabrication of miniaturized electrical biosensing devices can enable the rapid on-chip detection of biomarkers such as miRNA molecules, which is highly important in early-stage cancer detection. The challenge in realizing such devices remains in the miniaturization of the reference electrodes, which is an integral part of electrical detection. Here, we report on a novel thin film Ag/AgCl reference electrode (RE) that has been fabricated on top of a Au-sputtered glass surface, which was coated with a self-assembled monolayer (SAM) of 6-mercepto-1-hexanol (MCH). The electrode showed very little measurement deviation (-1.5 mv) from a commercial Ag/AgCl reference electrode and exhibited a potential drift of only ± 0.2 mV/h. In addition, the integration of this SAM-modified microfabricated thin film RE enabled the rapid detection (<30 min) of miRNA (let-7a). The electrode can be integrated seamlessly into a microfluidic device, allowing the highly stable and fast measurement of surface potential and is expected to be very useful for the development of miniature electrical biosensors.

4.
ACS Omega ; 9(4): 4656-4663, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38313504

RESUMO

Adsorption energies of additive molecules in paint materials on the iron oxide substrate are investigated by molecular dynamics (MD) simulations to find the key feature of adhesion, which is one of the indispensable elements for the corrosion resistance of coated materials. Both edge-on and face-on adsorptions are observed for most additive molecules such as phenylsuccinic acid and benzoic acid. On the other hand, only the edge-on adsorption is observed for the specific molecule having a benzothiazole ring due to the effect of steric conformation. The largest adsorption energy per functional group is observed for two nitrogen atoms in the thiazole ring and amino group, which influences the relationship between face-on and edge-on adsorption energies. Moreover, a correlation analysis using RDKit descriptors is performed to discuss the dominant factor for the adsorption energy of additive molecules. The descriptor for the magnitude of partial charge relative to the molecular surface area and the one for the topological polar surface area have the largest correlation with the adsorption energy of the target molecules. It is significant in this study to extract key factors that contribute to molecular adhesion through MD simulations in combination with correlation analysis using RDKit descriptors. This study is a good example of the computer-assisted design of new paint materials.

5.
Electrophoresis ; 34(8): 1212-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23401269

RESUMO

The zeta potential of nanoliposomes with a diameter below 100 nm has been studied by the combined use of on-chip microcapillary electrophoresis (µCE) and sensitive fluorescence imaging. Tracking the electrophoretic migration of individual nanoliposomes has enabled the accurate evaluation of the zeta potential distribution of nanoliposomes and the first observation of its abnormal broadening due to a statistical fluctuation phenomenon specific to the "nanoscale world." The materials used for liposome preparation were phosphocholine as the neutral lipid, phosphatidylserine as the anionic lipid, and cholesterol. The size of the liposomes encapsulating calcein, a fluorescent dye used for imaging convenience, was tailored by extrusion through polycarbonate membrane filters of different pore sizes ranging from 50 to 1000 nm. The on-chip µCE system comprised a µCE chip, a laser source, an inverted microscope, and an electron-multiplying charge-coupled device camera. The electrophoresis experiment using this system revealed that the relative standard deviation of the zeta potential distribution of nanoliposomes is inversely proportional to their diameter and apparently increases below 100 nm. This abnormal broadening of zeta potential distribution of nanoliposomes is explained by prominent discreteness effect of the number of anionic lipid molecules in nanoliposomes.


Assuntos
Eletroforese em Microchip/métodos , Lipossomos/química , Nanopartículas/química , Fluoresceínas/química , Corantes Fluorescentes/química , Tamanho da Partícula , Fosfatidilserinas/química , Fosforilcolina/química , Porosidade , Reprodutibilidade dos Testes
6.
J Extracell Vesicles ; 11(3): e12205, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35289089

RESUMO

The development of a new large-scale purification protocol is required for research on the reliable bioactivity and drug discovery of extracellular vesicles (EVs). To address this issue, herein, we propose an effective method for preparing high-performance exosomes (EXOs) by using an anion-exchange method. Cytotoxic T-lymphocyte (CTL) EVs from 4 L of culture supernatant through a 220 nm cut-off filter are divided into two populations at a deproteinization rate of over 99.97%, which are eluted at low (0.15 M-0.3 M) and high (0.3 M-0.5 M) NaCl concentrations (approximately 2 × 1012 and 1.5 × 1012 particles, respectively) through the anion-exchange column chromatography. The former are abundant in EXO proteins, including late endosome-associated proteins and rab-family and integrin-family proteins, and functional micro (mi) RNAs, and have bioactivity for preventing tumour metastasis by depleting mesenchymal cell populations in the primary tumour lesions. By contrast, the latter is microvesicle (MV)-like particles including DNA, core histone and ribosomal proteins, and GC-rich miRNAs with unknown function, and are easily phagocytosed by mannose receptor+ Kupffer cells. Thus, the anion-exchange method is suitable for the large-scale separation of bioactive EXOs and MV-like EVs as a cargo for dangerous nucleic acids at high-purity.


Assuntos
Exossomos , Vesículas Extracelulares , Neoplasias , Ácidos Nucleicos , Ânions/análise , Exossomos/genética , Vesículas Extracelulares/química , Humanos , Neoplasias/diagnóstico , Ácidos Nucleicos/análise
7.
iScience ; 25(11): 105416, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36439984

RESUMO

Congenital disorders characterized by the quantitative and qualitative reduction in the number of functional nephrons are the primary cause of chronic kidney disease (CKD) in children. We aimed to describe the alteration of urinary extracellular vesicles (uEVs) associated with decreased renal function during childhood. By nanoparticle tracking analysis and quantitative proteomics, we identified differentially expressed proteins in uEVs in bilateral renal hypoplasia, which is characterized by a congenitally reduced number of nephrons. This expression signature of uEVs reflected decreased renal function in CKD patients by congenital anomalies of the kidney and urinary tract or ciliopathy. As a proof-of-concept, we constructed a prototype ELISA system that enabled the isolation of uEVs and quantitation of expression of molecules representing the signature. The system identified decreased renal function even in its early stage. The uEVs signature could pave the way for non-invasive methods that can complement existing testing methods for diagnosing kidney diseases.

8.
Anal Biochem ; 409(1): 105-11, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20950583

RESUMO

We designed a new approach for selection of translation enhancer sequences that enables efficient protein synthesis in cell-free systems. The selection is based on a gel shift assay of a messenger RNA (mRNA)-protein fusion product that is synthesized in a cell-free translation system using an mRNA display method. A library of randomized 20-nt-long sequences, with all possible combinations of the four nucleotides, upstream of a coding region was screened by successive rounds of screening in which the translation time of the succeeding round was reduced compared with the previous round. An efficient translation enhancer sequence capable of more rapid initiation of cell-free protein synthesis, with a minimal translation time of 5 min, than a natural longer enhancer sequence (Xenopus ß-globin 5'UTR) was selected using rabbit reticulocyte extract as a model cell-free translation system. Furthermore, a successful screening of cap-independent translation enhancer sequence and a significant sequence similarity of the selected candidates validated the efficiency of the combined mRNA display and gel shift assay method for the rapid development of advanced cell-free translation systems.


Assuntos
Regiões 5' não Traduzidas , Ensaio de Desvio de Mobilidade Eletroforética/métodos , Biossíntese de Proteínas , RNA Mensageiro/química , Animais , Sequência de Bases , Sistema Livre de Células , Proteínas/química , Coelhos , Reticulócitos/metabolismo , Xenopus/metabolismo , Globinas beta/genética
9.
Micromachines (Basel) ; 11(5)2020 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-32344884

RESUMO

The micromolding process using biocompatible thermoplastic polymers is highly attractive as a fabrication process of microdevices in biomedical applications. In this study, we investigated the effect of the thermal history in the micromolding process on the crystallinity of semi-crystalline polymers, such as poly (L-lactic acid) (PLLA), during their crystallization from the amorphous and molten states. In particular, the thermal history in the micromolding process using poly(dimethylsiloxane) replica mold embedded with a thermocouple was recorded. The crystallinity of PLLA constructs fabricated using the micromolding process was measured via wide-angle X-ray scattering, and crystallization kinetics was analyzed based on the Kolmogorov-Johnson-Mehl-Avrami equation. A crystallization rate of k = 0.061 min-n was obtained in the micromolding process of PLLA crystallization from the amorphous state, accompanied by the quenching operation, forming a large number of crystal nuclei. Finally, the fabrication of PLLA microneedles was performed using micromolding processes with different thermal histories. The information about the thermal history during the micromolding process is significant in the development of polymer microdevices to achieve better material properties.

10.
Chem Commun (Camb) ; 56(66): 9477-9480, 2020 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-32677638

RESUMO

A photo-responsive nanovesicle is fabricated by polyion complex (PIC) formation between poly(ethylene glycol) (PEG)-block-polypeptides and photo-reactive oligodeoxynucleotides (PROs)/anti-sense oligonucleotides (ASOs). The ultraviolet (UV) light triggers reversible crosslinking between PROs and ASOs in the vesicular membrane, providing the nanovesicle with switchable stability under physiological conditions. The resulting nanovesicle allows efficient cellular internalization, leading to significant UV-triggered gene knockdown in cultured cells.


Assuntos
Técnicas de Silenciamento de Genes/métodos , Nanoestruturas/química , Oligodesoxirribonucleotídeos/química , Raios Ultravioleta , Células A549 , Dano ao DNA/efeitos dos fármacos , Dano ao DNA/efeitos da radiação , Corantes Fluorescentes/química , Humanos , Microscopia Confocal , Nanoestruturas/toxicidade , Peptídeos/química , Polietilenoglicóis/química
11.
PLoS One ; 14(10): e0224091, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31648253

RESUMO

Arraying individual extracellular vesicles (EVs) on a chip is expected one of the promising approaches for investigating their inherent properties. In this study, we immobilized individual EVs on a surface using a nanopatterned tethering chip-based versatile platform. A microfluidic device was used to ensure soft, reproducible exposure of the EVs over the whole chip surface. The device is incorporated with a high-density nanoarray chip patterned with 200-nm diameter nanospots composed of polyethylene glycol (PEG)-lipid conjugate brushes. We present a procedure adopted for fabricating high-density PEG-lipid modified nanospots (200 nmϕ, 5.0 × 105 spots/mm2 in 2 × 2 mm2 area). This procedure involves nanopatterning using electron beam lithography, followed by multistep selective chemical modification. Aqueous treatment of a silane coupling agent, used as a linker between PEG-lipid molecules and the silicon surface, was the key step that enabled surface modification using a nanopatterned resist film as a mask. The nanoarray chip was removed from the device for subsequent measurements such as atomic force microscopy (AFM). We developed a prototype device and individually immobilized EVs derived from different cell lines (Sk-Br-3 and HEK293) on tethering nanospots. We characterized EV's morphology using AFM and showed the possibility of evaluating the deformability of EVs using the aspect ratio as an indicator.


Assuntos
Vesículas Extracelulares/química , Vesículas Extracelulares/metabolismo , Dispositivos Lab-On-A-Chip , Lipídeos/química , Nanotecnologia/instrumentação , Polietilenoglicóis/química , Células HEK293 , Humanos , Microscopia de Força Atômica , Nanotecnologia/métodos
12.
J Extracell Vesicles ; 8(1): 1579541, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30834072

RESUMO

Phosphatidylserine (PS) has skewed distributions in the plasma membrane and is preferentially located in the inner leaflet of normal cells. Tumour cells, however, expose PS at the outer leaflet of cell surfaces, thereby potentially modulating the bio-signalling of cells. Interestingly, exosomes - or, more properly, small extracellular vesicles (sEVs) - which are secreted from tumour cells, are enriched with externalized PS, have been proposed as being involved in the progression of cancers, and could be used as a marker for tumour diagnostics. However, the sEV fractions prepared from various methods are composed of different subtypes of vesicles, and knowledge about the subtypes enriched with exposed PS is still limited. Here, we differentiated sEVs from cancer cell lines by density gradient centrifugation and characterized the separated fractions by using gold-labelling of PS in atomic force microscopy, thrombin generation assay, size and zeta potential measurements, and western blot analysis. These analyses revealed a previously unreported PS+-enriched sEV subtype, which is characterized by a lower density than that of canonical exosomes (1.06 g/ml vs. 1.08 g/ml), larger size (122 nm vs. 105 nm), more negative zeta potential (-28 mV vs. -21 mV), and lower abundance of canonical exosomal markers. The identification of the PS-exposed subtype of sEVs will provide deeper insight into the role of EVs in tumour biology and enhance the development of EV-based tumour diagnosis and therapy.

13.
Anal Bioanal Chem ; 391(7): 2433-41, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18553186

RESUMO

An overview of both experimental and theoretical studies of cell electrophoresis mobility (EPM) over the past fifty years and the relevance of cell EPM measurement are presented and discussed from the viewpoint of exploring the potential use of cell EPM as an index of the biological condition of cells. Physical measurements of the optical and/or electrical properties of cells have been attracting considerable attention as noninvasive cell-evaluation methods that are essential for the future of cell-based application technologies such as cell-based drug screening and cell therapy. Cell EPM, which can be measured in a noninvasive manner by cell electrophoresis, reflects the electrical and mechanical properties of the cell surface. Although the importance of cell EPM has been underestimated for a long time, mostly owing to the technical difficulties associated with its measurement, recent improvements in measurement technology using microcapillary chips have been changing the situation: cell EPM measurement has become more reliable and faster. Recent studies using the automated microcapillary cell electrophoresis system have revealed the close correlation between cell EPM and important biological phenomena including cell cycle, apoptosis, enzymatic treatment, and immune reaction. In particular, the converged EPM distribution observed for synchronized cells has altered the conventional belief that cell EPMs vary considerably. Finding a new significance of cell EPM is likely to lead to noninvasive cell evaluation methods essential for the next-generation of cell engineering.


Assuntos
Técnicas Citológicas/métodos , Eletroforese Capilar/métodos , Procedimentos Analíticos em Microchip/métodos , Fenômenos Fisiológicos Celulares , Técnicas Citológicas/instrumentação , Eletroforese Capilar/instrumentação , Dispositivos Lab-On-A-Chip
14.
Methods Mol Biol ; 1660: 209-217, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28828659

RESUMO

A microcapillary chip-based particle electrophoresis system developed for characterizing extracellular vesicles (EVs) is described. So far, it is technologically difficult to analyze or identify a heterogeneous population of particles ranging from several tens to one hundred nanometers, and hence, there is a growing demand for a new analytical method of nanoparticles among researchers working on extracellular vesicles. The analytical platform presented in this chapter allows detection of individual nanoparticles or nanovesicles of less than 50 nm in diameter and enables the characterization of nanoparticles based on multiple indexes such as concentration, diameter, zeta potential, and surface antigenicity. This platform will provide a useful and easy-to-use solution for obtaining both quantitative and qualitative information on EV samples used in research and development of exosome biology and medicine.


Assuntos
Eletroforese Capilar/métodos , Vesículas Extracelulares , Dispositivos Lab-On-A-Chip , Linhagem Celular , Exossomos/metabolismo , Vesículas Extracelulares/metabolismo , Humanos , Proteínas de Membrana/metabolismo , Microfluídica/instrumentação , Microfluídica/métodos , Microscopia/métodos
15.
Sci Rep ; 6: 26651, 2016 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-27221801

RESUMO

Dendritic spine generation and elimination play an important role in learning and memory, the dynamics of which have been examined within the neocortex in vivo. Spine turnover has also been detected in the absence of specific learning tasks, and is frequently exaggerated in animal models of autistic spectrum disorder (ASD). The present study aimed to examine whether the baseline rate of spine turnover was activity-dependent. This was achieved using a microfluidic brain interface and open-dura surgery, with the goal of abolishing neuronal Ca(2+) signaling in the visual cortex of wild-type mice and rodent models of fragile X syndrome (Fmr1 knockout [KO]). In wild-type and Fmr1 KO mice, the majority of baseline turnover was found to be activity-independent. Accordingly, the application of matrix metalloproteinase-9 inhibitors selectively restored the abnormal spine dynamics observed in Fmr1 KO mice, without affecting the intrinsic dynamics of spine turnover in wild-type mice. Such findings indicate that the baseline turnover of dendritic spines is mediated by activity-independent intrinsic dynamics. Furthermore, these results suggest that the targeting of abnormal intrinsic dynamics might pose a novel therapy for ASD.


Assuntos
Espinhas Dendríticas/metabolismo , Espinhas Dendríticas/patologia , Síndrome do Cromossomo X Frágil/metabolismo , Síndrome do Cromossomo X Frágil/patologia , Córtex Visual/metabolismo , Córtex Visual/patologia , Animais , Espinhas Dendríticas/genética , Modelos Animais de Doenças , Proteína do X Frágil da Deficiência Intelectual/genética , Proteína do X Frágil da Deficiência Intelectual/metabolismo , Síndrome do Cromossomo X Frágil/genética , Camundongos , Camundongos Knockout
16.
Microarrays (Basel) ; 4(3): 311-23, 2015 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-27600226

RESUMO

Advances in lithographic approaches to fabricating bio-microarrays have been extensively explored over the last two decades. However, the need for pattern flexibility, a high density, a high resolution, affordability and on-demand fabrication is promoting the development of unconventional routes for microarray fabrication. This review highlights the development and uses of a new molecular lithography approach, called "microintaglio printing technology", for large-scale bio-microarray fabrication using a microreactor array (µRA)-based chip consisting of uniformly-arranged, femtoliter-size µRA molds. In this method, a single-molecule-amplified DNA microarray pattern is self-assembled onto a µRA mold and subsequently converted into a messenger RNA or protein microarray pattern by simultaneously producing and transferring (immobilizing) a messenger RNA or a protein from a µRA mold to a glass surface. Microintaglio printing allows the self-assembly and patterning of in situ-synthesized biomolecules into high-density (kilo-giga-density), ordered arrays on a chip surface with µm-order precision. This holistic aim, which is difficult to achieve using conventional printing and microarray approaches, is expected to revolutionize and reshape proteomics. This review is not written comprehensively, but rather substantively, highlighting the versatility of microintaglio printing for developing a prerequisite platform for microarray technology for the postgenomic era.

17.
PLoS One ; 10(12): e0143774, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26624889

RESUMO

A novel flexible sensor was developed for the noninvasive oxygen metabolism measurement of cultivated cells and tissues. This device is composed of a transparent double-layered polymer sheet of ethylene-vinyl alcohol (EVOH) and poly(dimethylsiloxane) (PDMS) having an array of microhole structures of 90 µm diameter and 50 µm depth on its surface. All the microhole structures were equipped with a 1-µm-thick optical chemical sensing layer of platinum porphyrin-fluoropolymer on their bottom. The three-dimensional microstructures of the sensor were fabricated by a newly developed simple and low-cost production method named self-aligned hot embossing. The device was designed to be attached slightly above the cells cultivated on a dish to form a temporarily closed microspace over the target cells during measurement. Since the change in oxygen concentration is relatively fast in the microcompartmentalized culture medium, a rapid evaluation of the oxygen consumption rate is possible by measuring the phosphorescence lifetime of the platinum porphyrin-fluoropolymer. The combined use of the device and an automated optical measurement system enabled the high-throughput sensing of cellular oxygen consumption (100 points/min). We monitored the oxygen metabolism of the human breast cancer cell line MCF7 on a Petri dish and evaluated the oxygen consumption rate to be 0.72 ± 0.12 fmol/min/cell. Furthermore, to demonstrate the utility of the developed sensing system, we demonstrated the mapping of the oxygen consumption rate of rat brain slices and succeeded in visualizing a clear difference among the layer structures of the hippocampus, i.e., the cornu ammonis (CA1 and CA3) and dentate gyrus (DG).


Assuntos
Medições Luminescentes/métodos , Consumo de Oxigênio , Animais , Encéfalo/metabolismo , Dimetilpolisiloxanos/química , Humanos , Células MCF-7 , Platina/química , Porfirinas/química , Ratos
18.
PLoS One ; 10(4): e0123603, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25928805

RESUMO

Extracellular vesicles (EVs) including exosomes and microvesicles have attracted considerable attention in the fields of cell biology and medicine. For a better understanding of EVs and further exploration of their applications, the development of analytical methods for biological nanovesicles has been required. In particular, considering the heterogeneity of EVs, methods capable of measuring individual vesicles are desired. Here, we report that on-chip immunoelectrophoresis can provide a useful method for the differential protein expression profiling of individual EVs. Electrophoresis experiments were performed on EVs collected from the culture supernatant of MDA-MB-231 human breast cancer cells using a measurement platform comprising a microcapillary electrophoresis chip and a laser dark-field microimaging system. The zeta potential distribution of EVs that reacted with an anti-human CD63 (exosome and microvesicle marker) antibody showed a marked positive shift as compared with that for the normal immunoglobulin G (IgG) isotype control. Thus, on-chip immunoelectrophoresis could sensitively detect the over-expression of CD63 glycoproteins on EVs. Moreover, to explore the applicability of on-chip immunoelectrophoresis to cancer diagnosis, EVs collected from the blood of a mouse tumor model were analyzed by this method. By comparing the zeta potential distributions of EVs after their immunochemical reaction with normal IgG, and the anti-human CD63 and anti-human CD44 (cancer stem cell marker) antibodies, EVs of tumor origin circulating in blood were differentially detected in the real sample. The result indicates that the present method is potentially applicable to liquid biopsy, a promising approach to the low-invasive diagnosis of cancer.


Assuntos
Neoplasias da Mama/metabolismo , Micropartículas Derivadas de Células/metabolismo , Procedimentos Analíticos em Microchip , Animais , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Micropartículas Derivadas de Células/patologia , Feminino , Humanos , Dispositivos Lab-On-A-Chip , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus
19.
Biosens Bioelectron ; 67: 115-20, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25106674

RESUMO

We have developed an advanced microintaglio printing method for fabricating fine and high-density micropatterns and applied it to the microarraying of RNA molecules. The microintaglio printing of RNA reported here is based on the hybridization of RNA with immobilized complementary DNA probes. The hybridization was controlled by switching the RNA conformation via the temperature, and an RNA microarray with a diameter of 1.5 µm and a density of 40,000 spots/mm(2) with high contrast was successfully fabricated. Specifically, no size effects were observed in the uniformity of patterned signals over a range of microarray feature sizes spanning one order of magnitude. Additionally, we have developed a microintaglio printing method for transcribed RNA microarrays on demand using DNA-immobilized magnetic beads. The beads were arrayed on wells fabricated on a printing mold and the wells were filled with in vitro transcription reagent and sealed with a DNA-immobilized glass substrate. Subsequently, RNA was in situ synthesized using the bead-immobilized DNA as a template and printed onto the substrate via hybridization. Since the microintaglio printing of RNA using DNA-immobilized beads enables the fabrication of a microarray of spots composed of multiple RNA sequences, it will be possible to screen or analyze RNA functions using an RNA microarray fabricated by temperature-controlled microintaglio printing (TC-µIP).


Assuntos
Técnicas Biossensoriais , Análise de Sequência com Séries de Oligonucleotídeos , RNA/química , Sequência de Bases , DNA Complementar/química , DNA Complementar/genética , Hibridização de Ácido Nucleico , Impressão , RNA/genética
20.
J Nanobiotechnology ; 2(1): 5, 2004 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-15176978

RESUMO

Studying cell functions for cellomics studies often requires the use of purified individual cells from mixtures of various kinds of cells. We have developed a new non-destructive on-chip cell sorting system for single cell based cultivation, by exploiting the advantage of microfluidics and electrostatic force. The system consists of the following two parts: a cell sorting chip made of poly-dimethylsiloxane (PDMS) on a 0.2-mm-thick glass slide, and an image analysis system with a phase-contrast/fluorescence microscope. The unique features of our system include (i) identification of a target from sample cells is achieved by comparison of the 0.2-microm-resolution phase-contrast and fluorescence images of cells in the microchannel every 1/30 s; (ii) non-destructive sorting of target cells in a laminar flow by application of electrostatic repulsion force for removing unrequited cells from the one laminar flow to the other; (iii) the use of agar gel for electrodes in order to minimize the effect on cells by electrochemical reactions of electrodes, and (iv) pre-filter, which was fabricated within the channel for removal of dust contained in a sample solution from tissue extracts. The sorting chip is capable of continuous operation and we have purified more than ten thousand cells for cultivation without damaging them. Our design has proved to be very efficient and suitable for the routine use in cell purification experiments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA