Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Appl Radiat Isot ; 170: 109559, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33476941

RESUMO

From a commercial supplier, three independent lots of an aqueous solution containing 223Ra in equilibrium with its deteriorating progeny were considered for standardization, by using live-time anticoincidence counting (LTAC) in the Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI) Brazil. The ionization chamber calibration factors were obtained using measurements of independent lots of 223Ra in LTAC considering the absolute method in order to evaluate the constancy and reproducibility of the standardization. The calibration factors of three high-performance well-type ionization chamber systems and four commercial well-type ionization chambers were determined. The LTAC results showed that lots 2 and 3 were 1069.88 and 1097.44 kBq/kg, with corresponding relative standard uncertainties 0.12% and 0.20%, respectively. The spectrometry method results of each lot value were classified as positive by ANOVA hypothesis testing. The emission probabilities relating to the X- and γ-rays in region from 81 to 830 keV ware determined. Hence, LNMRI can provide calibration services for 223Ra.

2.
J Nutr Health Aging ; 24(8): 878-882, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33009539

RESUMO

AIM: This is a cross-sectional study of relation between metabolic syndrome and cognitive function in community-dwelling non-demented older adults in Japan. We examine the effect of metabolic syndrome and its components on global cognitive function. We also aim to clarify differences of specific cognitive domains between the subjects with and without metabolic syndrome. METHODS: We studied 2150 subjects aged between 60 and 90 years whose scores on mini mental state examination (MMSE) were over 23 points. We analyzed difference in MMSE scores between the subjects with and without metabolic syndrome. Logistic regression analysis was performed with MMSE score as the dependent variable and metabolic syndrome components as the independent variable adjusted with age. We also examined differences in attention, logical memory, and verbal and category fluency between the subjects with and without metabolic syndrome. RESULTS: MMSE scores were not significantly different between subjects with and without metabolic syndrome. In logistic regression analysis, the score of MMSE was significantly negatively associated with triglycerides in males and significantly negatively associated with abdominal circumference in females. Subjects with metabolic syndrome showed significantly lower performance of attention tasks compared to subjects without metabolic syndrome. CONCLUSIONS: Our results suggest that in community-dwelling non-demented Japanese older adults, attention but not global cognitive function may be impaired by metabolic syndrome. Inverted association between some components of metabolic syndrome and global cognitive function indicate necessity of further studies on the relation between undernutrition and cognitive function.


Assuntos
Cognição/fisiologia , Síndrome Metabólica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Vida Independente , Japão , Masculino
3.
Appl Radiat Isot ; 166: 109323, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32795698

RESUMO

There are few long-lived radionuclides yielding high intensity gamma-rays emission with energies ranging from 100 keV to 500 keV that can be applied as radioactive gamma standard to calibrate HPGe detectors. Furthermore, this energy range represents the main emitted energies of the majority of radionuclides used in nuclear medicine. The Brazilian National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) has attempted to identify radionuclides that have the potential to be used as a calibration source due to their long half-life as well as their emission spectrum. Hence, LNMRI promotes standardization studies of gamma-emitting radionuclides that meet these criteria on order to disseminate them. Thorium-229, with its well-defined energies and relatively high intensities, is one such candidate radionuclide for the energy and full-energy peak efficiency calibration of high-purity gamma spectrometers. Thorium-229 was standardized by the method of 4παß(LS)-γ(NaI(Tl)) live timed anticoincidence counting. The emission intensities of gamma-rays associated with the decay of 229Th have been determined by HPGe gamma ray spectrometry with accuracy and precision. The results are in agreement with current literature data.

4.
Appl Radiat Isot ; 66(2): 231-5, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17904854

RESUMO

In this work, the activity standardization of 51Cr, 55Fe and 67Ga by live-timed anti-coincidence counting with extending dead time is described. The difficulties of the method, the uncertainties of the results of the measurements and the comparison of these results with others measurement methods are discussed.

5.
Appl Radiat Isot ; 66(6-7): 886-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18356060

RESUMO

The National Metrology Laboratory for Ionizing Radiation (LNMRI)/Brazil has implemented a live-timed anti-coincidence system with extending dead time to complement the existing systems in its Radionuclide Laboratory for activity measurements of radioactive sources. In this new system, the proportional counter has been replaced by a liquid-scintillation-counter for alpha and beta detection. In order to test the performance of the new system, radioactive solutions of (131)I, (124)Sb and (241)Am have been standardized. In this work the measurement method, the results and the associated uncertainties are described and discussed.

6.
Appl Radiat Isot ; 134: 64-67, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28942991

RESUMO

Traceability in Nuclear Medicine Service (NMS) measurements was checked by the Institute of Radioprotection and Dosimetry (IRD) through the Institute of Energy and Nuclear Research (IPEN). In 2016, IRD ran an intercomparison program and invited Brazilian NMS authorized to administer 131I to patients. Sources of 131I were distributed to 33 NMSs. Three other sources from the same solution were sent to IRD, after measurement at IPEN. These sources were calibrated in the IRD reference system. A correction factor of 1.013 was obtained. Ninety percent of the NMS comparisons results are within ±10% of the National Laboratory of Metrology of Ionizing Radiation (LNMRI) value, the Brazilian legal requirement.


Assuntos
Instituições de Assistência Ambulatorial , Radioisótopos do Iodo/análise , Serviço Hospitalar de Medicina Nuclear , Compostos Radiofarmacêuticos/análise , Brasil , Calibragem , Competência Profissional , Controle de Qualidade , Reprodutibilidade dos Testes , Fatores de Tempo , Incerteza
7.
Appl Radiat Isot ; 134: 307-311, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29153654

RESUMO

In this work, a 68(Ge+Ga) solution has been standardized at the National Institute of Ionizing Radiation Metrology (LNMRI), in Brazil, in the frame of an international key comparison CCRI(II)-K2.Ge-68 piloted by National Institute of Standards and Technology (NIST/USA). The 4πß(LS)-γ(NaI(Tl)) anticoincidence method with live-time and extended dead-time was used and its result was validated by 4πß(LS)-γ(NaI(Tl)) coincidence counting and liquid scintillation counting using the Triple to Double Coincidence Ratio (TDCR) method. The deviations of the activity concentration values of coincidence and TDCR measurements from the anticoincidence result were 1.7% and 0.63%, respectively, which were within experimental evaluated uncertainties at ~95% level of confidence (coverage factor k = 2). The combined relative standard uncertainties were 0.65%, 0.70% and 0.53% for anticoincidence, coincidence and TDCR methods, respectively. These values are consistent with the results reported by Cessna at the ICRM2017 conference.

8.
Appl Radiat Isot ; 134: 316-320, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29107514

RESUMO

From a commercial supplier a solution containing 134Cs has been standardized at National Laboratory for Ionizing Radiation Metrology (LNMRI) for the first time using three Liquid scintillation based measurement. These measurement methods are 4πß-γ live-timed anticoincidence counting, 4πß-γ coincidence counting and 3H-standard efficiency tracing with the CNET methods. The results obtained by anticoincidence counting was adopted as reference value and its combined uncertainty was 0.38%. The agreement of this reference value with coincidence counting and CNET methods were 0.39% and 0.34% respectively and were in consistency with each uncertainty method. The weighted mean results coincidence counting and CNET methods are also in close agreement 0.03% with anticoincidence counting method and meets the requirement of primary and national standard. This standardization was made in order to reduce the uncertainty in 134Cs measurement in Brazil and also following a request made by Bureau International des Poids and Mesures for new submission to International Reference System. The LNMRI last submission was made in 1987. Therefore from a 134Cs master solution a NIST ampoules was prepared and LNMRI/IRD submitted it to the International Reference System, Bureau International of Poids and Measures (SIR/BIPM). In this paper will be analyzed the LNMRI measurement and performance each measurement methods and also take into account the reference value of KCDB, we determined also the 134Cs gamma emission probabilities of main energy.

9.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29248210

RESUMO

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

10.
Appl Radiat Isot ; 122: 37-40, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28092780

RESUMO

The absolute activity standardization measurement system of radionuclide by live-timed anticoincidence counting was implemented at LNMRI in 2008 to reduce the effects of some correction factors on the determination of activity with coincidence counting technique used for decades in the laboratory, for example, the corrections of dead time and resolution. With the live-timed anticoincidence system, the variety of radionuclides that can be calibrated by LNMRI was increased in relation to the type of decay. The objective of this study was to standardize the 106Ru activity, determine gamma emission probabilities by spectrometric method for some energies, and estimate measurement uncertainties.

11.
Appl Radiat Isot ; 64(10-11): 1440-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16621584

RESUMO

The absolute 4pi-betagamma coincidence counting has been used to measure the activity concentrations of 54Mn and 203Hg, and the Sum-Peak method was used for 125I. 54Mn and 125I radionuclides have been part of international key-comparisons coordinated by the Bureau International des Poids et Measures (BIPM) in 2003/2004, while 203Hg is part of the traceability programme of the National Laboratory for Ionizing Radiation Metrology (LNMRI)/Brazil. Three different detectors were used for the Sum-Peak method: 3''x3'' NaI(Tl) and 5''x5'' well NaI(Tl) scintillation detectors and a planar germanium detector. Direct measurements were made of the photon emission probabilities of the 35.5-, 834.8- and 279.2-keV gamma-rays of 125I, 54Mn and 203Hg to give values of (0.0667+/-0.0014), (0.9997+/-0.0055) and (0.8161+/-0.0005), respectively. The half-lives of 203Hg and 54Mn were also determined by means of a 4pigamma ionization chamber (203Hg) and by the reference source method using a HPGe detector (54Mn) to give values of (46.639+/-0.023) days and (312.1+/-0.9) days, respectively.


Assuntos
Modelos Químicos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/métodos , Brasil , Simulação por Computador , Guias como Assunto , Meia-Vida , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/química , Radioisótopos do Iodo/normas , Manganês/análise , Manganês/química , Manganês/normas , Radioisótopos de Mercúrio/análise , Radioisótopos de Mercúrio/química , Radioisótopos de Mercúrio/normas , Doses de Radiação , Radioisótopos/química , Radiometria/normas , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Appl Radiat Isot ; 109: 389-392, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26805708

RESUMO

(123)I is widely used for radiodiagnostic procedures. It is produced by reaction of (124)Xe (p,2n) (123)Cs →(123)Xe →(123)I in cyclotrons. (121)Te and (125)I appear in a photon energy spectrum as impurities. An activity of (121)Te was calibrated absolutely by sum-peak method and its photon emitting probability was estimated, whose results were consistent with published results.

13.
Appl Radiat Isot ; 109: 236-241, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26688362

RESUMO

Since the inception of its proficiency test program to evaluate radionuclide measurement in hospitals and clinics, the National Metrology Laboratory of Ionizing Radiation-LNMRI, that represents Brazilian National Metrology Institute (NMI) for ionizing radiation has expanded its measurement and calibration capability. Requirements from the National Health Surveillance Agency from Ministry of Health (ANVISA), to producers of radiopharmaceuticals provided an opportunity to improve the full traceability chain to the highest level. Fluorodeoxyglucose (FDG-(18)F) is the only radiopharmaceutical simultaneously produced by all Brazilian radiopharmaceutical production centers (RPCs). By running this proficiency test, LNMRI began to provide them with the required traceability. For evaluation, the ratio of RPC to reference value results and ISO/IEC17043:2010 criteria were used. The reference value established as calibration factor on the secondary standard ionization chamber was obtained from three absolute measurements systems, and routinely confirmed in each round of proficiency test by CIEMAT/NIST liquid scintillation counting. The γ-emitting impurities were checked using a High-Purity Germanium (HPGe) detector. The results show that Brazilian RPCs are in accordance with (accuracy within ±10%) the Brazilian standard for evaluation of measurements with radionuclide calibrators (CNEN NN 3.05., 2013). Nevertheless, the RPCs should improve the methodology of uncertainty estimates, essential when using the statistical criteria of ISO/IEC 17043 standard, in addition to improving accuracy to levels consistent with their position in the national traceability chain.


Assuntos
Radioisótopos de Flúor/análise , Radioisótopos de Flúor/normas , Setor Público/normas , Radiometria/métodos , Radiometria/normas , Brasil , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Appl Radiat Isot ; 54(3): 483-7, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11214885

RESUMO

A solution of 169Yb was absolutely standardized by the 4pi(EC,X)-gamma coincidence counting method and the result was used to obtain direct measurements of gamma-ray emission probabilities with a coaxial HPGe detector. The empirical relation proposed by (Vaño, F., Gonzalez, L., Gaeta R., Gonzalez, J.A., 1975. An empirical function which relates the slope of the Ge efficiency curves and the active volume Nucl. Instr. Meth. 123, 573) was tested using the gamma spectral response above 200 keV. The half-life of 169Yb was also measured with a 4pi gamma ionization chamber.

15.
Appl Radiat Isot ; 54(3): 489-96, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11214886

RESUMO

This work outlines the quality assurance program for the activity measurements of the most used radionuclides at Brazilian Nuclear Medicine Services (NMS). The program aims to guarantee that the patient is given the correct prescribed amount of activity in diagnostic or therapeutic applications. This accurate administration depends upon proper use and calibration of the activity meters by the NMS. Underestimation of administered activity in diagnostic practices could delay correct diagnosis disturbing the value of the investigation. On the other hand, the overestimation would be worse, mainly in therapeutic applications, because an unnecessarily high absorbed dose would be delivered to the patient. The preliminary results of intercomparison for 131I and 99mTc showed that many activity meters used at NMS's present problems giving results up to 41% greater than the reference values determined at the National Metrology Laboratory for Ionizing Radiation (LNMRI) which is recognized as the Brazilian authorized metrology laboratory for ionizing radiation. These results have demonstrated that the NMS should improve the accuracy of the activity measurements of the radionuclides administered to the patients and establish the traceability to the national standards of measurements. These standards are based on a pressurized well-type ionization chamber installed at LNMRI and calibrated with reference sources standardized by absolute methods. The protocol of the intercomparison and recommendations made in order to minimize errors in measuring procedures are described and results are discussed.


Assuntos
Medicina Nuclear/normas , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/normas , Tecnécio/análise , Tecnécio/normas , Brasil , Humanos , Controle de Qualidade
16.
Appl Radiat Isot ; 56(1-2): 361-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11842803

RESUMO

In order to obtain information on the accuracy of activity measurements in Brazilian hospitals, several intercomparison exercises have been organized since 1998. The first exercise consisted of two intercomparison runs of 131I and 99mTc and had the participation of 21 hospitals localized in Rio de Janeiro city and surroundings. The second, with 131I (47 hospitals) and 123I (12 hospitals), had the participation of hospitals localized in the whole country. The results were analyzed under the statistical point of view and conformity to the norms of Regulatory Authority. These results have shown that such exercises are necessary to improve the quality of the measurements and to identify those instruments that are producing incorrect values.


Assuntos
Radioisótopos/análise , Radioisótopos/normas , Radiometria/normas , Brasil , Hospitais , Humanos , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/normas , Padrões de Referência , Tecnécio/análise , Tecnécio/normas , Tecnologia Radiológica
17.
Percept Mot Skills ; 91(3 Pt 1): 725-8, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11153838

RESUMO

How 352 Japanese university students regard web-site information was investigated by two kinds of survey. Application of correspondence analysis and cluster analysis to the questionnaire responses to the web-site advertisement showed students regarded a web-site as a new alien medium which is different from current media. Students regarded web-sites as simply complicated, intellectual, and impermanent, or not memorable. Students got precise information from web-sites but they did not use it in making decisions to purchase goods.


Assuntos
Atitude Frente aos Computadores , Etnicidade/psicologia , Internet , Estudantes/psicologia , Adolescente , Adulto , Comparação Transcultural , Tomada de Decisões , Feminino , Humanos , Japão , Masculino
18.
Appl Radiat Isot ; 87: 188-91, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24361323

RESUMO

In order to maintain the results of primary activity standardizations carried out in 2011 the LNMRI has determined the calibration factors for a pressurized 4π-ionization chamber for the nuclides (18)F and (68)Ga. This ionization chamber is coupled to a 6517A Keithley electrometer which is controlled by a homemade LabVIEW program. This paper will describe the main issues related to the calibration of an ionization chamber system for positron emitters and short half-life radionuclides such as timing, current measurement, background, decay, and (226)Ra check source measurements.

19.
Appl Radiat Isot ; 70(9): 1924-6, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22406221

RESUMO

The National Laboratory for Metrology of Ionizing Radiation (LNMRI)/Brazil participated in the last (57)Co activity measurement comparison organized by IAEA, in 2008. This was made in order to realize primary standardization of this radionuclide and to reduce the measuring uncertainties in the laboratory. Additionally, one sample with 2.6g was taken from the IAEA master solution of (57)Co and was prepared to be used in the measurement of the radionuclide's half-life in an ionization chamber system. The (57)Co half-life was measured to be 271.82 (17) days.


Assuntos
Radioisótopos de Cobalto/análise , Radioisótopos de Cobalto/química , Radiometria/instrumentação , Radiometria/normas , Brasil , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
20.
Appl Radiat Isot ; 70(9): 2087-90, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22425414

RESUMO

A commercial solution of (65)Zn was standardized by the sum peak-method using a planar HPGe detector. The activity results were compared with measurements made with a well type 4πγ ionization chamber, which is traceable to BIPM.RI (II)-K2.Zn-65 key-comparison performed in 2002. The sum-peak value was 42.79 kBq/g and the ionization chamber value was 42.74 kBq/g both at the reference date. The uncertainty obtained in the sum peak standardization was 0.25% (k=1), and in the ionization chamber was 0.85% (k=1). The results showed that sum-peak method can be used in (65)Zn standardization and this method is easier, simpler and more practical than others methods.


Assuntos
Algoritmos , Radioisótopos/análise , Radioisótopos/normas , Radiometria/instrumentação , Radiometria/normas , Radioisótopos de Zinco/análise , Radioisótopos de Zinco/normas , Meia-Vida , Internacionalidade , Doses de Radiação , Radioisótopos/química , Padrões de Referência , Valores de Referência , Semicondutores , Radioisótopos de Zinco/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA