Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Artif Organs ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38989991

RESUMO

BACKGROUND: Significant tricuspid regurgitation (TR) is a predictor of right heart failure (RHF) and increased mortality following left ventricular assist device (LVAD) implantation, however the benefit of tricuspid valve surgery (TVS) at the time of LVAD implantation remains unclear. This study compares early and late mortality and RHF outcomes in patients with significant TR undergoing LVAD implantation with and without concomitant TVS. METHODS: A systematic search of four electronic databases was conducted for studies comparing patients with moderate or severe TR undergoing LVAD implantation with or without concomitant TVS. Meta-analysis was performed for primary outcomes of early and late mortality and RHF. Secondary outcomes included rate of stroke, renal failure, hospital and ICU length of stay. An overall survival curve was constructed using aggregated, reconstructed individual patient data from Kaplan-Meier (KM) curves. RESULTS: Nine studies included 575 patients that underwent isolated LVAD and 308 patients whom received concomitant TVS. Both groups had similar rates of severe TR (46.5% vs. 45.6%). There was no significant difference seen in risk of early mortality (RR 0.90; 95% CI, 0.57-1.42; p = 0.64; I2 = 0%) or early RHF (RR 0.82; 95% CI, 0.66-1.19; p = 0.41; I2 = 57) and late outcomes remained comparable between both groups. The aggregated KM curve showed isolated LVAD to be associated with overall increased survival (HR 1.42; 95% CI, 1.05-1.93; p = 0.023). CONCLUSIONS: Undergoing concomitant TVS did not display increased benefit in terms of early or late mortality and RHF in patients with preoperative significant TR. Further data to evaluate the benefit of concomitant TVS stratified by TR severity or by other predictors of RHF will be beneficial.

2.
Artif Organs ; 47(6): 1018-1028, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36582131

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) implantation via thoracotomy has many potential advantages compared to conventional sternotomy, including improved inflow cannula (IFC) positioning. We compared the difference in IFC angles, postoperative, and long-term outcomes for patients with LVADs implanted via thoracotomy and sternotomy. METHODS: A single-center, retrospective analysis of 14 patients who underwent thoracotomy implantation was performed and matched with 28 patients who underwent sternotomy LVAD implantations for a total of 42 patients. Inclusion required a minimum LVAD support duration of 30 days and excluded concomitant procedures. A postoperative CT-chest was used to measure the angle the between the IFC and mitral valve in two-dimensions and results were compared with three-dimensional reconstruction using the same CT chest. Outcome data were extracted from medical records. RESULTS: There was no significant difference in gender, INTERMACS score, BMI, or age between the two groups. Median cardiopulmonary bypass time was longer in the thoracotomy group compared to the sternotomy group, 107 min (86-122) versus 76 min (56-93), p < 0.01. 3D reconstructions revealed less deviation of the IFC away from the mitral valve in devices implanted via thoracotomy compared to sternotomy, median (IQR) angle 16.3° (13.9°-21.0°) versus 23.2° (17.9°-26.4°), p < 0.01. Rates of pump thrombosis, stroke, and gastrointestinal bleeding were not significantly different. CONCLUSIONS: Devices implanted via thoracotomy demonstrated less deviation away from mitral valve. However, there was no difference in morbidity between the two approaches. 3D reconstruction of the heart is an innovative technique to measure angulation and is clinically advantageous when compared to 2D imaging.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Esternotomia , Toracotomia/efeitos adversos , Cânula , Estudos Retrospectivos , Imageamento Tridimensional , Insuficiência Cardíaca/cirurgia
3.
J Paediatr Child Health ; 59(8): 937-942, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37144911

RESUMO

AIM: We describe the experience of a new paediatric heart transplant (HT) centre in Australia. New South Wales offers quaternary paediatric cardiac services including comprehensive care pre- and post-HT; however, perioperative HT care has previously occurred at the national paediatric centre or in adult centres. Internationally, perioperative HT care is highly protocol-driven and a majority of HT occurs in low volume centres. Establishing a low volume paediatric HT centre in New South Wales offers potential for quality HT care close to home. METHODS: Retrospective review of programme data for the first 12 months was undertaken. Patient selection was audited against the programme's intended initiation criteria. Longitudinal patient data on outcomes and complications were obtained from patient medical records. RESULTS: The programme's initial phase offered HT to children with non-congenital heart disease and no requirement for durable mechanical circulatory support. Eight patients met criteria for HT referral. Three underwent interstate transfer to the national paediatric centre. Five children (13-15 years, weight 36-85 kg) underwent HT in the new programme. Individual predicted 90-day mortality was 1.3-11.6%, with increased risk for recipients transplanted from veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and with restrictive/hypertrophic cardiomyopathies. Survival at 90 days and for duration of follow-up is 100%. Observed programme benefits include mitigation of family dislocation and improved continuity of care within a family-centred programme. CONCLUSION: Audit of the first 12 months' activity of a second paediatric HT centre in Australia demonstrates adherence to proposed patient selection criteria and excellent 90-day patient outcomes. The programme demonstrates feasibility of care close to home, providing continuity for all patients including those requiring increased rehabilitation and psychosocial support post-transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Adulto , Humanos , Criança , Austrália , Estudos Retrospectivos , New South Wales
4.
Perfusion ; 38(8): 1568-1576, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36036658

RESUMO

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) flows are titrated to achieve adequate perfusion while attempting to ideally maintain arterial pulse pressure (PP). We assessed risk in patients with low PP defined as <10 mmHg within the first 2 days of support. METHODS: Demographics, haemodynamics, echocardiographic and radiological findings were recorded retrospectively in cases conducted between 2014 and 2016. Outcomes were hospital mortality, requirement for renal replacement therapy (RRT) and severe pulmonary oedema (PO). RESULTS: Of 101 patients, 66.3% were male, mean age was 56 (range 18-71 years), mean duration of support was 6.3 days ± 4.1 days, 37.6% died prior to hospital discharge, 39.6% needed RRT and 11.9% had severe PO. Areas under the receiver operating curves of PP at 48 h for hospital mortality, RRT and severe PO were (respectively): 0.69 (95% CI 0.58-0.80, p = .001), 0.64 (95% CI 0.50-0.77, p = .044), 0.69 (95% CI 0.55-0.82, p = .009). The odds ratio for mortality, RRT, severe PO for those with low PP were (respectively) 2.8 (95% CI 1.01-7.5, p = .04), 3.1 (95% CI 1.11-8.40, p = .026), 7.6 (95% CI 2.06-27.89, p = .001). Central venous pressure, mean arterial pressure were not predictive. CONCLUSION: PP during the first 2 days of support is predictive of clinically important outcomes in patients supported with VA-ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Nefropatias , Edema Pulmonar , Humanos , Masculino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Sanguínea , Oxigenação por Membrana Extracorpórea/efeitos adversos , Edema Pulmonar/etiologia , Edema Pulmonar/terapia , Estudos Retrospectivos , Alta do Paciente , Diálise Renal , Hospitais
5.
Catheter Cardiovasc Interv ; 100(7): 1252-1260, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36321629

RESUMO

OBJECTIVES: To determine safety and feasibility of ex-situ coronary angiography. BACKGROUND: To cater for the perpetually growing demand for heart donors, interest in donation following circulatory death (DCD) has been rekindled. Further pursuit of donor pool expansion has led to eligibility extension to "marginal" donors who are at higher risk of coronary artery disease (CAD). Excluding CAD in potentially eligible DCD donors, for whom ante-mortem angiography is commonly not permitted, is therefore challenging. Ex-situ coronary angiography serves as an ethical and feasible diagnostic tool to assess for preclusive CAD. METHODS: We undertook a systematic review of the published literature and institutional retrospective review of case experience with ex-situ coronary angiography of donor hearts, supported by a portable organ care system. RESULTS: Combined literature and institutional case review yielded nine total cases of ex-situ coronary angiography of donor human hearts plus one experimental porcine model. Of the eight cases of ex-situ coronary angiography performed at our institute, all were conducted without complication or injury to the allograft. Two thirds of reported human cases have proceeded to successful transplantation. CONCLUSIONS: Diagnostic coronary angiography of the ex-situ beating donor heart is safe, feasible, and demonstrates novel clinical utility in mitigating subsequent transplantation of unsuitable allografts. In the setting of suspected coronary atherosclerosis of the donor heart, which may preclude favorable transplantation outcomes, ex-situ coronary angiography should be considered at eligible transplant centers.


Assuntos
Transplante de Coração , Doadores de Tecidos , Humanos , Suínos , Animais , Transplante de Coração/efeitos adversos , Angiografia Coronária/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos
6.
Artif Organs ; 46(1): 50-56, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34580890

RESUMO

BACKGROUND: BiVACOR is a novel total artificial heart (TAH) utilizing a single centrifugal magnetically levitated rotor with the ability to modulate pulsatile flow. The device has been successfully tested in a bovine model. We undertook a multicenter anatomical and virtual fitting study of the BiVACOR in patients undergoing heart transplantation. METHODS: 10 patients were recruited across two heart transplant centers. A sterilized 1:1 titanium model of the device was inserted into the patient's chest post heart explant, prior to implantation of the donor heart. Measurements were recorded in situ. The device was then removed. Following this, retrospective 3D reconstructions were created from computed tomography chest scans to simulate a virtual fitting. RESULTS: Mean age was 53 years (range 38-67). Mean BMI was 28 (range 20-37). Heart failure etiology was varied-with ischemic cardiomyopathy being the most common. Mean spine-to-sternum distance at the tenth thoracic vertebrae (T10) was 14 cm (range 11-18). Mean aorta to aortic Port distance was 0.2 cm (range 0-0.5). Mean pulmonary artery to pulmonary artery port distance was 4.2 cm (range 1-7). The device fitted suitably in all patients without gross distortion to the geometry between native vessel/chamber and port. CONCLUSIONS: This study described the anatomical and virtual fitting of the BiVACOR TAH. The device fit well within the chest cavities of all 10 patients, who represented a variety of body morphologies and heart failure etiology.


Assuntos
Coração Artificial , Coração/anatomia & histologia , Adulto , Idoso , Feminino , Coração/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Tórax/anatomia & histologia , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X
7.
Curr Cardiol Rep ; 24(12): 1973-1981, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36272050

RESUMO

PURPOSE OF REVIEW: To highlight the current global experience with DCD heart transplantation and explore the evolution of, and compare preservation strategies; examine early clinical outcomes, and discuss the growing use of DCD donors as a new frontier in heart transplantation. RECENT FINDINGS: The two strategies of DCD heart preservation include NMP using the OCS Heart and TA-NRP followed by either: NMP or CSS. Better understanding the limits of cold ischaemia following TA-NRP will aid in distant procurement. Asystolic warm ischaemia plays an important role in determining immediate post-operative graft function and potential need for mechanical support. Large volume DCD heart transplant units show no difference in survival between DCD and DBD donor heart transplants. In a previously non-utilised source of donor hearts, often viewed as an "unknown frontier" in heart transplantation, DCD hearts are a suitable alternative to brain-dead donor hearts and are likely to remain a permanent part of the heart transplantation landscape. Global uptake is currently increasing, and as understanding of preservation strategies and tolerable ischaemic times improve, utilisation of DCD hearts will continue to grow.


Assuntos
Transplante de Coração , Humanos , Doadores de Tecidos , Coração , Perfusão
8.
Perfusion ; 37(2): 152-161, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33482711

RESUMO

BACKGROUND: Vasoplegia has been shown to be associated with increased morbidity and mortality in patients undergoing cardiac surgery. It has been previously stated that low pulsatile states as seen with current left ventricular assist devices (LVADs) may contribute to vasoplegia post LVAD-explant and heart transplant. We sought to examine the literature regarding vasoplegia in the post-operative setting for patients undergoing LVAD explant and heart transplant. METHOD: A literature review was conducted to firstly define vasoplegia in the setting of LVAD patients, and secondly to better understand the relationship between vasoplegia and LVAD explantation in the postoperative heart transplant patient cohort. A keyword search of 'vasoplegia' OR 'vasoplegic' AND 'transplant' was used. Search engines used were PubMed, Cochrane Library, ClinicalTrials.gov, Ovid, Scopus and grey literature. RESULTS: 17 studies met the selection criteria for review. Three key themes emerged from the literature. Firstly, there is limited consensus regarding the definition of vasoplegia. Secondly, patients with LVADs experienced higher rates of vasoplegia following heart transplant than their counterparts and thirdly, increased cardiopulmonary bypass time was associated with a higher rate of vasoplegia. CONCLUSION: Vasoplegia is not clearly defined in the literature as it pertains to the LVAD patient cohort. Patients bridged with LVADs appear to have higher rates of vasoplegia, however the aetiology of this is unclear and may be associated with continuous flow physiology or prolonged cardiopulmonary bypass time. A universal definition will aid in risk stratification, early recognition and management.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Vasoplegia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Vasoplegia/complicações
9.
Catheter Cardiovasc Interv ; 95(1): E37-E39, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30919551

RESUMO

A 73-year-old man with severe, symptomatic secondary mitral regurgitation (MR) underwent successful transcatheter mitral valve replacement using the Tendyne™ mitral valve system. The device was deployed from the left ventricular (LV) apex and secured in position by a tether attached to an epicardial pad. Three days postoperatively, the patient developed hemolytic anemia and a paravalvular leak (PVL) associated with indentation of the LV apex. Adjustment of the tether tension and placement of an epicardial disc under the pad resulted in reduction in the PVL, and resolution of the hemolytic anemia.


Assuntos
Migração de Corpo Estranho/cirurgia , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Anemia Hemolítica/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/fisiopatologia , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Reoperação , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Artif Organs ; 43(5): 458-466, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30375659

RESUMO

Continuous flow left ventricular assist devices (cfLVADS) result in a significant reduction in aortic valve (AV) opening, which has been associated with several complications. Reliable monitoring of AV opening is needed to determine whether pump speed adjustment may be able to minimize adverse outcomes. We assessed AV status continuously by echocardiography for 4 minutes in 3 states in 18 HeartWare HVAD patients: 2 minutes at rest, and 1 minute each following Valsalva maneuver and supine leg-raising. Using a previously described algorithm, beat-to-beat AV status was compared with the area under the curve of the normalized power spectral density analysis (PSD-AUC) for the corresponding beats of the pump speed waveform. Five thousand five hundred twenty-seven beats were analyzed. AV opening varied between 0% and 100% for the cohort with the median AV opening frequency 21.5%, and median duration of opening of 124 msec (range 0-279). The receiver operating characteristic (ROC) curve area for AV opening by the PSD-AUC algorithm was 0.95 (P < 0.0001). A PSD-AUC cut-off of 0.82 distinguished between an open and closed AV with 86% sensitivity and 93% specificity. Accuracy was similar in regular cardiac rhythm, atrial fibrillation or with frequent ventricular ectopic beats. Valsalva maneuver and leg-raising had no impact on accuracy. The PSD-AUC was strongly predictive of AV opening duration (P < 0.0001). We found that AV status and opening duration can be determined with high accuracy on a beat-to-beat basis irrespective of cardiac rhythm and with low level exercise and changes in filling.


Assuntos
Valva Aórtica/fisiopatologia , Coração Auxiliar/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC
11.
Intern Med J ; 47(9): 1068-1071, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28891183

RESUMO

A 63-year-old man with an ischaemic cardiomyopathy, supported by the HeartWare left ventricular assist device (LVAD), presented with ventricular tachycardia and inferior ST-elevation myocardial infarction (STEMI) with associated acute right ventricular (RV) dysfunction. He underwent primary percutaneous coronary intervention with balloon angioplasty and placement of three drug-eluting stents in the proximal-to-mid right coronary artery. Post-procedure, ventricular arrhythmias abated, RV systolic dysfunction resolved and RV size normalised. Percutaneous coronary intervention (PCI) facilitated by the use of miniaturised percutaneous LVAD has become an increasingly available treatment option for high-risk patients. PCI in patients on established full mechanical circulatory support is not a common occurrence. Indeed, to our knowledge, this is the first case of primary percutaneous coronary intervention on an LVAD-supported heart reported in the medical literature. The case raises several specific issues that are of peculiar interest to clinicians involved in the care of patients supported by mechanical assist devices who experience an acute coronary syndrome requiring emergent revascularisation.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Coração Auxiliar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
Lancet ; 385(9987): 2585-91, 2015 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-25888085

RESUMO

BACKGROUND: Orthotopic heart transplantation is the gold-standard long-term treatment for medically refractive end-stage heart failure. However, suitable cardiac donors are scarce. Although donation after circulatory death has been used for kidney, liver, and lung transplantation, it is not used for heart transplantation. We report a case series of heart transplantations from donors after circulatory death. METHODS: The recipients were patients at St Vincent's Hospital, Sydney, Australia. They received Maastricht category III controlled hearts donated after circulatory death from people younger than 40 years and with a maximum warm ischaemic time of 30 min. We retrieved four hearts through initial myocardial protection with supplemented cardioplegia and transferred to an Organ Care System (Transmedics) for preservation, resuscitation, and transportation to the recipient hospital. FINDINGS: Three recipients (two men, one woman; mean age 52 years) with low transpulmonary gradients (<8 mm Hg) and without previous cardiac surgery received the transplants. Donor heart warm ischaemic times were 28 min, 25 min, and 22 min, with ex-vivo Organ Care System perfusion times of 257 min, 260 min, and 245 min. Arteriovenous lactate values at the start of perfusion were 8·3-8·1 mmol/L for patient 1, 6·79-6·48 mmol/L for patient 2, and 7·6-7·4 mmol/L for patient 3. End of perfusion lactate values were 3·6-3·6 mmol/L, 2·8-2·3 mmol/L, and 2·69-2·54 mmol/L, respectively, showing favourable lactate uptake. Two patients needed temporary mechanical support. All three recipients had normal cardiac function within a week of transplantation and are making a good recovery at 176, 91, and 77 days after transplantation. INTERPRETATION: Strict limitations on donor eligibility, optimised myocardial protection, and use of a portable ex-vivo organ perfusion platform can enable successful, distantly procured orthotopic transplantation of hearts donated after circulatory death. FUNDING: NHMRC, John T Reid Charitable Trust, EVOS Trust Fund, Harry Windsor Trust Fund.


Assuntos
Displasia Arritmogênica Ventricular Direita/terapia , Cardiomiopatia Dilatada/terapia , Transplante de Coração/métodos , Miocardite/terapia , Preservação de Órgãos/métodos , Doadores de Tecidos/classificação , Obtenção de Tecidos e Órgãos/métodos , Adulto , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Biópsia , Cardiomiopatia Dilatada/fisiopatologia , Feminino , Parada Cardíaca Induzida , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Choque/patologia , Resultado do Tratamento , Viroses/terapia , Isquemia Quente
13.
Catheter Cardiovasc Interv ; 87(7): E275-81, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26508564

RESUMO

OBJECTIVES: The objective of this study is to describe and compare the use of the MitraClip therapy in mitral regurgitation (MR) patients with degenerative MR (DMR) and functional MR (FMR). INTRODUCTION: Percutaneous edge-to-edge repair of severe MR using the MitraClip device is approved for use in the USA for high risk DMR while European guidelines include its use in FMR patients as well. METHODS: The MitraClip in the Asia-Pacific Registry (MARS) is a multicenter retrospective registry, involving eight sites in five Asia-Pacific countries. Clinical and echocardiographic characteristics, procedural outcomes and 1-month outcomes [death and major adverse events (MAE)] were compared between FMR and DMR patients treated with the MitraClip. RESULTS: A total of 163 patients were included from 2011 to 2014. The acute procedural success rates for FMR (95.5%, n = 84) and DMR (92%, n = 69) were similar (P = 0.515). 45% of FMR had ≥2 clips inserted compared to 60% of those with DMR (P = 0.064).The 30-day mortality rate for FMR and DMR was similar at 4.5% and 6.7% respectively (P = 0.555). The 30-day MAE rate was 9.2% for FMR and 14.7% for DMR (P = 0.281). Both FMR and DMR patients had significant improvements in the severity of MR and NYHA class after 30 days. There was a significantly greater reduction in left ventricular end-diastolic diameter (P = 0.002) and end systolic diameter (P = 0.017) in DMR than in FMR. CONCLUSIONS: The MitraClip therapy is a safe and efficacious treatment option for both FMR and DMR. Although, there is a significantly greater reduction in LV volumes in DMR, patients in both groups report clinical benefit with improvement in functional class. © 2015 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Ásia , Austrália , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
14.
Pacing Clin Electrophysiol ; 38(8): 925-33, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25940215

RESUMO

BACKGROUND: Both implantable cardioverter defibrillators (ICDs) and left ventricular assist devices (LVADs) have a positive impact on survival in the heart failure population. We sought to determine whether these positive effects on survival are additive or whether LVAD therapy supersedes ICD therapy. METHOD: We analyzed survival data of patients implanted with nonpulsatile LVADs between October 2004 and March 2013. Survival in patients with ICDs (n = 64) was compared to those without ICDs (n = 36). Patients exited the study at the time of heart transplantation or death. RESULTS: A total of 100 patients underwent LVAD implantation during this time. Patients had a mean follow-up time of 364 ± 295 days. Death occurred in 15 (38%) patients in the no ICD group versus 18 (30%) in the ICD group. Univariate analysis demonstrated a marginal early survival benefit at up to 1 year post-LVAD implant in the ICD cohort; however, at time points greater than 1 year there was no statistically significant benefit in ICD therapy in LVAD patients (P = 0.56). Multivariate analysis did not show any significant predictor of survival. There were no patients who died of sudden cardiac death. There was no significant difference in the time to heart transplantation (443 days ± 251 no ICD vs 372 days ± 277 ICD, P = 0.37). CONCLUSION: The benefit of ICD therapy in the setting of continuous flow LVAD therapy is uncertain. Although prolonged ventricular arrhythmias (VAs) may potentially impact on patient survival, LVAD therapy is beneficial in prevention of sudden cardiac death due to VAs.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida
15.
J Cardiothorac Vasc Anesth ; 29(2): 288-96, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25655210

RESUMO

OBJECTIVES: To characterize the longitudinal hemostatic profile during adult ECMO using point-of-care tests (POCT) for coagulation and to compare these parameters to standard laboratory tests. In addition, the clinicians' responses during bleeding episodes using available information were compared to a POCT-based response. DESIGN: Prospective observational cohort study. SETTING: ECMO-referral center in a university teaching hospital. PARTICIPANTS: Ten critically ill adult ECMO patients. INTERVENTIONS: Daily laboratory coagulation profile, transfusion history and near-daily thromboelastometry (ROTEM®) and platelet aggregometry (Multiplate®). MAIN RESULTS: Six male and four female patients, seven with VA- and three with VV-ECMO were studied over 110 days. Seventy-five thromboelastometry (TEM) and 36 platelet aggregometry (MEA) results were analyzed. A majority of TEM values were within the normal range, except for FIBTEM (majority high), which remained consistent over long (>5 days) ECMO runs. In MEA there were low values, particularly in the adenosine diphosphate- and ristocetin-induced assay, implying possibly a vWF-factor or GpIb-receptor defect. There was correlation between laboratory and POCT as well as good correlation between the clot firmness after 10 minutes (A10) and the maximum clot firmness in ROTEM, suggesting that reliable information can be obtained within 15 minutes. Twenty-two bleeding episodes were observed in five patients. When comparing the clinicians' response to a transfusion algorithm based on POCT, there was a concordance in less than 20% of episodes. CONCLUSIONS: POCT for coagulation can provide specific, reliable, and timely information during bleeding episodes and the use of targeted therapy algorithms could improve outcomes and reduce costs.


Assuntos
Transtornos da Coagulação Sanguínea/diagnóstico , Transtornos da Coagulação Sanguínea/etiologia , Plaquetas , Oxigenação por Membrana Extracorpórea/efeitos adversos , Sistemas Automatizados de Assistência Junto ao Leito , Tromboelastografia/estatística & dados numéricos , Adulto , Transtornos da Coagulação Sanguínea/sangue , Testes de Coagulação Sanguínea/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas/estatística & dados numéricos , Estudos Prospectivos
16.
Artif Organs ; 38(12): 1029-34, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24660889

RESUMO

It is important to accurately monitor residual cardiac function in patients under long-term continuous-flow left ventricular assist device (cfLVAD) support. Two new measures of left ventricular (LV) chamber contractility in the cfLVAD-unloaded ventricle include IQ, a regression coefficient between maximum flow acceleration and flow pulsatility at different pump speeds; and K, a logarithmic relationship between volumes moved in systole and diastole. We sought to optimize these indices. We also propose RIQ, a ratio between maximum flow acceleration and flow pulsatility at baseline pump speed, as an alternative to IQ. Eleven patients (mean age 49 ± 11 years) were studied. The K index was derived at baseline pump speed by defining systolic and diastolic onset as time points at which maximum and minimum volumes move through the pump. IQ across the full range of pump speeds was markedly different between patients. It was unreliable in three patients with underlying atrial fibrillation (coefficient of determination R(2) range: 0.38-0.74) and also when calculated without pump speed manipulation (R(2) range: 0.01-0.74). The K index was within physiological ranges, but poorly correlated to both IQ (P = 0.42) and RIQ (P = 0.92). In four patients there was excellent correspondence between RIQ and IQ, while four other patients showed a poor relationship between these indices. As RIQ does not require pump speed changes, it may be a more clinically appropriate measure. Further studies are required to determine the validity of these indices.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Contração Muscular/fisiologia , Fluxo Pulsátil/fisiologia , Função Ventricular Esquerda/fisiologia , Adulto , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
17.
Heart Lung Circ ; 23(9): 841-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24751512

RESUMO

BACKGROUND: With improved life expectancy more octogenarians now present with aortic valve disease. Cardiac surgery in this group of patients has previously been considered high risk due to co-morbidities and challenges of rehabilitation. This study seeks to challenge the concept of octogenarian cardiac surgery "unsuitability" by analysing operative outcomes and long term survival following aortic valve replacement. METHODS: Eighty-seven consecutive patients undergoing aortic valve replacement between 2000 and 2009 at St Vincent's Hospital were retrospectively identified. Statistical analysis was performed using SPSS (version 15 and 19). RESULTS: The average age was 82.7 ± 2.4 years. The mean logistic EuroSCORE was 18.86 ± 14.11. Post-operatively, four patients required insertion of a permanent pacemaker (4.6%) and five patients had a myocardial infarction (5.8%). In-hospital mortality was 3.4%. Follow-up was 93.1% complete. One-year survival was 92.9%, three-year survival was 86.7% and five-year survival was 75.0%. At follow-up 98.1% of patients were New York Heart Association (NYHA) Class I or II. CONCLUSIONS: Results were excellent despite reasonable co-morbidities and Euroscore risk. Survival was impressive and the NYHA class reflected the success of the surgery in relieving the pathological aortic valve process. Patient age should not be the primary exclusion for cardiac surgery for aortic valve disease.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso de 80 Anos ou mais , Cuidados Críticos , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Esternotomia/mortalidade , Taxa de Sobrevida
18.
Heart Lung Circ ; 23(8): 703-10, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24709393

RESUMO

BACKGROUND: Improved survival of heart transplant (HTx) recipients and increased acceptance of higher risk donors allows development of late pathology. However, there are few data to guide surgical options. We evaluated short-term outcomes and mortality to guide pre-operative assessment, planning, and post-operative care. METHODS: Single centre, retrospective review of 912 patients who underwent HTx from February 1984 - June 2012, identified 22 patients who underwent subsequent cardiac surgery. Data are presented as median (IQR). RESULTS: Indications for surgery were coronary allograft vasculopathy (CAV) (n=10), valvular disease (n=6), infection (n=3), ascending aortic aneurysm (n=1), and constrictive pericarditis (n=2). There was one intraoperative death (myocardial infarction). Hospital stay was 10 (8-21) days. Four patients (18%) returned to theatre for complications. After cardiac surgery, survival at one, five and 10 years was 91±6%, 79±10% and 59±15% with a follow-up of 4.6 (1.7-10.2) years. High pre-operative creatinine was a univariate risk factor for mortality, HR=1.028, (95%CI 1.00-1.056; p=0.05). A time dependent Cox proportional hazards model of the risk of cardiac surgery post-HTx showed no significant hazard; HR=0.87 (95%CI 0.37-2.00; p=0.74). CONCLUSIONS: Our experience shows cardiac surgery post-HTx is associated with low mortality, and confirms that cardiac surgery is appropriate for selected HTx recipients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias , Transplante de Coração , Adulto , Intervalo Livre de Doença , Feminino , Seguimentos , Cardiopatias/etiologia , Cardiopatias/mortalidade , Cardiopatias/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida
19.
Heart Lung Circ ; 23(10): 963-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24973864

RESUMO

BACKGROUND: New generation continuous-flow left ventricular assist devices (LVADs) utilise centrifugal pumps. Data concerning their effect on patient haemodynamics, ventricular function and tissue perfusion is limited. We aimed to document these parameters following HeartWare centrifugal continuous-flow LVAD (HVAD) implantation and to assess the impact of post-operative right heart failure (RHF). METHODS: We reviewed 53 consecutive patients (mean age 49.5 ± 14.1 yrs) with HVAD implanted in the left ventricle, at St. Vincent's Hospital, Sydney, between January 2007 and August 2012. Available paired right heart catheterisation (n=35) and echocardiography (n=39) data was reviewed to assess response of invasive haemodynamics and ventricular function to LVAD support. RESULTS: A total of 28 patients (53%) were implanted from interim mechanical circulatory support. Seventeen patients (32%) required short-term post-implant veno-pulmonary artery extracorporeal membrane oxygenation. At 100 ± 61 days post-implant, mean pulmonary artery pressure and mean pulmonary capillary wedge pressure decreased from 38.8 ± 7.7 to 22.9 ± 7.7 mmHg and 28.3 ± 6.4 to 13.4 ± 5.4 mmHg respectively (p<0.001). LV end diastolic diameter decreased from 71.3 ± 12.7 to 61.1 ± 13.7 mm and LV end-systolic diameter from 62.7 ± 12.3 to 53.9 ± 14.4mm (p<0.001). Aortic regurgitation remained trivial. Serum sodium increased from 133.3 ± 5.7 to 139.3 ± 2.8 mmol/L and creatinine decreased from 109.1 ± 42.5 to 74.3 ± 26.2 µmol/L (p<0.001). Across the entire cohort, the six-month survival/transplant rate was significantly lower for RHF patients (72.2%, n=18) compared to those without (96.9%, n=35, p=0.01). CONCLUSIONS: HVAD support improves haemodynamics, LV dimensions and renal function. Following implantation with a centrifugal continuous-flow LVAD, RHF remains a significant risk with a tendency to worse outcomes in the short to medium term.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Hemodinâmica , Disfunção Ventricular Esquerda/cirurgia , Adulto , Pressão Arterial , Cateterismo Cardíaco , Creatinina/sangue , Ecocardiografia , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pressão Propulsora Pulmonar , Sódio/sangue , Taxa de Sobrevida , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/fisiopatologia
20.
Transplantation ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39020464

RESUMO

BACKGROUND: Coronary allograft vasculopathy (CAV) remains a significant cause of morbidity and mortality after heart transplantation. The use of aspirin for CAV prophylaxis has recently garnered interest as a possible therapeutic adjunct in this setting. METHODS: This 2-center retrospective cohort study included 372 patients who underwent heart transplantation between January 2009 and March 2018 and were stratified according to the commencement of aspirin during their index transplant admission. The primary outcome was the development of moderate or severe CAV (International Society for Heart and Lung Transplantation grade ≥2) at surveillance coronary angiography. Secondary endpoints included mortality at follow-up. RESULTS: There were no differences in age, sex, and cause of heart failure. In the early aspirin group, the preponderant risk factors included use of ventricular assist devices, pretransplant smoking, and mild or moderate rejection. Multivariable analyses to assess for independent predictors of CAV development and mortality demonstrated that aspirin was associated with reduced mortality (adjusted hazard ratio = 0.19; 95% confidence interval, 0.08-0.47, P < 0.01) and a trend toward a protective effect against the development of moderate or severe CAV (adjusted hazard ratio = 0.24; 95% confidence interval, 0.54-1.19; P = 0.08). CONCLUSIONS: In this retrospective risk-adjusted 2-center cohort study, early aspirin administration was associated with reduced risk of death and a trend toward a protective effect against CAV development. These findings warrant validation in prospective randomized trials.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA