RESUMO
PURPOSE: To compare SF 6 relative with C 2 F 6 in the anatomical and functional outcomes following pars plana vitrectomy for uncomplicated primary pseudophakic rhegmatogenous retinal detachment with inferior causative breaks. METHODS: This is a retrospective, comparative study on eyes with pseudophakic rhegmatogenous retinal detachment with inferior causative breaks that had small-gauge pars plana vitrectomy repair using SF 6 and C 2 F 6 tamponade between 2011 and 2020 at a tertiary centre in the United Kingdom. Primary outcome was single surgery anatomical success, and the secondary outcome was best-corrected visual acuity. Propensity score matching, using preoperative findings as covariates to account for relevant confounders, was performed. RESULTS: From 162 pseudophakic rhegmatogenous retinal detachment eyes with inferior causative breaks, the median (interquartile range) follow-up was 82 (52-182) days. The single surgery anatomical success was 156 (96.3%) overall: 47 of 47 (100.0%) and 109 of 115 (94.8%) in the SF 6 and C 2 F 6 groups, respectively ( P = 0.182). Relative to the SF 6 group, the C 2 F 6 group had a higher mean number of tears (SF 6 : 3.1[2.0], C 2 F 6 : 4.5[2.7], P = 0.002) and greater retinal detachment extent (SF 6 : 5.3[2.9], C 2 F 6 : 6.2[2.6] clock hours, P = 0.025). Following propensity score matching analysis, 80 eyes were matched with 40 in each group to homogenize preoperative factors. No significant difference was found in single surgery anatomical success and best-corrected visual acuity between the groups following propensity score matching. CONCLUSION: Primary pars plana vitrectomy with gas tamponade leads to a high single surgery anatomical success rate in uncomplicated pseudophakic rhegmatogenous retinal detachment with inferior causative breaks with no additional benefit associated with long-acting tamponade when comparing C 2 F 6 with SF 6 .
Assuntos
Tamponamento Interno , Fluorocarbonos , Pseudofacia , Descolamento Retiniano , Hexafluoreto de Enxofre , Acuidade Visual , Vitrectomia , Humanos , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Vitrectomia/métodos , Estudos Retrospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Pseudofacia/complicações , Tamponamento Interno/métodos , Idoso , Hexafluoreto de Enxofre/administração & dosagem , Pessoa de Meia-Idade , Fluorocarbonos/administração & dosagem , Perfurações Retinianas/cirurgia , Perfurações Retinianas/etiologia , Perfurações Retinianas/diagnóstico , Seguimentos , Resultado do TratamentoRESUMO
PURPOSE: To investigate the effect of isovolumetric and expansile gas tamponade concentrations on single surgery anatomical success (SSAS) and day 1 intraocular pressure (IOPD1) following pars plana vitrectomy (PPV) for mild-moderate complexity primary pseudophakic rhegmatogenous retinal detachment (PRD). METHODS: We conducted a single-centre retrospective continuous and comparative study on eyes that had undergone small-gauge PPV using isovolumetric versus expansile gas for PRD repair between 2011 and 2020 at a single tertiary vitreoretinal centre in UK. We performed propensity score matching (PSM) using preoperative findings as covariates to account for relevant confounders. Significant risk factors such as proliferative vitreoretinopathy C or giant retinal tears were excluded. RESULTS: From 456 eyes, PSM analysis matched 240 eyes with 120 in each group. The median (interquartile range) follow-up was 96 (59 to 218) days. The SSAS was 229/240 (95.8%) overall; 115/120 (95.8%) and 114/120 (95.0%) in isovolumetric and expansile groups, respectively (p = 1.000). Relative to the isovolumetric group, the expansile group had lower proportion of eyes with IOP ≤ 21 mmHg (odds ratio, 95% confidence interval, 0.40 [0.23-0.68], p < 0.001); but significantly higher number of eyes with IOP ≥ 22 mmHg (2.53 [1.48-4.34], p < 0.001), ≥ 25 mmHg (2.77 [1.43-5.33], p < 0.001), ≥ 30 mmHg (2.90 [1.28-6.58], p = 0.006) and ≥ 40 mmHg (p = 0.029, isovolumetric: 0 [0%] vs expansile group: 6 [5%]). There was only one case of hypotony (≤ 5 mmHg) 1/240 (0.4%) which occurred in the expansile group. CONCLUSIONS: Expansile gas concentration does not impact SSAS but is associated with significantly raised IOPD1 with no reduction in hypotony rates following PPV for primary PRD.
Assuntos
Descolamento Retiniano , Humanos , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/cirurgia , Descolamento Retiniano/etiologia , Pressão Intraocular , Estudos Retrospectivos , Acuidade Visual , Retina , Vitrectomia/efeitos adversos , Resultado do Tratamento , Complicações Pós-Operatórias/cirurgiaRESUMO
PURPOSE: To evaluate a sequential approach of pneumatic displacement followed by vitrectomy (pars plana vitrectomy) in failed cases to deal with submacular hemorrhage (SMH) of various etiologies. METHODS: Retrospective, nonrandomized interventional case series of consecutive patients with SMH of up to 2 weeks' duration, who were treated with a stepwise approach. Step 1 involved intravitreal injection of 0.3 mL 100% C3F8 and recombinant tissue plasminogen activator 50 µg/0.1 mL. If unsuccessful, a prompt pars plana vitrectomy with subretinal recombinant tissue plasminogen activator 50 µg/0.1 mL and 20% SF6 gas tamponade was performed as a second attempt to displace the SMH. RESULTS: Thirty-one patients with SMH underwent pneumatic displacement; 24 (77.4%) had a successful outcome without further intervention. The mean presenting visual acuity of the "successful cohort" was 1.34 logMAR (20/440 Snellen), improving to 0.83 logMAR (20/135 Snellen) 1 month after treatment. Five of the seven patients with failed pneumatic displacement underwent pars plana vitrectomy with subretinal recombinant tissue plasminogen activator at an average of 5 days poststep 1, with successful SMH displacement in 3 patients, giving an overall success of 87.1% for this treatment protocol. CONCLUSION: A sequential approach of expansile gas injection followed by prompt pars plana vitrectomy, aided by recombinant tissue plasminogen activator at both steps, is a coherent, logical pathway to treat SMH with high anatomical and functional success.
Assuntos
Protocolos Clínicos/normas , Angiofluoresceinografia/métodos , Fidelidade a Diretrizes/normas , Macula Lutea/diagnóstico por imagem , Hemorragia Retiniana/terapia , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tamponamento Interno/métodos , Feminino , Seguimentos , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Hemorragia Retiniana/diagnóstico , Hemorragia Retiniana/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido/epidemiologia , Acuidade Visual , Adulto JovemAssuntos
Coroideremia/fisiopatologia , Retina/fisiopatologia , Degeneração Retiniana/fisiopatologia , Adolescente , Adulto , Criança , Coroideremia/diagnóstico por imagem , Feminino , Humanos , Estudos Longitudinais , Masculino , Oftalmoscopia , Imagem Óptica , Degeneração Retiniana/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica , Adulto JovemRESUMO
PURPOSE: To investigate the anatomical and functional outcomes and specifically, the effect of 360-degree barrier-laser, in pars plana vitrectomy (PPV) for primary pseudophakic rhegmatogenous retinal detachment (PRD). METHODS: We conducted a single-centre retrospective, continuous and comparative study on eyes that had undergone PPV with focal-retinopexy (laser or cryotherapy) versus 360-laser for PRD repair between 2011-2020 at a single tertiary vitreoretinal centre in the UK. Primary outcomes were single surgery anatomical success (SSAS) rate and final postoperative visual acuity (VA). Multivariable regression covariates for primary re-detachment included age, gender, onset-of-detachment, pre-operative VA, ocular co-morbidities, macula-status, majority inferior (vs superior) PRD, number-of-tears and PRD extent (in clock-hours), 360-laser barricade, and perfluorocarbon liquid (PFCL) use. For VA gain, primary re-detachment was added as a covariate. RESULTS: We included 467 eyes with a mean follow-up of 388 (161) days. The SSAS was 444/467 (95.1%) overall, and 351/370 (94.9%) and 93/97 (95.9%) in focal-retinopexy and 360-laser groups, respectively (p = 0.798). Compared to the focal-retinopexy group, the 360-laser group had significantly worse post-operative VA but similar logMAR gain (p = 0.812). A multivariable binary logistic regression found that only PFCL use was linked with increased primary re-detachment (OR:5.32 [p = 0.048]) and 360-laser did not contribute to increased SSAS. A multivariable linear regression analysis showed that poor logMAR gain was significantly associated with better pre-operative logMAR, ocular co-morbidities, greater PRD extent, use of 360-laser and primary re-detachment. However, when excluding macula-off RD (n = 211), 360-laser was no longer significant (p = 0.088). CONCLUSIONS: Prophylactic 360-laser does not seem to impact on SSAS and functional outcomes following PPV for primary PRD.
Assuntos
Fluorocarbonos , Descolamento Retiniano , Humanos , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Vitrectomia , Estudos Retrospectivos , Retina , Lasers , Resultado do TratamentoRESUMO
Silicone oils (SO) are used as long-term intraocular tamponades and have an irreplaceable role in vitreoretinal surgery. They can, however, be associated with multiple and potentially severe complications, involving different ocular tissues, in particular retina and cornea. Recent advances in ophthalmic imaging have allowed the precise characterization of retinal and corneal microstructural changes, at a subclinical level. This detailed analysis of SO-related retinal and corneal changes has improved our understanding of their pathogenesis and offer the potential for optimized monitoring and management of patients with SO-filled eyes. This review aims to provide clinicians and ophthalmic scientists with an updated and comprehensive overview of the corneal and retinal changes associated with SO tamponade.
RESUMO
INTRODUCTION: The UK Government imposed a COVID19 lockdown (LD) restricting all but essential activities from 24th March 2020. Subsequently, there has been a significant reduction in casualty attendances nationwide including for ophthalmic emergencies. We aim to study the presentation of rhegmatogenous retinal detachments (RRD) and significant vitreous haemorrhage caused by posterior vitreous detachment (PVD-VH) in three tertiary centres covering most of the North West of England in the 6 weeks before and during the lockdown. METHODS: A retrospective multicenter non-randomised consecutive case series study was designed to collect information on all cases of RRD and PVD-VH requiring surgery presenting to the vitreoretinal departments of Manchester Royal Eye Hospital, East Lancashire NHS Foundation Trust and the Lancashire NHS Foundation Trust from 11th February to 4th May 2020. RESULTS: A total of 137 eyes of 137 patients were identified between the three centres of which 132 eyes were operated for RRD. Of these, 86 (64.7%) were operated pre-LD compared with 46 eyes (34.8%) during LD. Forty-five out of 86 eyes (52.3%) were macula-off pre-LD compared with 31 out of 46 eyes (67.3%) during LD (p = 0.06). There was lower proportion of non-PVD related RRD during LD (11 pre-LD to 1 during LD, p = 0.05). PVR was present in four cases during LD compared to 2 before (p = 0.19). CONCLUSION: There was a clinically significant reduction in the overall incidence of RRD in our centres with an increase in the proportion of macula-off and proliferative vitreoretinopathy during the LD period compared to a similar period before.
Assuntos
COVID-19 , Macula Lutea , Descolamento Retiniano , Controle de Doenças Transmissíveis , Humanos , Pandemias , Descolamento Retiniano/epidemiologia , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , SARS-CoV-2 , Reino Unido/epidemiologia , VitrectomiaRESUMO
OBJECTIVE: Pachymetry plays a crucial role in the diagnosis and management of glaucoma and corneal diseases. There have been several outbreaks of epidemic ocular infections in ophthalmology clinics worldwide with reports of viral, parasitic, and prion disease. Contact pachymetry is a possible vehicle of transmission due to its risk of contamination. We aim to identify the types of pachymetry used and methods employed for cleaning and disinfection in eye units throughout the United Kingdom. METHODS: A telephone survey was carried out, and a senior nurse or sister questioned based on the proforma created. A follow-up email was sent to units that did not respond with the questionnaire attached. RESULTS: Of 109 responses, 10 eye units were unaware of the device name and 4 were unaware of the cleaning method used. Overall, 69/105 (66%) were cleaned with some form of alcohol wipe between patients, 12/105 (11%) used presept solution to soak the pachymetry head mainly 5 to 10 minutes, with 2 units soaking for 20 to 30 minutes. Milton solution was used by 4 units (4%) (10 s to 10 min). Three used a hydrogen peroxide solution for 10 minutes (3%). Three (3%) used an alcohol solution. Fifteen (14%) units used some chlorine-based solution (actichlor/chloraprep) for 5 to 10 minutes. Two (2%) units combined an alcohol-based wipe with solution to soak afterward. CONCLUSIONS: There is a large variation in methods and duration of tip disinfection with only a few units following the Royal College of Ophthalmologists (RCOphth) guidelines on pachymeter disinfection. The majority of eye units use alcohol/chlorine-based wipes for cleaning the pachymetry heads which is against the current recommended guidelines. The average immersion time when solutions were used was 5 to 10 minutes.
Assuntos
Paquimetria Corneana/instrumentação , Desinfecção/métodos , Infecção Hospitalar/prevenção & controle , Desinfetantes/uso terapêutico , Desinfecção/normas , Contaminação de Equipamentos , Reutilização de Equipamento , Pesquisas sobre Atenção à Saúde , Humanos , Inquéritos e Questionários , Reino UnidoRESUMO
Gyrate atrophy is a rare autosomal recessive disorder caused by a mutation in the ornithine-δ-amino transferase gene. We present an interesting case of a 33-year-old woman who presented with increasing myopia, nyctalopia and failing vision. Examination revealed posterior subscapsular cataracts, narrowed peripheral visual fields and scalloped atrophic peripheral chorioretinal lesions. Blood investigations showed a raised plasma ornithine level at 917 µmol/L (normal range: 32-88 µmol/L) confirming the diagnosis of gyrate atrophy. The patient, despite not tolerating dietary treatment, had retained central vision over a follow-up period of 18 years. The electroretinogram, which normally diminishes with disease progression, was still nearly normal when last tested at 16 years follow-up. Genetic testing did not reveal any novel mutation that could account for this variation.
Assuntos
Eletrorretinografia , Atrofia Girata/diagnóstico por imagem , Campos Visuais/fisiologia , Adulto , Catarata/diagnóstico por imagem , Catarata/fisiopatologia , Extração de Catarata , Dieta com Restrição de Proteínas , Progressão da Doença , Feminino , Atrofia Girata/fisiopatologia , Atrofia Girata/cirurgia , Humanos , Implante de Lente Intraocular , Ornitina/sangue , Piridoxina/uso terapêutico , Degeneração Retiniana/diagnóstico por imagem , Degeneração Retiniana/fisiopatologia , Degeneração Retiniana/cirurgia , Resultado do Tratamento , Vitaminas/uso terapêuticoRESUMO
PURPOSE: To determine the prevalence of disposable tonometer versus non-disposable tonometer use in the UK and to determine methods of decontamination and frequency of replacement of prisms.A total of 137 ophthalmology departments were interviewed by telephone using a structured questionnaire. The main outcome measured were:types of tonometer prisms used in clinic (disposable, non-disposable and/or other)average disposable prisms used per clinic sessionaverage lifespan of non-disposable prismsprism preference by glaucoma and other teams within department.A cost and benefit analysis was then performed on the data acquired. RESULTS: One hundred and fifty-five departments were identified for the survey. Of these, 137 (88.3%) responded. Eighty-one departments (59.1%) used Tonosafe prisms alone, whereas 22 departments (16.1%) used Goldmann non-disposable prisms exclusively. Thirty-five departments (64%) on average have a change rate of 26.5% per year (range: 0-100, median: 20) attributed to damage, loss or theft. Sixteen departments (29%) reported that prisms were used until damaged or lost. Four departments (7%) were uncertain of their prism usage and could not provide further information. CONCLUSIONS: Majority of eye departments in the UK opt for disposable prisms. This survey shows the perceived cost-effectiveness of disposable prisms is overestimated when the true cost of disinfection and damage is taken into account. Significant cost savings coupled with the low risk of infectivity (if decontaminated properly) should prompt clinicians and ophthalmic departments worldwide to reconsider the use of non-disposable prisms.
RESUMO
We describe a novel technique that allows safe extraction of a buried Kuntscher nail during total hip arthroplasty in a patient with ipsilateral, symptomatic post-traumatic osteoarthritis of the hip. This method allows the surgeon to visualise the antegrade entry point of the nail allowing safe extraction of the device without compromising the result of the hip arthroplasty.