Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biochemistry ; 63(1): 9-18, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38011893

RESUMO

Here we report preliminary data demonstrating that some patients with myalgic encephalomyelitis/chronic fatiguesyndrome (ME/CFS) may have catalytic autoantibodies that cause the breakdown of myelin basic protein (MBP). We propose that these MBP-degradative antibodies are important to the pathophysiology of ME/CFS, particularly in the occurrence of white matter disease/demyelination. This is supported by magnetic resonance imagining studies that show these findings in patients with ME/CFS and could explain symptoms of nerve pain and muscle weakness. In this work, we performed a series of experiments on patient plasma samples where we isolated and characterized substrate-specific antibodies that digest MBP. We also tested glatiramer acetate (copaxone), an FDA approved immunomodulator to treat multiple sclerosis, and found that it inhibits ME/CFS antibody digestion of MBP. Furthermore, we found that aprotinin, which is a specific serine protease inhibitor, specifically prevents breakdown of MBP while the other classes of protease inhibitors had no effect. This coincides with the published literature describing catalytic antibodies as having serine protease-like activity. Postpandemic research has also provided several reports of demyelination in COVID-19. Because COVID-19 has been described as a trigger for ME/CFS, demyelination could play a bigger role in patient symptoms for those recently diagnosed with ME/CFS. Therefore, by studying proteolytic antibodies in ME/CFS, their target substrates, and inhibitors, a new mechanism of action could lead to better treatment and a possible cure for the disease.


Assuntos
Anticorpos Catalíticos , COVID-19 , Síndrome de Fadiga Crônica , Esclerose Múltipla , Humanos , Síndrome de Fadiga Crônica/tratamento farmacológico , Síndrome de Fadiga Crônica/epidemiologia , Síndrome de Fadiga Crônica/etiologia , Autoanticorpos , Esclerose Múltipla/tratamento farmacológico
2.
Langmuir ; 39(1): 101-110, 2023 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-36541659

RESUMO

A dielectrophoretic device employing a planar array of microelectrodes is designed for controlled transport of individual microparticles. By exciting the electrodes in sequence, a moving dielectrophoretic force is created that can drag a particle across the electrodes in a straight line. The electrode shapes are designed to counter any lateral drift of the trapped particle during transport. This facilitates single particle transport by creating a narrow two-dimensional corridor for the moving dielectrophoretic force to operate on. The design and analysis processes are discussed in detail. Numerical simulations are performed to calculate the electromagnetic field distribution and the generated dielectrophoretic force near the electrodes. The Langevin equation is used for analyzing the trajectory of a microparticle under the influence of the external forces. The simulations show how the designed electrode geometry produces the necessary lateral confinement required for successful particle transport. Finally, experimental results are presented showing controlled bidirectional linear transport of single polystyrene beads of radius 10 and 5 µm for a distances 840 and 1100 µm, respectively. The capabilities of the proposed platform make it suitable for micro total analysis systems (µTAS) and lab-on-a-chip (LOC) applications.


Assuntos
Dispositivos Lab-On-A-Chip , Poliestirenos , Microeletrodos , Eletroforese/métodos
3.
Electrophoresis ; 42(9-10): 1079-1092, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33599974

RESUMO

Electrically polarizable micro- and nanoparticles and droplets can be trapped using the gradient electric field of electrodes. But the spatial profile of the resultant dielectrophoretic force is fixed once the electrode structure is defined. To change the force profile, entire complex lab-on-a-chip systems must be re-fabricated with modified electrode structures. To overcome this problem, we propose an approach for the dynamic control of the spatial profile of the dielectrophoretic force by interfacing the trap electrodes with a resistor and an inductor to form a resonant resistor-inductor-capacitor (RLC) circuit. Using a dielectrophoretically trapped water droplet suspended in silicone oil, we show that the resonator amplitude, detuning, and linewidth can be continuously varied by changing the supply voltage, supply frequency, and the circuit resistance to obtain the desired trap depth, range, and stiffness. We show that by proper tuning of the resonator, the trap range can be extended without increasing the supply voltage, thus preventing sensitive samples from exposure to high electric fields at the stable trapping position. Such unprecedented dynamic control of dielectrophoretic forces opens avenues for the tunable active manipulation of sensitive biological and biochemical specimen in droplet microfluidic devices used for single-cell and biochemical reaction analysis.


Assuntos
Dispositivos Lab-On-A-Chip , Eletricidade , Eletrodos
4.
Nat Commun ; 15(1): 6159, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039069

RESUMO

Solid-phase synthesis underpins many advances in synthetic and combinatorial chemistry, biology, and material science. The immobilization of a reacting species on the solid support makes interfacing of reagents an important challenge in this approach. In traditional synthesis columns, this leads to reaction errors that limit the product yield and necessitates excess consumption of the mobile reagent phase. Although droplet microfluidics can mitigate these problems, its adoption is fundamentally limited by the inability to controllably interface microbeads and reagent droplets. Here, we introduce Dielectrophoretic Bead-Droplet Reactor as a physical method to implement solid-phase synthesis on individual functionalized microbeads by encapsulating and ejecting them from microdroplets by tuning the supply voltage. Proof-of-concept demonstration of the enzymatic coupling of fluorescently labeled nucleotides onto the bead using this reactor yielded a 3.2-fold higher fidelity over columns through precise interfacing of individual microreactors and beads. Our work combines microparticle manipulation and droplet microfluidics to address a long-standing problem in solid-phase synthesis with potentially wide-ranging implications.

5.
J Appl Phys ; 134(11): 113104, 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37736285

RESUMO

When it comes to simulate or calculate an optoelectronic tweezer (OET) response for a microparticle suspended in a given medium, a precise electrical conductivity (later referred to as conductivity) value for the microparticle is critical. However, there are not well-established measurements or well-referenced values for microparticle conductivities in the OET realm. Thus, we report a method based on measuring the escape velocity of a microparticle with a standard OET system to calculate its conductivity. A widely used 6 µm polystyrene bead (PSB) is used for the study. The conductivity values are found to be invariant around 2×10-3 S/m across multiple different aqueous media, which helps clarify the ambiguity in the usage of PSB conductivity. Our convenient approach could principally be applied for the measurement of multiple unknown OET-relevant material properties of microparticle-medium systems with various OET responses, which can be beneficial to carry out more accurate characterization in relevant fields.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA