Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 100: 39-46, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38104925

RESUMO

BACKGROUND: To evaluate the safety and efficacy of endovascular denervation (EDN) as an adjunct to percutaneous vascular intervention (PVI) for peripheral artery disease (PAD). METHODS: From August 2019 to April 2021, 38 eligible patients with PAD enrolled in this study were randomly and equally assigned into 2 groups: the PVI group and the PVI + EDN group treated with EDN at the iliac and femoral arteries before PVI. The primary endpoint was the improvement in the ankle brachial index at 6 months after the procedure. The secondary endpoints were transcutaneous oxygen pressure (TcPO2), Rutherford category, numerical rating scale score, and safety. RESULTS: The technical success rates of PVI and EDN were 100%, and no device-related or procedure-related major adverse events occurred in either group. Compared with PVI alone, PVI + EDN demonstrated a significant improvement in limb hemodynamics at 6 months (Δ ankle brachial index 0.44 ± 0.31 vs. 0.24 ± 0.15, P = 0.018). Microcirculatory perfusion of PAD was significantly better at 6 months in the PVI + EDN group (ΔTcPO2, 15.68 ± 16.72 vs. 4.95 ± 13.43, P = 0.036). The Rutherford category was significantly improved in the PVI + EDN group in comparison with the PVI group at the 3-month follow-up (100.00% vs. 68.42%, P = 0.02). The decrease in the numerical rating scale score in the PVI + EDN group was greater than that in the PVI group at 1 week following the procedure (3 [2-5] vs. 4 [4-6], P = 0.022). CONCLUSIONS: In this single-center pilot analysis of a heterogeneous cohort of patients with PAD, PVI with EDN demonstrated a significant improvement in limb ischemia at 6 months compared with PVI alone.


Assuntos
Procedimentos Endovasculares , Doença Arterial Periférica , Humanos , Microcirculação , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Isquemia/diagnóstico por imagem , Isquemia/cirurgia , Denervação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Fatores de Risco
2.
J Vasc Interv Radiol ; 34(7): 1135-1142, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36906134

RESUMO

PURPOSE: To analyze the risk factors for access-related adverse events (AEs) of the preclose technique in thoracic endovascular aortic repair (TEVAR). MATERIALS AND METHODS: Ninety-one patients with Stanford type B aortic dissection who underwent the preclose technique in TEVAR between January 2013 and December 2021 were included. According to the occurrence of access-related AEs, the patients were divided into 2 groups: those with AE and those without AE. Age, sex, combined diseases, body mass index, skin depth, femoral artery diameter, access calcification, iliofemoral artery tortuosity, and sheath size were recorded for risk factor analysis. The sheath-to-femoral artery ratio (SFAR), the ratio of the femoral artery inner diameter (in millimeters) to the sheath's outer diameter (in millimeters), was also included in the analysis. RESULTS: SFAR was identified as an independent risk factor for AEs using multivariable logistic analysis (odds ratio, 251.748; 95% CI, 7.004-9,048.534; P = .002). The cutoff value of SFAR was 0.85 and was related to a higher incidence of access-related AEs (5.2% vs 33.3%, P = .001), especially to a higher stenosis rate (0.0% vs 21.2%, P = .001). CONCLUSIONS: SFAR is an independent risk factor for access-related AEs of preclose in TEVAR with a cutoff value of 0.85. SFAR could be a new criterion for preoperative access evaluation in high-risk patients that may allow the detection and treatment of access-related AEs at the early stage.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Fatores de Risco , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos
3.
Acta Biomater ; 146: 495-505, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35487426

RESUMO

Biodegradable stents can degrade step by step and thereby avoid secondary removal by endoscopic procedures in contrast to metal stents. Herein, a biodegradable composite stent, a magnesium (Mg)-based braided stent with a surface coating of poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX), was designed and tested. By adding this drug-loaded polymer coating, the radial force of the stent increased from 33 Newton (N) to 83 N. PTX was continuously released as the stent degraded, and the in vitro cumulative drug release in phosphate-buffered saline for 28 days was 115 ± 13.5 µg/mL at pH = 7.4 and 176 ± 12 µg/mL at pH = 4.0. There was no statistically significant difference in the viability of fibroblasts of stent extracts with different concentration gradients (P > 0.05), while the PTX-loaded stents effectively promoted fibroblast apoptosis. In the animal experiment, the stents were able to maintain esophageal patency during the 3-week follow-up and to reduce the infiltration of inflammatory cells and the amount of fibrous tissue. These results showed that the PTX-PLGA-coated Mg stent has the potential to be a safe and effective approach for benign esophageal stricture. STATEMENT OF SIGNIFICANCE: We designed a biodegradable composite stent, having poly (lactic-co-glycolic acid) (PLGA) containing paclitaxel (PTX) coated the surface of the magnesium (Mg)-based braided stent. We evaluated in vitro and in vivo characteristics of the Mg esophageal stent having a PLGA coating plus a variable concentration of PTX in comparison with the absence of PTX PLGA coating. The PTX PLGA stents exerted higher radial force than stents without coating, degraded more quickly in an acid medium, and effectively promoted fibroblast apoptosis in vitro experiments. In a rabbit model of caustic-induced esophageal stricture, there was an increased lumen and decreased inflammation of the esophageal wall in the animals stented with PTX-PLGA versus the sham group, indicating a potential approach for benign esophageal stricture.


Assuntos
Estenose Esofágica , Paclitaxel , Animais , Magnésio/farmacologia , Paclitaxel/farmacologia , Polímeros , Coelhos , Stents
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA