Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 23(1): 404, 2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35490218

RESUMO

OBJECTIVE: To evaluate the relative performance of clinical readouts including serum C-reactive protein (CRP) levels, the erythrocyte sedimentation rate (ESR), globulin (GLB) levels, the albumin to GLB ratio (A/G), and the neutrophil to lymphocyte ratio (NLR) when diagnosing periprosthetic joint infection (PJI). METHODS: Clinical data was collected from 115 individuals diagnosed in our department between January 2017 and December 2020 with either chronic PJI (29 female, 24 male; median age 71.00 years [range, 41-94 years]) or aseptic loosening (30 female, 32 male; median age 68.50 years [range, 34-85 years]). Patient demographic data were compared, and the relative sensitivity and specificity of preoperative GLB, ESR, CRP, NLR, and A/G values as predictors of PJI diagnosis were assessed. RESULTS: Median globulin levels in the PJI and aseptic groups were 31.700 g/L (interquartile range [IQR], 28.400-35.300) and 26.600 g/L (IQR, 24.375-30.550), respectively (p < 0.001). The median A/G values in the PJI and aseptic groups were 1.150 (IQR, 0.960-1.255) and 1.510 (IQR, 1.265-1.670), respectively (p < 0.001). The median NLR values in the PJI and aseptic groups were 2.510 (IQR, 1.900-3.335) and 1.850 (IQR, 1.425 to 2.362), respectively (p < 0.001). The median ESR values in the PJI and aseptic groups were 53.000 mm/h (IQR, 35.000-76.500) and 16.000 mm/h (IQR, 7.000-33.000), respectively (p < 0.001). Median CRP levels in the PJI and aseptic groups were 24.890 mg/L (IQR, 10.595-54.095) and 2.245 mg/L (IQR, 0.865-8.6075), respectively (p < 0.001). Area under the receiver operating characteristic (ROC) curve (AUC) values for CRP, ESR, GLB, A/G, and NLR were 0.841 (95% confidence interval, 0.761-0.903), 0.850 (0.771-0.910), 0.747 (0.658-0.824), 0.779 (0.692-0.851), and 0.708 (0.616-0.789), respectively. When GLB > 26.6 g/L, A/G < 1.32, and NLR > 2.1 were utilized as threshold values to diagnose PJI, GLB and A/G were found to exhibit superior sensitivity (90.57%, 81.13%) to that observed for CRP (71.70%) and ESR (79.25%), but the specificity of these two metrics (GLB: 51.61%, A/G: 72.58%) was significantly reduced relative to that for CRP (87.10%) or ESR (75.81%). ROC analyses further revealed that NLR did not exhibit significant advantages in sensitivity (73.58%) or specificity (70.97%) relative to CRP or ESR. CONCLUSION: Globulin levels, NLR values, and A/G values do not outperform ESR or CRP levels when used to diagnose PJI.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Globulinas , Infecções Relacionadas à Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Albuminas/análise , Artrite Infecciosa/cirurgia , Biomarcadores , Sedimentação Sanguínea , Proteína C-Reativa/análise , Feminino , Humanos , Linfócitos/metabolismo , Masculino , Pessoa de Meia-Idade , Neutrófilos/química , Neutrófilos/metabolismo , Infecções Relacionadas à Prótese/cirurgia
2.
Food Chem ; 428: 136780, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37413833

RESUMO

Foodborne illness caused by Staphylococcus aureus (S. aureus) has posed a significant threat to human health. Herein, an integrated multifunctional nanoplatform was developed for fluorescence detection and inactivation of S. aureus based on cascade signal amplification coupled with single strand DNA-template copper nanoparticles (ssDNA-Cu NPs). Benefiting from reasonable design, one-step cascade signal amplification was achieved through strand displacement amplification combined with rolling circle amplification, followed by in-situ generation of copper nanoparticles. S. aureus detection could be performed through naked eye observation and microplate reader measurement of the red fluorescence signal. The multifunctional nanoplatform had satisfactory specificity and sensitivity, achieving 5.2 CFU mL-1 detection limit and successful detection of 7.3 CFU of S. aureus in spiked egg after < 5 h of enrichment. Moreover, ssDNA-Cu NPs could eliminate S. aureus to avoid secondary bacterial contamination without further treatment. Therefore, this multifunctional nanoplatform has potential application in food safety dtection.


Assuntos
Técnicas Biossensoriais , Staphylococcus aureus , Humanos , Staphylococcus aureus/genética , Cobre , Técnicas de Amplificação de Ácido Nucleico , DNA de Cadeia Simples , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA