Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ind Health ; 46(4): 397-403, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18716389

RESUMO

We report findings regarding otolaryngologist-confirmed rhinitis, current exposure to MWF aerosols, fungi, and endotoxins for workers in a plant manufacturing automobile piston rings. Questionnaire data showed that 61.5% of 187 workers exhibited rhinitis-related symptoms. Rhinitis was confirmed in 99 of 115 workers whom were medically examined. Otolaryngologist-confirmed rhinitis was present in 10 of 19 grinding workers (52.6%), 67 of 142 production workers (47.2%), and 22 of 26 quality control (QC) workers (84.6%). These rates are much higher than the rates of rhinitis-related symptoms in automobile plants and other occupational settings and quite high even allowing for the common occurrence of rhinitis in the general population. We found that rhinitis could develop even in workers exposed to less than 0.5mg/m(3) MWF aerosol. The average exposure to fungi exceeded 10 x 10(3) CFU/m(3), a level higher than that reported for other automobile plants. Although we were unable to identify significant risk factors for rhinitis using only the physician-confirmed rhinitis cases, this study concludes that exposure to MWF aerosol, which would include microbes and metals, could contribute to a high occurrence of rhinitis in grinding and production workers. Forty-nine workers (63.6%) of 77 rhinitis patients in grinding and production operations were determined to handle synthetic MWF directly. For QC workers, for whom the prevalence of physician-confirmed rhinitis was highest, exposure to a low level of MWF aerosol, including specific microbe species we couldn't identify, bright light, dry air, and certain work characteristics during inspection are possible risk factors for development of rhinitis. Further studies including identification of fungi species should be conducted so a firm conclusion can be made regarding the development of rhinitis in QC manufacturing plant workers.


Assuntos
Exposição Ocupacional , Rinite/epidemiologia , Adulto , Aerossóis , Automóveis , Feminino , Humanos , Indústrias , Coreia (Geográfico)/epidemiologia , Masculino , Pessoa de Meia-Idade , Rinite/diagnóstico , Rinite/etiologia , Inquéritos e Questionários
2.
J Occup Health ; 50(2): 212-20, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18403875

RESUMO

The main objective of this study was to determine the association between synthetic metalworking fluid (MWF) and rhinitis-related symptoms. At a plant manufacturing piston rings for automobiles, we interviewed grinders (19) and manufacturing workers (142) in operations where synthetic or semisynthetic MWF is handled, and administrative office workers (44) regarding the principal symptoms of rhinitis (nasal stuffiness, runny nose, anosmia, nasal itchiness, rhinorrhea, headache, epistaxis, and post-nasal drip). In addition, we assessed the current exposure of workers handling MWF to MWF aerosols, fungi, and endotoxins. Logistic regression analysis was used to examine the association between MWF surrogates indicative of MWF exposure and each rhinitis-related nasal symptom. Odds ratios (ORs) and 95% confidence intervals were adjusted for sex, age, smoking habit, and duration of employment. Among grinders handling synthetic MWF, the frequency of complaints of the dominant symptoms was 66.7% for nasal stuffiness, 77.8% for anosmia, 77.8% for runny nose, and 50.0% for headache. These rates are quite high even allowing for the common occurrence of rhinitis in the general population. Twenty eight of 34 grinding and manufacturing workers (82.4%) sampled were exposed to MWF mist above the threshold limit of 0.2 mg/m(3) listed as a notice of intended change by the American Conference for Governmental Industrial Hygienists (ACGIH). The percentage of workers exposed to MWF mist >0.5 mg/m(3) was 17.6%. Most workers were exposed to fungi levels >103 CFU/m(3). All exposures to endotoxins were <50 EU/m(3). Logistic regression analysis found that use of synthetic MWF was significantly associated with excess risk of nasal stuffiness (OR 3.5), nasal itchiness (OR 2.0), and runny nose (OR 2.1). The use of semi-synthetic MWF had little or no impact on the risk of developing rhinitis-related nasal symptoms. Grinding workers handling synthetic MWF had an increased risk of nasal stuffiness (OR 7.9), anosmia (OR 23.2), nasal itchiness (OR 8.3), runny nose (OR 20.4), post nasal drip (OR 18.4), and headache (OR 7.4) compared to administrative workers. Synthetic MWF may play an important role in the development of the dominant symptoms of rhinitis. Further study is needed to establish the risk of rhinitis or rhinitis-related symptoms according to MWF type.


Assuntos
Exposição por Inalação/efeitos adversos , Metalurgia , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Rinite/etiologia , Adulto , Poluentes Ocupacionais do Ar/efeitos adversos , Estudos de Casos e Controles , Relação Dose-Resposta a Droga , Endotoxinas/análise , Feminino , Fungos/isolamento & purificação , Humanos , Óleos Industriais/intoxicação , Lubrificantes/intoxicação , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/induzido quimicamente , Doenças Profissionais/epidemiologia , Rinite/induzido quimicamente , Rinite/epidemiologia , Fatores de Risco , Fumar/efeitos adversos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA