Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Dent Anesth Pain Med ; 24(3): 205-211, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38840645

RESUMO

A 7-year-old girl visited the Samsung Medical Center emergency room for primary tooth aspiration during primary tooth extraction under conscious sedation with N2O. The patient showed no signs of respiratory complications. Chest radiography and CT revealed a tooth in the right bronchi. Foreign body removal using rigid bronchoscopy was performed on the day of aspiration. With close monitoring of the airway in the pediatric ICU, extubation was performed the next day, and the patient was discharged the same day. The primary objective of this case report was to highlight the potential risk of aspiration associated with the use of N2O gas for conscious sedation.

2.
BMB Rep ; 53(6): 299-310, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32475383

RESUMO

Chronic liver disease progresses through several stages, fatty liver, steatohepatitis, cirrhosis, and eventually, it leads to hepatocellular carcinoma (HCC) over a long period of time. Since a large proportion of patients with HCC are accompanied by cirrhosis, it is considered to be an important factor in the diagnosis of liver cancer. This is because cirrhosis leads to an irreversible harmful effect, but the early stages of chronic liver disease could be reversed to a healthy state. Therefore, the discovery of biomarkers that could identify the early stages of chronic liver disease is important to prevent serious liver damage. Biomarker discovery at liver cancer and cirrhosis has enhanced the development of sequencing technology. Next generation sequencing (NGS) is one of the representative technical innovations in the biological field in the recent decades and it is the most important thing to design for research on what type of sequencing methods are suitable and how to handle the analysis steps for data integration. In this review, we comprehensively summarized NGS techniques for identifying genome, transcriptome, DNA methylome and 3D/4D chromatin structure, and introduced framework of processing data set and integrating multi-omics data for uncovering biomarkers. [BMB Reports 2020; 53(6): 299-310].


Assuntos
Biomarcadores Tumorais/genética , Carcinoma Hepatocelular/genética , Sequenciamento de Nucleotídeos em Larga Escala , Cirrose Hepática/genética , Neoplasias Hepáticas/genética , Carcinoma Hepatocelular/diagnóstico , Humanos , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/diagnóstico
3.
Neurointervention ; 12(1): 31-39, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28316867

RESUMO

PURPOSE: To better understand the performance of four commercially available neurovascular stents in intracranial aneurysm embolization, the stents were compared in terms of their basic morphological and mechanical properties. MATERIALS AND METHODS: Four different types of stents that are currently being used for cerebral aneurysm embolization were prepared (two stents per type). Two were laser-cut stents (Neuroform and Enterprise) and two were braided from a single nitinol wire (LEO and LVIS stents). All were subjected to quantitative measurements of stent size, pore density, metal coverage, the force needed to load, push, and deploy the stent, radial force on deployment, surface roughness, and corrosion resistance. RESULTS: Compared to their nominal diameters, all stents had greater diameters after deployment. The length generally decreased after deployment. This was particularly marked in the braided stents. The braided stents also had higher pore densities than the laser-cut stents. Metal coverage was highest in the LEO stent (14%) and lowest in the Enterprise stent (5%). The LIVS stent had the highest microcatheter loading force (81.5 gf). The LEO stent had the highest passage force (55.0 gf) and deployment force (78.9 gf). The LVIS and LEO stents had the highest perpendicular (37.1 gf) and circumferential (178.4 gf) radial forces, respectively. The Enterprise stent had the roughest stent wire, followed by the LVIS, LEO, and Neuroform stents. CONCLUSION: The four neurovascular stent types differed in terms of morphological and physical characteristics. An understanding of this diversity may help to decide which stent is most suitable for specific clinical situations.

4.
Neurointervention ; 12(1): 3-10, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28316864

RESUMO

PURPOSE: Onyx has been successfully applied in the treatment of various neurovascular lesions. However, some experience is required to get accustomed to its unpredictable fluoroscopic visibility during injection. This in vitro study aimed to evaluate the characteristics of radiopacity change in a simulated embolization procedure. MATERIALS AND METHODS: Using a bench-top Onyx injection experiment simulating a typical brain arteriovenous malformation embolization, nine cycles of casting modes (continuous injection) and plugging modes (injection with intermittent pauses) were performed. Radiodensity of Onyx droplets collected from the microcatheter tip and the distal head portion of the microcatheter were measured as time lapsed. Distribution of droplet radiodensity (radiodensity) and distribution of radiographic grade (grade) were analyzed and compared by repeated measurements. RESULTS: Within-group analysis revealed no significant radiodensity change with time (P>0.05). The radiodensity was significantly higher in the casting mode than in the plugging mode (P<0.01). The lateral radiograph of the microcatheter showed higher radiopacity (P<0.01) and better evenness (P<0.01) in the casting mode than in the plugging mode. A significant difference in microcatheter attenuation (both radiographic grade mean and SD; P<0.01) was noted between the two modes. Radiodensity had a significant influence on the radiopacity and radiopacity evenness of the microcatheter. CONCLUSION: The radiopacity of the Onyx can vary significantly over time because of early precipitation of tantalum powder. Radiopacity decreased significantly during plugging modes, characterized by pauses between injections.

5.
Neurointervention ; 10(2): 82-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26389011

RESUMO

PURPOSE: Hypothesizing that the parent artery (PA) diameter of the aneurysm-neck segment is larger than those of normal segments, especially in wide-necked aneurysm cases, we conducted 3D angiographic analyses in wide-necked aneurysm cases focusing on the luminal morphologic change of the PA. MATERIALS AND METHODS: Under the approval of local IRB, we enrolled 26 patients with distal internal carotid artery (ICA) aneurysms, which were treated with stent assisted coiling. The PA diameters along the centerline were measured at 6 points with built-in software by two observers. Those 6 points were P1 and P2 proximally, P3 and P4 at the aneurysm ostium margins, and P5 and P6 distally. We performed an ANOVA test and a Bonferroni method for post hoc analyses. Linear regression analysis was performed to find any morphologic influencing factors. RESULTS: There were 20 distal ICA aneurysms out of 26 consecutive cases after exclusion. The differences in diameter at each point were statistically significant (p<0.0001). On post hoc analyses, the difference between P4 and P5 was significant both in maximum and mean PA diameters (p<0.0001 and p<0.001, respectively). Multivariate analyses failed to reveal any morphological influencing factor. CONCLUSION: PAs harboring a wide-necked aneurysm requiring stent assistance for coiling showed significant enlargement of the lumen, especially at the distal transition segment of the aneurysm ostium and the PA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA