Can J Anaesth ; 71(4): 523-534, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38438682

RESUMO

PURPOSE: The severity of bleeding events is heterogeneously defined during peripheral veno-arterial extracorporeal membrane oxygenation (pVA-ECMO). We studied three bleeding definitions in pVA-ECMO: the Extracorporeal Life Support Organization (ELSO)-serious bleeding, the Bleeding Academic Research Consortium (BARC), and the universal definition of postoperative bleeding (UPDB) classifications. METHODS: We included consecutive adult patients supported by pVA-ECMO for refractory cardiogenic shock admitted to Lille academic hospitals between January 2013 and December 2019. We assessed the association of bleeding definitions with the primary endpoint of 28-day all-cause mortality with the use of multivariate models accounting for time-dependent and competing variables. We compared models' performances using the Harrell's C-Index and the Akaike information criteria. RESULTS: Twenty-eight-day mortality occurred in 128/308 (42%) 308 patients. The ELSO-serious bleeding (hazard ratio [HR], 1.67; 95% confidence interval [CI], 1.09 to 2.56) and BARC ≥ type 2 (HR, 1.55; 95% CI, 1.01 to 2.37) were associated with 28-day mortality (Harrell's C-index, 0.69; 95% CI, 0.63 to 0.74 for both). Predictors of ELSO-serious bleeding were postcardiotomy, body mass index, baseline platelets count, fibrinogen, and hemoglobin levels. CONCLUSION: Extracorporeal Life Support Organization-serious bleeding and BARC ≥ type 2 are relevant definitions of major bleeding regarding their association with mortality in critically ill patients who survived the first 24 hr while supported with pVA-ECMO for cardiogenic shock. STUDY REGISTRATION: CERAR (IRB 00010254-2022-050, Paris, France); first submitted on 18 April 2022.


RéSUMé: OBJECTIF: La gravité des événements hémorragiques est définie de manière hétérogène pendant une oxygénation par membrane extracorporelle veino-artérielle périphérique (ECMO-VA périphérique). Nous avons étudié trois définitions du saignement sous ECMO-VA périphérique : les classifications des saignements graves selon l'Extracorporeal Life Support Organization (ELSO), celles du Bleeding Academic Research Consortium (BARC) et la définition universelle du saignement postopératoire (UPDB). MéTHODE: Nous avons inclus des patient·es adultes pris·es en charge de manière consécutive par ECMO-VA périphérique à la suite d'un choc cardiogénique réfractaire et admis·es dans les centres hospitaliers universitaires de Lille entre janvier 2013 et décembre 2019. Nous avons évalué l'association des définitions du saignement avec le critère d'évaluation principal de mortalité toutes causes confondues à 28 jours à l'aide de modèles multivariés tenant compte des variables dépendantes du temps et concurrentes. Nous avons comparé les performances des modèles à l'aide de l'indice C de Harrell et du critère d'information d'Akaike. RéSULTATS: La mortalité à 28 jours est survenue chez 128/308 (42 %) patient·es. Le saignement grave selon l'ELSO (rapport de risque [RR], 1,67; intervalle de confiance [IC] à 95 %, 1,09 à 2,56) et une classification BARC ≥ type 2 (RR, 1,55; IC 95 %, 1,01 à 2,37) étaient associés à une mortalité à 28 jours (indice C de Harrell, 0,69; IC 95 %, 0,63 à 0,74 pour les deux). Les prédicteurs d'hémorragie grave selon l'ELSO étaient la postcardiotomie, l'indice de masse corporelle, la numération plaquettaire initiale, le taux de fibrinogène et les taux d'hémoglobine. CONCLUSION: Les définitions du saignement grave de l'Extracorporeal Life Support Organization et une classification BARC ≥ type 2 sont des définitions pertinentes des saignements majeurs en ce qui touche à leur association avec la mortalité chez les personnes gravement malades qui ont survécu aux premières 24 heures alors qu'elles étaient prises en charge par ECMO-VA périphérique à la suite d'un choc cardiogénique. ENREGISTREMENT DE L'éTUDE: CERAR (IRB 00010254-2022-050, Paris, France); soumis pour la première fois le 18 avril 2022.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque Cardiogênico , Adulto , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Estudos de Coortes , Estado Terminal , Hemorragia , Mortalidade Hospitalar , Estudos Retrospectivos
2.
Circulation ; 146(5): 383-397, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35722876

RESUMO

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Assuntos
Hemorragia Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/etiologia , Feminino , Fluoroscopia , Hemostáticos , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Fator de von Willebrand
3.
Am Heart J ; 262: 140-147, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37100186

RESUMO

BACKGROUND: Severe aortic stenosis (AS) has been associated with bleeding. However, there is a lack of prospective assessment of bleeding events and their clinical significance in a large population of outpatients with variable degree of AS severity. OBJECTIVES: To assess the incidence, source, determinants, and prognostic impact of major bleeding in patients with variable degree of AS severity. METHODS: Between May 2016 and December 2017, consecutive outpatients were included. Major bleeding was defined as type ≥3 bleed using the Bleeding Academic Research Consortium definition. Cumulative incidence was calculated with death as the competing event. Data was censored at time of aortic valve replacement. RESULTS: Among 2,830 patients, 46 major bleeding events occurred (0.7%/year) during a median follow-up of 2.1 years (interquartile range: 1.4-2.7). Most frequent sites of bleeding were gastrointestinal (50%) and intracranial (30.4%). Major bleeding was significantly associated with all-cause mortality (hazard ratio: 5.93 (95% confidence interval 3.64-9.65); P < .001). AS severity was associated with major bleedings (P = .041). By multivariable analysis, severe AS was an independent determinant of major bleeding (hazard ratio vs mild AS: 3.59 [95% confidence interval 1.56-8.29]; P = .003). The increased risk of bleeding associated with severe AS was significantly exacerbated in patients using oral anticoagulation. CONCLUSION: In AS patients, major bleeding is rare but a strong independent predictor of death. AS severity is a determinant of bleeding events. Severe AS and oral anticoagulation should be identified as an association at very high risk of major bleeding.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Prognóstico , Incidência , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/epidemiologia , Hemorragia/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Anticoagulantes/uso terapêutico , Resultado do Tratamento
4.
New Microbiol ; 46(2): 223-225, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37247246

RESUMO

Corynebacterium pseudodiphtheriticum, a Gram-positive rod belonging the oropharynx microbiota, is usually described in pulmonary infections, especially in immunocompromised patients. This paper describes a rare case of native aortic infectious endocarditis (IE) and reviews the literature on similar cases. A 62-year-old man with rheumatic fever since childhood was hospitalized for surgical treatment of a febrile IE due to C. diphtheriticum with a large vegetation (15.8 X 8.3 mm). MALDI-TOF-MS from strain isolated in positive blood cultures identified C. pseudodiphtheriticum (2.34), and 16S rRNA sequencing from the valve sample confirmed the identification. The summary of 25 cases shows that the outcome of an IE due to C. pseudodiphtheriticum is bad. The review of the literature shows that this agent found in blood cultures in a cardiovascular context deserves to be explored meticulously because an unfavorable prognosis is frequent.


Assuntos
Endocardite Bacteriana , Endocardite , Masculino , Humanos , Criança , Pessoa de Meia-Idade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , RNA Ribossômico 16S/genética , Corynebacterium/genética , Endocardite/complicações
5.
Catheter Cardiovasc Interv ; 99(6): 1829-1838, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35324050

RESUMO

OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
6.
Crit Care ; 26(1): 257, 2022 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-36028883

RESUMO

BACKGROUND: The mortality rate for a patient with a refractory cardiogenic shock on venoarterial (VA) extracorporeal membrane oxygenation (ECMO) remains high, and hyperoxia might worsen this prognosis. The objective of the present study was to evaluate the association between hyperoxia and 28-day mortality in this setting. METHODS: We conducted a retrospective bicenter study in two French academic centers. The study population comprised adult patients admitted for refractory cardiogenic shock. The following arterial partial pressure of oxygen (PaO2) variables were recorded for 48 h following admission: the absolute peak PaO2 (the single highest value measured during the 48 h), the mean daily peak PaO2 (the mean of each day's peak values), the overall mean PaO2 (the mean of all values over 48 h), and the severity of hyperoxia (mild: PaO2 < 200 mmHg, moderate: PaO2 = 200-299 mmHg, severe: PaO2 ≥ 300 mmHg). The main outcome was the 28-day all-cause mortality. Inverse probability weighting (IPW) derived from propensity scores was used to reduce imbalances in baseline characteristics. RESULTS: From January 2013 to January 2020, 430 patients were included and assessed. The 28-day mortality rate was 43%. The mean daily peak, absolute peak, and overall mean PaO2 values were significantly higher in non-survivors than in survivors. In a multivariate logistic regression analysis, the mean daily peak PaO2, absolute peak PaO2, and overall mean PaO2 were independent predictors of 28-day mortality (adjusted odds ratio [95% confidence interval per 10 mmHg increment: 2.65 [1.79-6.07], 2.36 [1.67-4.82], and 2.85 [1.12-7.37], respectively). After IPW, high level of oxygen remained significantly associated with 28-day mortality (OR = 1.41 [1.01-2.08]; P = 0.041). CONCLUSIONS: High oxygen levels were associated with 28-day mortality in patients on VA-ECMO support for refractory cardiogenic shock. Our results confirm the need for large randomized controlled trials on this topic.


Assuntos
Oxigenação por Membrana Extracorpórea , Hiperóxia , Adulto , Humanos , Oxigênio , Pontuação de Propensão , Estudos Retrospectivos , Choque Cardiogênico
7.
Heart Lung Circ ; 31(1): e1-e4, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34600813

RESUMO

Minimally invasive cardiac surgery is mainly dedicated to acquired left-sided valve diseases. Ministernotomy is widely used for aortic valve repair or replacement, whereas pulmonary valve repair via this approach has been reported only recently. This article aims to describe the use of ministernotomy for pulmonary valve replacement in adult congenital patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Adulto , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento
8.
Ann Vasc Surg ; 77: 348.e7-348.e11, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34437965

RESUMO

Disease-causing heterozygous variants in the ACTA2 gene cause an autosomal dominant heritable thoracic aortic disease (HTAD) with thoracic aortic aneurysm and dissection as main phenotype, and occasional extravascular abnormalities such as livedo reticularis. ACTA2-HTAD accounts for an important part of non-syndromic HTAD, with detection rates varying between 1.5-21% according to different studies. A consensus statement for the screening and management of patients with pathogenic ACTA2 variants has been recently published by the European reference network for rare vascular diseases (VASCERN). However, management of ACTA2 patients is often challenged by extremely variable inter- and intra-familial clinical courses of the disease. Here we report a family harboring a disease-causing ACTA2 variant. The proband and two siblings presented with acute type A aortic dissection and rupture involving nondilated aortic segments before the age of 30. Their mother died at 49 years-old from type B aortic dissection and rupture. Genetic testing revealed the heterozygous novel p.(Pro335Arg) variant in the ACTA2 gene in the proband and in the affected siblings. The clinical history of this family highlights the difficulty of adopting effective prevention strategies in ACTA2 patients.


Assuntos
Actinas/genética , Aneurisma da Aorta Torácica/genética , Dissecção Aórtica/genética , Ruptura Aórtica/genética , Variação Genética , Adulto , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Progressão da Doença , Feminino , Predisposição Genética para Doença , Hereditariedade , Heterozigoto , Humanos , Linhagem , Fenótipo
9.
BMC Pulm Med ; 21(1): 401, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34872556

RESUMO

INTRODUCTION: Association between sleep nocturnal breathing disorders and acute aortic syndrome (AAS) has been described but mid-term data are scarce. OBJECTIVES: We assessed the prognostic value of sleep apnea parameters and their relationship with aortic morphology after the onset of a type B AAS. METHODS: Between January 2010 and January 2018, sleep apnea screening in post type B AAS was prospectively performed. The association of sleep apnea parameters with aortic morphology and aortic expansion during follow-up was studied. RESULTS: Over the 8-year-study period, 103 patients were included, with a mean age of 57.8 ± 12.1 years old. Median follow-up was 25.0 months (11.0-51.0). Thirty-two patients (31%) required aortic stenting during the acute phase. In patients treated by aortic stenting, the descending thoracic aortic diameter was positively associated with a higher percentage of nocturnal time of saturation ≤ 90% after adjustment (p = 0.016). During follow-up, the nocturnal time of saturation ≤ 90% in patients treated by medical therapy was the only parameter associated with significant aortic expansion rate (r = 0.26, p = 0.04). Thirty-eight patients started and sustained nocturnal ventilation during follow-up. The association between aortic expansion rate and nocturnal time of saturation ≤ 90% did not persist during follow-up after adjustment on nocturnal ventilation initiation (r = 0.25, p = 0.056). CONCLUSIONS: Nocturnal hypoxemia parameters are positively associated with the max onset aortic diameter and significant aortic growth after type B AAS. Nocturnal ventilation seems to mitigate aortic expansion during follow-up.


Assuntos
Dissecção Aórtica/complicações , Dissecção Aórtica/patologia , Hipóxia/complicações , Síndromes da Apneia do Sono/complicações , Adulto , Idoso , Dissecção Aórtica/cirurgia , Feminino , França , Humanos , Hipóxia/terapia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Respiração Artificial/métodos , Síndromes da Apneia do Sono/terapia , Stents
10.
J Card Surg ; 35(5): 981-987, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32176383

RESUMO

BACKGROUND: After an emergent surgery for type A acute aortic syndrome, medical management is based on optimal blood pressure (BP) control. We assessed the prognostic significance of BP monitoring and its relationship with aortic morphology following type A acute aortic syndrome. METHODS: The data of 120 patients who underwent BP monitoring after a type A acute aortic syndrome from January 2005 to June 2016 were retrospectively collected. The first CT angiogram performed after surgery was used for the morphological analysis. RESULTS: The population included 79 males, with an overall mean age of 60 ± 12 years. Seven patients (5.8%) died during a median follow-up of 5.5 years. The median delay between BP monitoring and discharge was 3 (1-5) months. The mean 24-hour BP of the cohort was 127/73 mm Hg ± 10/17. During follow-up, different parameters of BP monitoring were not associated with the risk of aortic events. However, the diameter of the false lumen of the descending thoracic aorta was the best predictor associated with the risk of new aortic events during follow-up, particularly for the threshold of 28 mm or more (P < .001; Hazard ratio 4.7[2.7-8.2]). The diameter of the false lumen was associated with night-time systolic BP (P = .025; r = .2), 24-hour pulse pressure (P = .002; r = .28), and night-time pulse pressure (P = .008; r = .24). CONCLUSION: The risk of new aortic events following type A acute aortic syndrome is associated with the size of the residual false lumen, but not directly with BP parameters. Night-time BP parameters are associated with the size of the residual false lumen.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Dissecção Aórtica/patologia , Dissecção Aórtica/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial , Pressão Sanguínea , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Risco
11.
N Engl J Med ; 375(4): 335-44, 2016 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-27464202

RESUMO

BACKGROUND: Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. METHODS: We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. RESULTS: After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. CONCLUSIONS: The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.).


Assuntos
Difosfato de Adenosina/sangue , Insuficiência da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/diagnóstico , Substituição da Valva Aórtica Transcateter , Fator de von Willebrand/análise , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Biomarcadores/sangue , Feminino , Hemostasia/fisiologia , Humanos , Masculino , Análise Multivariada , Testes Imediatos , Complicações Pós-Operatórias/sangue , Curva ROC , Sensibilidade e Especificidade , Fator de von Willebrand/química
12.
Sleep Breath ; 23(2): 439-446, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30043386

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is associated with an increased aortic root size. This association has never been studied in patients with hypertension undergoing continuous positive airway pressure (CPAP) treatment for OSA. METHODS: The 24-h blood pressure (BP) monitoring of 142 hypertensive patients undergoing CPAP treatment for OSA was prospectively documented. Aortic root diameter was assessed by echocardiography. RESULTS: The population included 33.8% women, with an overall mean age of 60.7 ± 10.5 years. The median body mass index was 32.7 [29. 5-36.3] kg/m2. The median treatment score was 3 [2-4] anti-hypertensive drugs per day. The median 24-h systolic and diastolic BP were 130 [120-144] and 74.5 [69-82] mmHg, respectively. The night-time systolic and diastolic BP were 119.5 [108-136] and 67 [61-74] mmHg, respectively. The mean diameter of the aorta at the level of the Valsalva sinuses was 34.9 ± 4.4 mm and 20.4 ± 2.3 mm/m when adjusted for height. Patients underwent ventilation for a median duration of 3.8 [1. 7-7.5] years, with a median night-time duration of 6.6 [5. 5-7.5] h per night. The median residual apnea-hypopnea index under ventilation was 2 [1-4] events per hour. A multivariate analysis showed that aortic root size was associated with male gender (p < 0.01) and nocturnal diastolic BP (p < 0.01). When normalized for height, aortic root diameter was positively associated with age (p < 0.01) and nocturnal diastolic BP (p < 0.01). CONCLUSION: In OSA patients, the relationship between aortic root diameter and nocturnal BP persists on CPAP therapy. Further studies that evaluate the potential protective effect of OSA treatment on aortic root dilatation should monitor nocturnal diastolic BP.


Assuntos
Aorta Torácica/fisiopatologia , Pressão Sanguínea/fisiologia , Ritmo Circadiano/fisiologia , Hipertensão/fisiopatologia , Hipertensão/terapia , Apneia Obstrutiva do Sono/fisiopatologia , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/patologia , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas , Ecocardiografia , Feminino , Humanos , Hipertensão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão/fisiologia , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/terapia
13.
Circ Res ; 116(7): 1193-201, 2015 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-25670067

RESUMO

RATIONALE: Percutaneous aortic valve procedures are a major breakthrough in the management of patients with aortic stenosis. Residual gradient and residual aortic regurgitation are major predictors of midterm and long-term outcome after percutaneous aortic valve procedures. We hypothesized that (1) induction/recovery of high molecular weight (HMW) multimers of von Willebrand factor defect could be instantaneous after acute changes in blood flow, (2) a bedside point-of-care assay (platelet function analyzer-closure time adenine DI-phosphate [PFA-CADP]), reflecting HMW multimers changes, could be used to monitor in real-time percutaneous aortic valve procedures. OBJECTIVE: To investigate the time course of HMW multimers changes in models and patients with instantaneous induction/reversal of pathological high shear and its related bedside assessment. METHODS AND RESULTS: We investigated the time course of the induction/recovery of HMW multimers defects under instantaneous changes in shear stress in an aortic stenosis rabbit model and in patients undergoing implantation of a continuous flow left ventricular assist device. We further investigated the recovery of HMW multimers and monitored these changes with PFA-CADP in aortic stenosis patients undergoing transcatheter aortic valve implantation or balloon valvuloplasty. Experiments in the aortic stenosis rabbit model and in left ventricular assist device patients demonstrated that induction/recovery of HMW multimers occurs within 5 minutes. Transcatheter aortic valve implantation patients experienced an acute decrease in shear stress and a recovery of HMW multimers within minutes of implantation which was sustained overtime. In patients with residual high shear or with residual aortic regurgitation, no recovery of HMW multimers was observed. PFA-CADP profiles mimicked HMW multimers recovery both in transcatheter aortic valve implantation patients without aortic regurgitation (correction) and transcatheter aortic valve implantation patients with aortic regurgitation or balloon valvuloplasty patients (no correction). CONCLUSIONS: These results demonstrate that variations in von Willebrand factor multimeric pattern are highly dynamic, occurring within minutes after changes in blood flow. It also demonstrates that PFA-CADP can evaluate in real time the results of transcatheter aortic valve procedures.


Assuntos
Valva Aórtica/cirurgia , Coração Auxiliar , Hemorreologia , Multimerização Proteica , Substituição da Valva Aórtica Transcateter , Fator de von Willebrand/química , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Animais , Insuficiência da Valva Aórtica/sangue , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Biomarcadores , Velocidade do Fluxo Sanguíneo , Sistemas Computacionais , Modelos Animais de Doenças , Feminino , Humanos , Masculino , Testes de Função Plaquetária/métodos , Estudos Prospectivos , Coelhos
14.
Artif Organs ; 40(9): 904-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26684540

RESUMO

Out-of-Hospital refractory Cardiac Arrest (OHrCA) has a mortality rate between 90 and 95%. Since 2009, French medical academic societies have recommended the use of extracorporeal life support (ECLS) for OHrCA. According to these guidelines, patients were eligible for ECLS support if vital signs were still present during cardiopulmonary resuscitation (CPR), or if cardiac arrest was secondary to intoxication or hypothermia (≤32°C). Otherwise, patients would receive ECLS if (i) no-flow duration was less than 5 min; (ii) time delays from CPR to ECLS start (low flow) were less than 100 min; and (iii) expiratory end tidal CO2 (ETCO2 ) was more than 10 mm Hg 20 min after initiating CPR. We have reported here our experience with ECLS in OHrCA according to the previous guidelines. We retrospectively analyzed mortality rates of patients supported with ECLS in case of OHrCA. From December 2009 to December 2013, 183 patients were assisted with ECLS, among which 32 cases were of OHrCA. Mean age for the OHrCA patients was 43.6 years. Over two-thirds were male (71.9%). Causes of OHrCA included intoxication, isolated hypothermia <32°C, acute coronary syndrome, pulmonary edema, and other cardiac pathology. Despite adherence to protocols, only two patients (6.2%) with hypothermia and acute myocardium ischemia, respectively, could be discharged from hospital after cardiac recovery. Causes of death were brain death and multiple organ failure. Despite ECLS support setting in accordance with French guidelines in case of refractory OHrCA, mortality rates remained high. French ECLS support recommendations for OHrCA due to presumed cardiac cause should be re-examined through new studies. Low flow duration should be improved by a shorter time of CPR before hospital transfer.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Adulto , Suporte Vital Cardíaco Avançado/métodos , Reanimação Cardiopulmonar/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/cirurgia , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Análise de Sobrevida
15.
Circulation ; 129(13): 1415-27, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24566199

RESUMO

BACKGROUND: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. METHODS AND RESULTS: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1-Q3=178-490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P=0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery (P=0.04), larger aortic annulus (P=0.0004), and smaller prosthesis diameter (P=0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery(P=0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P=0.0001) and SE-TAVR (hazard ratio=2.11; P=0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR

Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Seguimentos , França , Próteses Valvulares Cardíacas , Humanos , Incidência , Estudos Longitudinais , Masculino , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
17.
Circulation ; 127(15): 1597-608, 2013 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-23487435

RESUMO

BACKGROUND: To assess the prevalence, determinants, and prognosis value of right ventricular (RV) ejection fraction (EF) impairment in organic mitral regurgitation. METHODS AND RESULTS: Two hundred eight patients (62±12 years, 138 males) with chronic organic mitral regurgitation referred to surgery underwent an echocardiography and biventricular radionuclide angiography with regional function assessment. Mean RV EF was 40.4±10.2%, ranging from 10% to 65%. RV EF was severely impaired (≤35%) in 63 patients (30%), and biventricular impairment (left ventricular EF<60% and RV EF≤35%) was found in 34 patients (16%). Pathophysiologic correlates of RV EF were left ventricular septal function (ß=0.42, P<0.0001), left ventricular end-diastolic diameter index (ß=-0.22, P=0.002), and pulmonary artery systolic pressure (ß=-0.14, P=0.047). Mitral effective regurgitant orifice size (n=84) influenced RV EF (ß=-0.28, P=0.012). In 68 patients examined after surgery, RV EF increased strongly (27.5±4.3-37.9±7.3, P<0.0001) in patients with depressed RV EF, whereas it did not change in others (P=0.91). RV EF ≤35% impaired 10-year cardiovascular survival (71.6±8.4% versus 89.8±3.7%, P=0.037). Biventricular impairment dramatically reduced 10-year cardiovascular survival (51.9±15.3% versus 90.3±3.2%, P<0.0001; hazard ratio, 5.2; P<0.0001) even after adjustment for known predictors (hazard ratio, 4.6; P=0.004). Biventricular impairment reduced also 10-year overall survival (34.8±13.0% versus 72.6±4.5%, P=0.003; hazard ratio, 2.5; P=0.005) even after adjustment for known predictors (P=0.048). CONCLUSIONS: In patients with organic mitral regurgitation referred to surgery, RV function impairment is frequent (30%) and depends weakly on pulmonary artery systolic pressure but mainly on left ventricular remodeling and septal function. RV function is a predictor of postoperative cardiovascular survival, whereas biventricular impairment is a powerful predictor of both cardiovascular and overall survival.


Assuntos
Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Idoso , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Mortalidade Hospitalar , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prevalência , Prognóstico , Ventriculografia com Radionuclídeos , Taxa de Sobrevida , Sístole , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem
18.
Catheter Cardiovasc Interv ; 83(1): E119-27, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23592336

RESUMO

AIMS: We aimed to determine whether preprocedural analysis of multislice computed tomography (MDCT) scan could accurately predict the "line of perpendicularity" (LP) of the aortic annulus and corresponding C-arm angulations required for prosthesis delivery. METHODS AND RESULTS: A 3D analysis of preprocedural MDCT dedicated to define the LP of the aortic annulus was performed in 60 consecutive patients referred for transcatheter aortic valve replacement (TAVR). In 24 patients, the analysis was performed retrospectively to evaluate reproducibility. In 11 patients of this cohort, additional fluoroscopy and MDCT were performed postprocedure to compare the LP of the aortic annulus and the LP of the implanted bioprosthesis. In 36 patients, the analysis was performed prospectively and the results were available at the time of the procedure. In those 36 patients, the postprocedure fluoroscopy-defined LP of the implanted bioprosthesis was used to validate the LP of the aortic annulus as predicted by MDCT. Intraobserver and interobserver reproducibility of the 3D analysis of MDCT to define the LP of the aortic annulus (κ = 1 and 0.94, respectively) and of the bioprosthesis (κ= 1 and 1, respectively) were excellent. Comparison between the LP of the aortic annulus and the LP of the bioprosthesis showed that the two LPs were virtually identical, demonstrating both self-centering of the device during implantation and the possibility to use the LP of the implanted bioprosthesis as a surrogate of the LP of the aortic annulus. In the prospective cohort, the ability of MDCT analysis to predict the LP of the aortic annulus was very good (accuracy = 94% and κ = 0.89). CONCLUSION: Automated 3D analysis of preimplantation MDCT accurately predicts the LP of the aortic annulus and the corresponding C-arm position required for TAVR.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Interpretação de Imagem Radiográfica Assistida por Computador , Automação , Bioprótese , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
19.
JACC Case Rep ; 29(10): 102319, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38633863

RESUMO

Interventricular septum pellet retention after air-gunshot injury in a persistently asymptomatic patient is a rare, clinically significant occurrence. Management involved monitoring, echocardiography, and computed tomography scans. After risk-benefit analysis, we favored a nonsurgical management without prophylactic antibiotics or colchicine. No post-traumatic pericarditis was observed. Patient remained asymptomatic and in excellent condition at 1-month follow-up.

20.
J Cardiol Cases ; 29(3): 116-119, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481646

RESUMO

We report the case of a redo Ross surgery complicated by an ostial left circumflex occlusion requiring emergent percutaneous coronary intervention. The latter was complicated by coronary perforation treated by two covered stents with V-stenting technique. After immediate success, the clinical course was marked by acute stent thrombosis requiring emergent coronary bypass. Learning objectives: Ostial left circumflex perforation is a rare and potentially fatal complication that is challenging to manage. V stenting technique with two covered stents could be used as a life-saving procedure, but is associated with a high thrombotic risk.