Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(24)2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34960518

RESUMO

Pyroelectrics are a wide class of materials that change their polarization when the system temperature varies. This effect is utilized for a number of different commercial and industrial applications ranging from simple thermal sensors and laser interferometers to water vapor harvesting. Electron paramagnetic resonance (EPR) spectroscopy is a powerful tool for studying the structure and dynamics of materials with unpaired electrons. Since heating accompanies a resonant change of the orientation of electron spins in an external magnetic field, pyroelectrics can be utilized as versatile detectors for so-called indirect detection of the EPR signal. In this work, we investigated three different types of PVDF (polyvinylidene difluoride) standard pyroelectric films with indium tin oxide, Cu/Ni, and Au coatings to determine their sensitivity for detecting EPR signals. All the films were shown to be able to detect the EPR spectra of about 1 µg of a standard stable free radical by heat release. A comparative study based on the calculation of the noise-equivalent power and specific detectivity from experimental spectra showed that the Au coated PVDF film is the most promising active element for measuring the EPR signal. Using the best achieved sensitivity, estimation is given whether this is sufficient for using a PVDF-based pyrodetector for indirectly detecting EPR spectra by recombination heat release or not.


Assuntos
Temperatura Alta , Polivinil , Espectroscopia de Ressonância de Spin Eletrônica , Elétrons , Polímeros de Fluorcarboneto
2.
J Phys Chem A ; 123(2): 505-516, 2019 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-30566354

RESUMO

Magnetic field-affected reaction yield (MARY) spectroscopy is a spin chemistry technique for detecting short-lived radical ions. Having sensitivity to transient species with lifetimes as short as nanoseconds, MARY spectroscopy usually does not provide detailed information on their magnetic resonance parameters, except for simple systems with equivalent magnetic nuclei. In this work, the radical anions of two fluorinated diphenylacetylene derivatives with nonequivalent magnetic nuclei and unknown hyperfine coupling constants ( AHF) were investigated by MARY spectroscopy. The MARY spectra were found to be resolved and have resonance lines in nonzero magnetic fields, which are determined by the AHF values. Simple relationships between the positions of resonance MARY lines and the AHF values were established from the analysis of the different Hamiltonian block contributions to the MARY spectrum. The obtained experimental AHF values are in agreement with the results of quantum chemical calculations at the density functional theory level.

3.
J Phys Chem A ; 122(5): 1235-1252, 2018 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-29283574

RESUMO

Customizable and technology-friendly functional materials are one of the mainstays of emerging organic electronics and optoelectronics. We show that recombination exciplexes of simple substituted diphenylacetylenes with tertiary amines can be a convenient source of tunable deep-blue emission with possible applications in organic electroluminescent systems. The optically inaccessible exciplexes were produced via recombination of radiation-generated radical ion pairs in alkane solution, which mimics charge transport and recombination in the active layer of practical organic light-emitting diodes in a simple solution-based experiment. Despite varying and rather poor intrinsic emission properties, diphenylacetylene and its prototypical methoxy (donor) or trifluoromethyl (acceptor) monosubstituted derivatives readily form recombination exciplexes with N,N-dimethylaniline and other tertiary amines that produce emission with maxima ranging from 385 to 435 nm. The position of emission band maximum linearly correlates with readily calculated gas-phase electron affinity of the corresponding diphenylacetylene, which can be used for fast computational prescreening of the candidate molecules, and various substituted diphenylacetylenes can be synthesized via relatively simple and universal cross-coupling reactions of Sonogashira and Castro. Together, the simple solution-based experiment, computationally cheap prescreening method, and universal synthetic strategy may open a very broad and chemically convenient class of compounds to obtain OLEDs and OLED-based multifunctional devices with tunable emission spectrum and high conversion efficiency that has yet not been seriously considered for these purposes.

4.
Photochem Photobiol Sci ; 15(6): 767-78, 2016 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-27142284

RESUMO

X-irradiation of nonpolar solutions likely provides a possibility to create exciplexes for any donor-acceptor pair that would energetically and sterically allow this. Thorough study and characterization of X-radiation generated exciplexes usually cannot be carried out with conventional methods because of the complex and non-exponential formation and decay dynamics of these species. In this paper, we present a simple and universal experimental approach for the estimation of fluorescence lifetimes (τF) of X-radiation generated exciplexes. The suggested procedure is based on the comparison of quenching of the exciplex emission band and the emission band from a standard luminophore with a known excited state lifetime by dissolved oxygen. Using this approach we report the τF values for two systems with optically inaccessible exciplexes, diphenylacetylene-N,N-dimethylaniline (DMA) and p-terphenyl-DMA, and for two typical exciplex forming systems, naphthalene-DMA and anthracene-DMA. All the found τF values for the X-radiation generated exciplexes lie in the range of 50-70 ns. The accuracy of this approach was checked by time-resolved measurements under X- or near-UV irradiation for those pairs, whose properties make this feasible. The proposed method gives a possibility to avoid a complex numerical evaluation of the non-exponential kinetics of recombination luminescence, and can be used to estimate the characteristic τF values for luminophores and excited complexes formed under X-radiation.


Assuntos
Compostos de Anilina/química , Fluorescência , Raios X , Acetileno/análogos & derivados , Acetileno/química , Alcanos/química , Antracenos/química , Cinética , Naftalenos/química , Oxigênio/química , Processos Fotoquímicos , Soluções/química , Soluções/efeitos da radiação , Compostos de Terfenil/química
5.
Photochem Photobiol Sci ; 13(8): 1169-79, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24926863

RESUMO

X-irradiation of alkane solutions of N,N-dimethylaniline with various organic luminophores produces characteristic emission bands ascribed to the corresponding exciplexes. In contrast to optical generation, which requires diffusion-controlled quenching of excited states, an additional channel of exciplex formation via irreversible recombination of radical ion pairs is operative here, which produces exciplexes in solution with high efficiency even for p-terphenyl and diphenylacetylene having fluorescence decay times of 0.95 ns and 8 ps, respectively. The exciplex emission band is sensitive to an external magnetic field and exerts a very large observed magnetic field effect of up to 20%, the maximum possible value under the conditions of the described experiment.


Assuntos
Alcanos/química , Alcanos/efeitos da radiação , Compostos de Anilina/química , Compostos de Anilina/efeitos da radiação , Fluorescência , Radicais Livres/química , Radicais Livres/efeitos da radiação , Luminescência , Campos Magnéticos , Estrutura Molecular , Naftalenos/química , Naftalenos/efeitos da radiação , Processos Fotoquímicos , Soluções , Espectrometria por Raios X , Raios X
6.
Polymers (Basel) ; 15(20)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37896368

RESUMO

The development of efficient and reliable sensors operating at room temperature is essential to advance the application of terahertz (THz) science and technology. Pyroelectric THz detectors are among the best candidates, taking into account their variety, outstanding performance, ease of fabrication, and robustness. In this work, we compare the performance of six different detectors, based on either LaTiO3 crystal or different polymeric films, using monochromatic radiation of the Novosibirsk Free Electron Laser facility (NovoFEL) in the frequency range of 0.9-2.0 THz. The main characteristics, including noise equivalent power and frequency response, were determined for all of them. Possible reasons for the differences in the obtained characteristics are discussed on the basis of the main physicochemical characteristics and optical properties of the sensitive area. At least three detectors showed sufficient sensitivity to monitor the shape and duration of the THz macropulses utilizing only a small fraction of the THz radiation from the primary beam. This capability is crucial for accurate characterization of THz radiation during the main experiment at various specialized endstations at synchrotrons and free electron lasers. As an example of such characterization, the typical stability of the average NovoFEL radiation power at the beamline of the electron paramagnetic resonance endstation was investigated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA