1.
Rep Pract Oncol Radiother ; 28(5): 671-680, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38179286

RESUMO

Background: The quality of treatment planning for stage III non-small cell lung cancer varies within and between facilities due to the different professions involved in planning. Dose estimation parameters were calculated using a feasibility dose-volume histogram (FDVH) implemented in the treatment planning quality assurance software PlanIQ. This study aimed to evaluate differences in treatment planning between occupations using manual FDVH-referenced treatment planning to identify their characteristics. Materials and methods: The study included ten patients with stage III non-small cell lung cancer, and volumetric-modulated arc therapy was used as the treatment planning technique. Fifteen planners, comprising five radiation oncologists, five medical physicists, and five radiological technologists, developed treatment strategies after referring to the FDVH. Results: Medical physicists had a higher mean dose at D98% of the planning target volume (PTV) and a lower mean dose at D2% of the PTV than those in other occupations. Medical physicists had the lowest irradiation lung volumes (V5 Gy and V13 Gy) compared to other professions, and radiation oncologists had the lowest V20 Gy and mean lung dose. Radiological technologists had the highest irradiation volumes for dose constraints at all indexes on the normal lung volume. Conclusions: The quality of the treatment plans developed in this study differed between occupations due to their background expertise, even when an FDVH was used as a reference. Therefore, discussing and sharing knowledge and treatment planning techniques among professionals is essential to determine the optimal treatment plan for each facility and patient.

2.
J Appl Clin Med Phys ; 23(2): e13505, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34931431

RESUMO

This study aimed to investigate the effect of two different image density adjustment parameters on the results of image matching at six degrees of freedom using radiographic images generated by the ExacTrac X-ray system in brain stereotactic radiosurgery (SRS). This study comprised 32 patients who underwent brain SRS at our hospital from January 2020 to December 2020. In this study, (1) the default parameter (an image density parameter between "tissue" and "bone") was an image density parameter for digitally reconstructed radiograph (DRR) generation used at many facilities, and (2) the bone parameter was the steepest contrast parameter used at our hospital. Of the 32 patients, 24 (75%) had a couch angle of 0.5 mm or more in the translational direction or 0.5° or more in the rotational direction, and 10 (31%) had a couch angle of 1.0 mm or more in the translational direction or 1.0° or more in the rotational direction. Among the 131 cases of all couch angles, 46 (35%) cases had a translational direction of 0.5 mm or more or a rotational direction of 0.5° or more, and 15 (11%) had a translational direction of 1.0 mm or more or a rotational direction of 1.0° or more. The results of this study indicate the usefulness of using appropriate DRR parameters for each case, rather than using the default settings. The use of appropriate DRR parameters can lead to accurate position matching results, leading to fewer image-guided radiation therapy shots and a lower imaging dose.


Assuntos
Radiocirurgia , Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico , Humanos , Radiografia , Planejamento da Radioterapia Assistida por Computador , Raios X
3.
J Appl Clin Med Phys ; 23(8): e13645, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35789532

RESUMO

We aim to evaluate the basic characteristics of SRS MapCHECK (SRSMC) for CyberKnife (CK) and establish a dose verification system using SRSMC for the tumor-tracking irradiation for CK. The field size and angular dependence of SRSMC were evaluated for basic characterization. The output factors (OPFs) and absolute doses measured by SRSMC were compared with those measured using microDiamond and microchamber detectors and those calculated by the treatment planning system (TPS). The angular dependence was evaluated by comparing the SRSMC with a microchamber. The tumor-tracking dose verification system consists of SRSMC and a moving platform. The doses measured using SRSMC were compared with the doses measured using a microchamber and radiochromic film. The OPFs and absolute doses of SRSMC were within ±3.0% error for almost all field sizes, and the angular dependence was within ±2.0% for all incidence angles. The absolute dose errors between SRSMC and TPS tended to increase when the field size was smaller than 10 mm. The absolute doses of the tumor-tracking irradiation measured using SRSMC and those measured using a microchamber agreed within 1.0%, and the gamma pass rates of SRSMC in comparison with those of the radiochromic film were greater than 95%. The basic characteristics of SRSMC for CK presented acceptable results for clinical use. The results of the tumor-tracking dose verification system realized using SRSMC were equivalent to those of conventional methods, and this system is expected to contribute toward improving the efficiency of quality control in many facilities.


Assuntos
Neoplasias , Radiocirurgia , Humanos , Neoplasias/radioterapia , Neoplasias/cirurgia , Radiometria/métodos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
4.
Rep Pract Oncol Radiother ; 27(6): 963-972, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36632304

RESUMO

Background/Aim: The more complex the treatment plan, the higher the possibility of errors in dose verification. Recently, a treatment planning quality assurance (QA) software (PlanIQ) with a function to objectively evaluate the quality of volumetric-modulated arc therapy (VMAT) treatment plans by scoring and calculating the ideal dose-volume histogram has been marketed. This study aimed to assess the association between the scores of ideal treatment plans identified using PlanIQ and the results of dose verification and to investigate whether the results of dose verification can be predicted based on the complexity of treatment plans. Materials and methods: Dose verification was performed using an ionization chamber dosimeter, a radiochromic film, and a three-dimensional dose verification system, Delta4 PT. Correlations between the ideal treatment plan scores obtained by PlanIQ and the results of the absolute dose verification and dose distribution verification were obtained, and it was examined whether dose verifications could be predicted from the complexity of the treatment plans. Results: Even when the score from the ideal treatment plan was high, the results of absolute dose verification and dose distribution verification were sometimes poor. However, even when the score from the ideal treatment plan was low, the absolute volume verification and dose distribution verification sometimes yielded good results. Conclusions: Treatment plan complexity can be determined in advance from the ideal treatment plan score calculated by PlanIQ. However, it is difficult to predict the results of dose verification using an ideal treatment plan.

5.
J Appl Clin Med Phys ; 22(4): 132-142, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33768648

RESUMO

PURPOSE: The purpose of this study was to assess the quality of treatment planning using the PlanIQTM software and to investigate whether it is possible to improve the quality of treatment planning using the "Feasibility dose-volume histogram (DVH)TM " implemented in the PlanIQTM software. METHODS: Using the PlanIQTM software, we retrospectively analyzed the learning curve regarding the quality of the treatment plans for 148 patients of prostate intensity-modulated radiation therapy and volumetric-modulated radiation therapy performed at our institution over the past eight years. We also sought to examine the possibility of improving treatment planning quality by re-planning in 47 patients where the quality of the target dose and the dose limits for organs at risk (OARs) were inadequate. The re-planning treatment plans referred to the Feasibility DVHTM implemented in the PlanIQTM software and modified the treatment planning system based on the target dose and OAR constraints. RESULTS: Analysis of the learning curve of the treatment plans quality using PlanIQTM software retrospectively showed a trend of improvement in the treatment plan quality from year to year. The improvement in the treatment plans quality was more influenced by dose reduction in the OARs than by target coverage. In all cases where re-planning was performed, the improvement in the treatment plan's quality resulted in a better treatment plan than the one adopted for delivery to patients in the clinical plan. CONCLUSIONS: The PlanIQTM provided insights into the quality of the treatment plans at our institution and identified problems and areas for improvement in the treatment plans, allowing for the development of appropriate treatment plans for specific patients.


Assuntos
Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
6.
J Appl Clin Med Phys ; 18(5): 124-133, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28691256

RESUMO

Stereotactic body radiation therapy (SBRT) using recently introduced multileaf collimators (MLC) is preferred over circular collimators in the treatment of localized prostate cancer. The objective of this study was to assess the clinical usefulness of MLCs in prostate SBRT by comparing the effectiveness of treatment plans using fixed collimators, variable collimators, and MLCs and by ensuring delivery quality assurance (DQA) for each. For each patient who underwent conventional radiation therapy for localized prostate cancer, mock SBRT plans were created using a fixed collimator, a variable collimator, and an MLC. The total MUs, treatment times, and dose-volume histograms of the planning target volumes and organs at risk for each treatment plan were compared. For DQA, a phantom with a radiochromic film or an ionization chamber was irradiated in each plan. We performed gamma-index analysis to evaluate the consistency between the measured and calculated doses. The MLC-based plans had an ~27% lower average total MU than the plans involving other collimators. Moreover, the average estimated treatment time for the MLC plan was 31% and 20% shorter than that for the fixed and variable collimator plans respectively. The gamma-index passing rate in the DQA using film measurements was slightly lower for the MLC than for the other collimators. The DQA results acquired using the ionization chamber showed that the discrepancies between the measured and calculated doses were within 3% in all cases. The results reinforce the usefulness of MLCs in robotic radiosurgery for prostrate SBRT treatment planning; most notably, the total MU and treatment time were both reduced compared to the cases using other types of collimators. Moreover, although the DQA results based on film dosimetry yielded a slightly lower gamma-index passing rate for the MLC than for the other collimators, the MLC accuracy was determined to be sufficient for clinical use.


Assuntos
Aceleradores de Partículas , Neoplasias da Próstata/radioterapia , Radiocirurgia/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Procedimentos Cirúrgicos Robóticos/métodos
7.
J Appl Clin Med Phys ; 18(3): 215-220, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28422397

RESUMO

Tungsten functional paper (TFP), which contains 80% tungsten by weight, has radiation-shielding properties. We investigated the use of TFP for the protection of operators during interventional or therapeutic angiography. The air kerma rate of scattered radiation from a simulated patient was measured, with and without TFP, using a water-equivalent phantom and fixed C-arm fluoroscopy. Measurements were taken at the level of the operator's eye, chest, waist, and knee, with a variable number of TFP sheets used for shielding. A Monte Carlo simulation was also utilized to analyze the dose rate delivered with and without the TFP shielding. In cine mode, when the number of TFP sheets was varied through 1, 2, 3, 5, and 10, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.9%, 29.9%, 41.6%, 50.4%, and 56.2%; at chest level, 25.3%, 33.1%, 34.9%, 46.1%, and 44.3%; at waist level, 45.1%, 57.0%, 64.4%, 70.7%, and 75.2%; and at knee level, 2.1%, 2.2%, 2.1%, 2.1%, and 2.1%. In fluoroscopy mode, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.8%, 30.3%, 34.8%, 51.1%, and 58.5%; at chest level, 25.8%, 33.4%, 35.5%, 45.2%, and 44.4%; at waist level, 44.6%, 56.8%, 64.7%, 71.7%, and 77.2%; and at knee level, 2.2%, 0.0%, 2.2%, 2.8%, and 2.5%. The TFP paper exhibited good radiation-shielding properties against the scattered radiation encountered in clinical settings, and was shown to have potential application in decreasing the radiation exposure to the operator during interventional radiology.


Assuntos
Proteção Radiológica/instrumentação , Radiologia Intervencionista/instrumentação , Tungstênio , Fluoroscopia , Humanos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista
8.
Nagoya J Med Sci ; 78(3): 313-21, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27578915

RESUMO

The application of neoadjuvant androgen deprivation (NAD) in prostate cancer leads to a reduction in prostate volume, and the trends in volume reduction differ according to the treatment duration of NAD. A reduction in volume during external beam radiation therapy may lead to the exposure of normal tissues to an unexpected dose. In fact, prostate volume reductions have primarily been reported in European and American institutions. Although the prostate volume of Japanese patients is known to be small, the trends in prostate volume change during radiation therapy remain unclear. In the present study, we aimed to evaluate the changes in prostate volume of Japanese patients during intensity-modulated radiation therapy (IMRT) with NAD. Nineteen Japanese patients with prostate cancer underwent IMRT with NAD. Kilovoltage computed tomography (CT) images were obtained for treatment planning and verification of the treatment position for each treatment fraction. The patients were divided into 3 groups based on the duration of NAD, as follows: NAD < 3 months (short NAD: S-NAD), 3 months ≤ NAD < 6 months (middle NAD: M-NAD), and NAD ≥ 6 months (long NAD: L-NAD). The prostate volume reductions at the 36th treatment fraction, relative to the planning CT, were 7.8%, 2.0%, and 1.7% for the S-NAD, M-NAD, and L-NAD groups, respectively. Prostate volume shrunk greater in the S-NAD group than in the M-NAD and L-NAD groups; this finding was consistent with those of previous studies. The prostate volume changes in Japanese patients were smaller compared to those in European and American patients.


Assuntos
Terapia Neoadjuvante , Antagonistas de Androgênios , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Estudos Retrospectivos
9.
J Appl Clin Med Phys ; 17(1): 234-245, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894359

RESUMO

Metal dental restoration materials cause dose enhancement upstream and dose disturbance downstream of the high-density inhomogeneous regions in which these materials are used. In this study, we evaluated the impact of a dental metallic crown (DMC) on intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for head and neck cancer. Additionally, the possibility of sparing the oral mucosa from dose enhancement using an individual intraoral mouthpiece was evaluated. An experimental oral phantom was designed to verify the dosimetric impact of a DMC. We evaluated the effect on single beam, parallel opposing beam, arc beam, IMRT, and VMAT treatment plans. To evaluate the utility of a 3-mm-thick intraoral mouthpiece, the doses across the mouthpiece were measured. For single beam irradiation, the measured doses at the entrance and exit planes of the DMC were 51% higher and 21% lower than the calculated dose by the treatment planning system, respectively. The maximum dose enhancements were 22% and 46% for parallel opposing beams and the 90° arc rotation beam, respectively. For IMRT and VMAT, the measured doses adjacent to the DMC were 12.2% ± 6.3% (mean ± 1.96SD) and 12.7% ± 2.5% higher than the calculated doses, respectively. With regard to the performance of the intraoral mouthpiece for the IMRT and VMAT cases, the disagreement between measured and calculated doses at the outermost surface of the mouthpieces were -2.0%, and 2.0%, respectively. Dose enhancements caused by DMC-mediated radiation scattering occurred during IMRT and VMAT. Because it is difficult to accurately estimate the dose perturbations, careful consideration is necessary when planning head and neck cancer treatments in patients with DMCs. To spare the oral mucosa from dose enhancement, the use of an individual intraoral mouthpiece should be considered.


Assuntos
Coroas/efeitos adversos , Neoplasias de Cabeça e Pescoço/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Boca/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
10.
Radiol Phys Technol ; 17(1): 337-345, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37938420

RESUMO

This study devised a method to efficiently launch the RapidPlan model for volumetric-modulated arc therapy for prostate cancer in small- and medium-sized facilities using high-quality treatment plans with the PlanIQ software as a reference. Treatment plans were generated for 30 patients with prostate cancer to construct the RapidPlan model using PlanIQ as a reference. In the context of PlanIQ-referenced treatment planning, treatment plans were developed, such that the feasibility dose-volume histogram of each organ-at-risk fell within F ≤ 0.1. For validation of the RapidPlan model, treatment plans were formulated for 20 patients using both RapidPlan and PlanIQ, and the differences were evaluated. The results of RapidPlan model validity assessment revealed that the RapidPlan-produced treatment plans exhibited higher quality in 11 of 20 patients. No significant differences were found between the treatment plans. In conclusion, high-quality treatment plans formulated using PlanIQ as reference facilitated efficient implementation of RapidPlan modeling.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Software , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Órgãos em Risco
11.
Med Dosim ; 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38556402

RESUMO

The increase in high-precision radiation therapy, particularly volumetric-modulated arc therapy (VMAT), has increased patient numbers and expanded treatment sites. However, a significant challenge in VMAT treatment planning is the inconsistent plan quality among different planners and facilities. This study explored the use of dose-volume histogram (DVH) prediction tools to address these disparities, specifically focusing on RapidPlan (Varian Medical Systems) and PlanIQ (Sun Nuclear). RapidPlan predicts achievable DVHs and automatically generates optimization objectives. While it has demonstrated organ-at-risk (OAR) dose reduction benefits, the quality of the plan used to build its model significantly affects its predictions. On the other hand, PlanIQ offers ease of use and does not require prior model-building. Five planners participated in this study, each creating two treatment plans: one referencing RapidPlan and the other using PlanIQ. The planners had the freedom to adjust parameters while referencing the DVH predictions. The plans were evaluated using "Plan Quality Metric" (PQM) scores to assess the planning target volume excluding the rectum and OARs. The results revealed that RapidPlan-referenced plans often outperformed PlanIQ-based plans, with less interplanner variability. PlanIQ played a pivotal role in the construction of the RapidPlan model. This study is the first to compare plans generated by multiple planners using both tools. This study provides insights into optimizing treatment planning by considering the characteristics of both RapidPlan and PlanIQ.

12.
J Radiat Res ; 65(1): 1-9, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-37996085

RESUMO

This review provides an overview of the application of artificial intelligence (AI) in radiation therapy (RT) from a radiation oncologist's perspective. Over the years, advances in diagnostic imaging have significantly improved the efficiency and effectiveness of radiotherapy. The introduction of AI has further optimized the segmentation of tumors and organs at risk, thereby saving considerable time for radiation oncologists. AI has also been utilized in treatment planning and optimization, reducing the planning time from several days to minutes or even seconds. Knowledge-based treatment planning and deep learning techniques have been employed to produce treatment plans comparable to those generated by humans. Additionally, AI has potential applications in quality control and assurance of treatment plans, optimization of image-guided RT and monitoring of mobile tumors during treatment. Prognostic evaluation and prediction using AI have been increasingly explored, with radiomics being a prominent area of research. The future of AI in radiation oncology offers the potential to establish treatment standardization by minimizing inter-observer differences in segmentation and improving dose adequacy evaluation. RT standardization through AI may have global implications, providing world-standard treatment even in resource-limited settings. However, there are challenges in accumulating big data, including patient background information and correlating treatment plans with disease outcomes. Although challenges remain, ongoing research and the integration of AI technology hold promise for further advancements in radiation oncology.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Radioterapia Guiada por Imagem , Humanos , Inteligência Artificial , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias/radioterapia , Radioterapia (Especialidade)/métodos
13.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(11): 1250-60, 2013 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-24256648

RESUMO

The purpose of this study was to clinically evaluate the automatic outline extraction properties using general-purpose deformable image registration (DIR) software for the head and neck region. To this end, we evaluated the following: (1) the difference between manual outline extraction carried out by a radiation therapy specialist and automatic outline extraction using the DIR software, and (2) the precision of the automatic outline extraction for the diachronic figure change and change in the organ shape. The manually-extracted outline and that extracted using the DIR software closely resembled each other at 0.70. Further, in the same case, the automatic outline extraction precision of the DIR software was greater at about 0.80. Our findings suggest DIR software to be useful for lessening the work involved in outline extraction.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Pessoa de Meia-Idade
14.
Cureus ; 15(7): e42299, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37609081

RESUMO

The criteria for indication of salvage stereotactic radiosurgery (SRS) for local progression following multi-fraction (mf) SRS of brain metastases (BMs) remain controversial, along with the optimal planning scheme. Herein, we described a case of BMs from pan-negative lung adenocarcinoma (LAC), in which the two lesions of local progression following initial eight-fraction (8-fr) SRS were re-treated with 5-fr SRS with the biologically effective dose (BED10) of ≥80 Gy, based on the linear-quadratic (LQ) formula with an alpha/beta ratio of 10. The re-SRS resulted in the alleviation of symptoms and favorable tumor responses with minimal adverse effects during the 7.3-month follow-up. In the lesions of local progression, the gross tumor volume (GTV) coverage with 49.6 Gy (BED10 80 Gy) was generally insufficient, and the GTV dose wes relatively homogeneous with ≥87% isodose covering. In contrast, the 5-fr re-SRS was performed with sufficient GTV coverage with ≤68% isodose of 43 Gy (BED10 80 Gy). Taken together, sufficient GTV coverage with a BED10 of ≥80 Gy and steep dose increase inside the GTV boundary, that is, extremely inhomogeneous GTV dose, are important in 8-fr SRS for ensuring excellent local control of BMs from pan-negative LAC. For local progression following mfSRS that does not fulfill both criteria, re-SRS with the above planning scheme can be an efficacious and safe treatment option for at least six months, especially in cases in which the prior SRS was performed with a dose/fractionation under adequate consideration of brain tolerance. The BED10 seems to be the most suitable for estimating the anti-tumor efficacies of SRS doses in 3-8 fr, similar to that of a single fraction of 24 Gy.

15.
Cureus ; 15(1): e33411, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36751179

RESUMO

Stereotactic radiosurgery (SRS) with >5 fraction (fr) has been increasingly adopted for brain metastases (BMs), given the current awareness of limited brain tolerance for ≤5 fr. The target volume/configuration change and/or deviation within the cranium during fractionated SRS can be unpredictable and critical uncertainties affecting treatment accuracy, plus the effect of these events on the long-term outcome remains uncertain. Herein, we describe a case of two challenging BMs treated by 10 fr SRS with a unique dose-gradient optimization strategy, in which the large cystic tumor revealed an intriguing correlation of such inter-fractional change with late radiographic sequela, suggesting a dose threshold for attaining long-term local tumor control and being immune to symptomatic brain necrosis. A 63-year-old man presented with two cystic lesions located in the left parietal lobe (19.9 cm3) and pons (1.1 cm3) one month after surgery for esophageal squamous cell carcinoma. The principles for 10 fr SRS were as follows: (1) very inhomogeneous gross tumor volume (GTV) dose covered by 53 Gy, biologically effective dose with an alpha/beta ratio of 10 (BED10) of ≥80 Gy; (2) moderate dose spillage margin outside the GTV boundary: 2-2.5 mm outside the GTV margin was covered by 37 Gy, BED10 of ≈50 Gy; (3) concentrically-laminated, steep dose increase inside the GTV boundary: 2 mm inside the GTV margin was covered by ≥62 Gy, BED10 of ≥100 Gy. At the completion of SRS, the parietal lesion showed significant shrinking and dorsomedial shifting with slight evisceration of the GTV, followed by marked regression of the parietal lesion within four months. At 13.5 months, a cystic change was noted at the dorsal part of the remnant. At 16.7 months, ventral enhancement gradually expanded without enlargement of the dorsal cystic component. On the T2-weighted images, the dorsal low-intensity remnant and ventral iso-intensity blurry-demarcated component were contrasting. Pathological examinations during and after lesionectomy at 17.4 months revealed necrosis only. At 30.5 months, the patient had a left visual field defect without recurrence. In contrast, the pons lesion showed no notable change during 10 fr SRS and nearly complete remission over six months with its sustainment without radiation injury at 30.5 months. Taken together, 10 fr SRS with a sufficient BED10 can provide superior tumor response and safety for BM that is not amenable to ≤5 fr SRS. Although a very inhomogeneous GTV dose can contribute to early and adequate tumor shrinkage and subsequent local tumor eradication, significant tumor shrinkage during fractionated SRS (fSRS) inevitably results in unnecessary higher dose exposure to the surrounding brain, which could lead to late radiation injury requiring intervention. The optimum dose should be determined through further investigation, in consideration of the dynamic and unpredictable nature of the actual absorbed doses to both the tumor and the surrounding brain.

16.
Cureus ; 15(5): e38645, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37284398

RESUMO

Five-fraction (fr) stereotactic radiosurgery (SRS) is increasingly being applied to large brain metastases (BMs) >2-3 cm in diameter, for which 30-35 Gy is the commonly prescribed dose. Since 2018, to further enhance both safety and efficacy, we have limited the five-fr SRS to approximately ≤3 cm BMs and adopted our own modified dose prescription and distribution: 43 and 31 Gy cover the boundaries of the gross tumor volume (GTV) and 2 mm outside the GTV, respectively, along with a steep dose increase inside the GTV boundary, that is, an intentionally very inhomogeneous GTV dose. Herein, we describe a case of symptomatic BM treated with five-fr SRS using the above policy, which resulted in a maximum tumor response with nearly complete remission (nCR) followed by gradual tumor regrowth despite obvious tumor shrinkage during irradiation. A 71-year-old man who had previously undergone surgery for squamous cell carcinoma (SCC) of the lungs presented with right-sided hemiparesis attributed to the para-falcine BM (27 mm in maximum diameter, 5.38 cm3). The BM was treated with five-fr SRS, with 99.2% of the GTV covered with 43 Gy and 59% isodose. Neurological symptoms improved during SRS, and obvious tumor shrinkage and mitigation of perilesional edema were observed upon completion of SRS. No subsequent anti-cancer pharmacotherapy was administered due to idiopathic pulmonary fibrosis (IPF). Despite a maximum response with nCR at four months, the tiny residual enhancing lesion gradually enlarged from 7.7 months to 22.7 months without neurological worsening. Although a consistent T1/T2 mismatch suggested the dominance of brain radionecrosis, 11C-methionine positron emission tomography showed increased uptake in the enhancing lesion. Pathological examination after total lesionectomy at 24.6 months revealed viable tumor tissue. Post-SRS administration of nintedanib for IPF may have provided some anti-tumor efficacy for lung SCC and may mitigate the adverse effects of SRS. The present case suggests that even ≥43 Gy with ≤60% isodose to the GTV boundary and ≥31-35 Gy to the 2 mm outside the GTV are insufficient to achieve long-term local tumor control by five-fr SRS alone in some large BM from lung SCC.

17.
Nagoya J Med Sci ; 85(3): 504-517, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37829483

RESUMO

Prostatic urethra identification is crucial in prostate stereotactic body radiotherapy (SBRT) to reduce the risk of urinary toxicity. Although computed tomography (CT) with a catheter is commonly employed, it is invasive, and catheter placement may displace the urethral position, resulting in possible planning inaccuracies. However, magnetic resonance imaging (MRI) can overcome these weaknesses. Accurate urethral identification and minimal daily variation could ensure a highly accurate SBRT. In this study, we investigated the usefulness of a three-dimensional (3D) T2-weighted (T2W) sequence for urethral identification, and the interfractional motion of the prostatic urethra on CT with a catheter and MRI without a catheter for implementing noninvasive SBRT. Thirty-two patients were divided into three groups. The first group underwent MRI without a catheter to evaluate urethral identification by two-dimensional (2D)- and 3D-T2W sequences using mean slice-wise Hausdorff distance (MSHD) and Dice similarity coefficient (DSC) of the contouring by two operators and using visual assessment. The second group provided 3-day MRI data without a catheter using 3D-T2W, and the third provided 3-day CT data with a catheter to evaluate the interfractional motion using MSHD, DSC, and displacement distance (Dd). The MSHD and DSC for the interoperator variability in urethral identification and visual assessment were superior in 3D-T2W than in 2D-T2W. Regarding interfractional motion, the Dd value for prostatic urethra was smaller in MRI than in CT. These findings indicate that the 3D-T2W yielded adequate prostatic urethral identification, and catheter-free MRI resulted in less interfractional motion, suggesting that 3D-T2W MRI without a catheter is a feasible noninvasive approach to performing prostate SBRT.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Radiocirurgia/métodos , Uretra/diagnóstico por imagem , Uretra/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Imageamento por Ressonância Magnética/métodos
18.
Igaku Butsuri ; 43(1): 1-16, 2023.
Artigo em Japonês | MEDLINE | ID: mdl-37045758

RESUMO

This technical report provides useful information on the current status and issues of quality control in 125I seed source strength measurement for Permanent Prostate Brachytherapy in Japan.With the spread of 125I seed brachytherapy, the traceability of source strength measurements with the single-seed assay was established in Japan. This allows medical facilities to measure reference air kerma rate of 125I seeds with their own well-type of ionization chamber. However, it is difficult to maintain the traceability chain because the 125I reference air kerma rate standards have been hardly utilized by medical facilities so far. Meanwhile, some serious incidents of contamination of the different source strengths and dead seeds were reported in Japan.To address the specific issues in Japan, JASTRO Brachytherapy Subcommittee established a working group (WG) in 2021. The goal of this WG is to investigate the management methods of source strength measurement used in medical facilities, and to discuss the ideal and practicable methods of source management such as verifying the number of seeds and source strength. Initially, a questionnaire survey was conducted to facilities offering 125I seed brachytherapy in Japan. Sixty-seven out of 95 facilities responded (response rate 70.5%). This survey revealed that 41% of facilities did not perform either confirmation of the number of seeds or measurement of source strength. There are several reasons why the source strength was not measured in those facilities. For example, 125I seeds are provided under the sterilized conditions; quality assurance by source suppliers is reliable; and there is not sufficient staff.The single-seed assay is regarded as an internationally standardized and the most reliable measurement method. Therefore, it is an essential measurement technique to ensure traceability of source strength measurements. However, our survey found that most Japanese facilities do not perform single-seed assays. Meanwhile, some facilities have performed batch assay as an alternative method, in which all of the multiple sources in a batch are measured while loaded into sterilized cartridges. Although the measurement by the batch assay is less accurate than the one by the single-seeded assay, the batch assay does not require re-sterilization of the source and can be performed quickly. It might be useful to detect unexpected errors such as differences in the number of sources and abnormalities in source strength.In this report, we will introduce several methods of source strength measurement that have been implemented in medical facilities. The quality assurance of 125I seed sources in prostate interstitial brachytherapy should be provided not only by the source suppliers but also by the medical facilities that use sources to treat patients. We hope that medical facilities will refer to this technical report and use it as an aid to quality assurance in their own facilities.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Braquiterapia/métodos , Próstata , Dosagem Radioterapêutica , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Próstata/radioterapia
19.
F1000Res ; 12: 798, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38204487

RESUMO

Background: Currently, the standard curative treatment for ventricular tachycardia (VT) and ventricular fibrillation (VF) is radiofrequency catheter ablation. However, when the VT circuit is deep in the myocardium, the catheter may not be delivered, and a new, minimally invasive treatment using different energies is desired. Methods: This is a protocol paper for a feasibility study designed to provide stereotactic radiotherapy for refractory VT not cured by catheter ablation after at least one catheter ablation. The primary end point is to evaluate the short-term safety of this treatment and the secondary endpoint is to evaluate its efficacy as assessed by the reduction in VT episode. Cyberknife M6 radiosurgery system will be used for treatment, and the prescribed dose to the target will be 25Gy in one fraction. The study will be conducted on three patients. Conclusion: Since catheter ablation is the only treatment option for VT that is covered by insurance in Japan, there is currently no other treatment for VT/VF that cannot be cured by catheter ablation. We hope that this feasibility study will provide hope for patients who are currently under the stress of ICD activation. Trial registration: The study has been registered in the Japan Registry of Clinical Trials (jRCTs042230030).


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Catéteres , Japão , Miocárdio , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Ensaios Clínicos como Assunto
20.
Nagoya J Med Sci ; 84(2): 477-483, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35967941

RESUMO

With the widespread use of three-dimensional printers, organ models created by these printers are now being used in the medical field for preoperative planning of surgeries. In this article, we report two cases in which embolization was expected to be difficult, and the three-dimensional printer-based vascular modeling was helpful in planning the surgery. The first case involved an aneurysm of the splenic artery. We attempted to embolize the aneurysm but were unable to advance the catheter into the distal artery and discontinued the procedure. The second case was a perianal varicose vein, which was initially treated with percutaneous transhepatic obliteration but was recanalized and required embolization. However, we expected difficulty in selecting the inferior mesenteric vein. In both cases, the vascular models were created using a 3D printer from the patients' computed tomography images. Preoperative planning, including treatment simulation, was based on these models. The time required to print a three-dimensional vascular model was approximately 12 hours at a cost of less than $10 each. Patient-specific vascular models using a three-dimensional printer can be a simple and inexpensive tool that can increase the success of embolization in difficult cases.


Assuntos
Aneurisma , Embolização Terapêutica , Catéteres , Humanos , Impressão Tridimensional , Tomografia Computadorizada por Raios X/métodos