1.
J Chromatogr A ; 993(1-2): 179-85, 2003 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-12735451

RESUMO

Morin was used as a pre-column reagent for the determination of aluminum by RP-HPLC with fluorescence detection. This method has been successfully applied to direct determination of trace Al in environmental and biological samples. The response was linear from 6 x 10(-9) to 6 x 10(-5) M with a detection limit of 2 x 10(-9) M. In addition, the different Al complexes with morin were separated by the proposed HPLC procedure and their coordination ratios were depicted by molar-ratio method. The results showed that 1:1 and 2:1 Al-morin complexes formed.


Assuntos
Alumínio/análise , Cromatografia Líquida de Alta Pressão/métodos , Poluentes Ambientais/análise , Flavonoides/química , Espectrometria de Fluorescência
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(11): 1391-4, 2004 Nov.
Artigo em Zh | MEDLINE | ID: mdl-15762485

RESUMO

Fluorimetric method has been proposed for the speciation of Al in natural waters, based on the different competitive complexation behavior of analytical reagent and natural organic matter to Al. With eriochrome blue black R (EBBR) or morin, the monomeric inorganic Al (Al(i)) was determined, while with 8-hydroxylquinoline, the total monomeric Al (Al(a)) was obtained. The analytical results of Al speciation in natural water are close to those by Driscoll's method. The method is simple and reliable. Fractionation of Al was realized by selecting appropriate reagents under the pH of natural water determined. The merits of this novel strategy are that the disturbance to original equilibrium of Al species is minimized and the results conform to the actual situation of natural waters.


Assuntos
Alumínio/isolamento & purificação , Fluorometria/métodos , Água/química , Fracionamento Químico , Água Doce/química , Poluentes Químicos da Água/isolamento & purificação , Purificação da Água
3.
Anal Bioanal Chem ; 376(4): 542-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12739101

RESUMO

A reversed-phase high-performance liquid chromatographic method with fluorescence detection for the determination of labile monomeric aluminium has been developed through pre-column complexation using morin as the analytical reagent. The highly fluorescent aluminium-morin complex (excitation wavelength 418 nm, emission wavelength 490 nm) was separated on a Spherisorb ODS 2 column with an eluent consisting of 30% methanol and 70% water (pH 1.0 with perchloric acid). The most remarkable point of this protocol was that only the most toxic aluminium species, that is, free aqua-aluminium ion and its monomeric hydroxo complex ions, selectively respond among various aluminium complexes. This strategy has been successfully applied to direct fractionation of the toxic aluminium in natural waters and biological samples without any pretreatment.


Assuntos
Alumínio/isolamento & purificação , Flavonoides/química , Poluentes Químicos da Água/isolamento & purificação , Alumínio/sangue , Alumínio/líquido cefalorraquidiano , Alumínio/urina , Cromatografia Líquida de Alta Pressão , Fluorescência , Água Doce/análise , Humanos , Indicadores e Reagentes/química , Sensibilidade e Especificidade , Chá/química , Poluentes Químicos da Água/sangue , Poluentes Químicos da Água/líquido cefalorraquidiano , Poluentes Químicos da Água/urina