RESUMO
Hyaluronic acid (HA) is ubiquitously found in biological tissues and mediates wound healing mechanisms after injury by promoting cell migration and proliferation. With the development of tissue-engineered neural therapeutics, including off-the-shelf grafts for peripheral nerve repair, HA is an attractive material for clinical use because of its various biological roles. HA-based biomaterials have been carefully engineered to elicit specific in vivo host responses, however an important design feature that should be considered in these scaffolds is endogenous degradation. Hyaluronidases (HYALs) are the complementary enzymes that are responsible for HA turnover. Although HYAL expression has been widely characterized in various tissues, including the central nervous system, and for different pathologies, there remains a lack of knowledge of HYAL mediated turnover in peripheral nerve tissue. In this work, gene expression of two hyaluronidases, HYAL1 and HYAL2, and HA-binding receptor, CD44, were studied in two injury models: rat sciatic nerve crush and critical gap transection. HYAL2 and CD44 were shown to be upregulated 3 days after crush injury, whereas HYAL1 was upregulated at 3 weeks, which collectively demonstrate temporal patterning of HA breakdown. Additionally, differences were observed between HYAL and HA expression at 3 weeks when compared for both nerve injury models. The activity of HYAL in peripheral nerve tissue was determined to be approximately 0.11 µmol/min, which could be used to further model HA-based biomaterial breakdown for peripheral nerve applications. Overall, this work provides a landscape of HA turnover in peripheral nerve that can be used for future neural applications.
Assuntos
Traumatismos dos Nervos Periféricos , Animais , Ratos , Traumatismos dos Nervos Periféricos/genética , Hialuronoglucosaminidase/genética , Nervo Isquiático , Materiais Biocompatíveis , Movimento Celular , Ácido HialurônicoRESUMO
Every year, there are approximately 500 000 peripheral nerve injury (PNI) procedures due to trauma in the US alone. Autologous and acellular nerve grafts are among current clinical repair options; however, they are limited largely by the high costs associated with donor nerve tissue harvesting and implant processing, respectively. Therefore, there is a clinical need for an off-the-shelf nerve graft that can recapitulate the native microenvironment of the nerve. In our previous work, we created a hydrogel scaffold that incorporates mechanical and biological cues that mimic the peripheral nerve microenvironment using chemically modified hyaluronic acid (HA). However, with our previous work, the degradation profile and cell adhesivity was not ideal for tissue regeneration, in particular, peripheral nerve regeneration. To improve our previous hydrogel, HA was conjugated with fibrinogen using Michael-addition to assist in cell adhesion and hydrogel degradability. The addition of the fibrinogen linker was found to contribute to faster scaffold degradation via active enzymatic breakdown, compared to HA alone. Additionally, cell count and metabolic activity was significantly higher on HA conjugated fibrinogen compared previous hydrogel formulations. This manuscript discusses the various techniques deployed to characterize our new modified HA fibrinogen chemistry physically, mechanically, and biologically. This work addresses the aforementioned concerns by incorporating controllable degradability and increased cell adhesivity while maintaining incorporation of hyaluronic acid, paving the pathway for use in a variety of applications as a multi-purpose tissue engineering platform.
Assuntos
Engenharia Tecidual , Engenharia Tecidual/métodos , Hidrogéis/química , Ácido Hialurônico/química , Fibrinogênio/química , Animais , Ratos , Linhagem CelularRESUMO
Objective. Although neural-enabled prostheses have been used to restore some lost functionality in clinical trials, they have faced difficulty in achieving high degree of freedom, natural use compared to healthy limbs. This study investigated thein vivofunctionality of a flexible and scalable regenerative peripheral-nerve interface suspended within a microchannel-embedded, tissue-engineered hydrogel (the magnetically aligned regenerative tissue-engineered electronic nerve interface (MARTEENI)) as a potential approach to improving current issues in peripheral nerve interfaces.Approach. Assembled MARTEENI devices were implanted in the gaps of severed sciatic nerves in Lewis rats. Both acute and chronic electrophysiology were recorded, and channel-isolated activity was examined. In terminal experiments, evoked activity during paw compression and stimulus response curves generated from proximal nerve stimulation were examined. Electrochemical impedance spectroscopy was performed to assess the complex impedance of recording sites during chronic data collection. Features of the foreign-body response (FBR) in non-functional implants were examined using immunohistological methods.Main results. Channel-isolated activity was observed in acute, chronic, and terminal experiments and showed a typically biphasic morphology with peak-to-peak amplitudes varying between 50 and 500µV. For chronic experiments, electrophysiology was observed for 77 days post-implant. Within the templated hydrogel, regenerating axons formed minifascicles that varied in both size and axon count and were also found to surround device threads. No axons were found to penetrate the FBR. Together these results suggest the MARTEENI is a promising approach for interfacing with peripheral nerves.Significance. Findings demonstrate a high likelihood that observed electrophysiological activity recorded from implanted MARTEENIs originated from neural tissue. The variation in minifascicle size seen histologically suggests that amplitude distributions observed in functional MARTEENIs may be due to a combination of individual axon and mini-compound action potentials. This study provided an assessment of a functional MARTEENI in anin vivoanimal model for the first time.
Assuntos
Nervos Periféricos , Nervo Isquiático , Animais , Axônios/fisiologia , Eletrônica , Hidrogéis , Regeneração Nervosa/fisiologia , Nervos Periféricos/fisiologia , Ratos , Ratos Endogâmicos Lew , Nervo Isquiático/fisiologiaRESUMO
Peripheral nerve injuries can be debilitating to motor and sensory function, with severe cases often resulting in complete limb amputation. Over the past two decades, prosthetic limb technology has rapidly advanced to provide users with crude motor control of up to 20° of freedom; however, the nerve-interfacing technology required to provide high movement selectivity has not progressed at the same rate. The work presented here focuses on the development of a magnetically aligned regenerative tissue-engineered electronic nerve interface (MARTEENI) that combines polyimide "threads" encapsulated within a magnetically aligned hydrogel scaffold. The technology exploits tissue-engineered strategies to address concerns over traditional peripheral nerve interfaces including poor axonal sampling through the nerve and rigid substrates. A magnetically templated hydrogel is used to physically support the polyimide threads while also promoting regeneration in close proximity to the electrode sites on the polyimide. This work demonstrates the utility of magnetic templating for use in tuning the mechanical properties of hydrogel scaffolds to match the stiffness of native nerve tissue while providing an aligned substrate for Schwann cell migration in vitro. MARTEENI devices were fabricated and implanted within a 5-mm-long rat sciatic-nerve transection model to assess regeneration at 6 and 12 weeks. MARTEENI devices do not disrupt tissue remodeling and show axon densities equivalent to fresh tissue controls around the polyimide substrates. Devices are observed to have attenuated foreign-body responses around the polyimide threads. It is expected that future studies with functional MARTEENI devices will be able to record and stimulate single axons with high selectivity and low stimulation regimes.
Assuntos
Regeneração Nervosa , Tecido Nervoso , Animais , Axônios , Eletrônica , Ratos , Células de Schwann , Nervo Isquiático , Engenharia TecidualRESUMO
Peripheral nerve injury can result in debilitating outcomes including loss of function and neuropathic pain. Although nerve repair research and therapeutic development are widely studied, translation of these ideas into clinical interventions has not occurred at the same rate. At the turn of this century, approaches to peripheral nerve repair have included microsurgical techniques, hollow conduits, and autologous nerve grafts. These methods provide satisfactory results; however, they possess numerous limitations that can prevent effective surgical treatment. Commercialization of Avance, a processed nerve allograft, sought to address limitations of earlier approaches by providing an off-the-shelf alternative to hollow conduits while maintaining many proregenerative properties of autologous grafts. Since its launch in 2007, Avance has changed the landscape of the nerve repair market and is used to treat tens of thousands of patients. Although Avance has become an important addition to surgeon and patient clinical options, the product's journey from bench to bedside took over 20 years with many research and commercialization challenges. This article reviews the events that have brought a processed nerve allograft from the laboratory bench to the patient bedside. Additionally, this review provides a perspective on lessons and considerations that can assist in translation of future medical products.