1.
Radiographics ; 41(1): 224-248, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33216673

RESUMO

Radiation therapy (RT) continues to play a central role as an effective therapeutic modality for a variety of tumors and vascular malformations in the central nervous system. Although the planning and delivery techniques of RT have evolved substantially during the past few decades, the structures surrounding the target lesion are inevitably exposed to radiation. A wide variety of radiation-induced changes may be observed at posttreatment imaging, which may be confusing when interpreting images. Histopathologically, radiation can have deleterious effects on the vascular endothelial cells as well as on neuroglial cells and their precursors. In addition, radiation induces oxidative stress and inflammation, leading to a cycle of further cellular toxic effects and tissue damage. On the basis of the time of expression, radiation-induced injury can be divided into three phases: acute, early delayed, and late delayed. Acute and early delayed injuries are usually transient and reversible, whereas late delayed injuries are generally irreversible. The authors provide a comprehensive review of the timeline and expected imaging appearances after RT, including the characteristic imaging features after RT with concomitant chemotherapy. Specific topics discussed are imaging features that help distinguish expected posttreatment changes from recurrent disease, followed by a discussion on the role of advanced imaging techniques. Knowledge of the RT plan, the amount of normal structures included, the location of the target lesion, and the amount of time elapsed since RT is highly important at follow-up imaging, and the reporting radiologist should be able to recognize the characteristic imaging features after RT and differentiate these findings from tumor recurrence. ©RSNA, 2020.


Assuntos
Células Endoteliais , Lesões por Radiação , Sistema Nervoso Central , Diagnóstico por Imagem , Humanos , Lesões por Radiação/diagnóstico por imagem
2.
Radiographics ; 38(2): 450-461, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29528826

RESUMO

Artifacts caused by metallic implants appear as dark and bright streaks at computed tomography (CT), which severely degrade the image quality and decrease the diagnostic value of the examination. When x-rays pass through a metal object, depending on its size and composition, different physical effects negatively affect the measurements in the detector, most notably the effects of photon starvation and beam hardening. To improve image quality and recover information about underlying structures, several artifact reduction methods have been introduced in modern CT systems. Projection-based metal artifact reduction (MAR) algorithms act in projection space and replace corrupted projections caused by metal with interpolation from neighboring uncorrupted projections. MAR algorithms primarily suppress artifacts that are due to photon starvation. The dual-energy CT technique is characterized by data acquisition at two different energy spectra. Dual-energy CT provides synthesized virtual monochromatic images at different photon energy (kiloelectron volt) levels, and virtual monochromatic images obtained at high kiloelectron volt levels are known to reduce the effects of beam hardening. In clinical practice, although MAR algorithms can be applied after image acquisition, the decision whether to apply dual-energy CT for the patient usually needs to be made before image acquisition. Radiologists should be more familiar with the clinical and technical features of each method and should be able to choose the optimal method according to the clinical situation. ©RSNA, 2018.


Assuntos
Artefatos , Metais , Próteses e Implantes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos
3.
Neuroradiology ; 60(11): 1141-1150, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30143820

RESUMO

PURPOSE: To evaluate the effects of the single-energy metal artifact reduction (SEMAR) algorithm on image quality of cerebral CT and CT angiography (CTA) for patients who underwent intracranial aneurysm coiling. METHODS: Twenty patients underwent cerebral CT and CTA using a 320-detector row CT after intracranial aneurysm coiling. Images with and without application of the SEMAR algorithm (SEMAR CT and standard CT images, respectively) were reconstructed for each patient. The images were qualitatively assessed by two independent radiologists in a blinded manner for the depiction of anatomical structures around the coil, delineation of the arteries around the coil, and the depiction of the status of coiled aneurysms. Artifact strength was quantitatively assessed by measuring the standard deviation of attenuation values around the coil. RESULTS: The strength of artifacts measured in SEMAR CT images was significantly lower than that in standard CT images (25.7 ± 10.2 H.U. vs. 80.4 ± 67.2 H.U., p < 0.01, Student's paired t test). SEMAR CT images were significantly improved compared with standard CT images in the depiction of anatomical structures around the coil (p < 0.01, the sign test), delineation of the arteries around the coil (p < 0.01), and the depiction of the status of coiled aneurysms (p < 0.01). CONCLUSION: The SEMAR algorithm significantly reduces metal artifacts from intracranial aneurysm coiling and improves visualization of anatomical structures and arteries around the coil, and depiction of the status of coiled aneurysms on post-interventional cerebral CT.


Assuntos
Algoritmos , Artefatos , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Acta Radiol ; 58(9): 1085-1093, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28068822

RESUMO

Background Abdominal computed tomography (CT) without arm elevation is associated with degraded image quality due to streak artifacts. Purpose To compare the degree of streak artifacts in abdominal CT images without arm elevation between full iterative reconstruction (IR), hybrid IR, and filtered back projection (FBP) using two commercially available scanners. Material and Methods First, a phantom study simulating CT examination without arm elevation was performed. Second, unenhanced axial images of 33 patients (17 and 16 patients for each vendor) who underwent CT without arm elevation were reconstructed with full IR, hybrid IR and FBP. A radiologist placed 50 parallel lines with lengths of 50 pixels vertical to the streaks and quantitatively evaluated the images for streak artifacts in the phantom study. Two radiologists evaluated the images of patients for streak artifacts (on the liver and the kidney) and diagnostic acceptability using a four-point scale. Results The phantom study indicated that full IR algorithms were more effective than FBP in reducing streak artifacts. In the clinical patient study, streak artifacts were significantly more reduced with full IR compared with FBP in both the liver and kidney ( P < 0.012). Streak artifact reduction was limited with hybrid IR. Model-based iterative reconstruction (MBIR) (one of the full IR algorithms) provided diagnostically more acceptable image quality ( P < 0.016) compared with FBP. Conclusion In abdominal CT without arm elevation, full IR enabled a more efficient streak artifact reduction compared with FBP and MBIR was associated with diagnostically more acceptable images.


Assuntos
Abdome/diagnóstico por imagem , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Braço , Meios de Contraste , Feminino , Humanos , Masculino , Posicionamento do Paciente , Imagens de Fantasmas , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
J Neurosci ; 35(12): 4813-23, 2015 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-25810512

RESUMO

Stop-signal task (SST) has been a key paradigm for probing human brain mechanisms underlying response inhibition, and the inhibition observed in SST is now considered to largely depend on a fronto basal ganglia network consisting mainly of right inferior frontal cortex, pre-supplementary motor area (pre-SMA), and basal ganglia, including subthalamic nucleus, striatum (STR), and globus pallidus pars interna (GPi). However, causal relationships between these frontal regions and basal ganglia are not fully understood in humans. Here, we partly examined these causal links by measuring human fMRI activity during SST before and after excitatory/inhibitory repetitive transcranial magnetic stimulation (rTMS) of pre-SMA. We first confirmed that the behavioral performance of SST was improved by excitatory rTMS and impaired by inhibitory rTMS. Afterward, we found that these behavioral changes were well predicted by rTMS-induced modulation of brain activity in pre-SMA, STR, and GPi during SST. Moreover, by examining the effects of the rTMS on resting-state functional connectivity between these three regions, we showed that the magnetic stimulation of pre-SMA significantly affected intrinsic connectivity between pre-SMA and STR, and between STR and GPi. Furthermore, the magnitudes of changes in resting-state connectivity were also correlated with the behavioral changes seen in SST. These results suggest a causal relationship between pre-SMA and GPi via STR during response inhibition, and add direct evidence that the fronto basal ganglia network for response inhibition consists of multiple top-down regulation pathways in humans.


Assuntos
Gânglios da Base/fisiologia , Lobo Frontal/fisiologia , Inibição Psicológica , Córtex Motor/fisiologia , Estimulação Magnética Transcraniana , Adulto , Mapeamento Encefálico , Humanos , Imageamento por Ressonância Magnética , Masculino , Vias Neurais/fisiologia , Desempenho Psicomotor/fisiologia
6.
J Magn Reson Imaging ; 39(6): 1426-30, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24129992

RESUMO

PURPOSE: To investigate the incidence of abnormal signal hyperintensity on T1-weighted magnetic resonance imaging (MRI) of the seminal vesicles in a screening population in order to compare clinical indicators between subjects with and without signal abnormality. MATERIALS AND METHODS: Signal intensity of the seminal vesicles on T1-weighted images and clinical examinations were investigated in 3570 examinations of 1865 male subjects (mean age 54.8 years, range 23-86 years at the first examination). RESULTS: Abnormal signal hyperintensity was observed at least once in 32 subjects (1.7%). Subjects with the abnormality were significantly older (average age with and without the abnormality, 64.1 vs. 54.6, respectively, P < 0.001), and the incidence of abnormality increased with increasing age (0% for the age group <40, 0.3% for 40-49, 1.3% for 50-59, 2.9% for 60-69, 5.9% for 70-79, and 10.1% for >80). No significant difference was found in clinical indicators except for serum creatinine (1.10 vs. 0.84 mg/dL, P < 0.001). Of 12 subjects with abnormal signal intensity and follow-up data, the finding persisted on the same side for at least 11 months in seven subjects (58%). CONCLUSION: Abnormal signal intensity of the seminal vesicles was observed in 1.7% of screening population, and the imaging finding in isolation is unlikely to have clinical significance.


Assuntos
Imageamento por Ressonância Magnética/métodos , Glândulas Seminais/patologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Adulto Jovem
7.
J Magn Reson Imaging ; 40(5): 1208-14, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24249331

RESUMO

PURPOSE: To investigate the use of non-Gaussian diffusion-weighted imaging (q-space imaging [QSI]) to estimate diurnal changes in intervertebral disc (IVD) microstructure. MATERIALS AND METHODS: IVDs of 15 male subjects (mean age, 27.3 years; mean body mass index, 22.50 kg/m(2) ) were investigated once in the morning, less than 30 min after rising, and a second time in the evening after at least 10 h of normal physical activity, using 3 Tesla (T) MR imaging. T2 mapping and QSI data values (apparent diffusion coefficient [ADC], root mean square displacement [RMSD], and apparent kurtosis coefficient [AKC]) were calculated and compared between the morning and evening imaging sessions. RESULTS: The T2, ADC, and RMSD values showed a significant decrease in the evening (175.8 ± 49.5 ms, 1.56 ± 0.32 10(-3) mm(2) /s and 40.0 ± 3.0 µm, respectively; P < 0.05 for all values; paired t-test), when compared with the morning values (226.5 ± 83.8 ms, 1.69 ± 0.29 10(-3) mm(2) /s and 45.2 ± 2.9 µm, respectively). The AKC value showed a significant increase in the evening (0.67 ± 0.08), when compared with the morning value (0.58 ± 0.04; P < 0.05). CONCLUSION: The RMSD and AKC values obtained from QSI analysis may be biomarkers for IVD diurnal microstructural changes.


Assuntos
Ritmo Circadiano/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disco Intervertebral/ultraestrutura , Adulto , Humanos , Masculino , Distribuição Normal , Valores de Referência , Software
8.
Eur Radiol ; 22(8): 1613-23, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22538629

RESUMO

OBJECTIVES: To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). METHODS: One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. RESULTS: Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 ± 3.00) than low-dose ASIR (49.24 ± 9.11, P < 0.01) and reference-dose ASIR images (24.93 ± 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. CONCLUSION: Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. KEY POINTS: • Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. • MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. • MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. • The prolonged processing time of MBIR may currently limit its routine use in clinical practice.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Artefatos , Peso Corporal , Diagnóstico por Imagem/métodos , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Movimento (Física) , Imagens de Fantasmas , Estudos Prospectivos , Reprodutibilidade dos Testes
9.
Neuroradiology ; 54(8): 873-82, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22358111

RESUMO

INTRODUCTION: Immunoglobulin (Ig) G4-related disease is a recently designated benign clinical entity histopathologically characterized by sclerosing inflammation and infiltration of numerous IgG4+ plasma cells that affects multiple organs. The purpose of this study is to characterize the imaging findings of patients with histopathologically proven IgG4-related disease in the head, neck, and brain. METHODS: A total of 17 patients (15 males, 2 females; mean age, 66.1 ± 7.4 years) with histopathologically proven IgG4-related disease in the head, neck, and brain were identified in two hospitals between January 2004 and December 2010. Imaging findings were retrospectively reviewed, with particular attention to the location and number of lesions, internal architecture, enhancement patterns, presence of vascular occlusion or compression, and changes in adjacent bones. RESULTS: The lesions, presented as either enlarged gland(s), or focal, localized nodules/masses, were distributed in the lacrimal gland (n = 7), the parotid gland (n = 14), the submandibular gland (n = 10), the pituitary gland (n = 2), skull base dura mater (n = 2), and the pterygopalatine fossa (n = 3). All lesions were well-defined and iso- to hypointense on T2-weighted magnetic resonance images and showed homogeneous enhancement. No lesion showed vascular occlusion or compression. Bones adjacent to the lesions showed remodeling (erosion or sclerosis) without signs of destruction (n = 6). Four patients had lesions involving multiple areas which extended along the trigeminal nerve, accompanied by expansion of neural foramina along their courses, with no signs of bone destruction. CONCLUSION: Sites of predilection for IgG4-related disease in the head, neck, and brain include the lacrimal, salivary, and pituitary glands. Recognition of the typical radiological features of IgG4-related disease, such as well-defined lesion borders, T2 hypointensity, homogeneous and gradual enhancement pattern, absence of vascular occlusion or compression, and presence of bone remodeling without destruction, may be of help in the diagnosis of this benign clinical entity.


Assuntos
Doenças Autoimunes/diagnóstico , Doenças Autoimunes/imunologia , Encefalopatias/diagnóstico , Encefalopatias/imunologia , Imunoglobulina G/imunologia , Doenças do Aparelho Lacrimal/diagnóstico , Doenças do Aparelho Lacrimal/imunologia , Doenças da Hipófise/diagnóstico , Doenças da Hipófise/imunologia , Doenças das Glândulas Salivares/diagnóstico , Doenças das Glândulas Salivares/imunologia , Idoso , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
J Endocr Soc ; 7(2): bvac181, 2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36540156

RESUMO

Context: Tumor-induced osteomalacia (TIO) is one of the most common forms of acquired fibroblast growth factor 23 (FGF23)-related hypophosphatemia and is usually caused by phosphaturic mesenchymal tumors (PMTs). Although the complete resection of PMTs can cure TIO, preoperative localization of tumors by standard imaging modalities is often challenging. In addition to 18F-fluoro-2-deoxy-D-glucose positron emission tomography-computed tomography (FDG-PET) and 111In-pentetreotide scintigraphy (SRS), systemic FGF23 venous sampling (FGF23VS) has been used to help localize PMTs in specialized institutions. Objective: This study aimed to evaluate the diagnostic performance of each imaging test and their combinations in localizing PMTs. Methods: In an observational retrospective study of patients with adult-onset FGF23-related osteomalacia who underwent all 3 imaging studies (FDG-PET, SRS, and FGF23VS), the rate of successful preoperative localization of the tumors was evaluated only in the patients with pathological diagnoses of PMTs, considering the possibility that pathogenesis of patients without identified tumors might be due to other causes such as late-onset hereditary FGF23-related hypophosphatemia. Results: A total of 30 Japanese patients with TIO (median age, 60 years [range, 28-87 years]; 10 women [33.3%]) were included in the study. The success rate of preoperative localization for each test and combinations of 2 or 3 tests among 18 patients with PMTs was as follows: 72% (FDG-PET), 72% (SRS), 94% (FGF23VS), 89% (FDG-PET, SRS), 100% (FDG-PET, FGF23VS), 94% (SRS, FGF23VS), and 100% (FDG-PET, SRS, and FGF23VS). Conclusion: We observed the highest localization rate of PMTs in patients with identified PMTs with the combination of FDG-PET and FGF23VS.

11.
Neuroimage ; 54(4): 3085-92, 2011 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-21035553

RESUMO

Application of multivoxel pattern analysis (MVPA) to functional magnetic resonance imaging (fMRI) data enables reconstruction and classification of cognitive status from brain activity. However, previous studies using MVPA have extracted information about cognitive status that is experienced simultaneously with fMRI scanning, but not one that will be observed after the scanning. In this study, by focusing on activity in the medial temporal lobe (MTL), we demonstrate that MVPA on fMRI data is capable of predicting subsequent recognition performance. In this experiment, six runs of fMRI signals were acquired during encoding of phonogram stimuli. In the analysis, using data acquired in runs 1-3, we first conducted MVPA-based voxel-wise search for the clusters in the MTL whose signals contained the most information about subsequent recognition performance. Next, using the fMRI signals acquired in runs 1-3 from the selected clusters, we trained a classifier function in MVPA. Finally, the trained classifier function was applied to fMRI signals acquired in runs 4-6. Consequently, we succeeded in predicting the subsequent recognition performance for stimuli studied in runs 4-6 with significant accuracy. This accurate prediction suggests that MVPA can extract information that is associated not only with concurrent cognitive status, but also with behavior in the near future.


Assuntos
Inteligência Artificial , Mapeamento Encefálico/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Psicológico/fisiologia , Lobo Temporal/fisiologia , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Adulto Jovem
12.
Bone Rep ; 15: 101144, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34901334

RESUMO

CONTEXT: Fibroblast growth factor (FGF) 23 is a hormone that regulates serum phosphate levels, the excess action of which causes chronic hypophosphatemic rickets/osteomalacia. To date, there are only two identified causes of acquired FGF23-related hypophosphatemic osteomalacia: tumor-induced osteomalacia (TIO) and osteomalacia induced by the intravenous infusion of some forms of iron preparations. In the current study, two cases of FGF23-related hypophosphatemia probably induced by chronic alcohol consumption were first introduced. CASE DESCRIPTION: Case 1 and case 2 had been drinking high amounts of alcohol for more than twenty years until they were admitted to the hospital. Case 1 was a 43-year-old man with progressive worsening multiple pains and muscle weakness who exhibited chronic hypophosphatemia with increased intact FGF23 levels. A week after admission, the serum phosphate level recovered to the reference range, and the intact FGF23 level declined. Case 1 resumed drinking after discharge, and hypophosphatemia concomitant with high intact FGF23 levels recurred. The alleviation of FGF23-related hypophosphatemia was observed each time he temporarily abstained from drinking for a short period. Case 2 was a 60-year-old man with recurrent fractures and exacerbation of pain in multiple joints who also exhibited hypophosphatemia with increased intact FGF23 levels. After admission, the serum phosphate level gradually increased to the lower limit of the normal range. The intact FGF23 level decreased, but it was still higher than 30 pg/ml, and causative FGF23-producing tumors were not identified even with thorough examinations, including somatostatin receptor scintigraphy, fluorine-18-fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) and systemic venous FGF23 sampling. He completely abstained from alcohol after discharge. Along with the serum phosphate level, intact FGF23 was subsequently decreased and had been normalized for 5 months. Both patients had no genetic mutation related to hereditary FGF23-related hypophosphatemic rickets/osteomalacia, including autosomal dominant hypophosphatemic rickets/osteomalacia (ADHR). CONCLUSION: Two cases of FGF23-related hypophosphatemia probably induced by alcohol were first introduced in this study. Identifying this reversible condition among acquired FGF23-related hypophosphatemic osteomalacia is critical to obtain better patient outcomes and save medical resources. This condition is similar to iron infusion-induced FGF23-related hypophosphatemia in terms of the dysregulation of FGF23 due to exogenous factors. Future research to elucidate the precise mechanism of these conditions is warranted.

13.
Intern Med ; 58(3): 411-414, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30210125

RESUMO

A 21-year-old woman was referred to our hospital because of proteinuria and hematuria. She had occasional flank pain. A renal biopsy was performed and revealed a thin basement membrane. Therefore, she was diagnosed with thin basement membrane disease. However, the frequency of her flank pain increased. Since her left kidney was slightly larger than the right, nutcracker syndrome (NCS) was suspected. Renal vein ultrasonography and venography were performed, and NCS was confirmed. Her hematuria was multifactorial, and NCS can go unnoticed if there is a comorbidity that also causes hematuria.


Assuntos
Síndrome do Quebra-Nozes/diagnóstico , Membrana Basal/patologia , Diagnóstico Diferencial , Feminino , Dor no Flanco/complicações , Hematúria/complicações , Humanos , Rim/irrigação sanguínea , Flebografia , Proteinúria/complicações , Síndrome do Quebra-Nozes/complicações , Síndrome do Quebra-Nozes/diagnóstico por imagem , Veias Renais/patologia , Adulto Jovem
14.
Eur J Radiol ; 93: 243-251, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28668422

RESUMO

OBJECTIVES: To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP). METHODS: Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF). RESULTS: MBIR offered significantly lower objective image noise (22.24±4.53, P<0.01 among all pairs, Student's t-test) compared with ASIR (39.76±7.41) and FBP (51.91±9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (P<0.01 among all pairs, the sign test), and streak artifacts (P<0.01 each for MBIR vs. the other 2 image data sets). CONCLUSION: MBIR provides high-quality HRCT images for interstitial lung disease by reducing image noise and streak artifacts and improving spatial resolution compared with ASIR and FBP.


Assuntos
Algoritmos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Idoso , Artefatos , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cintilografia , Tomografia Computadorizada por Raios X/métodos
15.
Jpn J Radiol ; 34(7): 459-69, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27138052

RESUMO

Meningiomas are common neoplasms that frequently occur in the brain and spine. Among the 15 histological subtypes of meningiomas in the WHO classification, the incidence of meningothelial meningiomas is the highest, followed by fibrous and transitional meningiomas. These three subtypes account for approximately 80 % of all meningiomas, and thus could be regarded as typical meningiomas. For this reason, other uncommon histological subtypes may be considered as imaging variants, and diagnosis is often challenging for radiologists solely based on imaging features of typical meningiomas. In addition to the histological subtypes, meningiomas arising in atypical locations could be easily mistaken for other lesions more commonly observed in those locations. The purpose of this article is to review characteristic clinical and imaging findings of uncommon meningiomas, including histological variants and meningiomas occurring in relatively rare locations.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Encéfalo/diagnóstico por imagem , Humanos , Meninges/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem
16.
Acta Radiol Open ; 5(1): 2058460116628340, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27110389

RESUMO

BACKGROUND: Iterative reconstruction methods have attracted attention for reducing radiation doses in computed tomography (CT). PURPOSE: To investigate the detectability of pancreatic calcification using dose-reduced CT reconstructed with model-based iterative construction (MBIR) and adaptive statistical iterative reconstruction (ASIR). MATERIAL AND METHODS: This prospective study approved by Institutional Review Board included 85 patients (57 men, 28 women; mean age, 69.9 years; mean body weight, 61.2 kg). Unenhanced CT was performed three times with different radiation doses (reference-dose CT [RDCT], low-dose CT [LDCT], ultralow-dose CT [ULDCT]). From RDCT, LDCT, and ULDCT, images were reconstructed with filtered-back projection (R-FBP, used for establishing reference standard), ASIR (L-ASIR), and MBIR and ASIR (UL-MBIR and UL-ASIR), respectively. A lesion (pancreatic calcification) detection test was performed by two blinded radiologists with a five-point certainty level scale. RESULTS: Dose-length products of RDCT, LDCT, and ULDCT were 410, 97, and 36 mGy-cm, respectively. Nine patients had pancreatic calcification. The sensitivity for detecting pancreatic calcification with UL-MBIR was high (0.67-0.89) compared to L-ASIR or UL-ASIR (0.11-0.44), and a significant difference was seen between UL-MBIR and UL-ASIR for one reader (P = 0.014). The area under the receiver-operating characteristic curve for UL-MBIR (0.818-0.860) was comparable to that for L-ASIR (0.696-0.844). The specificity was lower with UL-MBIR (0.79-0.92) than with L-ASIR or UL-ASIR (0.96-0.99), and a significant difference was seen for one reader (P < 0.01). CONCLUSION: In UL-MBIR, pancreatic calcification can be detected with high sensitivity, however, we should pay attention to the slightly lower specificity.

17.
Eur J Radiol ; 85(3): 599-606, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26860673

RESUMO

OBJECTIVE: To compare the image quality of high-resolution computed tomography (HRCT) for evaluating lung nodules reconstructed with the new version of model-based iterative reconstruction and spatial resolution preference algorithm (MBIRn) vs. conventional model-based iterative reconstruction (MBIRc) and adaptive statistical iterative reconstruction (ASIR). MATERIALS AND METHODS: This retrospective clinical study was approved by our institutional review board and included 70 lung nodules in 58 patients (mean age, 71.2±10.9years; 34 men and 24 women). HRCT of lung nodules were reconstructed using MBIRn, MBIRc and ASIR. Objective image noise was measured by placing the regions of interest on lung parenchyma. Two blinded radiologists performed subjective image analyses. RESULTS: Significant improvements in the following points were observed in MBIRn compared with ASIR (p<0.005): objective image noise (24.4±8.0 vs. 37.7±10.4), subjective image noise, streak artifacts, and adequateness for evaluating internal characteristics and borders of nodules. The sharpness of small vessels and bronchi and diagnostic acceptability with MBIRn were significantly better than with MBIRc and ASIR (p<0.008). CONCLUSION: HRCT reconstructed with MBIRn provides diagnostically more acceptable images for the detailed analyses of lung nodules compared with MBIRc and ASIR.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Jpn J Radiol ; 34(5): 339-48, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26906520

RESUMO

PURPOSE: To compare new and conventional versions of model-based iterative reconstruction (MBIR) in reduced-dose computed tomography (CT) in terms of diagnostic performance for hepatic steatosis. MATERIALS AND METHODS: Images were reconstructed from standard-dose and aggressively reduced-dose (the dose-length product was reduced by 91 %) unenhanced abdominopelvic CT scans of 86 patients using filtered back projection (SD-FBP) and new and conventional versions of MBIR (RD-MBIRn and RD-MBIRc), respectively. The mean CT attenuation of the liver (CT[L]) and the spleen as well as the ratio of these parameters (CT[L/S]) were calculated. CT[L] <48 Hounsfield units (HU) and CT[L/S] <1.1 were applied to SD-FBP (used as the reference standard; the number of positive patients was 12 and 14, respectively), RD-MBIRn, and RD-MBIRc. RESULTS: CT[L]s in SD-FBP/RD-MBIRn/RD-MBIRc were 56.9/55.9/52.8 HU. The difference in CT[L] between RD-MBIRn and SD-FBP was within ±5.0 HU in most cases. The sensitivity/specificity/accuracy of CT[L] <48 HU in RD-MBIRn and RD-MBIRc were 1.00/0.97/0.98 and 1.00/0.92/0.93, respectively, showing that RD-MBIRn permits significant improvements in specificity and accuracy (P < 0.05, McNemar test). For CT[L/S] <1.1, these values were 0.79/0.97/0.94 and 0.79/0.97/0.94 in RD-MBIRn and RD-MBIRc, respectively. CONCLUSION: When CT[L] <48 HU was applied, RD-MBIRn presented a significantly improved hepatic steatosis diagnostic performance compared with RD-MBIRc; indeed, it was almost equivalent to that afforded by SD-FBP.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Jpn J Radiol ; 34(9): 625-32, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27400700

RESUMO

PURPOSE: To compare the quality of helical computed tomography (CT) images of the pelvis in patients with metal hip prostheses reconstructed using adaptive iterative dose reduction (AIDR) and AIDR with single-energy metal artifact reduction (SEMAR-A). MATERIALS AND METHODS: This retrospective study included 28 patients (mean age, 64.6 ± 11.4 years; 6 men and 22 women). CT images were reconstructed using AIDR and SEMAR-A. Two radiologists evaluated the extent of metal artifacts and the depiction of structures in the pelvic region and looked for mass lesions. A radiologist placed a region of interest within the bladder and recorded CT attenuation. RESULTS: The metal artifacts were significantly reduced in SEMAR-A as compared to AIDR (p < 0.0001). The depictions of the bladder, ureter, prostate/uterus, rectum, and pelvic sidewall were significantly better with SEMAR-A than with AIDR (p < 0.02). All lesions were diagnosed with SEMAR-A, while some were not diagnosed with AIDR. The median and interquartile range (in parentheses) of CT attenuation within the bladder for AIDR were -34.0 (-46.6 to -15.0) Hounsfield units (HU) and were more variable than those seen for SEMAR-A [5.4 (-1.3 to 11.1)] HU (p = 0.033). CONCLUSION: In comparison with AIDR, SEMAR-A provided pelvic CT images of significantly better quality for patients with metal hip prostheses.


Assuntos
Artefatos , Prótese de Quadril , Processamento de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Feminino , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Eur J Radiol ; 83(7): 1063-1068, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24775685

RESUMO

PURPOSE: To determine whether dose-reduced CT with model-based iterative image reconstruction (MBIR) is a useful tool with which to diagnose hepatic steatosis. MATERIALS AND METHODS: This prospective clinical study approved by our Institutional Review Board included 103 (67 men and 36 women; mean age, 64.3 years) patients who provided written informed consent to undergo unenhanced CT. Images of reference-dose CT (RDCT) with filtered back projection (R-FBP) and low- and ultralow-dose CT (dose-length product; 24 and 9% of that of RDCT) with MBIR (L-MBIR and UL-MBIR) were reconstructed. Mean CT numbers of liver (CT[L]) and spleen (CT[S]), and quotient (CT[L/S]) of CT[L] and CT[S] were calculated from selected regions of interest. Bias and limits of agreement (LOA) of CT[L] and CT[L/S] in L-MBIR and UL-MBIR (vs. R-FBP) were assessed using Bland-Altman analyses. Diagnostic methods for hepatic steatosis of CT[L]<48 Hounsfield units (HU) and CT[L/S]<1.1 were applied to L-MBIR and UL-MBIR using R-FBP as the reference standard. RESULTS: Bias was larger for CT[L] in UL-MBIR than in L-MBIR (-3.18HU vs. -1.73HU). The LOA of CT[L/S] was larger for UL-MBIR than for L-MBIR (±0.425 vs. ±0.245) and outliers were identified in CT[L/S] of UL-MBIR. Accuracy (0.92-0.95) and the area under the receiver operating characteristics curve (0.976-0.992) were high for each method, but some were slightly lower in UL-MBIR than L-MBIR. CONCLUSION: Dose-reduced CT reconstructed with MBIR is applicable to diagnose hepatic steatosis, however, a low dose of radiation might be preferable.


Assuntos
Algoritmos , Fígado Gorduroso/diagnóstico por imagem , Modelos Biológicos , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade