Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Medicina (Kaunas) ; 60(7)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-39064539

RESUMO

Background and Objectives: The purpose of this study was to compare two commercially available specular microscopes (Tomey EM-4000 and Nidek CEM-530) in a real-life clinical setting in terms of intra- and interdevice variability. The study was conducted on all patients seen in a clinical practice specializing in anterior segment pathologies, regardless of the purpose of their visit. Materials and Methods: In total, 112 eyes of 56 patients (age 23-85 years old) were included in the study. Each eye was measured three times with each device (for a total of six measurements), and results for central corneal thickness (CCT) and corneal endothelial cell density (ECD) were recorded. The results were then evaluated with the D'Agostino-Pearson normality test and compared with a Wilcoxon signed-rank test, t-test, ANOVA or Mann-Whitney test for intra- and interdevice variability. Results: Both specular microscopes produced very reliable reproducible intradevice results: The Tomey EM-4000 measured an ECD of 2390 ± 49.57 cells/mm2 (mean ± standard error of mean); the range was 799-3010 cells/mm2. The determined CCT was 546 ± 5.104 µm (mean ± standard error of mean [SEM]); the range was 425-615 µm. The measurements with the Nidek CEM-530 revealed an ECD of 2417 ± 0.09 cells/mm2 (mean ± SEM); the range was 505-3461 cells/mm2 (mean ± SEM). The mean CCT detected was 546.3 ± 4.937 µm (mean ± SEM); the range was 431-621 µm. The interdevice differences were statistically significant for both parameters, ECD (p = 0.0175) and CCT (p = 0.0125) (p < 0.05). Conclusions: The Nidek CEM-530 and the Tomey EM-4000 both produced reliable and reproducible results in terms of ECD and CCT. The absolute measurements were statistically significantly different for CCT and ECD for both devices; the Nidek produces slightly higher values.


Assuntos
Microscopia , Humanos , Pessoa de Meia-Idade , Idoso , Adulto , Masculino , Feminino , Idoso de 80 Anos ou mais , Microscopia/instrumentação , Microscopia/métodos , Reprodutibilidade dos Testes , Contagem de Células/instrumentação , Contagem de Células/métodos , Adulto Jovem
2.
Hum Mol Genet ; 29(4): 618-623, 2020 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-31903486

RESUMO

In a consanguineous Pakistani family with two affected individuals, a homozygous variant Gly399Val in the eighth transmembrane domain of the taurine transporter SLC6A6 was identified resulting in a hypomorph transporting capacity of ~15% compared with normal. Three-dimensional modeling of this variant has indicated that it likely causes displacement of the Tyr138 (TM3) side chain, important for transport of taurine. The affected individuals presented with rapidly progressive childhood retinal degeneration, cardiomyopathy and almost undetectable plasma taurine levels. Oral taurine supplementation of 100 mg/kg/day resulted in maintenance of normal blood taurine levels. Following approval by the ethics committee, a long-term supplementation treatment was introduced. Remarkably, after 24-months, the cardiomyopathy was corrected in both affected siblings, and in the 6-years-old, the retinal degeneration was arrested, and the vision was clinically improved. Similar therapeutic approaches could be employed in Mendelian phenotypes caused by the dysfunction of the hundreds of other molecular transporters.


Assuntos
Cardiomiopatias/tratamento farmacológico , Glicoproteínas de Membrana/deficiência , Proteínas de Membrana Transportadoras/deficiência , Degeneração Retiniana/tratamento farmacológico , Taurina/uso terapêutico , Adolescente , Transporte Biológico , Cardiomiopatias/metabolismo , Cardiomiopatias/patologia , Criança , Feminino , Humanos , Masculino , Linhagem , Degeneração Retiniana/metabolismo , Degeneração Retiniana/patologia
5.
Case Rep Ophthalmol ; 15(1): 585-589, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39144646

RESUMO

Introduction: Conjunctival cysts are usually asymptomatic but they can cause foreign body sensation and contribute to dry eye disease. The purpose of this case report is to describe the presentation and treatment of an infected inclusion cyst of a conjunctival nevus in a healthy 36-year-old patient. Case Presentation: A healthy 36-year-old man presented to the emergency department for redness and pain in his left eye for 1 day. Slit-lamp examination revealed a conjunctival hyperemia and a conjunctival nevus with 4 inclusion cysts, one of which was filled with purulent material. Fluorescein staining of the conjunctival epithelium was negative. Α mini-incision of the white cyst was performed using a 30 G needle, followed by bimanual drainage and topical treatment with tobramycin and moxifloxacin drops every 3 h for a week. A swab of the purulent drainage was positive for gram-positive flora. One week after the drainage of the cyst, the patient was asymptomatic and on slit-lamp examination, the 4 inclusion cysts were filled with a transparent liquid, there was not any vessel dilation and fluorescein staining was negative. Conclusion: Conjunctival inclusion cysts, although considered benign, can become infected and form a conjunctival abscess. A mini-incision on the slit lamp combined with bimanual drainage and followed by topical antibiotic drops seems to be a safe and effective treatment.

6.
Front Med (Lausanne) ; 10: 1131314, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36936227

RESUMO

Cataract surgery is among the most frequently performed surgical procedures worldwide and has a tremendous impact on patients' quality of life. Phacoemulsification (PCS) is accepted as a standard of care; its technique has continuously evolved and already achieved good anatomical, visual, and refractive outcomes. Lasers in ophthalmology are widely used in clinical practice, femtosecond lasers (FSLs) for corneal surgery in particular. It was natural to assess the usefulness of FSL in cataract surgery as this technology was within reach. Indeed, precise and reproducible cuttings provided by FSL platforms could improve standardization of care and limit the risk associated with the human element in surgery and provide a step toward robot-assisted surgery. After docking and planning the procedure, femtosecond lasers are used to perform corneal incisions, capsulorhexis, lens fragmentation, and arcuate incisions in an automated manner. A well-constructed corneal incision is primordial as it offers safety during the procedure, self-seals afterward, and influences the refractive outcome. Capsulorhexis size, centration, and resistance to shearing influence the surgery, intraocular lens (IOL) centration and stability, and posterior capsular opacification formation. Lens fragmentation is where most of the energy is delivered into the eye, and its amount influences endothelial cell damage and potential damage to other ocular structures. The arcuate incisions offer an additional opportunity to influence postoperative astigmatism. Femtosecond laser-assisted cataract surgery (FLACS) has been a topic of research in many studies and clinical trials that attempted to assess its potential benefits and cost-effectiveness over PCS and is the subject of this mini-review.

7.
J Ophthalmol ; 2021: 8448996, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34552765

RESUMO

PURPOSE: To evaluate the outcomes and safety of a minimally invasive technique for sutured IOL scleral fixation in case of compromised capsular and iris support. MATERIALS AND METHODS: In this retrospective study, we explain our mini-invasive technique and assess the outcomes in terms of visual acuity, pre- or postoperative complications, and IOL position (Sensar AR40e, AMO) in a case series of three patients. RESULTS: The expected best corrected visual acuity could be achieved after one month. Surgeries were uneventful with a stable eye. No postoperative complications occurred except for one patient who had a conjunctival disinsertion. Neither postoperative hypotony nor raised IOP was found. Additionally, no patient experienced corneal edema at one week control, IOL dislocation, vitreous hemorrhage, or new pupil's irregularity. CONCLUSIONS: In conclusion, each scleral technique has its own advantages and its inherent postoperative complications. To date, there is no evidence of superiority of any single technique. By improving our scleral sutured lens techniques, we could improve peroperative ocular stability, potentially decrease postoperative complication rate, and offer a rapid recovery with a stable visual acuity within a month.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA