Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Eur Radiol ; 34(4): 2805-2815, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37740080

RESUMO

OBJECTIVE: To evaluate the usage of a well-known and widely adopted checklist, Checklist for Artificial Intelligence in Medical imaging (CLAIM), for self-reporting through a systematic analysis of its citations. METHODS: Google Scholar, Web of Science, and Scopus were used to search for citations (date, 29 April 2023). CLAIM's use for self-reporting with proof (i.e., filled-out checklist) and other potential use cases were systematically assessed in research papers. Eligible papers were evaluated independently by two readers, with the help of automatic annotation. Item-by-item confirmation analysis on papers with checklist proof was subsequently performed. RESULTS: A total of 391 unique citations were identified from three databases. Of the 118 papers included in this study, 12 (10%) provided a proof of self-reported CLAIM checklist. More than half (70; 59%) only mentioned some sort of adherence to CLAIM without providing any proof in the form of a checklist. Approximately one-third (36; 31%) cited the CLAIM for reasons unrelated to their reporting or methodological adherence. Overall, the claims on 57 to 93% of the items per publication were confirmed in the item-by-item analysis, with a mean and standard deviation of 81% and 10%, respectively. CONCLUSION: Only a small proportion of the publications used CLAIM as checklist and supplied filled-out documentation; however, the self-reported checklists may contain errors and should be approached cautiously. We hope that this systematic citation analysis would motivate artificial intelligence community about the importance of proper self-reporting, and encourage researchers, journals, editors, and reviewers to take action to ensure the proper usage of checklists. CLINICAL RELEVANCE STATEMENT: Only a small percentage of the publications used CLAIM for self-reporting with proof (i.e., filled-out checklist). However, the filled-out checklist proofs may contain errors, e.g., false claims of adherence, and should be approached cautiously. These may indicate inappropriate usage of checklists and necessitate further action by authorities. KEY POINTS: • Of 118 eligible papers, only 12 (10%) followed the CLAIM checklist for self-reporting with proof (i.e., filled-out checklist). More than half (70; 59%) only mentioned some kind of adherence without providing any proof. • Overall, claims on 57 to 93% of the items were valid in item-by-item confirmation analysis, with a mean and standard deviation of 81% and 10%, respectively. • Even with the checklist proof, the items declared may contain errors and should be approached cautiously.


Assuntos
Inteligência Artificial , Lista de Checagem , Humanos , Diagnóstico por Imagem , Radiografia
2.
Eur Radiol ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38180530

RESUMO

OBJECTIVE: To evaluate the use of reporting checklists and quality scoring tools for self-reporting purposes in radiomics literature. METHODS: Literature search was conducted in PubMed (date, April 23, 2023). The radiomics literature was sampled at random after a sample size calculation with a priori power analysis. A systematic assessment for self-reporting, including the use of documentation such as completed checklists or quality scoring tools, was conducted in original research papers. These eligible papers underwent independent evaluation by a panel of nine readers, with three readers assigned to each paper. Automatic annotation was used to assist in this process. Then, a detailed item-by-item confirmation analysis was carried out on papers with checklist documentation, with independent evaluation of two readers. RESULTS: The sample size calculation yielded 117 papers. Most of the included papers were retrospective (94%; 110/117), single-center (68%; 80/117), based on their private data (89%; 104/117), and lacked external validation (79%; 93/117). Only seven papers (6%) had at least one self-reported document (Radiomics Quality Score (RQS), Transparent Reporting of a multivariable prediction model for Individual Prognosis Or Diagnosis (TRIPOD), or Checklist for Artificial Intelligence in Medical Imaging (CLAIM)), with a statistically significant binomial test (p < 0.001). Median rate of confirmed items for all three documents was 81% (interquartile range, 6). For quality scoring tools, documented scores were higher than suggested scores, with a mean difference of - 7.2 (standard deviation, 6.8). CONCLUSION: Radiomic publications often lack self-reported checklists or quality scoring tools. Even when such documents are provided, it is essential to be cautious, as the accuracy of the reported items or scores may be questionable. CLINICAL RELEVANCE STATEMENT: Current state of radiomic literature reveals a notable absence of self-reporting with documentation and inaccurate reporting practices. This critical observation may serve as a catalyst for motivating the radiomics community to adopt and utilize such tools appropriately, thereby fostering rigor, transparency, and reproducibility of their research, moving the field forward. KEY POINTS: • In radiomics literature, there has been a notable absence of self-reporting with documentation. • Even if such documents are provided, it is critical to exercise caution because the accuracy of the reported items or scores may be questionable. • Radiomics community needs to be motivated to adopt and appropriately utilize the reporting checklists and quality scoring tools.

3.
Graefes Arch Clin Exp Ophthalmol ; 261(1): 257-262, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35939121

RESUMO

PURPOSE: To investigate the prevalence of posttraumatic stress disorder (PTSD) and depression after open globe injury in adults. METHODS: A total of 95 participants, 43 adult patients with open globe injury and 52 age-sex similar subjects (control group), were included in this cross-sectional study. Age, gender, education level, occupation, accident history, psychiatric history, trauma type, cause of trauma, and visual acuity were recorded. One to six months after trauma, PTSD and depression symptoms of the participants were evaluated with the Posttraumatic Stress Disorder Questionnaire-Civil Version Scale (PTSD-S) and Beck Depression Inventory (BDI), respectively. RESULTS: Patients with open globe injury had a higher PTSD-S total score than the control group, but not significant (23.67 ± 20.41 vs. 18.56 ± 13.13, p = 0.580). Patients with eye trauma exhibited a much higher prevalence of PTSD compared to the control group (20.9% vs. 3.8%, p = 0.010). Patients with trauma had a significantly higher BDI total score than the control group (12.47 ± 10.08 vs. 7.69 ± 6.10, p = 0.015). Also, patients had a higher rate of depression symptoms than controls (25.6% vs. 7.7%, p = 0.017). A significant positive correlation was observed between PTSD-S and BDI scores in the trauma group (r = 0.720, p < 0.001). CONCLUSION: An increased prevalence of PTSD and depression was observed in adults after open globe injury. The significant relationship between PTSD-S and BDI scores indicates that patients with open globe injuries should be questioned in terms of both symptoms. For patients with open globe trauma, a holistic approach with psychosocial assessment in addition to physical intervention would be beneficial.


Assuntos
Traumatismos Oculares , Transtornos de Estresse Pós-Traumáticos , Humanos , Adulto , Transtornos de Estresse Pós-Traumáticos/diagnóstico , Transtornos de Estresse Pós-Traumáticos/epidemiologia , Transtornos de Estresse Pós-Traumáticos/etiologia , Depressão/diagnóstico , Depressão/epidemiologia , Depressão/etiologia , Estudos Transversais , Traumatismos Oculares/complicações
4.
Int Endod J ; 56(5): 637-646, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36637890

RESUMO

AIM: The present study aimed to determine and compare the dentine thickness around the root canals of maxillary molars with fusion using micro-computed tomography (micro-CT). METHODOLOGY: A total of 120 fused maxillary molars having more than a single canal with distinct canal orifices near the cementoenamel junction were selected from a pool of extracted maxillary molars, which were scanned on a micro-CT device (SkyScan 1172, Bruker-microCT). The minimum dentine thickness around the root canals in furcal direction was measured using CTAn software (v.1.18.8 Bruker-microCT) at each millimetre. The specimens were grouped according to their fusion type, and dentine thickness around the canals was compared. The data were statistically analysed using anova and post hoc Tukey-Kramer tests following an assessment of the normality of their distribution with the Kolmogorov-Smirnov test (p < .05). RESULTS: Dentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 (p < .05), while those of distobuccal and palatal canals were significantly thinner in type 3 fusion compared with type 1 or 6 (pDentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level  irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 ( CONCLUSION: Minimum dentine thickness values at the danger zone of distobuccal and palatal canals change according to the fusion type in fused maxillary second molars.


Assuntos
Dente Molar , Raiz Dentária , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Cavidade Pulpar/diagnóstico por imagem , Dentina/diagnóstico por imagem , Maxila/diagnóstico por imagem
5.
Lasers Med Sci ; 39(1): 13, 2023 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-38135858

RESUMO

This study is to determine whether post-procedure intraocular pressure (IOP) increase is associated with the anterior chamber angle in cases of Neodymium: yttrium-aluminum garnet (Nd: YAG) laser capsulotomy. The study included 51 eyes with posterior capsule opacification. Initial IOP values of the patients were compared with IOP values without intraocular pressure-lowering administration at the end of the 1st hour, 1st day, 3rd day, and 7th day after Nd:YAG laser capsulotomy. The anterior segment angle configuration was evaluated using anterior segment optical coherence tomography analysis without dilatation before the procedure. The anterior chamber angle (ACA) and angle opening distances of 500 and 750 µm (AOD500 and AOD750) in the nasal and temporal quadrants were examined. The mean pre-laser IOP value only increased significantly at 1st hour post-laser (13.02 ± 3.02 mmHg vs 14.16 ± 4.07 mmHg, p = 0.016). In eyes with ACA below 40° in both the nasal and temporal quadrants, mean IOP increased significantly at 1st hour post-laser (p = 0.025 and p = 0.032, respectively), while it was not significant in eyes with ACA above 40° (p > 0.05). No correlation was found between ACA, AOD500, and AOD750 values and IOP changes at the first hour (p > 0.05). Except for the first hour after Nd:YAG laser capsulotomy, no significant increase in IOP was observed. This elevation was higher in eyes with ACA less than 40°. In patients with a narrow ACA, first-hour follow-up may be beneficial in terms of susceptibility to increased IOP.


Assuntos
Opacificação da Cápsula , Glaucoma , Lasers de Estado Sólido , Humanos , Pressão Intraocular , Tomografia de Coerência Óptica/métodos , Lasers de Estado Sólido/efeitos adversos
6.
Clin Oral Investig ; 27(12): 7337-7344, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37861748

RESUMO

OBJECTIVE: This study assessed the outcome of shaping the mesial roots of mandibular first molars containing band-shaped isthmuses with an isthmus floor located at the apical third with Reciproc Blue and Rotate instruments in terms of canal transportation, canal aberrations and unprepared apical canals. MATERIALS AND METHODS: Pair-matched mesial roots of mandibular first molars according to their isthmus location (distance from apical foramina) and size were constructed based on quantitative measurements (length, major and minor diameter at isthmus roof and floor) on preoperative micro-CT scanning (n = 10). The pair-matched specimens were prepared either using Reciproc Blue R25 (25.08v) or Rotate (15.04, 20.05, 25.06) instruments and then subjected to a second micro-CT scanning. Micro-CT scans were analysed to evaluate the canal transportation at the apical foramen and isthmus floor levels and the frequency of procedural errors (separated instruments, artificial canal preparation, cross shaping and unprepared apical canals). Canal transportation values were compared using Mann-Whitney U, and the distribution of procedural errors was compared with chi-square tests with a 5% significance threshold. RESULTS: Greater transportation values were detected in the apical foramen level compared to the isthmus floor in both groups. No significant difference was detected between Rotate and Reciproc Blue groups in terms of absolute transportation values and the incidence of procedural errors (p > .05). CONCLUSION: Preparation of mesial root canals containing a band-shaped isthmus at the apical portion with Reciproc Blue and Rotate instruments caused transportation of the original canal position at the isthmus floor and the apical foramen levels and resulted in procedural errors. CLINICAL RELEVANCE: This ex vivo micro-CT study using controlled pair-matched specimens showed that presence of a band-shaped isthmus complicates canal preparation procedure irrespective of the preparation systems.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Microtomografia por Raio-X , Cavidade Pulpar/diagnóstico por imagem , Ápice Dentário , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Desenho de Equipamento
7.
Clin Oral Investig ; 27(8): 4667-4675, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37247087

RESUMO

OBJECTIVE: This study aimed to evaluate changes on root canal morphology in patients with different ages using micro-CT technology. MATERIALS AND METHODS: Mandibular first molars (n = 150) were scanned at a pixel size of 13.68 µm, categorized into 3 groups according to patient's age and analyzed regarding configuration, orifices, apical foramina, root length, canal volume, and surface area. Morphological 2D and 3D parameters were evaluated in distal roots with Type I configuration (n = 109) as well as the morphology of isthmuses Types I and III in 68 mesial roots. One-way ANOVA post hoc Tukey and Kruskal-Wallis tests were used for statistical analyses (α = 5%). RESULTS: A great variation in the canal configuration was found. No difference was observed in roots' length (p > 0.05). Canal volume reduced with age (p < 0.05), while surface area increased (p < 0.05) in patients ≤ 30 years. There was no difference in canal/root length, area, and from foramen to the apex in distal roots with Type I configuration (p > 0.05), but 2D and 3D parameters significantly decreased with age (p < 0.05). Overall, the diameter of the isthmuses' roof reduced with age (p < 0.05). In patients ≥ 31 years with Type III isthmus the distance from the isthmus floor to the foramen of the mesiolingual canal also decreased (p < 0.05). CONCLUSION: Overall, the internal morphology of the mesial roots of mandibular first molars was more affected by aging than distal canals. The most relevant tested parameter that significantly reduced in both roots was the volume of the root canal systems. CLINICAL RELEVANCE: A detailed evaluation of fine anatomical aspects of the root canal system of mandibular first molars of patients with different ages showed that the internal morphology of mesial roots is more affected by aging than distal canals.


Assuntos
Cavidade Pulpar , Mandíbula , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Microtomografia por Raio-X , Mandíbula/diagnóstico por imagem , Mandíbula/anatomia & histologia , Tratamento do Canal Radicular , Dente Molar/diagnóstico por imagem , Dente Molar/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/anatomia & histologia
8.
Artigo em Inglês | MEDLINE | ID: mdl-36634689

RESUMO

BACKGROUND: Osteogenesis imperfecta (OI) is a genetic disorder in which there are problems in tissues containing type I collagen, predominantly the cornea and sclera in the eye. Although there are many studies on problems with the anterior segment of the eye in patients with OI, studies on posterior structures are limited. Involvement of the sclera may affect the retinal nerve fibre layer (RNFL), which is indirectly related to intraocular pressure. In addition, the retina and choroid containing type I collagen may be affected. The aim of the study was to compare the posterior segment structures of the eye, including the RNFL, retina, and choroid, in patients with OI to those of healthy control subjects. METHODS: This cross-sectional study recruited 19 patients with OI, as well as 22 age- and gender-similar healthy control subjects. Measurements of the RNFL, retina, and choroid were obtained with optical coherence tomography (Spectralis SD-OCT, Heidelberg Engineering, Heidelberg, Germany). RESULTS: Patients with OI (mean age 14.32 ± 5.08 years) and the control group (mean age 13.73 ± 3.56 years) had similar age, refractive error, and intraocular pressure values (p > 0.05). There was no difference between groups in terms of RNFL thickness, including the superonasal, nasal, inferonasal, inferotemporal, temporal, and superotemporal sectors, retinal thickness, and choroidal thickness from five different locations (p > 0.05, for all). CONCLUSION: According to these results, OI does not clinically affect the RNFL, retina, and choroid in childhood.

9.
BMC Oral Health ; 23(1): 106, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36797742

RESUMO

BACKGROUND: This study aimed to investigate the remineralization efficiency of Sensodyne Promine containing Sodium flouride (NaF), GC Tooth Mousse containing CPP-ACP, and Agarta herbal toothpaste on initial caries and erosion using micro-computed tomography (CT) and scanning electron microscopy (SEM). METHODS: Forty-five third-molar teeth for micro-CT were divided into three main groups after initial scans (T1) were completed. Artificial caries lesions were created with the demineralization cycle (group 1, n = 15) and artificial erosion lesions were created with orange juice (group 2, n = 15) and Cola (group 3, n = 15), and second scans (T2) were performed. The groups were divided into three subgroups within themselves. Sensodyne Promine toothpaste (subgroup 1a, 2a, 3a), GC Tooth Mousse topical cream (subgroup 1b, 2b, 3b), and Agarta herbal toothpaste (subgroup 1c, 2c, 3c) were applied using soft-tipped brushes for 2 min, twice per day for 15 days, and then a third scan (T3) was performed. Mineral density, surface area, and lesion volume and depth were calculated using micro-CT. Changes in the surface morphology of the teeth were examined using SEM in 13 samples representing each group, subgroup, and healthy enamel. In the analysis of the data obtained from the scans performed at three different times (T1, T2, T3), one-way analysis of variance (ANOVA) with the post-hoc Tukey test, repeated measures ANOVA with the post-hoc Bonferroni test, and paired sample t-test analyses were used. RESULTS: All three agents caused a statistically significant increase in mineral density, and a decrease in surface area and lesion volume and depth (p < 0.05). There was no statistically significant difference between the groups in remineralization efficiency (p > 0.05). A statistically significant difference was found between the groups regarding the mineral density of the tissue that increased after remineralization (NaF > CPP-ACP > He; p < 0.05). CONCLUSION: The remineralization efficacy of herbal toothpaste as an alternative to NaF and CPP-ACP was found to be successful.


Assuntos
Cárie Dentária , Cremes Dentais , Humanos , Microtomografia por Raio-X , Microscopia Eletrônica de Varredura , Suscetibilidade à Cárie Dentária , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/tratamento farmacológico , Cárie Dentária/patologia , Minerais , Caseínas , Remineralização Dentária/métodos , Cariostáticos
10.
BMC Oral Health ; 23(1): 780, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37875946

RESUMO

BACKGROUND: This study aimed to compare the shaping ability of different instruments, TruNatomy Glider (TRN-G), WaveOne Gold Glider (WOG-G), and ProGlider (Pro-G) using micro-computed tomography (micro-CT). METHODS: The mesial canals of 27 mandibular molars with two separate mesial canals and moderate curvature were included in this study [n = 27 mesiobuccal (MB) and mesiolingual (ML) root canal]. According to the manufacturer's instructions, the glide path was created with TRN-G, WOG-G, and Pro-G glide path instruments (n = 9 MB and ML root canal in each group). Micro-CT scanning was performed before and after preparation. Mesiodistal (MD) and buccolingual (BL) transportation and the centering ratio were measured at three levels within the canal (3, 5 and 7 mm). A three-way robust ANOVA was used to compare the parameters. RESULTS: TRN-G showed significantly greater transportation in the MD direction than the other instruments throughout the root canal (overall root canal) (p < 0.05). The best centering ability in the BL direction was shown by the WOG-G, regardless of level within the canal and canal distinction (MB vs. ML) (p < 0.05). There was no significant difference between groups according to the level within the canal and canal parameters (p > 0.05). Whether the root canal was MB or ML did not affect centering or transportation (p > 0.05). CONCLUSIONS: Glide path instruments can be used to shape moderately curved canals with minimal apical transportation and better centering ability. All three tested glide path files can used safely before the shaping file.


Assuntos
Preparo de Canal Radicular , Raiz Dentária , Humanos , Microtomografia por Raio-X/métodos , Tratamento do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento
11.
Clin Oral Investig ; 26(9): 5909-5914, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35578113

RESUMO

OBJECTIVES: This micro-computed tomography (micro-CT) study analyzed band-shaped isthmuses having their floor at the apical third of the mesiobuccal roots of maxillary molars in terms of 2D and 3D morphological parameters. MATERIALS AND METHODS: A total of 199 maxillary first molars were scanned with micro-CT. Twenty-seven specimens, confirmed to have a band-shaped isthmus, were further examined in terms of the isthmus length, volume, structure model index (SMI), and surface area. The distance of apical foramina of mesial canals from the isthmus floor and major-minor diameters, roundness, perimeter, and area of the isthmus roof and floor were compared. Statistical analyses were performed with descriptive statistics and t-test with a 5% significance threshold. RESULTS: The band-shaped isthmus frequency was 13.5% and its length reached up to 5.5 mm. The distances of the apical foramina of mesiobuccal canals (MB1 and MB2) from the isthmus floor were similar (p > .05). Isthmus roof and floor showed significant differences in terms of their major diameter and area (p < .05), whereas their minor diameter, roundness, and perimeter values were similar (p > .05). CONCLUSION: The band-shaped isthmuses are not rare and can reach through the half of the root length with oval cross-sections in the floor and roof anatomy. The distance between the isthmus floor and apical foramina did not differ between MB1 and MB2. CLINICAL RELEVANCE: The band-shaped isthmus morphology contributes to the complexity of the apical anatomy of maxillary first molar teeth with various lengths and diameters.


Assuntos
Cavidade Pulpar , Dente Molar , Raiz Dentária , Microtomografia por Raio-X , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Maxila , Dente Molar/anatomia & histologia , Dente Molar/diagnóstico por imagem , Ápice Dentário , Raiz Dentária/anatomia & histologia , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos
12.
Clin Oral Investig ; 26(2): 1353-1360, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34373955

RESUMO

OBJECTIVES: The present study aimed to evaluate the frequency, position, and length of radicular pulp calcifications in three-rooted maxillary first molars using micro-computed tomography. MATERIALS AND METHODS: Two hundred three-rooted maxillary first molars were scanned at a pixel size of 10 µm and reconstructed using similar parameters. Three-dimensional models of the mesiobuccal (MB1, MB2, MB3), distobuccal (DB), and palatal (P) canals were qualitatively evaluated for discontinuity in the canal path. Transaxial and sagittal cross-sectional images of the roots were further screened, and the complete obliteration of the canal lumen by pulp calcification was identified when the canal had similar radiodensity to the surrounding dentine. Then, the number, position, and length of the calcifications were recorded for each root. Intra-observer agreement was performed using Cohen's kappa test, while one-way ANOVA and Duncan tests compared the lengths of calcifications among the canals, with α = 5%. RESULTS: Intra-observer agreement was perfect for identification of pulp calcifications (ĸ = 1.0; p = 0.000). MB2 and MB3 canals accounted for the highest percentage frequency of calcifications distributed throughout the canal path. In the MB1, DB, and P canals, they occurred mainly at the apical third. Lengths of calcifications were greater in the MB3 (0.89 ± 0.81 mm) and MB2 (0.82 ± 0.93 mm) canals than in the MB1 (0.39 ± 0.32 mm), DB (0.34 ± 0.22 mm), and P (0.28 ± 0.22 mm) canals (p < 0.05). CONCLUSION: MB2 and MB3 canals accounted for the highest frequency and length of radicular pulp calcifications. In the MB1, DB, and P canals, calcifications occurred mostly at the apical third, while in the MB2 and MB3, most of calcifications were observed at the orifice level and along the canal path. CLINICAL RELEVANCE: In maxillary first molars, radicular pulp calcifications are mainly located at the apical third of the MB1, DB, and P canals, while in the MB2 and MB3 canals, most of them are at the orifice level or along the canal path.


Assuntos
Cavidade Pulpar , Maxila , Cavidade Pulpar/diagnóstico por imagem , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária , Microtomografia por Raio-X
13.
Odontology ; 110(4): 769-776, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35218447

RESUMO

Irrigation dynamics of syringe irrigation with different needle designs (side-vented, double side-vented, notched) and ultrasonic irrigation in the root canal with internal root resorption were evaluated using a computational fluid dynamics model. A micro-CT scanned mandibular premolar was used for modeling internal root resorption. The needles and the ultrasonic tip were positioned at 2, 4, and 5 mm from the working length. The insertion depth and the irrigation model were found influential on the shear stress and the irrigant extension. The extension of the irrigant increased toward 2-5 mm from the working length. Ultrasonic irrigation revealed the highest shear stress values regardless of the insertion depth. The shear stress distribution on the resorption cavity walls gradually increased when the needles were positioned coronally. The residence time of the irrigant in the canal was affected by the needle position relative to the internal root resorption cavity and the needle type.


Assuntos
Hidrodinâmica , Reabsorção da Raiz , Cavidade Pulpar , Humanos , Irrigantes do Canal Radicular , Preparo de Canal Radicular , Irrigação Terapêutica
14.
J Prosthet Dent ; 127(5): 744-749, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-33454117

RESUMO

STATEMENT OF PROBLEM: Endocrowns have been reported to be successful restorations for endodontically treated molars. However, comparisons between maxillary and mandibular molars, with different pulp chamber configurations are lacking. Information on the influence of venting on the adaptation of endocrowns is also lacking. PURPOSE: The purpose of this in vitro study was to evaluate the adaptation of endocrowns in maxillary and mandibular molars by means of microcomputed tomography (µCT). MATERIAL AND METHODS: Mandibular and maxillary first molars were divided into 4 groups (n=10): ManE: mandibular endocrown; ModManE: modified mandibular endocrown; MaxE: maxillary endocrown; and ModMaxE: modified maxillary endocrown. Endocrowns were produced by using computer-aided design and computer-aided manufacture (CAD-CAM). Modification was carried out on the part of the endocrown that extended into the pulp chamber by preparing vents. The specimens were cemented and scanned by using µCT, the images reconstructed, and the internal and marginal adaptation examined. Statistical analyses were performed by using a 3-way ANOVA, 2-way ANOVA, and the independent samples t test (α=.05). RESULTS: ManE displayed better mean ±standard deviation internal adaptation (182 ±59 µm) than MaxE (215 ±55 µm) (P<.01). Regardless of the groups, the pulpal floor was the area with the poorest fit (P<.001). The marginal gap of mandibular molars (91 ±20 µm) was lower than that of maxillary molars (110 ±26 µm) (P<.05). The effect of modifying endocrowns on the marginal gap was not found to be statistically significant (P>.05). CONCLUSIONS: Internal and marginal adaptation of endocrowns differ between maxillary and mandibular molars.


Assuntos
Coroas , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Porcelana Dentária , Planejamento de Prótese Dentária/métodos , Teste de Materiais , Dente Molar/diagnóstico por imagem , Microtomografia por Raio-X
15.
Arch Microbiol ; 203(1): 269-277, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32918096

RESUMO

Bacterial biofilms are related to various dental and periodontal infectious diseases, and the characterization of this biological structure with micro-computed tomography (micro-CT) may offer valuable information for clinical and research applications. In this study, we aimed to develop a model to visualize three-dimensionally the biofilm structure on dentin using micro-CT. Dentin blocks were prepared and incubated in tryptic soy broth with Enterococcus faecalis (ATCC 29212). The control group did not receive any staining procedure, while groups 1 and 2 were stained with 100% and 50% barium sulfate, respectively. Transmission electron microscopy (TEM) and confocal laser scanning microscopy (CLSM) were used to detect biofilm formation, barium sulfate penetration, and microbial cell density in the biofilm. Micro-computed tomography (micro-CT) (SkyScan 1172, Bruker Co., Belgium) was used to visualize biofilm formation on the dentin blocks. Biofilm thicknesses were measured from 10 different locations on the specimen surfaces, using CTAn v.1.14.4 software. Obtained data were statistically analyzed using Kruskal-Wallis and Dunn's tests. TEM photomicrographs showed that barium sulfate could penetrate the biofilm structure. CLSM analysis showed that viable and total cell densities were similar between the control and barium sulfate-treated groups (P > 0.05), indicating barium sulfate had no significant influence on cell density. In barium sulfate-treated blocks, biofilm could be discriminated from the dentin, and its thickness could be measured with micro-CT. This study showed that bacterial biofilm on dentin could be characterized by micro-CT after barium sulfate staining without causing any significant side effect on viable and total cell densities.


Assuntos
Biofilmes , Dentina/microbiologia , Enterococcus faecalis/fisiologia , Enterococcus faecalis/ultraestrutura , Animais , Bovinos , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Microtomografia por Raio-X
16.
Graefes Arch Clin Exp Ophthalmol ; 259(1): 53-60, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32813109

RESUMO

PURPOSE: To determine the vitreous levels of vascular endothelial growth factor (VEGF), stromal cell-derived factor-1α (SDF-1α) and angiopoietin-like protein 2 (ANGPTL2) in patients with active proliferative diabetic retinopathy (PDR), and to ascertain their contribution on different clinical presentation of active PDR. METHODS: This case-control study included 31 eyes with active PDR and 10 eyes with idiopathic macular hole (MH) (control group). Eyes with active PDR were divided into three subgroups: vitreous hemorrhage (VH), tractional retinal detachment (TRD) caused by active fibrovascular membrane (FVM), and coexistence of VH and TRD with FVM. Vitreous samples obtained during vitrectomy were analyzed for concentrations of VEGF, SDF-1α, and ANGPTL2. RESULTS: Vitreous level of VEGF (2021 (168-6550) pg/ml vs 110.1 (74.5-236) pg/ml), SDF-1α (517 (194-1044) pg/ml vs 388 (320-535) pg/ml), and ANGPTL2 (725 (131-1590) ng/ml vs 196 (75.9-437) ng/ml) were significantly higher in eyes with active PDR than in control group (p < 0.001, p = 0.002, and p < 0.001, respectively). The concentrations of these meaditors in each active PDR subgroups were also significantly higher than control group (p < 0.05). The vitreous level of ANGPTL2 was significantly higher in eyes with TRD caused by FVM (1033 ± 401 ng/ml) than in eyes with VH (561 ± 237 ng/ml; p = 0.008). CONCLUSION: High levels of SDF-1α, ANGPTL2 and particularly VEGF seem to be associated with PDR. Since the vitreous levels of ANGPTL2 tend to be higher in eyes with active fibrovascular tractional detachment, vitreous levels of this chemokine seem to be affected by the clinical presentation of vascularly active PDR eyes.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Proteína 2 Semelhante a Angiopoietina , Proteínas Semelhantes a Angiopoietina , Estudos de Casos e Controles , Quimiocina CXCL12 , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/cirurgia , Ensaio de Imunoadsorção Enzimática , Humanos , Células Estromais , Fator A de Crescimento do Endotélio Vascular , Vitrectomia , Corpo Vítreo
17.
Clin Oral Investig ; 25(7): 4407-4413, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33392806

RESUMO

OBJECTIVES: This study evaluated the efficacy of 5% and 10% glycolic acid solutions for the removal of calcium hydroxide medicament from artificial internal resorption cavities. MATERIALS AND METHODS: A total of 170 human maxillary premolars were selected and artificial internal resorption cavities were prepared using round burs and 37% orthophosphoric acid in the apical third of the root halves. Entire canal and resorption cavity were filled with calcium hydroxide paste. Then, the specimens were assigned to 2 control groups or ten experimental groups according to the irrigating solutions used for medicament removal with and without activation with ultrasonic energy as following: 5% glycolic acid, 10% glycolic acid, 17% EDTA, and 10% citric acid and distilled water. The resorption cavities were examined under different magnifications using stereomicroscopy and scanning electron microscopy (SEM). The calcium hydroxide remnants in the resorption cavity were scored by 2 evaluators using a 4-scoring scale. The data were analyzed with Kruskal-Wallis H tests with 5% significance threshold. RESULTS: There was no significant difference regarding the distribution of removal scores among non-activated solutions (P > 0.05). In activated groups, 10% glycolic acid irrigation removed significantly more amount of calcium hydroxide than EDTA and distilled water (P < 0.05). No significant difference was found between the efficacy of 10% glycolic and citric acid (P > 0.05). Citric acid, 5% glycolic acid, and EDTA showed similar removal scores (P > 0.05). Passive ultrasonic irrigation significantly improved calcium hydroxide removal scores in 10% glycolic acid, citric acid, and EDTA groups (P < 0.05). The SEM examination revealed that the specimens that were scored 0 are not entirely free of calcium hydroxide remnants. CONCLUSION: Concentration of 10% glycolic acid removed significantly more calcium hydroxide paste from resorption cavities than EDTA when used with passive ultrasonic irrigation. Although passive ultrasonic irrigation favored medicament removal in all irrigating solutions, complete elimination of medicament remnants was unattainable. CLINICAL RELEVANCE: This study showed the improved efficacy of ultrasonically activated 10% glycolic acid in removing the calcium hydroxide medicament from the internal resorption cavity.


Assuntos
Hidróxido de Cálcio , Irrigantes do Canal Radicular , Cavidade Pulpar , Ácido Edético , Glicolatos , Humanos , Preparo de Canal Radicular , Irrigação Terapêutica
18.
Clin Oral Investig ; 25(1): 151-157, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32542583

RESUMO

OBJECTIVE: The aim of this study was to compare the cyclic fatigue resistance at body temperature and phase transformation behaviors of novel Rotate instrument (25.06) with rotating Mtwo (25.06) and reciprocating Reciproc Blue (25.08) and Reciproc (25.08) instruments. MATERIALS AND METHODS: The Rotate, Reciproc Blue, Reciproc, and Mtwo instruments free of visible deformations were collected and tested in a static cyclic fatigue test method, which has a ceramic block containing an artificial canal with 60° angle of curvature and a 5-mm radius of curvature at 37 °C (n = 16). All instruments were operated until fracture occurred, and both time to fracture (TF) and the lengths of the fractured fragments were recorded. TF data was analyzed with one-way ANOVA followed by post hoc Tukey tests and Weibull analysis, and fractured fragment length data were subjected to one-way ANOVA and post hoc Tukey tests (P < 0.05). Two unused instruments from each brand were also subjected to differential scanning calorimetry (DSC) analysis to determine their phase transformation temperatures. RESULTS: The Reciproc Blue instruments showed significantly higher TF values and reliability than the other groups (P < 0.05). Rotate instruments exhibited greater cyclic fatigue resistance than the Reciproc and Mtwo instruments (P < 0.05). No significant difference was detected among the fractured fragment lengths (P > 0.05). The lowest austenite finish temperature was exhibited by the Mtwo, which presented a single transformation peak, followed by the Rotate, Reciproc Blue, and Reciproc instruments which all presented two peaks during transformation. CONCLUSIONS: Cyclic fatigue resistance of instruments manufactured from thermally treated Blue wire instruments was superior to those of the Mtwo and Reciproc, whereas reciprocating the Blue wire showed the highest resistance. CLINICAL RELEVANCE: The present study compared the cyclic fatigue resistance of the novel Rotate instrument with similar instruments manufactured from conventional nickel-titanium, m-wire, and Blue wire at body temperature and reported that Blue-treated instruments exhibited superior cyclic fatigue resistance.


Assuntos
Instrumentos Odontológicos , Níquel , Temperatura Corporal , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Reprodutibilidade dos Testes , Preparo de Canal Radicular , Estresse Mecânico , Temperatura , Titânio
19.
Acta Odontol Scand ; 79(2): 156-160, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33245674

RESUMO

OBJECTIVE: The aim of this study was to investigate temperature and time variations during root-end resection. MATERIAL AND METHODS: Sixty human premolars were selected. The root canals were enlarged up to ProTaper X3 rotary instrument. A thermocouple was placed into the root canal 1 mm behind the resection line. The teeth were randomly divided into six groups according to the apical resection method: steel bur, tungsten carbide bur, Lindeman bur, diamond bur, laser and ultrasonic surgical piezo with a diamond tip. The root ends were resected 3 mm away from the root apex. The temperature of the root dentine during resection was recorded as maximum temperature, mean temperature and temperature change. The time required for apicectomy was recorded for each group. The Kruskal-Wallis method was used to analyse the differences between temperature changes during apical resections. The significance level was set at 5%. RESULTS: There was no significant difference between bur groups in terms of temperature increase. The maximum temperature in piezo surgery was significantly higher than the Lindeman, tungsten and steel burs (p < .001). In addition, the maximum temperature in laser surgery was higher than the Lindeman bur (p < .05). An increase in the temperature was mostly seen in piezo surgery and the least temperature change occurred in the Lindeman bur. Mean time stayed under 1 min in each group. CONCLUSIONS: Although piezo caused the highest temperature increase, the measured temperature increase was within physiological limits in all tested techniques.


Assuntos
Apicectomia , Cavidade Pulpar , Dente Pré-Molar , Diamante , Humanos , Preparo de Canal Radicular , Temperatura
20.
Turk J Med Sci ; 31(2)2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33705644

RESUMO

Ahead of Print article withdrawn by publisher.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA