RESUMO
Background: In the frame of elimination strategies of Plasmodium falciparum (Pf), active case detection has been recommended as complementary approach to the existing passive case detection programs. We trialed a polymerase chain reaction (PCR)-based active detection strategy targeting asymptomatic individuals, named proactive case detection (PACD), with the aim of assessing its feasibility, the extra yield of Pf infections, and the at-risk population for Pf carriage status. Methods: A pilot of PACD was conducted in 3 villages in Chey Saen district (Preah Vihear province, Cambodia), from December 2015 to March 2016. Voluntary screening and treatment, following health promotion sensitization, was used as mobilization strategy. Results: A total of 2802 persons were tested, representing 54% of the population. PACD (n = 30) and the respective reactive case detection (RACD) (n = 3) identified 33 Pf carriers, approximately twice as many as the Pf infections (n = 17) diagnosed in passive case detection and respective RACD, by health centers and village malaria workers using PCR, in the same villages/period. Final positivity rate was 1.07% (30/2802). People spending nighttime in forests and plantations were found to be at increased risk for Pf infection (odds ratio [OR], 3.4 [95% CI, 1.6-7.2], P = .002 and OR, 2.3 [95% CI, 1.1-4.9], P = .03, respectively). Conclusions: We demonstrated the usefulness of the PACD component in identifying Pf asymptomatic carriers. Social mobilization and promotion led to good attendance of specific risk groups, identified to be, in the Cambodian context, individuals spending nighttime in forest and plantations.
Assuntos
Malária Falciparum/epidemiologia , Malária Falciparum/transmissão , Plasmodium falciparum , Adolescente , Adulto , Antimaláricos/uso terapêutico , Artemisininas/administração & dosagem , Artemisininas/uso terapêutico , Camboja , Portador Sadio , Criança , Pré-Escolar , Reservatórios de Doenças , Feminino , Humanos , Malária Falciparum/tratamento farmacológico , Malária Falciparum/parasitologia , Masculino , Pessoa de Meia-Idade , Comitê de Farmácia e Terapêutica , Projetos Piloto , Primaquina/administração & dosagem , Primaquina/uso terapêutico , Quinolinas/administração & dosagem , Quinolinas/uso terapêutico , Fatores de Risco , Adulto JovemRESUMO
BACKGROUND: Given the risk of artemisinin resistance spreading from the Greater Mekong sub-region, prospective monitoring in sub-Saharan Africa should be expedited. Molecular biology techniques used for monitoring rely on the detection of k13 validated mutants by using PCR and Sanger sequencing approach, usually not available in malaria endemic areas. METHODS: A semi-automated workflow based on the easyMAG® platform and the Argene Solution® (bioMérieux, Marcy l'Etoile, France) as a field-based surveillance tool operable at national level was developed in four steps. Clinical and analytical performances of this tool detecting five of the most frequent and validated k13 mutants (Y493H, I543T, R539T, F446I and C580Y) from dried blood spots (DBS) were compared to the gold standard approach (PCR and Sanger sequencing). RESULTS: By using the ARMS (amplification-refractory mutation system) strategy, the best multiplexing options were found in 3 separate real-time PCR duplexes (IC as internal control/I543T, C580Y/Y493H and F446I/R539T) with limits of detection ranging from 50 (C580Y) to 6.25 parasites/µL (Y493H). In field conditions, using 642 clinical DBS (from symptomatic patients and asymptomatic individuals) collected from Cambodia, Myanmar and Africa (Chad), the overall sensitivity and specificity of the K13 bMx prototype assay developed by bioMérieux were ≥ 90%. Areas under the ROC curves were estimated to be > 0.90 for all k13 mutants in samples from symptomatic patients. CONCLUSION: The K13 ready-to-use bMx prototype assay, considered by the end-users as a user-friendly assay to perform (in shorter time than the K13 reference assay) and easy to interpret, was found to require less budget planning and had fewer logistical constraints. Its excellent performance qualifies the prototype as a reliable screening tool usable in malaria endemic countries recognized to be at risk of emergence or spread of validated k13 mutants. Additional multi-site studies are needed to evaluate the performances of the K13 bMx prototype assay in different epidemiological contexts such as Africa, India, or South America.
Assuntos
Artemisininas/farmacologia , Resistência a Medicamentos , Malária Falciparum/diagnóstico , Plasmodium falciparum/efeitos dos fármacos , Vigilância da População/métodos , Proteínas de Protozoários/análise , Camboja/epidemiologia , Chade/epidemiologia , Resistência a Medicamentos/genética , Humanos , Malária Falciparum/epidemiologia , Mutação , Mianmar/epidemiologia , Plasmodium falciparum/genéticaRESUMO
BACKGROUND: The declining efficacy of dihydroartemisinin-piperaquine against Plasmodium falciparum in Cambodia, along with increasing numbers of recrudescent cases, suggests resistance to both artemisinin and piperaquine. Available in vitro piperaquine susceptibility assays do not correlate with treatment outcome. A novel assay using a pharmacologically relevant piperaquine dose/time exposure was designed and its relevance explored in retrospective and prospective studies. METHODS: The piperaquine survival assay (PSA) exposed parasites to 200 nM piperaquine for 48 hours and monitored survival 24 hours later. The retrospective study tested 32 culture-adapted, C580Y-K13 mutant parasites collected at enrolment from patients treated with a 3-day course of dihydroartemisinin-piperaquine and having presented or not with a recrudescence at day 42 (registered ACTRN12615000793516). The prospective study assessed ex vivo PSA survival rate alongside K13 polymorphism of isolates collected from patients enrolled in an open-label study with dihydroartemisinin-piperaquine for uncomplicated P. falciparum malaria in Cambodia (registered ACTRN12615000696594). RESULTS: All parasites from recrudescent cases had in vitro or ex vivo PSA survival rates ≥10%, a relevant cut-off value for piperaquine-resistance. Ex vivo PSA survival rates were higher for recrudescent than non-recrudescent cases (39.2% vs. 0.17%, P <1 × 10(-7)). Artemisinin-resistant K13 mutants with ex vivo PSA survival rates ≥10% were associated with 32-fold higher risk of recrudescence (95% CI, 4.5-224; P = 0.0005). CONCLUSION: PSA adequately captures the piperaquine resistance/recrudescence phenotype, a mainstay to identify molecular marker(s) and evaluate efficacy of alternative drugs. Combined ex vivo PSA and K13 genotyping provides a convenient monitor for both artemisinin and piperaquine resistance where dihydroartemisinin-piperaquine is used.
Assuntos
Artemisininas/farmacologia , Plasmodium falciparum/genética , Quinolinas/farmacologia , Adolescente , Adulto , Animais , Antimaláricos/uso terapêutico , Camboja , Feminino , Humanos , Malária Falciparum/tratamento farmacológico , Malária Falciparum/mortalidade , Masculino , Parasitos , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida , Falha de Tratamento , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: To achieve the goal of malaria elimination in low transmission areas such as in Cambodia, new, inexpensive, high-throughput diagnostic tools for identifying very low parasite densities in asymptomatic carriers are required. This will enable a switch from passive to active malaria case detection in the field. METHODS: DNA extraction and real-time PCR assays were implemented in an "in-house" designed mobile laboratory allowing implementation of a robust, sensitive and rapid malaria diagnostic strategy in the field. This tool was employed in a survey organized in the context of the MalaResT project (NCT01663831). RESULTS: The real-time PCR screening and species identification assays were performed in the mobile laboratory between October and November 2012, in Rattanakiri Province, to screen approximately 5,000 individuals in less than four weeks and treat parasite carriers within 24-48 hours after sample collection. An average of 240 clinical samples (and 40 quality control samples) was tested every day, six/seven days per week. Some 97.7% of the results were available <24 hours after the collection. A total of 4.9% were positive for malaria. Plasmodium vivax was present in 61.1% of the positive samples, Plasmodium falciparum in 45.9%, Plasmodium malariae in 7.0% and Plasmodium ovale in 2.0%. CONCLUSIONS: The operational success of this diagnostic set-up proved that molecular testing and subsequent treatment is logistically achievable in field settings. This will allow the detection of clusters of asymptomatic carriers and to provide useful epidemiological information. Fast results will be of great help for staff in the field to track and treat asymptomatic parasitaemic cases. The concept of the mobile laboratory could be extended to other countries for the molecular detection of malaria or other pathogens, or to culture vivax parasites, which does not support long-time delay between sample collection and culture.
Assuntos
Portador Sadio/diagnóstico , Malária/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Parasitologia/métodos , Plasmodium/classificação , Plasmodium/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecções Assintomáticas , Camboja/epidemiologia , Portador Sadio/parasitologia , Estudos Transversais , Humanos , Malária/epidemiologia , Malária/parasitologia , Programas de Rastreamento/métodos , Epidemiologia Molecular/métodos , Plasmodium/genética , Sensibilidade e Especificidade , Fatores de TempoRESUMO
BACKGROUND: Western Cambodia is the epicentre of Plasmodium falciparum multidrug resistance and is facing high rates of dihydroartemisinin-piperaquine treatment failures. Genetic tools to detect the multidrug-resistant parasites are needed. Artemisinin resistance can be tracked using the K13 molecular marker, but no marker exists for piperaquine resistance. We aimed to identify genetic markers of piperaquine resistance and study their association with dihydroartemisinin-piperaquine treatment failures. METHODS: We obtained blood samples from Cambodian patients infected with P falciparum and treated with dihydroartemisinin-piperaquine. Patients were followed up for 42 days during the years 2009-15. We established in-vitro and ex-vivo susceptibility profiles for a subset using piperaquine survival assays. We determined whole-genome sequences by Illumina paired-reads sequencing, copy number variations by qPCR, RNA concentrations by qRT-PCR, and protein concentrations by immunoblotting. Fisher's exact and non-parametric Wilcoxon rank-sum tests were used to identify significant differences in single-nucleotide polymorphisms or copy number variants, respectively, for differential distribution between piperaquine-resistant and piperaquine-sensitive parasite lines. FINDINGS: Whole-genome exon sequence analysis of 31 culture-adapted parasite lines associated amplification of the plasmepsin 2-plasmepsin 3 gene cluster with in-vitro piperaquine resistance. Ex-vivo piperaquine survival assay profiles of 134 isolates correlated with plasmepsin 2 gene copy number. In 725 patients treated with dihydroartemisinin-piperaquine, multicopy plasmepsin 2 in the sample collected before treatment was associated with an adjusted hazard ratio (aHR) for treatment failure of 20·4 (95% CI 9·1-45·5, p<0·0001). Multicopy plasmepsin 2 predicted dihydroartemisinin-piperaquine failures with 0·94 (95% CI 0·88-0·98) sensitivity and 0·77 (0·74-0·81) specificity. Analysis of samples collected across the country from 2002 to 2015 showed that the geographical and temporal increase of the proportion of multicopy plasmepsin 2 parasites was highly correlated with increasing dihydroartemisinin-piperaquine treatment failure rates (r=0·89 [95% CI 0·77-0·95], p<0·0001, Spearman's coefficient of rank correlation). Dihydroartemisinin-piperaquine efficacy at day 42 fell below 90% when the proportion of multicopy plasmepsin 2 parasites exceeded 22%. INTERPRETATION: Piperaquine resistance in Cambodia is strongly associated with amplification of plasmepsin 2-3, encoding haemoglobin-digesting proteases, regardless of the location. Multicopy plasmepsin 2 constitutes a surrogate molecular marker to track piperaquine resistance. A molecular toolkit combining plasmepsin 2 with K13 and mdr1 monitoring should provide timely information for antimalarial treatment and containment policies. FUNDING: Institut Pasteur in Cambodia, Institut Pasteur Paris, National Institutes of Health, WHO, Agence Nationale de la Recherche, Investissement d'Avenir programme, Laboratoire d'Excellence Integrative "Biology of Emerging Infectious Diseases".
Assuntos
Antimaláricos/uso terapêutico , Artemisininas/uso terapêutico , Biomarcadores/metabolismo , Estudos de Associação Genética , Malária Falciparum/tratamento farmacológico , Quinolinas/uso terapêutico , Ácido Aspártico Endopeptidases , Camboja , Variações do Número de Cópias de DNA/genética , Resistência a Múltiplos Medicamentos , Humanos , Plasmodium falciparum/genética , Plasmodium falciparum/isolamento & purificação , Falha de TratamentoRESUMO
In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 µL) and different volumes of venous blood (50 µL, 200 µL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 µL, 200 µL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, â¼100-fold lower than 5 µL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 µL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas.