Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 26(10): 12801-12812, 2018 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-29801315

RESUMO

This paper reports design, fabrication, and experimental demonstration of a silicon nitride photonic integrated circuit (PIC). The PIC is capable of conducting one-dimensional interferometric imaging with twelve baselines near λ = 1100-1600 nm. The PIC consists of twelve waveguide pairs, each leading to a multi-mode interferometer (MMI) that forms broadband interference fringes or each corresponding pair of the waveguides. Then an 18 channel arrayed waveguide grating (AWG) separates the combined signal into 18 signals of different wavelengths. A total of 103 sets of fringes are collected by the detector array at the output of the PIC. We keep the optical path difference (OPD) of each interferometer baseline to within 1 µm to maximize the visibility of the interference measurement. We also constructed a testbed to utilize the PIC for two-dimension complex visibility measurement with various targets. The experiment shows reconstructed images in good agreement with theoretical predictions.

2.
Opt Express ; 25(11): 12653-12665, 2017 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-28786620

RESUMO

This paper reports design, fabrication, and demonstration of a silica photonic integrated circuit (PIC) capable of conducting interferometric imaging with multiple baselines around λ = 1550 nm. The PIC consists of four sets of five waveguides (total of twenty waveguides), each leading to a three-band spectrometer (total of sixty waveguides), after which a tunable Mach-Zehnder interferometer (MZI) constructs interferograms from each pair of the waveguides. A total of thirty sets of interferograms (ten pairs of three spectral bands) is collected by the detector array at the output of the PIC. The optical path difference (OPD) of each interferometer baseline is kept to within 1 µm to maximize the visibility of the interference measurement. We constructed an experiment to utilize the two baselines for complex visibility measurement on a point source and a variable width slit. We used the point source to demonstrate near unity value of the PIC instrumental visibility, and used the variable slit to demonstrate visibility measurement for a simple extended object. The experimental result demonstrates the visibility of baseline 5 and 20 mm for a slit width of 0 to 500 µm in good agreement with theoretical predictions.

3.
Opt Express ; 17(14): 11638-51, 2009 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-19582079

RESUMO

The performance of long distance imaging systems is typically degraded by phase errors imparted by atmospheric turbulence. In this paper we apply coherent imaging methods to determine, and remove, these phase errors by digitally processing coherent recordings of the image data. In this manner we are able to remove the effects of atmospheric turbulence without needing a conventional adaptive optical system. Digital holographic detection is used to record the coherent, complex-valued, optical field for a series of atmospheric and object realizations. Correction of atmospheric phase errors is then based on maximizing an image sharpness metric to determine the aberrations present and correct the underlying image. Experimental results that demonstrate image recovery in the presence of turbulence are presented. Results obtained with severe turbulence that gives rise to anisoplanatism are also presented.


Assuntos
Holografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Atmosfera , Gráficos por Computador , Apresentação de Dados , Desenho de Equipamento , Análise de Fourier , Holografia/instrumentação , Armazenamento e Recuperação da Informação/métodos , Modelos Estatísticos , Oscilometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA