Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2057-2065, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38407592

RESUMO

PURPOSE: The aim of our study was to evaluate changes in the retinal and choriocapillaris circulations in patients with hypothalamic amenorrhea. METHODS: Prospective, cross-sectional observational study on 25 patients (50 eyes) diagnosed with hypothalamic amenorrhea and 25 age-matched healthy women. Optical coherence tomography angiography (OCTA) was used to evaluate the vessel density (VD) of superficial capillary plexus (SCP), deep capillary plexus (DCP), and choriocapillaris VD layers in whole 6.4 × 6.4-mm image and in fovea grid-based image. In patients' group, systemic parameters were collected: body mass index (BMI), endometrial rhyme thickness, follicle stimulating hormone (FSH), luteinizing hormone (LH), prolactin, insulin, and cortisol. RESULTS: SCP and DCP did not show any statistical difference when comparing patients and controls (all p > 0.05). Differently, choriocapillaris VD in the whole region showed a non-significant tendency toward higher values in the patients group in both eyes (p = 0.038 for right eye [RE], p = 0.044 for left eye [LE]). Foveal choriocapillaris VD was higher in hypothalamic amenorrhea women vs. healthy controls (66.0 ± 2.4 vs. 63.7 ± 6.6%, p = 0.136 for RE; 65.0 ± 2.4 vs. 61.6 ± 7.0%, p = 0.005 for LE). Focusing on correlation with systemic parameters, SCP and DCP foveal density had a medium/high effect size with endometrial rhyme, along with DCP in the fovea area vs. cortisol and SCP in the whole area vs. FSH. CONCLUSION: When comparing hypothalamic amenorrhea patients to healthy subjects, OCTA detected changes in the choriocapillaris layer, showing increased VD in the early stage of the systemic pathology, suggesting that microvascular "compaction" could be a first phase of hypoestrogenism adaptation.


Assuntos
Amenorreia , Biomarcadores , Corioide , Angiofluoresceinografia , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Estudos Prospectivos , Amenorreia/diagnóstico , Amenorreia/fisiopatologia , Amenorreia/etiologia , Amenorreia/sangue , Corioide/irrigação sanguínea , Angiofluoresceinografia/métodos , Adulto , Adulto Jovem , Biomarcadores/sangue , Fundo de Olho , Doenças Hipotalâmicas/diagnóstico , Doenças Hipotalâmicas/fisiopatologia , Doenças Hipotalâmicas/complicações , Capilares , Adolescente
2.
Ophthalmol Sci ; 4(6): 100476, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39149709

RESUMO

Purpose: To evaluate the safety of subretinal injection of cord blood platelet-rich plasma (CB-PRP) and its possible effect in eyes affected by geographic atrophy (GA) associated with dry age-related macular degeneration (d-AMD). Design: Interventional, open-label study started in January 2021 with follow-up at 12 months (the Si.Cord Study). This study was a single-center, nonrandomized, sequential-assigned clinical trial conducted in Rome, Italy, at Fondazione Policlinico Universitario Agostino Gemelli IRCCS (ClinicalTrials.gov NCT04636853). Participants: Thirteen patients (26 eyes) with bilateral d-AMD-related GA were enrolled. One eye from each patient (with more advanced GA) underwent CB-PRP treatment, and the fellow eye was considered the control. All patients participated in follow-up at 12 months. Intervention: All 13 eyes received 23-gauge (G) vitrectomy and subretinal injection of CB-PRP using a 41-gauge needle. Main Outcomes and Measures: Best-corrected visual acuity (BCVA) with ETDRS letters, central macular thickness using OCT, and atrophic area measured on en face OCT images were assessed at baseline, 1, 3, 6, and 12 months. Results: The BCVA in the treated group was 34.46 ± 20.8 ETDRS at baseline, 40.84 ± 20.52 at 1 month, 40.07 ± 20.34 at 3 months, 39.38 ± 19.84 at 6 months, and 35.84 ± 18.38 at 12 months. In the untreated group, the BCVA was 53 ± 21.1 ETDRS letters at baseline, 51.54 ± 20.99 at 1 month, 46.62 ± 19.47 at 3 months, 46.85 ± 18.58 at 6 months, and 43.92 ± 17.97 at 12 months (2-way analysis of variance: interaction of treatment by eye or time, P = 0.084). Central macular thickness did not show a significant intereye difference at 12 months (P = 0.97). The atrophic geographic areas tended to increase in both treated and fellow eyes at 12 months (P < 0.0001). No inflammatory reaction, endophthalmitis, retinal detachment, uveitis, or other complications due to the subretinal injection of CB-PRP were observed during the follow-up. Conclusions: Subretinal injection of CB-PRP could be safely used for d-AMD in its GA form. Despite its safety, a larger cohort of patients, and probably a new way of administration, will be needed to understand whether the CB-PRP could have a role in the GA treatment. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

3.
Eur J Ophthalmol ; 33(6): 2303-2308, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37437594

RESUMO

BACKGROUND: To describe the efficacy and safety of the adjustable system eyeWatch in vitrectomized glacomatous eyes. METHODS: Prospective, non-comparative, small case series of 2 patients who underwent glaucoma drainage device implant with the eyeWatch system. Intraocular pressure, number of medications and early and late complications were evaluated. RESULTS: None of the operated eyes developed early or late complications. After 1 week post operatively, the IOP raised at 28 mmHg in the first eye and 25 mmHg in the second one. The eyeWatch Pen was used to open and set the device into position 3 (that means implant half opened) After waiting for 30 min, IOP was 15 mmHg and 11 mmHg, respectively. Thirty days after surgery we set the EyeWatch into position 0 (that means implant full opened) even though the IOP was under control. A new IOP measurement was done and we registered that IOP was 14 mmHg and 10 mmHg respectively, and it remained stable after six months of follow up. CONCLUSION: In conclusion, in our case series the use of eyeWatch adjustable system allows a safe and gradual regulation of the flow during post-operative management also in vitrectomized eyes. Considering the percentage of hypotony related complications in vitrectomized eyes this system is an effective and safe technique to handle glaucoma in post vitreoretinal surgery eyes.

4.
Diagnostics (Basel) ; 11(10)2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34679448

RESUMO

There is no consensus on whether amblyopia affects the retinal vascular plexus and morphology. Previous studies focused on the differences between amblyopic patients and normal controls without evaluating amblyopic eyes after patching. To evaluate differences in the superficial vascular density of amblyopic eyes, normal eyes, and amblyopic eyes reaching normal BCVA after patch therapy, OCTA was used. All patients underwent a comprehensive ophthalmological examination, including visual acuity, refraction, ocular motility tests, and anterior and posterior segment examination. OCTA was performed by an expert physician using the Zeiss Cirrus 5000-HD-OCT Angioplex (Carl Zeiss, Meditec, Inc., Dublin, OH, USA). OCTA scans were performed using a 3 × 3 mm2 and 6 × 6 mm2 fovea-centered image setting. The mean outer macular vessel density in the previously amblyopic group was 19.15 ± 0.51%. This was statistically significantly higher than in both the amblyopic group (18.70 ± 1.14%) and the normal controls (18.18 ± 1.40%) (p = 0.014). The previously amblyopic group also significantly differed from both normal controls and amblyopic eyes with regards to the inner (p = 0.011), outer (p = 0.006), and full (p = 0.003) macular perfusion. Finally, linear regression analysis revealed that BCVA was linearly correlated to outer perfusion in amblyopic (p = 0.003) and ex amblyopic eyes (p < 0.001). Considering the cross-sectional nature of our study, from our results, we can only hypothesize a possible correlation between light stimulation and retinal vasculature development. However, further longitudinal studies are needed to support this hypothesis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA