Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomacromolecules ; 12(11): 3997-4010, 2011 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-21955116

RESUMO

We describe the synthesis of metal-chelating polymers (MCPs) with four different pendant polyaminocarboxylate ligands (EDTA, DTPA, TTHA, DOTA) and an orthogonal end-group, either a fluorescein molecule or a bismaleimide linker for antibody attachment. Polymer characterization by a combination of (1)H NMR, UV/vis absorption measurements, and thermal gravimetric analysis (TGA) indicated that each chain of the fluorescein-terminated polymers contained one dye molecule. These polymer samples were loaded with three different types of lanthanide ions as well as palladium and platinum ions. The numbers of metal atoms per chain were determined by a combination of UV/vis and conventional ICP-MS measurements. The experiments with lanthanide ions demonstrated that a net anionic charge on the polymer is important for water solubility. These experiments also showed that at least one type of lanthanide ion (La(3+)) is capable of forming a bimetallic complex with pendant DTPA groups. Conditions were developed for loading these polymers with palladium and platinum ions. While these polymers could be conjugated to antibodies, the presence of Pd or Pt ions in the polymer interfered with the ability of the antibody to recognize its antigen. For example, a goat anti-mouse (secondary) antibody labeled with polymers that contain Pd or Pt no longer recognized a primary antibody in a sandwich assay. In mass cytometry assays, these Pd- or Pt-containing MCPs were very effective in recognizing dead cells and provide a new and robust assay for distinguishing live cells from dead cells.


Assuntos
Complexos de Coordenação/síntese química , Paládio/química , Platina/química , Polímeros/síntese química , Apoptose , Linhagem Celular , Complexos de Coordenação/química , Citometria de Fluxo , Fluoresceína/química , Corantes Fluorescentes/química , Humanos , Elementos da Série dos Lantanídeos/química , Espectrometria de Massas , Polímeros/química , Coloração e Rotulagem , Termogravimetria
2.
J Anal At Spectrom ; 25(3): 260-268, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20390041

RESUMO

We examine the suitability of metal-containing polystyrene beads for the calibration of a mass cytometer instrument, a single particle analyser based on an inductively coupled plasma ion source and a time of flight mass spectrometer. These metal-containing beads are also verified for their use as internal standards for this instrument. These beads were synthesized by multiple-stage dispersion polymerization with acrylic acid as a comonomer. Acrylic acid acts as a ligand to anchor the metal ions within the interior of the beads. Mass cytometry enabled the bead-by-bead measurement of the metal-content and determination of the metal-content distribution. Beads synthesized by dispersion polymerization that involved three stages were shown to have narrower bead-to-bead variation in their lanthanide content than beads synthesized by 2-stage dispersion polymerization. The beads exhibited insignificant release of their lanthanide content to aqueous solutions of different pHs over a period of six months. When mixed with KG1a or U937 cell lines, metal-containing polymer beads were shown not to affect the mass cytometry response to the metal content of element-tagged antibodies specifically attached to these cells.

3.
Anal Chem ; 81(16): 6813-22, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19601617

RESUMO

A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing dc quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 micros duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions (<3% cerium oxide ratio). At mass resolution (full width at half-maximum) M/DeltaM > 900 for m/z = 159, the sensitivity with a standard sample introduction system of >1.4 x 10(8) ion counts per second per mg L(-1) of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When <15 elemental tags are used, a higher sensitivity mode at lower resolution (M/DeltaM > 500) can be used, which provides >2.4 x 10(8) cps per mg L(-1) of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 microm polystyrene beads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.


Assuntos
Separação Celular/métodos , Imunoensaio/métodos , Espectrometria de Massas/métodos , Anticorpos/análise , Anticorpos/imunologia , Antígenos/análise , Antígenos/imunologia , Separação Celular/instrumentação , Imunoensaio/instrumentação , Limite de Detecção , Espectrometria de Massas/instrumentação
4.
J Immunol Methods ; 336(1): 56-63, 2008 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-18456275

RESUMO

We have investigated the possibility of using element-tagged antibodies for protein detection and quantification in microplate format using Inductively Coupled Plasma Mass Spectrometry (ICP-MS), and compared the results to conventional immunoassays, such as Enzyme-Linked Immunosorbent Assay (ELISA) and Western blotting. The technique was further employed to detect low levels and measure DNA-binding activity of transcription factor p53 in leukemia cell lysates through its interaction with immobilized oligonucleotides and recognition by element-tagged antibodies. The advantages of ICP-MS detection for routine performance of immunoassays include increased sensitivity, wide dynamic range, minimal interference from complex matrices, and high throughput. Our approach advances the ICP-MS technology and demonstrates its applicability to proteomic studies through the use of antibodies directly labeled with polymer tags bearing multiple atoms of lanthanides. Development of this novel methodology will enable fast and quantitative identification of multiple analytes in a single well.


Assuntos
Anticorpos Monoclonais/química , Imunoensaio/métodos , Elementos da Série dos Lantanídeos/química , Espectrometria de Massas/métodos , Proteína Supressora de Tumor p53/metabolismo , Western Blotting , DNA/metabolismo , Ensaio de Imunoadsorção Enzimática , Humanos , Células K562 , Fator de Crescimento Derivado de Plaquetas/análise , Proteína Supressora de Tumor p53/análise
5.
Mol Syst Biol ; 3: 89, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17353931

RESUMO

Mapping protein-protein interactions is an invaluable tool for understanding protein function. Here, we report the first large-scale study of protein-protein interactions in human cells using a mass spectrometry-based approach. The study maps protein interactions for 338 bait proteins that were selected based on known or suspected disease and functional associations. Large-scale immunoprecipitation of Flag-tagged versions of these proteins followed by LC-ESI-MS/MS analysis resulted in the identification of 24,540 potential protein interactions. False positives and redundant hits were filtered out using empirical criteria and a calculated interaction confidence score, producing a data set of 6463 interactions between 2235 distinct proteins. This data set was further cross-validated using previously published and predicted human protein interactions. In-depth mining of the data set shows that it represents a valuable source of novel protein-protein interactions with relevance to human diseases. In addition, via our preliminary analysis, we report many novel protein interactions and pathway associations.


Assuntos
Proteínas/metabolismo , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Imunoprecipitação , Ligação Proteica
6.
J Anal At Spectrom ; 23(4): 463-469, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19122859

RESUMO

Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

7.
Chem Biol ; 10(10): 989-95, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14583265

RESUMO

The structure of the antifungal drug 5-hydroxy-4-oxonorvaline (HON) in complex with its target homoserine dehydrogenase (HSD) has been determined by X-ray diffraction to 2.6 A resolution. HON shows potent in vitro and in vivo activity against various fungal pathogens despite its weak (2 mM) affinity for HSD in the steady state. The structure together with structure-activity relationship studies, mass spectrometry experiments, and spectroscopic data reveals that the molecular mechanism of antifungal action conferred by HON involves enzyme-dependent formation of a covalent adduct between C4 of the nicotinamide ring of NAD(+) and C5 of HON. Furthermore, novel interactions are involved in stabilizing the (HON*NAD)-adduct, which are not observed in the enzyme's ternary complex structure. These findings clarify the apparent paradox of the potent antifungal actions of HON given its weak steady-state inhibition characteristics.


Assuntos
Ácido Aminolevulínico/farmacologia , Antifúngicos/farmacologia , Homosserina Desidrogenase/antagonistas & inibidores , Ácido Aminolevulínico/análogos & derivados , Ácido Aminolevulínico/química , Sítios de Ligação , Cristalografia por Raios X , Inibidores Enzimáticos/farmacologia , Homosserina Desidrogenase/química , Homosserina Desidrogenase/metabolismo , Cinética , NAD/química , NAD/metabolismo , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA