1.
Arch Orthop Trauma Surg ; 137(3): 321-331, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28168640

RESUMO

BACKGROUND: Current intramedullary nails with a radius of curvature (ROC) of 1500-2000 mm sometimes cause distal anterior cortical encroachment. Furthermore, clinical data indicate that the proximal nail end is too long for some Asian patients. The objective of our study was to develop a comprehensive 3D measurement protocol that measures both the anatomy of the canal and the proximal region. The protocol was used to obtain measurements from Caucasian and Asian (Japanese and Thai) specimens. MATERIALS AND METHODS: A total of 90 3D bone models representative of hip fracture patients were reconstructed from CT data. RapidForm 2006 was used to generate the reference geometries required for determining radius and angulation of shaft antecurvature as well as measurements of the proximal anatomy. Multiple linear regression analyses were used to determine the relative contribution of height, age, ethnicity, gender, and body side on the total variance. RESULTS: The mean ROC in the natural 3D antecurvature plane was 885 mm overall, 974 mm in Caucasians and 787 mm in Asians. Height, age, ethnicity, gender, and body side significantly predicted ROC (R = 0.53, p = 0.000). The mean values of anteversion measurements for Asians (Japanese: 22.1°; Thai: 22.7°) were significantly larger than those of the Caucasians (14.5°; p = 0.001). There was virtually no difference (p = 0.186) between the measurements pertaining to the length of the proximal nail end between Caucasian and Asian samples. There was no significant difference between the mean neck-to-shaft angles (Caucasian: 126°; Japanese: 128.2°; Thai: 125.7°; p = 0.198 for Asians vs Caucasians). CONCLUSIONS: The developed comprehensive anatomical 3D measurement protocol could serve as standardised approach for anthropometric studies in the future. Our data suggest that the ROC of current nail designs should be reduced from between 1500 and 2000 to 1000 mm to achieve an improved fit for the investigated population.


Assuntos
Pinos Ortopédicos , Diáfises/diagnóstico por imagem , Desenho de Equipamento , Fêmur/diagnóstico por imagem , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Antropometria , Povo Asiático , Diáfises/anatomia & histologia , Diáfises/cirurgia , Feminino , Fêmur/anatomia & histologia , Fêmur/cirurgia , Cabeça do Fêmur/anatomia & histologia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Colo do Fêmur/anatomia & histologia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Humanos , Modelos Lineares , Masculino , Tomografia Computadorizada por Raios X , População Branca
2.
Clin Orthop Relat Res ; 467(3): 805-9, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18425558

RESUMO

Inserting the femoral intramedullary alignment rod during total knee arthroplasty (TKA) can generate high intramedullary pressure, which increases the risk of intraoperative complications caused by fat embolism. Despite modifications to the surgical procedure, the best method to prevent this increase in pressure remains unknown. The reamer/irrigator/aspirator is a surgical instrument designed for use during femoral canal entry to increase the canal size and remove intramedullary fat and may prevent this pressure increase. We posed two hypotheses: (1) using the reamer/irrigator/aspirator system will result in lower maximum femoral intramedullary pressure than using only conventional instrumentation during the initial steps of a TKA; and (2) using the reamer/irrigator/aspirator system in the initial steps of TKA will result in a mean maximum intramedullary pressure less than 200 mm Hg. We simulated a TKA on 14 cadaveric femurs to compare the femoral intramedullary pressure using both methods. Considerable decreases in femoral intramedullary pressure of 86% proximally and 87% distally were obtained by using the reamer/irrigator/aspirator system. The mean maximum pressure using the reamer/irrigator/aspirator system was less than 200 mm Hg. Additional clinical studies are needed to confirm any reduction in complications using the reamer/irrigator/aspirator system.


Assuntos
Artroplastia do Joelho/instrumentação , Medula Óssea/cirurgia , Fêmur/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Cadáver , Embolia Gordurosa/etiologia , Embolia Gordurosa/prevenção & controle , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Pressão , Sucção/instrumentação , Irrigação Terapêutica/instrumentação
3.
J Orthop Surg Res ; 11(1): 53, 2016 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-27122018

RESUMO

BACKGROUND: The radius of curvature (ROC) misfit of cephalomedullary nails during anterograde nailing can lead to complications such as distal anterior cortical encroachment. This study quantified the anatomical fit of a new nail with 1.0-m ROC (TFN-ADVANCED(™) Proximal Femoral Nailing System [TFNA]) compared with a nail with 1.5-m ROC (Gamma3 Long Nail R1.5 [Gamma3]). METHODS: We generated 63 three-dimensional models (48 female, 45 right femur) representing the cortical surfaces of the femora (31 Caucasian, 28 Japanese, and 4 Thai). The mean age of the specimens was 77 years (±8.1), and the mean height was 158.5 cm (±9.6). Utilizing a customized software tool, nail fit was determined from the total surface area of nail protrusion from the inner cortex surface and maximum distance of nail protrusion in the axial plane; the position of the distal nail tip within the canal was also determined. RESULTS: Overall, TFNA had both a significantly smaller mean total surface area of nail protrusion (915.8 vs. 1181.6 mm(2); P < 0.05) and a mean maximum distance of nail protrusion in the axial plane (1.9 vs. 2.1 mm; P = 0.007) when compared with Gamma3. The mean total surface area of nail protrusion was significantly smaller with TFNA versus Gamma3 in both the Caucasian (P = 0.0009) and Asian (Japanese and Thai) samples (P = 0.000002); the mean maximum distance of TFNA protrusion was significantly smaller in Asians (P = 0.04), but not in Caucasians (P = 0.08). Most tip positions for both nail types were anterior, but TFNA had a higher number of center positions than Gamma3 (13 vs. 7) and a shift from the far anterior cortex to the center of the medullary canal (overall and in Caucasians). In Asians, the most prominent position was far anterior for both nails. CONCLUSIONS: The 1.0-m ROC TFNA nail resulted in better fit than the 1.5-m ROC Gamma3 nail. Clinical trials and case studies should be conducted in the future to verify if these findings would also result in clinical improvements.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Modelos Anatômicos , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fixação Intramedular de Fraturas/métodos , Humanos , Imageamento Tridimensional/métodos , Masculino , Desenho de Prótese , Ajuste de Prótese/métodos , Software , Tomografia Computadorizada por Raios X/métodos