Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Eur Radiol ; 27(10): 4291-4297, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28349279

RESUMO

OBJECTIVES: To evaluate predictive factors for false-negative diagnosis of percutaneous forceps biopsies in patients suspected of having a malignant biliary obstruction METHODS: Two hundred seventy one consecutive patients with obstructive jaundice underwent percutaneous forceps biopsy. In each patient, three to five specimens (mean, 3.5 specimens) were collected from the lesion. The final diagnosis for each patient was confirmed with pathologic findings at surgery, additional histocytologic data, or clinical and radiologic follow-up. Univariate and multivariate logistic regression analysis was used to identify risk factors associated with false-negative diagnosis. RESULTS: One hundred ninety four of 271 biopsies resulted in correct diagnoses of malignancy, while 20 biopsy diagnoses were proved to be true-negative. There were 57 false-negative diagnoses and no false-positive diagnoses. The diagnostic performance of transluminal forceps biopsy in malignant biliary obstructions was as follows: sensitivity, 77.2%; specificity, 100%; and accuracy, 78.9%; positive predictive value, 100%, negative predictive value; 25.9%. Periampullary segment of common bile duct, intrahepatic bile duct and metastatic disease were the significant risk factors of false-negative diagnosis. CONCLUSIONS: Percutaneous forceps biopsy provides relatively high accuracy in the diagnosis of malignant biliary obstructions. The predictive factors of false-negative biopsy were determined to be biopsy site and origin of primary tumour. KEY POINTS: • Percutaneous forceps biopsy provides relatively high accuracy in diagnosis of malignant biliary obstructions. • The predictive factors of false-negative biopsy were biopsy site and origin of primary tumour. • The procedure-related complications were low.


Assuntos
Neoplasias dos Ductos Biliares/diagnóstico , Biópsia/métodos , Colangiocarcinoma/diagnóstico , Colestase Intra-Hepática/diagnóstico , Instrumentos Cirúrgicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/complicações , Ductos Biliares Intra-Hepáticos/patologia , Colangiocarcinoma/complicações , Ducto Colédoco/patologia , Reações Falso-Negativas , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade
2.
Korean J Intern Med ; 21(3): 187-90, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17017669

RESUMO

Vascular catheters are associated with complications such as infection, thrombosis and stenosis. The embolization of a venous catheter fragment is a rare complication. A 39-year-old woman underwent placement of a totally implantable venous access device for chemotherapy to treat a recurrent liposarcoma of the left thigh. The "pinch-off sign" was noted on a routine chest X-ray but that was ignored. Three-months after implantation of the intravenous access device, the indwelling central catheter was fractured and embolized to the pulmonary trunk. The catheter in the pulmonary trunk was successfully removed through a percutaneous femoral vein approach using a pigtail catheter and goose neck snare.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Embolia/etiologia , Falha de Equipamento , Migração de Corpo Estranho/complicações , Artéria Pulmonar/lesões , Adulto , Cateterismo Venoso Central/instrumentação , Embolia/cirurgia , Feminino , Migração de Corpo Estranho/cirurgia , Humanos , Lipossarcoma/tratamento farmacológico , Artéria Pulmonar/cirurgia , Coxa da Perna/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA