Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Med ; 24(8): 722-7, 1983 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6348219

RESUMO

When technetium-99m DTPA is used to measure glomerular filtration rate (GFR), the accuracy depends on the supplier of the radiopharmaceutical. The error in GFR is due to protein binding, as we have shown by direct measurement. In 19 patients, GFR measured with Tc-DTPA and corrected for protein binding agreed with that measured simultaneously using Yb-169 DTPA (correlation coefficient 0.991). Without correction, Tc-DTPA gave falsely low values in patients having good renal function, in whom unbound activity cleared rapidly while bound activity remained in the circulation. When Tc-DTPA is used to measure GFR, the in vivo protein binding should be measured and used to correct the data.


Assuntos
Taxa de Filtração Glomerular , Ácido Pentético/normas , Tecnécio/normas , Animais , Humanos , Masculino , Matemática , Camundongos , Ligação Proteica , Controle de Qualidade , Radioisótopos , Pentetato de Tecnécio Tc 99m , Itérbio
2.
J Nucl Med ; 26(11): 1243-7, 1985 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3903074

RESUMO

Glomerular filtration rate (GFR) can be calculated from the plasma clearance of any of several radiopharmaceuticals that are excreted by glomerular filtration. Simplified methods have been proposed that require only one or two plasma samples in lieu of a more complete clearance curve. We examined the error introduced by this simplification. Forty patients were studied using a dual-isotope technique employing [99mTc]DTPA and [169Yb]DTPA, obtaining eight plasma samples for each clearance curve at intervals from 10 to 240 min after injection. Data were fit to several empirical or semiempirical formulae and also to a two-compartment computer model that permitted GFR estimation from only one or two data points. The computer model gave good fit, but so did several simpler methods. The error that results from replacing the complete clearance curve by a single 3-hr sample was about 8 ml/min (residual s.d.). By using two samples (at 1 and 3 hr), the error could be reduced to 4 ml/min. Recommended one- and two-sample methods are presented.


Assuntos
Taxa de Filtração Glomerular , Ácido Pentético/metabolismo , Radioisótopos/metabolismo , Tecnécio/metabolismo , Itérbio/metabolismo , Humanos , Taxa de Depuração Metabólica , Plasma/fisiologia , Pentetato de Tecnécio Tc 99m , Urina/metabolismo
3.
Eur J Nucl Med ; 5(2): 103-8, 1980 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7379811

RESUMO

Details of a series of computer programs associated with a complex renal function procedure, all linked together into a single "macrofunction" are presented. Input consisted of not only in vivo nuclear medicine information, but also data concerning patient identification, urine volumes, voiding time, urine specific gravity, blood pressure and other pertinent information. Computer output consisted of images, curves and typed information presented in an integrated format ready for inclusion into the patient's record. Clinical evaluation of this comprehensive renal function macrofunction has proved to be useful, econominal, rapid and accurate. It has conveniently sorted a wide variety of disease states and provided clinical information not available from any other non-invasive technique.


Assuntos
Computadores , Testes de Função Renal/instrumentação , Adulto , Humanos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Nefropatias/fisiopatologia , Cinética , Masculino , Cintilografia , Fluxo Sanguíneo Regional , Fatores de Tempo , Micção
4.
Eur J Nucl Med ; 10(11-12): 519-21, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-3896814

RESUMO

A variety of methods have been proposed to estimate the glomerular filtration rate (GFR) from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare alternative methods, we calculated the GFR in several different ways from measurements in 33 patients and compared the results with an independent GFR measurement based on eight-point plasma clearance of ytterbium Yb 169-DTPA. The best agreement was obtained using an algorithm that has not been described previously, in which correction was made for overlap of the kidneys by the liver and spleen. The correlation coefficient was 0.958, and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with a correlation coefficient of 0.837 and a residual standard deviation of 23.1 ml/min. The accuracy of these methods was comparable to that reported for creatinine clearance, the most commonly used estimate of the GFR in current clinical practice.


Assuntos
Taxa de Filtração Glomerular , Rim/diagnóstico por imagem , Ácido Pentético , Tecnécio , Humanos , Radioisótopos , Cintilografia , Software , Pentetato de Tecnécio Tc 99m , Itérbio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA