1.
Circulation ; 149(7): 529-541, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-37950907

RESUMO

BACKGROUND: Hypertensive pregnancy disorders are associated with adverse cardiac remodeling, which can fail to reverse in the postpartum period in some women. The Physician-Optimized Postpartum Hypertension Treatment trial demonstrated that improved blood pressure control while the cardiovascular system recovers postpartum associates with persistently reduced blood pressure. We now report the effect on cardiac remodeling. METHODS: In this prospective, randomized, open-label, blinded end point trial, in a single UK hospital, 220 women were randomly assigned 1:1 to self-monitoring with research physician-optimized antihypertensive titration or usual postnatal care from a primary care physician and midwife. Participants were 18 years of age or older, with preeclampsia or gestational hypertension, requiring antihypertensives on hospital discharge postnatally. Prespecified secondary cardiac imaging outcomes were recorded by echocardiography around delivery, and again at blood pressure primary outcome assessment, around 9 months postpartum, when cardiovascular magnetic resonance was also performed. RESULTS: A total of 187 women (101 intervention; 86 usual care) underwent echocardiography at baseline and follow-up, at a mean 258±14.6 days postpartum, of which 174 (93 intervention; 81 usual care) also had cardiovascular magnetic resonance at follow-up. Relative wall thickness by echocardiography was 0.06 (95% CI, 0.07-0.05; P<0.001) lower in the intervention group between baseline and follow-up, and cardiovascular magnetic resonance at follow-up demonstrated a lower left ventricular mass (-6.37 g/m2; 95% CI, -7.99 to -4.74; P<0.001), end-diastolic volume (-3.87 mL/m2; 95% CI, -6.77 to -0.98; P=0.009), and end-systolic volume (-3.25 mL/m2; 95% CI, 4.87 to -1.63; P<0.001) and higher left and right ventricular ejection fraction by 2.6% (95% CI, 1.3-3.9; P<0.001) and 2.8% (95% CI, 1.4-4.1; P<0.001), respectively. Echocardiography-assessed left ventricular diastolic function demonstrated a mean difference in average E/E' of 0.52 (95% CI, -0.97 to -0.07; P=0.024) and a reduction in left atrial volumes of -4.33 mL/m2 (95% CI, -5.52 to -3.21; P<0.001) between baseline and follow-up when adjusted for baseline differences in measures. CONCLUSIONS: Short-term postnatal optimization of blood pressure control after hypertensive pregnancy, through self-monitoring and physician-guided antihypertensive titration, associates with long-term changes in cardiovascular structure and function, in a pattern associated with more favorable cardiovascular outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04273854.


Assuntos
Anti-Hipertensivos , Hipertensão Induzida pela Gravidez , Adolescente , Adulto , Feminino , Humanos , Gravidez , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea , Ecocardiografia , Hipertensão Induzida pela Gravidez/tratamento farmacológico , Estudos Prospectivos , Volume Sistólico , Função Ventricular Direita , Remodelação Ventricular
2.
Am Heart J ; 263: 123-132, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37192698

RESUMO

BACKGROUND: Stress echocardiography (SE) is one of the most commonly used diagnostic imaging tests for coronary artery disease (CAD) but requires clinicians to visually assess scans to identify patients who may benefit from invasive investigation and treatment. EchoGo Pro provides an automated interpretation of SE based on artificial intelligence (AI) image analysis. In reader studies, use of EchoGo Pro when making clinical decisions improves diagnostic accuracy and confidence. Prospective evaluation in real world practice is now important to understand the impact of EchoGo Pro on the patient pathway and outcome. METHODS: PROTEUS is a randomized, multicenter, 2-armed, noninferiority study aiming to recruit 2,500 participants from National Health Service (NHS) hospitals in the UK referred to SE clinics for investigation of suspected CAD. All participants will undergo a stress echocardiogram protocol as per local hospital policy. Participants will be randomized 1:1 to a control group, representing current practice, or an intervention group, in which clinicians will receive an AI image analysis report (EchoGo Pro, Ultromics Ltd, Oxford, UK) to use during image interpretation, indicating the likelihood of severe CAD. The primary outcome will be appropriateness of clinician decision to refer for coronary angiography. Secondary outcomes will assess other health impacts including appropriate use of other clinical management approaches, impact on variability in decision making, patient and clinician qualitative experience and a health economic analysis. DISCUSSION: This will be the first study to assess the impact of introducing an AI medical diagnostic aid into the standard care pathway of patients with suspected CAD being investigated with SE. TRIAL REGISTRATION: Clinicaltrials.gov registration number NCT05028179, registered on 31 August 2021; ISRCTN: ISRCTN15113915; IRAS ref: 293515; REC ref: 21/NW/0199.


Assuntos
Doença da Artéria Coronariana , Ecocardiografia sob Estresse , Humanos , Inteligência Artificial , Medicina Estatal , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos
3.
Echo Res Pract ; 10(1): 8, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37254216

RESUMO

BACKGROUND: Stress echocardiography is widely used to detect coronary artery disease, but little evidence on downstream hospital costs in real-world practice is available. We examined how stress echocardiography accuracy and downstream hospital costs vary across NHS hospitals and identified key factors that affect costs to help inform future clinical planning and guidelines. METHODS: Data on 7636 patients recruited from 31 NHS hospitals within the UK between 2014 and 2020 as part of EVAREST/BSE-NSTEP clinical study, were used. Data included all diagnostic tests, procedures, and hospital admissions for 12 months after a stress echocardiogram and were costed using the NHS national unit costs. A decision tree was built to illustrate the clinical pathway and estimate average downstream hospital costs. Multi-level regression analysis was performed to identify variation in accuracy and costs at both patient, procedural, and hospital level. Linear regression and extrapolation were used to estimate annual hospital cost-savings associated with increasing predictive accuracy at hospital and national level. RESULTS: Stress echocardiography accuracy varied with patient, hospital and operator characteristics. Hypertension, presence of wall motion abnormalities and higher number of hospital cardiology outpatient attendances annually reduced accuracy, adjusted odds ratio of 0.78 (95% CI 0.65 to 0.93), 0.27 (95% CI 0.15 to 0.48), 0.99 (95% CI 0.98 to 0.99) respectively, whereas a prior myocardial infarction, angiotensin receptor blocker medication, and greater operator experience increased accuracy, adjusted odds ratio of 1.77 (95% CI 1.34 to 2.33), 1.64 (95% CI 1.22 to 2.22), and 1.06 (95% CI 1.02 to 1.09) respectively. Average downstream costs were £646 per patient (SD 1796) with significant variation across hospitals. The average downstream costs between the 31 hospitals varied from £384-1730 per patient. False positive and false negative tests were associated with average downstream costs of £1446 (SD £601) and £4192 (SD 3332) respectively, driven by increased non-elective hospital admissions, adjusted odds ratio 2.48 (95% CI 1.08 to 5.66), 21.06 (95% CI 10.41 to 42.59) respectively. We estimated that an increase in accuracy by 1 percentage point could save the NHS in the UK £3.2 million annually. CONCLUSION: This study provides real-world evidence of downstream costs associated with stress echocardiography practice in the UK and estimates how improvements in accuracy could impact healthcare expenditure in the NHS. A real-world downstream costing approach could be adopted more widely in evaluation of imaging tests and interventions to reflect actual value for money and support realistic planning.

SELEÇÃO DE REFERÊNCIAS