Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Radiology ; 279(1): 167-74, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26473641

RESUMO

PURPOSE: To evaluate the effect of automated tube voltage selection (ATVS) on radiation dose at computed tomography (CT) worldwide encompassing all body regions and types of CT examinations. MATERIALS AND METHODS: No patient information was accessed; therefore, institutional review board approval was not sought. Data from 86 centers across the world were analyzed. All CT interactions were automatically collected and transmitted to the CT vendor during two 6-week periods immediately before and 2 weeks after implementation of ATVS. A total of 164 323 unique CT studies were analyzed. Studies were categorized by body region and type of examination. Tube voltage and volume CT dose index (CTDIvol) were compared between examinations performed with ATVS and those performed before ATVS implementation. Descriptive statistical methods and multilevel linear regression models were used for analysis. RESULTS: Across all types of CT examinations and body regions, CTDIvol was 14.7% lower in examinations performed with ATVS (n = 30 313) than in those performed before ATVS implementation (n = 79 275). Relative reductions in mean CTDIvol were most notable for temporal bone CT (-56.1%), peripheral runoff CT angiography (-48.6%), CT of the paranasal sinus (-39.6%), cerebral or carotid CT angiography (-36.4%), coronary CT angiography (-25.1%), and head CT (-23.9%). An increase in mean CTDIvol was observed for renal stone protocols (26.2%) and thoracic or lumbar spine examinations (6.6%). In the multilevel model with fixed effects ATVS and examination type, and the interaction of these variables and the random effect country, a significant influence on CTDIvol for all fixed efects was revealed (ATVS, P = .0031; examination type, P < .0001; interaction term, P < .0001). CONCLUSION: ATVS significantly reduces radiation dose across most, but not all, body regions and types of CT examinations.


Assuntos
Algoritmos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Automação , Humanos , Estudos Retrospectivos
2.
Eur Radiol ; 26(9): 3215-22, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26650935

RESUMO

OBJECTIVES: To assess quantitatively the impact of a novel reconstruction algorithm ("kernel") with beam-hardening correction (BHC) on beam-hardening artefacts of the myocardium at dual-energy CT myocardial perfusion imaging (DE-CTMPI). METHODS: Rest-series of DE-CTMPI examinations from 14 patients were retrospectively analyzed. Six image series were reconstructed for each patient: a) 100 kV, b) 140 kV, and c) linearly blended MIX0.5, each with BHC (D33f kernel) and without (D30f kernel). Seven hundred and fifty-six myocardial regions were assessed. Seven equal regions of interest divided the myocardium in the axial section. Three subdivisions were created within these regions in areas prone to BHA. Reports of SPECT studies performed within 30 days of CT examination were used to confirm the presence and location of true perfusion defects. Paired student t-test was used for statistical evaluation. RESULTS: Overall mean myocardial attenuation was lower using BHC (D30f: 87.3 ± 24.1 HU; D33f: 85.5 ± 21.5 HU; p = 0.009). Overall relative difference from average myocardial attenuation (RDMA) was more homogeneous using BHC (D30f: -0.3 ± 11.4 %; D33f: 0.1 ± 10.1 %; p < 0.001). Changes in RDMA were greatest in the posterobasal myocardium (D30f: -16.2 ± 10.0 %; D33f: 3.4 ± 10.7 %; p < 0.001). CONCLUSIONS: A dedicated reconstruction algorithm with BHC can significantly reduce beam-hardening artefacts in DE-CTMPI. KEY POINTS: • Beam-hardening artefacts (BHA) cause interference with attenuation-based CT myocardial perfusion assessment (CTMPI). • BHA occur mostly in the posterobasal left ventricular wall. • Beam-hardening correction homogenized and decreased mean myocardial attenuation. • BHC can help avoid false-positive findings and increase specificity of static CTMPI.


Assuntos
Coração/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
3.
Radiology ; 276(3): 706-14, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25786157

RESUMO

PURPOSE: To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. MATERIALS AND METHODS: By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. RESULTS: Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). CONCLUSION: The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.


Assuntos
Vasos Coronários , Processamento de Imagem Assistida por Computador , Stents , Tomografia Computadorizada por Raios X , Algoritmos , Imagens de Fantasmas , Desenho de Prótese
4.
Radiology ; 275(1): 80-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25393848

RESUMO

PURPOSE: To assess the accuracy of computed tomographic (CT) examinations performed for the purpose of transcatheter aortic valve replacement (TAVR) planning to diagnose obstructive coronary artery disease (CAD). MATERIALS AND METHODS: With institutional review board approval, waivers of informed consent, and in compliance with HIPAA, 100 consecutive TAVR candidates (61 men, mean age 79.6 years ± 9.9) who underwent both TAVR planning CT (with a dual-source CT system) and coronary catheter (CC) angiographic imaging were retrospectively analyzed. At both modalities, the presence of stenosis in the native coronary arteries was assessed. Additionally, all coronary bypass grafts were rated as patent or occluded. With CC angiographic imaging as the reference standard, the accuracy of CT for lesion detection on a per-vessel and per-patient basis was calculated. The accuracy of CT for the assessment of graft patency was also analyzed. RESULTS: For per-vessel and per-patient analysis for the detection of stenosis that was 50% or more in the native coronary arteries, CT imaging had, respectively, 94.4% and 98.6% sensitivity, 68.4% and 55.6% specificity, 94.7% and 93.8% negative predictive value (NPV), and 67.0% and 85.7% positive predictive value. Per-patient sensitivity of stenosis 50% or greater with CT for greater than 70% stenosis at CC angiographic imaging was 100%. All 12 vessels in which percutaneous coronary intervention was performed were correctly identified as demonstrating stenosis 50% or greater with CT. There was agreement between CT and CC angiographic imaging regarding graft patency in 114 of 115 grafts identified with CC angiographic imaging. CONCLUSION: TAVR planning CT has high sensitivity and NPV in excluding obstructive CAD. An additional preprocedural CC angiographic examination may not be required in TAVR candidates with a CT examination that does not show obstructive CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Planejamento de Assistência ao Paciente , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Fatores de Risco , Ácidos Tri-Iodobenzoicos , Grau de Desobstrução Vascular
5.
Eur Radiol ; 25(11): 3372-81, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25925354

RESUMO

OBJECTIVES: To perform a systematic review of the growing body of literature evaluating the prognostic value of epicardial fat volume (EFV) quantified by cross-sectional imaging. METHODS: Two independent reviewers performed systematic searches on both PubMed and Scopus using search terms developed with a medical librarian. Peer-reviewed articles were selected based on the inclusion of outcome data, utilization of epicardial fat volume and sufficient reporting for analysis. RESULTS: A total of 411 studies were evaluated with nine studies meeting the inclusion criteria. In all, the studies evaluated 10,252 patients. All nine studies were based on CT measurements. Seven studies evaluated the prognostic value of EFV unadjusted for calcium score, and six of these studies found a significant association between EFV and clinical outcomes. Seven studies evaluated the incremental value of EFV beyond calcium scoring, and six of these studies found a significant association. CONCLUSIONS: The majority of studies suggest that EFV quantification is significantly associated with clinical outcomes and provides incremental prognostic value over coronary artery calcium scoring. Future research should use a binary cutoff of 125 mL for evaluation of EFV to provide consistency with other research. KEY POINTS: • Epicardial fat volume (EFV) has prognostic value for adverse cardiac events • Establishment of standardized quantitative categories for EFV is needed • Quantification of EFV could improve risk assessment with calcium scoring.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Eur Radiol ; 24(11): 2677-84, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25052076

RESUMO

OBJECTIVES: To evaluate the effect of automated tube voltage selection on radiation dose and image quality at cardiovascular CT angiography (CTA). METHODS: We retrospectively analysed paired studies in 72 patients (41 male, 60.5 ± 16.5 years), who had undergone CTA acquisitions of the heart or aorta both before and after the implementation of an automated x-ray tube voltage selection algorithm (ATVS). All other parameters were kept identical between the two acquisitions. Subjective image quality (IQ) was rated and objective IQ was measured by image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and figure of merit (FOM). Image quality parameters and effective dose were compared between acquisitions. RESULTS: Overall subjective image quality improved with the percentage of cases scored as adequate or higher increasing from 79 % to 92 % after implementation of ATVS (P = 0.03). SNR (14.1 ± 5.9, 15.7 ± 6.1, P = 0.009), CNR (11.6 ± 5.3, 13.2 ± 5.6, P = 0.011), and FOM (19.9 ± 23.3, 43.8 ± 51.1, P < 0.001) were significantly higher after implementation of ATVS. Mean image noise (24.1 ± 8.4 HU, 22.7 ± 7.1 HU, P = 0.048) and mean effective dose (10.6 ± 5.9 mSv, 8.8 ± 5.0 mSv, P = 0.003) were significantly lower after implementation of ATVS. CONCLUSIONS: Automated tube voltage selection can operator-independently optimize cardiovascular CTA image acquisition parameters with improved image quality at reduced dose. KEY POINTS: • Automatic tube voltage selection optimizes tube voltage for each individual patient. • In this population, overall radiation dose decreased while image quality improved. • This tool may become valuable for improving dose/quality ratio.


Assuntos
Algoritmos , Angiografia/métodos , Aumento da Imagem/métodos , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Eur Radiol ; 24(2): 519-26, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24192980

RESUMO

OBJECTIVES: This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). METHODS: cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. RESULTS: The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). CONCLUSIONS: Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. KEY POINTS: • Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. • The novel software prototype automates measurement of epicardial fat volume with good accuracy. • This novel approach is less time-consuming and could be incorporated into clinical workflow.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de Software
8.
AJR Am J Roentgenol ; 203(1): W70-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24951230

RESUMO

OBJECTIVE: The purpose of this article is to prospectively determine the value of stress dual-energy CT (DECT) myocardial perfusion imaging to coronary CT angiography (CTA) for the assessment of coronary artery disease (CAD) in a high-risk population. SUBJECTS AND METHODS: We prospectively enrolled 29 consecutive patients who were referred for cardiac SPECT examinations for known or suspected CAD to also undergo pharmacologic stress cardiac DECT. In 25 patients, cardiac catheterization was available as the reference standard for morphologically significant stenosis. The performance of coronary CTA alone, DECT myocardial perfusion alone, and the combination of both was assessed by calculating sensitivity, specificity, and AUC values. RESULTS: For morphologically significant stenosis, coronary CTA alone and myocardial DECT assessment alone had 95% sensitivity and 50% specificity. The combined approach yielded 100% sensitivity and 33% specificity if either was positive and 90% sensitivity and 67% specificity if both were positive. The AUC value was highest (0.78) if both were positive. For hemodynamically significant lesions, coronary CTA alone had 91% sensitivity and 38% specificity, and DECT alone had 95% sensitivity and 75% specificity. The combined approach yielded 100% sensitivity and 38% specificity if either was positive and 86% sensitivity and 75% specificity if both were positive. AUC values were highest for DECT alone (0.85) and the "both positive" evaluation (0.80). CONCLUSION: The combined analysis of coronary CTA and DECT myocardial perfusion reduces the number of false-positives in a high-risk population for CAD and outperforms the purely anatomic test of coronary CTA alone for the detection of morphologically and hemodynamically significant CAD.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Adenosina , Cateterismo Cardíaco , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Purinas/administração & dosagem , Pirazóis/administração & dosagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
9.
AJR Am J Roentgenol ; 203(2): W174-80, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24848691

RESUMO

OBJECTIVE: The purpose of this study was to determine the feasibility of global quantitative measurements of left ventricular myocardial perfusion derived from stress dynamic CT myocardial perfusion imaging. MATERIALS AND METHODS: The coronary CT angiographic and CT myocardial perfusion imaging datasets of 146 patients were visually evaluated for the presence of coronary artery stenosis and perfusion defects. For the quantitative analysis, volumes of interest were defined over the entire left ventricular myocardium to obtain global myocardial blood flow (MBF), myocardial blood volume (MBV), and volume transfer constant (K(trans)). RESULTS: In patients without anatomically significant coronary stenosis or perfusion defects, the mean value of global MBF was 137.9 ± 28.8 mL/100 mL/min; MBV, 19.5 ± 2.3 mL/100 mL; and K(trans), 85.8 ± 15.2 mL/100 mL/min. In patients with perfusion defects in one, two, or three vessels, the mean global MBF values were 132.6 ± 29.2, 117.4 ± 4.9, and 92.5 ± 11.2 mL/100 mL/min; MBV, 17.9 ± 3.2, 16.1 ± 3.1, and 12.8 ± 1.7 mL/100 mL; and K(trans), 80.4 ± 12.9, 76.6 ± 13.8, and 72.6 ± 15.5 mL/100 mL/min. In patients with significant (> 50%) stenosis in one, two, or three vessels at coronary CT angiography, the mean global MBF values were 129.2 ± 28.3, 120.5 ± 24.2, and 119.4 ± 33.5 mL/100 mL/min; MBV, 17.8 ± 3.3, 17.2 ± 3.2, and 14.7 ± 4.1 mL/100 mL; and K(trans), 80.3 ± 12.9, 76.0 ± 14.7, and 77.6 ± 13.2 mL/100 mL/min. CONCLUSION: Global quantitative assessment of left ventricular perfusion with stress dynamic CT myocardial perfusion imaging is feasible, and the findings correlate with the visual assessment of perfusion and the presence of coronary artery stenosis at coronary CT angiography. The potential clinical utility of this technique as a diagnostic tool for differentiating normal from globally reduced myocardial perfusion or as a prognostic marker merits further investigation.


Assuntos
Estenose Coronária/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Angiografia Coronária , Circulação Coronária , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos
10.
Semin Respir Crit Care Med ; 35(1): 50-63, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24481759

RESUMO

The respiratory and the cardiovascular systems are intimately connected. Because of the high degree of morphological and functional interaction, pathophysiological processes in one compartment are likely to induce adaptive changes in the other. Computed tomography (CT) plays a central role in the diagnostic work up of both thoracic and cardiac disorders. Historically, these two systems have been evaluated separately; however, CT technology has evolved remarkably over recent decades. Up-to-date advanced imaging strategies allow for a combined assessment of the cardiopulmonary unit. Besides improved techniques of electrocardiogram (ECG)-synchronization for obtaining both morphological and functional information, latest advances of dual-source CT (DSCT) have shown great promise for even more comprehensive integrated cardiothoracic imaging.


Assuntos
Doenças Cardiovasculares/diagnóstico , Doenças Torácicas/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Doenças Cardiovasculares/fisiopatologia , Eletrocardiografia/métodos , Humanos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Doenças Torácicas/fisiopatologia , Tomografia Computadorizada por Raios X/tendências
11.
Eur Radiol ; 23(10): 2666-75, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23760304

RESUMO

OBJECTIVES: To evaluate the feasibility and findings of combined dual-energy computed tomography (DECT) lung ventilation/perfusion imaging in patients with suspected pulmonary embolism (PE). METHODS: This study was institutional review board-approved and written informed consent was obtained from each patient. Thirty-two subjects (aged 11-61 years) underwent combined xenon-enhanced ventilation and iodine-enhanced perfusion DECT. Ventilation, perfusion and morphological information were visually interpreted. Ventilation/perfusion information was classified as mismatch (differing patterns) or match (concordant patterns). Adverse reactions and radiation doses were recorded for each subject. RESULTS: Of 32 patients undergoing xenon-enhanced DECT, six patients reported adverse reactions (shortness of breath, n = 2; mild dizziness, n = 3; limb numbness, n = 1). Twenty-eight of 32 patients could be included into the data analysis. PE was detected in 10/28 patients. PE-related ventilation/perfusion mismatch was found in 17 lung lobes in 8/10 patients and matched ventilation/perfusion was detected in 2 patients. Eighteen patients had no PE. In this group, there was no case of a ventilation/perfusion mismatch. Matched ventilation/perfusion impairment was seen in one patient. The overall radiation dose from two DECT acquisitions was 4.8 ± 1.4 mSv (range 2.7-7.5 mSv). CONCLUSIONS: DECT lung ventilation/perfusion imaging is feasible and can visualise ventilation/perfusion match or mismatch in patients with suspected PE. KEY POINTS: • Combined dual-energy CT lung ventilation/perfusion imaging is feasible. • Combined dual-energy CT ventilation/perfusion imaging provides lung morphological and functional information. • Dual-energy CT can demonstrate ventilation/perfusion mismatch in patients with pulmonary embolism.


Assuntos
Algoritmos , Imagem de Perfusão/métodos , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Relação Ventilação-Perfusão , Adolescente , Adulto , Criança , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
Eur Radiol ; 23(3): 650-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22983281

RESUMO

OBJECTIVES: Performance evaluation of a fully automated system for calculating computed tomography (CT) coronary artery calcium scores from contrast medium-enhanced coronary CT angiography (cCTA) studies. METHODS: One hundred and twenty-seven patients (58 ± 11 years, 71 men) who had undergone cCTA as well as an unenhanced CT calcium scoring study where included. Calcium scores were computed from cCTA by an automated image processing algorithm and compared with calcium scores obtained by standard manual assessment of unenhanced CT calcium scoring studies. Results were compared vis-a-vis (1) absolute calcium score values, (2) age-, gender- and race-dependent percentiles, and (3) commonly used calcium score risk classification categories. RESULTS: One hundred and nineteen out of 127 (93.7%) studies were successfully processed. Mean Agatston calcium score values obtained by traditional non-contrast CT calcium scoring studies and derived from contrast medium-enhanced cCTA did not significantly differ (235.6 ± 430.5 vs 262.0 ± 499.5; P > 0.05). Calcium score risk categories and Multi-Ethnic Study of Atherosclerosis (MESA) percentiles showed very high correlation (Spearman rank correlation coefficient = 0.97, P < 0.0001/0.95, P < 0.0001) between the two approaches. CONCLUSIONS: Calcium score values automatically computed from cCTA are highly correlated with standard unenhanced CT calcium scoring studies. These results suggest a radiation dose- and time-saving potential when deriving calcium scores from cCTA studies without a preceding unenhanced CT calcium scoring study.


Assuntos
Algoritmos , Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iohexol/análogos & derivados , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Calcinose/complicações , Meios de Contraste , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
13.
Sci Rep ; 8(1): 9228, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29907855

RESUMO

We aimed to determine the diagnostic yield and accuracy of coronary CT angiography (CCTA) in patients referred for invasive coronary angiography (ICA) based on clinical concern for coronary artery disease (CAD) and an abnormal nuclear stress myocardial perfusion imaging (MPI) study. We enrolled 100 patients (84 male, mean age 59.6 ± 8.9 years) with an abnormal MPI study and subsequent referral for ICA. Each patient underwent CCTA prior to ICA. We analyzed the prevalence of potentially obstructive CAD (≥50% stenosis) on CCTA and calculated the diagnostic accuracy of ≥50% stenosis on CCTA for the detection of clinically significant CAD on ICA (defined as any ≥70% stenosis or ≥50% left main stenosis). On CCTA, 54 patients had at least one ≥50% stenosis. With ICA, 45 patients demonstrated clinically significant CAD. A positive CCTA had 100% sensitivity and 84% specificity with a 100% negative predictive value and 83% positive predictive value for clinically significant CAD on a per patient basis in MPI positive symptomatic patients. In conclusion, almost half (48%) of patients with suspected CAD and an abnormal MPI study demonstrate no obstructive CAD on CCTA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
14.
Acad Radiol ; 22(9): 1138-46, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26094116

RESUMO

RATIONALE AND OBJECTIVES: To investigate the diagnostic performance of a comprehensive computed tomography (CT) protocol for both cardiac and aortoiliac evaluation of patients considered for transcatheter aortic valve replacement (TAVR) using a single, low-volume contrast medium (CM) injection. MATERIALS AND METHODS: Forty-four TAVR candidates were retrospectively analyzed. All underwent retrospectively electrocardiogram-gated cardiac CT followed by high-pitch CT angiography of the aortoiliac vasculature using one of two single injection protocols of 320 mgI/mL iodine CM: group A (n = 22), iodine delivery rate-based (1.28 gI/s), 60-mL CM volume, 4.0 mL/s flow rate; group B (n = 22), clinical routine protocol, 100-mL CM volume, 4.0 mL/s flow rate. Mean arterial attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was assessed. RESULTS: Aortic root and iliofemoral dimensions could be analyzed in all cases. Patient characteristics showed no significant differences. Mean attenuation at the levels of the aortic root (285.8 ± 83.0 HU vs 327.5 ± 70.8 HU, P = .080) and the iliofemoral access route (256.8 ± 88.5 HU vs 307.5 ± 93.2 HU, P = .071), as well as SNR and CNR were nonsignificantly lower in group A compared to group B. Subjective image quality was equivalent. CONCLUSIONS: In multimorbid TAVR patients, the performance of a combined CT protocol using a single low-volume CM bolus is feasible with maintained image quality compared to a standard protocol.


Assuntos
Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Coração/diagnóstico por imagem , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Planejamento de Assistência ao Paciente , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Ácidos Tri-Iodobenzoicos/administração & dosagem
15.
Eur J Radiol ; 84(6): 1062-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25843418

RESUMO

OBJECTIVES: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. METHODS: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. RESULTS: Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. CONCLUSIONS: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements.


Assuntos
Tecido Adiposo/patologia , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Pericárdio/patologia , Tomografia Computadorizada por Raios X , Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Sístole , Tomografia Computadorizada por Raios X/métodos
16.
J Thorac Imaging ; 29(4): 198-208, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24662334

RESUMO

Iterative image reconstruction algorithms provide significant improvements over traditional filtered back projection in computed tomography (CT). Clinically available through recent advances in modern CT technology, iterative reconstruction enhances image quality through cyclical image calculation, suppressing image noise and artifacts, particularly blooming artifacts. The advantages of iterative reconstruction are apparent in traditionally challenging cases-for example, in obese patients, those with significant artery calcification, or those with coronary artery stents. In addition, as clinical use of CT has grown, so have concerns over ionizing radiation associated with CT examinations. Through noise reduction, iterative reconstruction has been shown to permit radiation dose reduction while preserving diagnostic image quality. This approach is becoming increasingly attractive as the routine use of CT for pediatric and repeated follow-up evaluation grows ever more common. Cardiovascular CT in particular, with its focus on detailed structural and functional analyses, stands to benefit greatly from the promising iterative solutions that are readily available.


Assuntos
Algoritmos , Angiografia Coronária/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Comorbidade , Vasos Coronários/diagnóstico por imagem , Humanos , Obesidade/epidemiologia , Doses de Radiação
17.
Biomed Res Int ; 2014: 931413, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24800254

RESUMO

The exact pathophysiology of contrast-induced nephropathy (CIN) is not fully clarified, yet the osmotic characteristics of contrast media (CM) have been a significant focus in many investigations of CIN. Osmotic effects of CM specific to the kidney include transient decreases in blood flow, filtration fraction, and glomerular filtration rate. Potentially significant secondary effects include an osmotically induced diuresis with a concomitant dehydrating effect. Clinical experiences that have compared the occurrence of CIN between the various classes of CM based on osmolality have suggested a much less than anticipated advantage, if any, with a lower osmolality. Recent animal experiments actually suggest that induction of a mild osmotic diuresis in association with iso-osmolar agents tends to offset potentially deleterious renal effects of high viscosity-mediated intratubular CM stagnation.


Assuntos
Meios de Contraste/efeitos adversos , Meios de Contraste/química , Nefropatias/induzido quimicamente , Animais , Humanos , Concentração Osmolar , Ratos
18.
Acad Radiol ; 21(7): 938-44, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24928163

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the performance of radiology residents in the interpretation of on-call, emergency "triple-rule-out" (TRO) computed tomographic (CT) studies in patients with acute chest pain. MATERIALS AND METHODS: The study was institutional review board-approved and Health Insurance Portability and Accountability Act compliant. Data from 617 on-call TRO studies were analyzed. Dedicated software enables subspecialty attendings to grade discrepancies in interpretation between preliminary trainee reports and their final interpretation as "unlikely to be significant" (minor discrepancies) or "likely to be significant" for patient management (major discrepancies). The frequency of minor, major and all discrepancies in resident's TRO interpretations was compared to 609 emergent non-electrocardiography (ECG)-synchronized chest CT studies using Pearson χ(2) test. RESULTS: Minor discrepancies occurred more often in the TRO group (9.1% vs. 3.9%, P < .001), but there was no difference in the frequency of major discrepancies (2.1% vs. 2.8%, P = .55). Minor discrepancies in the TRO group most commonly resulted from missed extrathoracic findings with missed liver lesions being the most frequent. Major discrepancies mostly encompassed cardiac and extracardiac vascular findings but did not result in unnecessary interventions, significant immediate changes in management, or adverse patient outcomes. CONCLUSIONS: On-call resident interpretation of TRO CT studies in patients with acute chest pain is congruent with final subspecialty attending interpretation in the overwhelming majority of cases. The rate of discrepancies likely to affect patient management in this domain is not different from emergent non-ECG-synchronized chest CT.


Assuntos
Plantão Médico/estatística & dados numéricos , Doenças da Aorta/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Competência Clínica/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Internato e Residência/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Doença Aguda , Diagnóstico Diferencial , Humanos , Variações Dependentes do Observador , Embolia Pulmonar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , South Carolina
19.
J Thorac Imaging ; 28(4): 231-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23736825

RESUMO

Transcatheter aortic valve replacement (TAVR) is rapidly becoming a widely used alternative to surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis at high surgical risk. In these patients, TAVR has been associated with markedly improved survival and relief from symptoms. Despite a very-high risk patient profile, recent multicenter registries have confirmed the safety and efficacy of this procedure. Moreover, the randomized, controlled PARTNER (Placement of AoRTic TraNscathetER Valves) trial has confirmed both the superiority of TAVR over medical treatment in patients not considered to be candidates for standard SAVR and the noninferiority of TAVR compared with SAVR in high-risk patients. The TAVR procedure requires a comprehensive preinterventional diagnostic workup. Above all, detailed information on the anatomy of the aortic annulus (AA) and the relation of the AA to the coronary arteries is essential to avoid complications. So far, no imaging reference standard for AA sizing has been established. Echocardiography, catheter angiography, and computed tomography angiography are widely and often complementarily used imaging techniques for this purpose. Compared with 2-dimensional imaging techniques, computed tomography (CT) has been proven to provide comprehensive information on AA anatomy and geometry, supporting appropriate patient selection and prosthesis sizing. In addition, CT is gaining an increasing role in evaluating the vascular access route before the procedure. This article describes the rapidly emerging role of CT in the context of pre-TAVR assessment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Implante de Prótese de Valva Cardíaca/métodos , Tomografia Computadorizada por Raios X/métodos , Cateterismo Cardíaco , Angiografia Coronária , Próteses Valvulares Cardíacas , Humanos , Tomografia Computadorizada Multidetectores , Seleção de Pacientes , Desenho de Prótese , Medição de Risco , Seio Aórtico/diagnóstico por imagem
20.
J Cardiovasc Comput Tomogr ; 7(6): 400-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24331936

RESUMO

Williams syndrome is a relatively common (1 in 10,000 live births) genetic disorder caused by a deletion involving chromosome 7 that results in a variety of clinically significant abnormalities, including developmental delay, behavioral changes, hypercalcemia, and a distinct "elfin" facial appearance. Congenital cardiovascular disease that presents in childhood is responsible for most of the morbidity and mortality associated with this disorder. The purpose of this pictorial essay is to review imaging findings of some of the more common cardiovascular manifestations of Williams syndrome and to highlight some of the unique anatomic variations that can be seen in these patients.


Assuntos
Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Síndrome de Williams/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA