Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Internist (Berl) ; 62(8): 871-875, 2021 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-34097078

RESUMO

A 39-year-old male patient presented with dyspnea and palpitations. The electrocardiogram (ECG) showed a first degree atrioventricular (AV) block and frequent atrial extra systoles. Within the following 48 h the AV block gradually developed into a third degree intermittent complete AV block. The patient history included an untreated tick bite 2 months before presentation. The serological proof of antibodies confirmed the diagnosis of Lyme carditis and antibiotic treatment with ceftriaxon i.v. was initiated. Normal AV conduction finally resumed and the symptoms subsided completely without any further clinical consequences.


Assuntos
Bloqueio Atrioventricular , Doença de Lyme , Miocardite , Adulto , Bloqueio Atrioventricular/diagnóstico , Ceftriaxona , Dispneia/diagnóstico , Dispneia/etiologia , Eletrocardiografia , Humanos , Doença de Lyme/complicações , Doença de Lyme/diagnóstico , Doença de Lyme/tratamento farmacológico , Masculino
2.
Pacing Clin Electrophysiol ; 38(1): 129-35, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25494851

RESUMO

BACKGROUND: We investigated whether the new second generation of cryoballoons can improve the efficiency and safety of cryoablation for atrial fibrillation (AF) during ablation and in terms of outcome. METHODS: Data of AF patients consecutively treated with a single 28-mm cryoballoon were analyzed. Patients were divided into two groups: the G1 group was treated with the first-generation cryoballoons (ArcticFront) and G2 with the second generation (ArcticFront Advance). Failure of cryoablation treatment was defined as detection of an episode of AF, atrial flutter, or atrial tachycardia lasting ≥ 30 seconds during 3-month follow-up. Left atrial diameter (LAD) was measured by transthoracic echocardiography before cryoablation. RESULTS: One hundred twenty-five patients (group G1/G2: 57/68) were enrolled. Mean total time of the whole procedure, cryomapping, and cryoablation was shorter with G2 than with G1 (P < 0.05). No complication occurred with G1 whereas with G2 the complication rate was 8.8%. During mean 12 ± 4 months follow-up, the overall success rate of cryoablation was 76.0% (95/125); it was higher with G2 (89.7% [61/68] vs 59.7% [34/57], P < 0.001). Patients in whom treatment failed had larger LAD (48 ± 8 mm vs 44 ± 6 mm, P = 0.002) than those in whom it succeeded. Type of cryoballoon (relative risk [RR] = 5.75 [2.16, 15.27], P < 0.0001) and LAD (RR = 0.90 [0.83, 0.97], P = 0.0043) were shown in multivariable analysis to be individually related to the difference in success rate. CONCLUSION: Ablation for AF with the new generation of cryoballoons is associated with higher success rate of pulmonary vein isolation and better outcome. However, more complications occurred during the early stage of application of the G2 cryoballoon.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 37(5): 603-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24883449

RESUMO

INTRODUCTION: Electrical reconnection of the pulmonary veins (PVs) plays a key role in the recurrence of atrial fibrillation (AF) after ablative treatment. This randomized controlled study tested the hypothesis that prolonged ablations, on areas that may be critical for left atrial (LA)-PV conduction, can significantly reduce the rate of acute PV reconnection and AF recurrence. METHODS: Patients with paroxysmal AF were randomly assigned to either a control or an add-on group.Ostial PV isolation (PVI) was performed by point-to-point RF ablation (irrigated tip, 30 Watts, 30 seconds).An ostial segment was assumed to be critical for LA-PV connection if any of the following reactions occurred during RF application: (1) sudden delay of LA-PV conduction, (2) change of activation sequence,and (3) PVI. In this case, RF application was prolonged from 30 seconds to 90 seconds in the add-on group only. RESULTS: A total of 131 patients (58 ± 11 years, 47 female) were assigned to a control (n = 64) and an add-on (n = 67) group. Ablation time was longer in the add-on (48 ± 16 minutes vs 37 ± 15 minutes, P = 0.03). Acute PV reconnection was observed in 20 of 64 controls and in eight of 66 add-on patients (31% vs 12%, P < 0.001). During a follow-up of 26 months, AF recurred in 33 of 64 controls and in 16 of 66 add-on patients (52% vs 24%, P = 0.001) after a single ablation procedure. CONCLUSIONS: Prolonged radiofrequency application on critical segments of LA-PV connection is a safe and effective ablative strategy that significantly reduces acute PV reconnection and AF recurrence rates after a single ablation procedure for paroxysmal AF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Duração da Cirurgia , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
4.
J Electrocardiol ; 47(5): 669-76, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24857184

RESUMO

INTRODUCTION: Detection of QRS complexes, P-waves and atrial fibrillation f-waves in electrocardiographic (ECG) signals is critical for the correct diagnosis of arrhythmias. We aimed to find the best bipolar lead (BL) with the highest signal amplitude and shortest inter-electrode spacing. METHODS: ECG signals (120 seconds) were recorded in 36 patients with 16 precordial electrodes placed in a standardized pattern. An average signal was analysed for each of 120 possible BLs obtained by calculating the difference between pairs of unipolar leads. Peak-to-peak amplitudes of QRS waves (50ms around R-peak) and P waves (270-70ms before R-peak) were calculated. For patients with atrial fibrillation, power of the fibrillatory (f) wave was used instead. Maximum values at each distance were considered and differentiation analysis was performed based on incremental changes (amplitude to distance). RESULTS: There was a significant correlation between distance and QRS-amplitude (r=0.78, p<0.001), P-wave amplitude (r=0.60, p<0.01) and f-wave power (r=0.79, p<0.001). The range of values was: QRS-amplitude 0.7-2.33mV, P-wave amplitude 0.07-0.18mV, and f-wave power 0.55-2.12mV(2)/s. The maximum value for the shortest distance was on a heart-aligned axis over the left ventricle for the QRS complex (1.9mV at 8.7cm) and over the atria for the P-wave (0.98mV) and f-waves (1.45mV(2)/s at 8cm, respectively). CONCLUSION: There is a strong positive correlation between electrode distance and ECG signal-amplitude. Distance of 8cm on a heart-aligned axis and over the relevant heart-chamber provides the highest signal amplitude for the shortest distance. These findings are essential for the design and use of ambulatory monitoring devices.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/métodos , Eletrodos , Idoso , Arritmias Cardíacas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco
5.
Europace ; 15(12): 1741-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23736806

RESUMO

AIMS: To provide a nationwide survey (and reference for the future) on cardiac electrophysiologists, types and numbers of invasive electrophysiological procedures, and training opportunities in 2010. METHODS AND RESULTS: German cardiology centres performing invasive electrophysiology were identified from quality reports and contacted to fill a questionnaire. A majority of 122 centres (65%) responded. Electrophysiology (ablation procedures and device therapy) was mainly part of a cardiology department (82%), and only in 9% independent (own budget). In only 58% of the centres, (at least) two physicians were present during catheter ablations. Although in 2010, women represented 59.4% of physicians <35 years old, only 26% of physicians in electrophysiology training were female. In total, 33 420 catheter ablations were performed with a median number of 180 per centre. Atrial fibrillation (AF) was the most common arrhythmia invasively treated (35%). At least 50 AF ablations were performed in 53% of the centres. Of the centres performing AF ablations, consecutive left atrial arrhythmias were treated by catheter ablation only in 75%, and only 44% had in-house surgical backup. Only one-fourth of the 122 centres fulfilled all requirements for training centre accreditation according to the European Heart Rhythm Association and the German Cardiac Society. CONCLUSION: The results indicate a high number of electrophysiology centres and procedures in Germany. Atrial fibrillation was the most common arrhythmia invasively treated. An increasing demand for catheter ablation is likely, but training opportunities are limited. Women are clearly underrepresented. A co-operation of higher and lower volume electrophysiology centres may be necessary for training purposes.


Assuntos
Arritmias Cardíacas/terapia , Serviço Hospitalar de Cardiologia/tendências , Cardiologia/tendências , Ablação por Cateter/tendências , Educação de Pós-Graduação em Medicina/tendências , Técnicas Eletrofisiológicas Cardíacas/tendências , Acreditação/tendências , Adulto , Arritmias Cardíacas/diagnóstico , Cardiologia/educação , Serviço Hospitalar de Cardiologia/estatística & dados numéricos , Ablação por Cateter/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Feminino , Alemanha , Pesquisas sobre Atenção à Saúde , Hospitais com Alto Volume de Atendimentos/tendências , Hospitais com Baixo Volume de Atendimentos/tendências , Humanos , Masculino , Médicas/tendências , Avaliação de Programas e Projetos de Saúde , Inquéritos e Questionários , Fatores de Tempo , Recursos Humanos
6.
J Magn Reson Imaging ; 33(2): 455-63, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21274989

RESUMO

PURPOSE: To prospectively determine the most reproducible approach for left-atrial size assessment using cardiovascular magnetic resonance (CMR) imaging in patients with atrial fibrillation and its value for prediction of pulmonary vein isolation (PVI) treatment success. MATERIALS AND METHODS: Eighty patients underwent CMR imaging prior to PVI; the CMR examination included standard cine sequences, a multislice cine sequence in 4-chamber orientation with full left-atrial coverage, and a contrast-enhanced MR angiography of the left atrium. Left-atrial size was determined as: diameter, area, volume segmented from angiography, and diastolic/systolic volumes from cine imaging (Simpson's rule). All measurements were carried out by two independent observers and repeated by one observer to assess inter- and intrareader variability. Treatment success was defined as persisting sinus rhythm after PVI (follow-up period 12.6 ± 6.6 months). RESULTS: All left-atrial measurements showed substantial intrareader agreement. Interreader agreement was substantial for diastolic/systolic left-atrial volumes only. Calculated bias was found to be minimal (0.1%-4.9%). Predictability of PVI treatment success was best using cine volumetric measurements (cutoff value for diastolic volume, 112 mL) yielding a sensitivity and specificity of 80% and 70%, respectively. CONCLUSION: Left-atrial volumetry based on cine imaging represented the most reproducible approach to determine left-atrial size. PVI success was predicted best using cine volumetry.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/patologia , Imagem Cinética por Ressonância Magnética/métodos , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
7.
Europace ; 13(9): 1340-5, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21486914

RESUMO

AIMS: Frequency analysis of atrial electrograms from patients diagnosed with persistent atrial fibrillation (AF) appears to be crucial in its clinical diagnosis. This work explores the fibrillatory frequency properties of both surface and intracardiac electrograms before and after pulmonary vein isolation (PVI) using three time-frequency techniques. METHODS AND RESULTS: Surface electrocardiograms (ECGs) of 21 patients diagnosed with persistent AF undergoing PVI were recorded. Three methods, Fourier, ensemble average, and wavelet analysis, were used to identify the dominant frequency (DF) in surface ECGs. Dominant frequency was also computed in electrograms recorded within the coronary sinus (CS). Dominant frequency measured within the CS was best estimated in surface lead V1 using both Fourier (relative error: 10.94 ± 10.37%, correlation: 0.58) and wavelet analysis (relative error: 10.97 ± 11.08%, correlation: 0.53). Ensemble average gave highest relative error (21.29 ± 18.07%) and lowest correlation (0.10). Dominant frequency decreased after right PVI. This decrease was significant (P< 0.05) in most of the patients (13, 14, and 7 out of 14 when Fourier, wavelets, and ensemble average was used; 14 in CS). Further isolation of the left pulmonary veins (PVs) yielded a significant (P< 0.05) decrease in only a few of them (3, 4, and 2 out of 14 when Fourier, wavelets, and ensemble average was used; 4 in CS). CONCLUSION: Wavelet and Fourier analysis are good tools for estimating the atrial fibrillatory rate from surface ECG. A drop was observed in the DF value after isolation of the right PV. However, after left PVI this decrease was smaller.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Seio Coronário/fisiopatologia , Eletrocardiografia/métodos , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Análise de Ondaletas
8.
Pacing Clin Electrophysiol ; 34(3): 315-22, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21087292

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation is facilitated by anatomical visualization of the left atrium (LA) and the pulmonary veins (PVs). The purpose of this study was to compare accuracy, radiation exposure, and costs between three-dimensional atriography (3D-ATG) and cardiac computed tomography (CCT). METHODS: Seventy patients with an indication for AF ablation were included. Contrast-enhanced CCT was performed preoperatively for all patients. In addition, intraoperative 3D-ATG was performed with contrast medium injection either indirectly into the pulmonary arteries during a breath-hold (Ind.-RTA, n = 25) or directly into the LA, during adenosine-induced asystole (Ad.-RTA, n = 23), or rapid ventricular pacing (VP-RTA, n = 22). We evaluated vertical ostial PV diameters and LA volume, time needed to perform, radiation exposure, and procedural cost for each imaging method. RESULTS: The correlation coefficient between 3D-ATG and CCT for the ostial PV diameters was r = 0.83 for Ind.-RTA, 0.91 for Ad.-RTA, and 0.88 for the VP-RTA method (P > 0.05). The volume correlations were r = 0.87 for Ind.-RTA, 0.82 for Ad.-RTA, and 0.8 for VP-RTA (P > 0.05). Time to perform was 13 ± 5 minutes for ATG and 46 ± 9 minutes for CCT (P < 0.05). Effective radiation dose was 2.2 ± 0.2 mSv for ATG and 20.4 ± 7.4 mSv for CCT (P < 0.05). The procedural cost was estimated at 91-95 € for ATG and at 126-151 € for CCT. CONCLUSIONS: 3D-ATG is an intraprocedural imaging modality that provides anatomical accuracy comparable to that of CCT with significantly lower radiation dose, in less time and at less financial expense (PACE 2011; 34:315-322).


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 21(6): 626-31, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20021514

RESUMO

INTRODUCTION: The study was designed to evaluate the feasibility and efficacy of a simplified cryoballoon technique in which a microcircular catheter was introduced into the central lumen of a cryoballoon catheter for the purpose of recording pulmonary vein (PV) potentials during ablation procedures and without interchanging catheters. METHODS AND RESULTS: A total of 23 consecutive patients with paroxysmal atrial fibrillation (AF) were enrolled. A single transseptal puncture was made and a cryoballoon catheter was inserted into the left atrium. A 6-pole mapping catheter with a 0.035-inch shaft diameter was introduced into the PV through the central lumen of the cryoballoon catheter. In addition to the function as a recording device, the mapping catheter was also used as a "guide-wire" during the procedure. A total of 84 PVs (84/92, 91.3%) were completely isolated using this novel cryoballoon technique. In 43 of the 84 veins (51.2%), isolation was observed in real time during the cryoablation; in the remaining 41 veins (48.8%), isolation was confirmed immediately post ablation attempt with the mapping catheter. Procedure time was 152.7 +/- 54.9 minutes, and fluoroscopy time was 33.2 +/- 17.3 minutes. At follow-up (7.4 months, range 2-18 months), 17 (73.9%) patients were free from AF. There was 1 occurrence of phrenic nerve palsy during ablation of a right superior PV, which fully resolved after 1 month. CONCLUSION: The use of a cryoballoon catheter equipped with a 6-pole micromapping catheter inserted through its central lumen for the purpose of mapping and ablation during PV isolation procedures is both feasible and effective.


Assuntos
Cateterismo Periférico/métodos , Criocirurgia/métodos , Veias Pulmonares/anatomia & histologia , Idoso , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Cateterismo Periférico/instrumentação , Estudos de Coortes , Temperatura Baixa , Ecocardiografia Transesofagiana , Eletrocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
10.
Europace ; 12(1): 37-44, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19919969

RESUMO

AIMS: Electrical isolation of the pulmonary veins (PVs) is the cornerstone of the ablative treatment of atrial fibrillation. Selective angiography of the PVs in standard fluoroscopic projections is often used for intraprocedural identification of PVs and their ostia. Variable spatial orientation and significant variability of PV anatomy are important limitations of this imaging approach. METHODS AND RESULTS: Sixty patients undergoing a PV isolation procedure received intraprocedural rotational angiography and three-dimensional reconstruction of the left atrium (LA) and PVs. For each patient, 33 angiographic projections were independently evaluated [right anterior oblique (RAO) 80 degrees to left anterior oblique (LAO) 80 degrees, in steps of 5 degrees] by two physicians in order to identify the optimal projections of the PV ostia according to the following definition: Sagittal plane: (i) clear identification of both superior and inferior segments of the LA-PV junction and (ii) no overlapping between LA (and/or left atrial appendage) and PV ostium. Frontal plane: (i) clear identification of all four quadrants of the PV ostium and (ii) fluoroscopic angles at which the maximal horizontal ostial diameter is visualized. A successful reconstruction of the LA and all PVs was obtained in 58 (97%) patients. An optimal ostial projection in a sagittal plane was identified for all four PVs. The optimal ostial projection was RAO 5 degrees for the right superior PVs in 57 out of 58 patients (98%), RAO 55 degrees for the right inferior PVs in 54 out of 58 patients (93%), LAO 45 degrees for the left superior PVs in 46 out of 58 patients (80%), and LAO 60 degrees for the left inferior PVs in 48 out of 58 patients (83%). An optimal ostial projection in a frontal plane was identified only for the inferior PVs. The optimal ostial projection was LAO 40 degrees for the right inferior PVs in 55 out of 58 patients (95%) and RAO 45 degrees for the left inferior PVs in 51 out of 58 patients (88%). CONCLUSION: If selective angiography is to be used to delineate anatomy and location of the PV ostia to guide PV isolation, different fluoroscopic projections are required for different PVs. The preselected RAO and LAO projections proposed in our study result in optimal angiographic projections of all PV ostia in at least one plane in the majority of patients.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Flebografia/métodos , Procedimentos de Cirurgia Plástica/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
11.
J Interv Card Electrophysiol ; 58(1): 21-27, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31230178

RESUMO

PURPOSE: Restoration of sinus rhythm in patients with persistent atrial fibrillation (ps. AF) induces reverse atrial remodeling and improvement of left ventricular function. We evaluated the effect of ablative treatment on cardiac remodeling after a long follow-up period of 7 years by cardiovascular magnetic resonance (CMR). METHODS: Patients with symptomatic ps. AF underwent CMR within 7 days prior to the ablation procedure. Left atrial and ventricular volumes were measured. All patients underwent circumferential pulmonary vein isolation. At the end of follow-up (FU), a CMR and 7-day ECG registration were performed. RESULTS: Forty-two patients (67 ± 9 years) were included. After a FU of 86 ± 13 months, 23 patients had a successful outcome. In these patients, LVEF improved from 56 ± 5 to 62 ± 4% (p = 0.02), but left atrial volume and ejection fraction (LAV, LAEF) remained unchanged (105 ± 25 to 98 ± 34, p = 0.44; 34 ± 10 to 36 ± 11, p = 0.6, respectively). In 14 patients with a BMI < 30 and no left ventricular hypertrophy (LVH), LAV decreased (104 ± 30 to 82 ± 26 ml, p = 0.01) and LAEF improved (33 ± 12 to 40 ± 11%, p = 0.03). In 9 patients with successful outcome and either BMI ≥ 30 or LVH, LAV increased (110 ± 26 to 125 ± 30 ml, p = 0.03) and LAEF deteriorated (35 ± 11 to 31 ± 10%, p = 0.04). CONCLUSIONS: Successful ablative treatment of atrial fibrillation is associated with reverse left atrial remodeling and improvement of left atrial and ventricular function. In patients with a BMI ≥ 30 or left ventricular hypertrophy, further left atrial enlargement occurs despite successful outcome.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento
12.
Europace ; 11(1): 35-41, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19054787

RESUMO

AIMS: Atrial fibrillation ablation is a complex procedure that requires detailed anatomic information about left atrium (LA) and pulmonary veins (PVs). The goal of this study was to test rotational angiography of the LA during adenosine-induced asystole as an imaging tool in patients undergoing atrial fibrillation ablation. METHODS AND RESULTS: Seventy patients with paroxysmal or persistent atrial fibrillation undergoing PV isolation were included. After transseptal puncture, adenosine (30 mg) was given intravenously, and during atrioventricular block, contrast medium was directly injected in the LA; a rotational angiography was performed (right anterior oblique 55 degrees to left anterior oblique 55 degrees). Rotational angiography images were assessed qualitatively in all patients and quantitatively in 45 patients in comparison with computed tomography (CT) images. The majority of rotational angiography imaging data (94%) were deemed at least 'useful' in delineating the LA-PV anatomy. The so-called 'ridge' between left superior PV and left atrial appendage was delineated in 90% of the patients. All accessory PVs were independently identified by rotational angiography and CT. A blinded quantitative comparison of PV ostial diameters showed an excellent correlation between rotational angiography and CT measurements (r > 0.90 for all PVs). No serious adverse effects occurred in association with adenosine. CONCLUSION: Intra-procedural contrast-enhanced rotational angiography of the LA-PV during adenosine-induced asystole is feasible and provides anatomical information of high diagnostic value for atrial fibrillation ablation.


Assuntos
Adenosina , Angiografia/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Iopamidol/análogos & derivados , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Ablação por Cateter/métodos , Meios de Contraste , Parada Cardíaca/induzido quimicamente , Parada Cardíaca/diagnóstico , Parada Cardíaca/cirurgia , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/métodos , Rotação , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Vasodilatadores
13.
Pacing Clin Electrophysiol ; 32(11): 1407-16, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19691678

RESUMO

BACKGROUND: Three-dimensional (3D) image of left atrium (LA) can greatly facilitate ablation of atrial fibrillation (AF). Reconstructing method using computed tomography (CT) has certain limitations. The 3D image of LA can be intraprocedurally reconstructed by a rotational angiography technique. METHODS: Forty-six patients undergoing AF ablation were included in this study. Preprocedural CT imaging and intraprocedural reconstructing 3D rotational angiogram (3DRA) of LA were performed in all the patients. Rapid ventricular pacing (RVP, 300 ms) was used to inhibit the drainage of atrium. During RVP, contrast medium was injected into the LA, and rotational angiography was performed. The 3DRA was reconstructed and was registered with the live fluoroscopy. The 3DRA was evaluated in comparison to the CT image. In the navigation of the registered 3DRA, the ablation of AF was performed. RESULTS: Forty-four 3DRAs (95.7%) were successfully reconstructed and registered with the live fluoroscopy. The LA anatomy was delineated in the 3DRA in comparison to a CT image. AF ablation was successfully performed in the 44 patients in the navigation of the registered 3DRA. There were good correlations in the PV ostial diameter and the LA volume as assessed by 3DRA in comparison to a CT image (r>=0.87). The radiation exposure in rotational angiography was substantially less than that in CT scanning (2.7+/-0.9 mSv vs. 24.9+/-3.1 mSv, P<0.001). CONCLUSIONS: It is feasible to reconstruct and register the 3DRA with live fluoroscopy using the RVP method during the ablation of AF.


Assuntos
Angiografia/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
14.
Am J Cardiol ; 101(3): 407-12, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-18237610

RESUMO

We sought to investigate the value of cardiac magnetic resonance to depict cardiac venous anatomy. For cardiac resynchronization therapy the lead for the left ventricle is usually placed by transvenous approach into a tributary of the coronary sinus (CS). Knowledge of the anatomy and variations of the cardiac venous system may facilitate the positioning of the left ventricle lead. The cardiac magnetic resonance examinations of 23 subjects (16 volunteers and 7 patients) were retrospectively analyzed. All examinations were performed using navigator-gated whole-heart steady-state free precession coronary artery imaging after administration of intravascular contrast agents (gadofosveset in volunteers; Gadomer-17 in patients). The cardiac venous system was visualized in all subjects. The most frequent anatomical variant observed (in 12 subjects [52%]) was a connection of the small cardiac vein to the CS at the crux cordis. In 10 subjects (44%) the small veins entered the right atrium independently from the CS, and the posterior interventricular vein was connected to the CS at the crux cordis. Only one subject had a disconnection between the CS and posterior interventricular vein, which entered into the right atrium independently. The mean distance of the posterior vein of the left ventricle and the left marginal vein to the ostium of the CS was 15.2+/-4.7 mm and 49.7+/-14.1 mm, respectively. In conclusion, the anatomy of the cardiac venous system and its anatomical variability can be described using cardiac magnetic resonance. Its preimplantation visualization may help to facilitate the implant procedure and to reduce fluoroscopy time.


Assuntos
Vasos Coronários/anatomia & histologia , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Retrospectivos
15.
Europace ; 10(6): 698-704, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18403384

RESUMO

AIMS: The purpose of this study was to evaluate a retrograde approach for radiofrequency (RF) ablation of ectopic atrial tachycardias (EATs) with an early atrial activation at the His site. METHODS AND RESULTS: This study included 12 patients with EAT. During tachycardia, earliest atrial activation was recorded at the His site at a standard catheter setting. Activation mapping was performed in the right atrium and along the mitral annulus and at the aortic root after retrograde insertion of the ablation catheter over the ascending aorta. In five patients, earliest atrial activation was recorded at the mitral annulus (in two patients at the superior-lateral annulus and in three patients at the inferior-medial annulus). In four of these patients, EAT could be successfully treated by RF ablation through the retrograde approach, whereas in one patient, a transseptal puncture was performed in order to achieve a stable catheter position. In seven patients, RF ablation at the non-coronary aortic sinus eliminated the tachycardia. During a follow-up period of 14 +/- 8 months, there was no tachycardia recurrence. CONCLUSION: In patients with EATs and early atrial activation at the His site, tachycardia may arise in the non-coronary aortic sinus or from the mitral annulus. Radiofrequency energy ablation can be performed through a retrograde approach in the majority of these patients and is safe and effective in eliminating this type of tachycardia.


Assuntos
Fascículo Atrioventricular/cirurgia , Ablação por Cateter/métodos , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/cirurgia , Humanos , Estudos Longitudinais , Resultado do Tratamento
16.
J Electrocardiol ; 41(6): 553-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18817922

RESUMO

Atrial fibrillation (AF) is the most common clinical cardiac arrhythmia and is usually treated with the electrical isolation of the pulmonary veins from the atria. However, it is estimated that about 30% of the patients undergoing this therapy will develop AF again. The purpose of this study was to test the dynamic changes of the spectra calculated in surface electrocardiograms (ECGs) before and after the ablation of the pulmonary veins. Surface ECGs of 14 patients with persistent AF undergoing this intervention were considered for this study. The QRS-T waves were subtracted from the ECGs using common spatial pattern, isolating the electrical activity of the atrium. The spectrum was then calculated and the main frequency peaks were identified. The smaller peaks with amplitude below 50% of the maximum were discarded. Eleven of the patients were followed up after the intervention for 1 to 6 months. Two of the patients developed AF again; the other 9 remained in sinus rhythm. For most of the patients, the spectrum showed more order after the intervention. However, the main frequency did not experience a significant decrease in average (5.1 Hz [+/-1.3] to 4.9 Hz [+/-1.0]). Interestingly, the increment or decrease of the main frequency did not correlate with the recurrence of AF or not.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Cuidados Pré-Operatórios/métodos , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
17.
JACC Clin Electrophysiol ; 4(6): 820-827, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29929676

RESUMO

OBJECTIVES: This study provides an update and comparison to a 2010 nationwide survey on cardiac electrophysiology (EP), types and numbers of interventional electrophysiological procedures, and training opportunities in 2015. BACKGROUND: In 2010, German cardiology centers performing interventional EP were identified and contacted to provide a survey on cardiac EP. METHODS: German cardiology centers performing interventional EP in 2015 were identified from quality reports and contacted to repeat the 2010 questionnaire. RESULTS: A majority of 131 centers (57%) responded. EP (ablation procedures and device therapy) was mainly part of a cardiology department (89%) and only independent (with its own budget) in 11%. The proportion of female physicians in EP training increased from 26% in 2010 to 38% in 2015. In total, 49,356 catheter ablations (i.e., 81% of reported ablations in 2015) were performed by the responding centers, resulting in a 44% increase compared with 2010 (the median number increased from 180 to 297 per center). Atrial fibrillation (AF) was the most common arrhythmia interventionally treated (47%). At 66% of the centers, (at least) 2 physicians were present during most catheter ablations. A minimum of 50 (75) AF ablations were performed at 80% (70%) of the centers. Pulmonary vein isolation with radiofrequency point-by-point ablation (62%) and cryoablation (33%) were the preferred ablation strategies. About one-third of centers reported surgical AF ablations, with 11 centers (8%) performing stand-alone surgical AF ablations. Only one-third of the responding 131 centers fulfilled all requirements for training center accreditation. CONCLUSIONS: Comparing 2010 with 2015, an increasing number of EP centers and procedures in Germany are registered. In 2015, almost every second ablation was for therapy for AF. Thus, an increasing demand for catheter ablation is likely, but training opportunities are still limited, and most centers do not fulfil recommended requirements for ablation centers.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Adulto , Eletrofisiologia Cardíaca/educação , Eletrofisiologia Cardíaca/organização & administração , Eletrofisiologia Cardíaca/estatística & dados numéricos , Feminino , Alemanha/epidemiologia , Pessoal de Saúde/educação , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade
19.
J Interv Card Electrophysiol ; 42(2): 101-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25591723

RESUMO

BACKGROUND: Recurrence of atrial fibrillation (AF) after ablative treatment is common. We hypothesized that AF recurrence is heralded by fast ectopic atrial activity occurring after electrical reconnection of previously isolated pulmonary veins. METHODS: Patients with paroxysmal or persistent AF undergoing pulmonary vein isolation (PVI) were followed up by 24-h Holter monitoring every 3 months for the first year and every 6 months thereafter. Antiarrhythmic drugs were withdrawn after a blanking period of 4 weeks for paroxysmal and 3 months for persistent AF. Ectopic atrial activity was defined as a burden of atrial extrasystoles >5% of the total QRS number. Fast atrial activity was present if mean cycle length of ectopic atrial activity was shorter than 50% of the mean cycle length of sinus rhythm in the last ten heartbeats. Patients with symptomatic fast atrial activity but without AF recurrence were randomized to undergo a second PVI procedure or resume antiarrhythmic medication. During follow-up, a 24-h Holter recording was performed every 3 months. Additionally, a 7-day external loop recording was performed in every pt with palpitations and no AF or ectopic atrial activity in the 24-h Holter. RESULTS: One hundred twenty-four pts with AF (88 paroxysmal, 36 persistent) developed fast atrial activity 6 ± 3 months after PVI. Twenty-two pts were asymptomatic and eight pts refused randomization. Ninety-four pts (61 men, age 57 ± 12 years) were randomized to either receive a second PVI procedure (group I, 48 pts) or antiarrhythmic medication (group II, 46 pts). Re-PVI in group I was performed 10 ± 8 months after the first PVI. During a follow-up of 20 ± 6 months, 11 pts of group I (23%) and 43 pts of group II (93%) had recurrence of AF. The mean time of AF recurrence after appearance of fast atrial activity was 4 ± 2 in group I and 5 ± 3 months in group II. CONCLUSIONS: In patients with atrial fibrillation and after the first PVI procedure, appearance of symptomatic fast atrial activity is associated with a high risk of AF recurrence. Re-isolation of reconnected pulmonary veins in these pts significantly reduces the risk of AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial/métodos , Eletrocardiografia/métodos , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/mortalidade , Ablação por Cateter/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Veias Pulmonares/patologia , Recidiva , Reoperação/métodos , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
20.
J Interv Card Electrophysiol ; 42(2): 125-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25591726

RESUMO

BACKGROUND: Precise knowledge of the coronary sinus (CS) tree anatomy facilitates catheter-based intubation of the CS, target vein and lead selection and reduces the need for fluoroscopy, contrast medium and overall procedure time in cardiac resynchronization therapy (CRT). Three-dimensional rotational angiography (3DRA) provides a new means of multiangle imaging of the CS tree that can be applied preoperatively. PURPOSE AND METHODS: Our study aims to investigate the feasibility of preoperative rotational CS venography and its implications for CRT device implantation procedures. For this purpose, CS visualization was done either conventionally with retrograde CS venography and standard fluoroscopic views (SFV, n = 30), or with antegrade CS imaging via contrast medium injection into the left coronary artery using 3DRA in the venous phase of contrast flow (3DRA, n = 30). RESULTS: 3DRA successfully identified the posterior and left marginal veins in 92% of patients and allowed target vein visualization in 86%. Additional retrograde venography was necessary in four patients (14%). Fluoroscopy time and contrast medium administration for stable CS intubation were lower in the group with 3DRA than in those with SFV (all p < 0.05). The time for CS lead placement after guiding catheter intubation was 8.9 ± 5.5 min in the 3DRA group versus 14.7 ± 7.4 min in SFV patients (p < 0.05). Consequently, total fluoroscopy time (-12.1 min), volume of contrast medium (-29.5 ml) and overall procedure time (-32.8 min) were significantly lower in 3DRA than in SFV patients (p < 0.05). CONCLUSION: 3DRA offers reliable multiangle visualization of the CS anatomy and facilitates successful CRT lead implantation.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Seio Coronário/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Imageamento Tridimensional/métodos , Idoso , Angiografia/métodos , Eletrodos Implantados , Feminino , Fluoroscopia/métodos , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Flebografia/métodos , Estudos Prospectivos , Rotação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA