1.
ESC Heart Fail ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38741373

RESUMO

AIMS: Worsening heart failure (WHF) events occurring in non-inpatient settings are becoming increasingly recognized, with implications for prognostication. We evaluate the performance of a natural language processing (NLP)-based approach compared with traditional diagnostic coding for non-inpatient clinical encounters and left ventricular ejection fraction (LVEF). METHODS AND RESULTS: We compared characteristics for encounters that did vs. did not meet WHF criteria, stratified by care setting [i.e. emergency department (ED) and observation stay]. Overall, 8407 (22%) encounters met NLP-based criteria for WHF (3909 ED visits and 4498 observation stays). The use of an NLP-derived definition adjudicated 3983 (12%) of non-primary HF diagnoses as meeting consensus definitions for WHF. The most common diagnosis indicated in these encounters was dyspnoea. Results were primarily driven by observation stays, in which 2205 (23%) encounters with a secondary HF diagnosis met the WHF definition by NLP. CONCLUSIONS: The use of standard claims-based adjudication for primary diagnosis in the non-inpatient setting may lead to misclassification of WHF events in the ED and overestimate observation stays. Primary diagnoses alone may underestimate the burden of WHF in non-hospitalized settings.

2.
Struct Heart ; 8(2): 100237, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481714

RESUMO

Background: The eligibility and potential benefit of transcatheter edge-to-edge repair (TEER) in addition to guideline-directed medical therapy to treat moderate-severe or severe secondary mitral regurgitation (MR) has not been reported in a contemporary heart failure (HF) population. Methods: Eligibility for TEER based on Food and Drug Administration (FDA) labeling: (1) HF symptoms, (2) moderate-severe or severe MR, (3) left ventricular ejection fraction (LVEF) 20% to 50%, (4) left ventricular end-systolic dimension 7.0 cm, and (5) receiving GDMT (blocker + angiotensin-converting enzyme inhibitor/angiotensin receptor blocker). The proportion (%) of patients eligible for TEER. The hypothetical number needed to treat to prevent or postpone adverse outcomes was estimated using relative risk reductions from published hazard ratios in the registration trial and the observed event rates. Results: We identified 50,841 adults with HF and known LVEF. After applying FDA criteria, 2461 patients (4.8%) were considered eligible for transcatheter mitral valve replacement (FDA+), with the vast majority of patients excluded (FDA-) based on a lack of clinically significant MR (N = 47,279). FDA+ patients had higher natriuretic peptide levels and were more likely to have a prior HF hospitalization compared to FDA- patients. Although FDA+ patients had a more dilated left ventricle and lower LVEF, median (25th-75th) left ventricular end-systolic dimension (cm) was low at 4.4 (3.7-5.1) and only 30.8% had severely reduced LVEF. FDA+ patients were at higher risk of HF-related morbidity and mortality. The estimated number needed to treat to potentially prevent or postpone all-cause hospitalization was 4.4, 8.8 for HF hospitalization, and 5.3 for all-cause death at 24 months in FDA+ patients. Conclusions: There is a low prevalence of TEER eligibility based on FDA criteria primarily due to absence of moderate-severe or severe MR. FDA+ patients are a high acuity population and may potentially derive a robust clinical benefit from TEER based on pivotal studies. Additional research is necessary to validate the scope of eligibility and comparative effectiveness of TEER in real-world populations.

3.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional