Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Carcinogenesis ; 38(5): 570-578, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28498946

RESUMO

Cancer development often involves mutagenic replication of damaged DNA by the error-prone translesion synthesis (TLS) pathway. Aberrant activation of this pathway plays a role in tumorigenesis by promoting genetic mutations. Rev1 controls the function of the TLS pathway, and Rev1 expression levels are associated with DNA damage induced cytotoxicity and mutagenicity. However, it remains unclear whether deregulated Rev1 expression triggers or promotes tumorigenesis in vivo. In this study, we generated a novel Rev1-overexpressing transgenic (Tg) mouse and characterized its susceptibility to tumorigenesis. Using a small intestinal tumor model induced by N-methyl-N-nitrosourea (MNU), we found that transgenic expression of Rev1 accelerated intestinal adenoma development in proportion to the Rev1 expression level; however, overexpression of Rev1 alone did not cause spontaneous development of intestinal adenomas. In Rev1 Tg mice, MNU-induced mutagenesis was elevated, whereas apoptosis was suppressed. The effects of hREV1 expression levels on the cytotoxicity and mutagenicity of MNU were confirmed in the human cancer cell line HT1080. These data indicate that dysregulation of cellular Rev1 levels leads to the accumulation of mutations and suppression of cell death, which accelerates the tumorigenic activities of DNA-damaging agents.


Assuntos
Adenoma/etiologia , Apoptose/genética , Carcinógenos/toxicidade , Expressão Gênica , Neoplasias Intestinais/etiologia , Nucleotidiltransferases/genética , Mutação Puntual , Adenoma/patologia , Alelos , Animais , Linhagem Celular Tumoral , Transformação Celular Neoplásica/induzido quimicamente , Transformação Celular Neoplásica/genética , Dano ao DNA , DNA Polimerase Dirigida por DNA , Modelos Animais de Doenças , Progressão da Doença , Frequência do Gene , Genótipo , Neoplasias Intestinais/mortalidade , Neoplasias Intestinais/patologia , Masculino , Camundongos , Camundongos Transgênicos , Carga Tumoral
2.
J Phys Chem B ; 125(11): 2987-2993, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33724819

RESUMO

Several fluorescence patterns derived from the excimer states of perylene have been reported, but most of these have been obtained from rigid forms such as crystals or for perylene embedded in hard polymers. We observed perylene excimer emission on absorption of water by a poly-N-isopropylacrylamide gel containing perylene molecules, which were not fixed to the gel framework by chemical bonding. We propose that this emission arises because the hydrophobic perylene molecules cannot dissolve in water and form aggregates. The perylene aggregation was quickly lost on dehydration of the gel, and the luminescence reverted to that of the monomer. In a dehydrated environment, perylene was rapidly dispersed in the gel network. In other words, solid-liquid phase separation of perylene was induced by uptake of water into the gel, and perylene dissolved in the gel on dehydration. Because the outside of the gel is always in an aqueous environment, perylene will remain semipermanently in the gel. Therefore, monomer emission and excimer emission can be switched reversibly and repeatedly.

3.
Arch Oral Biol ; 51(2): 146-53, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16098475

RESUMO

OBJECTIVE: The multipennate masseter has a complex internal architecture, which suggests the contraction is not uniform within the muscle. The heterogeneous contraction may cause inequable changes of the muscle's outer shape. This study aimed to elucidate the outer shape changes of the whole masseter with clenching by multipoint measurement of serial ultrasound images. DESIGN: Serial coronal images (perpendicular to the FH plane, 3 mm interval) of the right masseter of five healthy men were obtained with a real-time ultrasonograph equipped with a 13 MHz linear-array transducer. To define the relationship between the transducer and cranium, we used a 3D mechanical stage with a face-bow. Registrations were made during muscle relaxation and maximal clenching. The distance between the lateral and medial outlines of the muscle was measured at intervals of 1mm from the origin to insertion in each image as the thickness at the corresponding measured point. RESULTS: The thickness of the relaxed and contracted muscle (R and C) and its difference (Delta) varied among the measured points. Muscle thickness at most measured sites increased with clenching, whereas it decreased at several sites, mainly near the origin and insertion. There were positive correlations in every subject both between R and C, and between C and Delta. On the other hand, the correlation between R and Delta were negative or weak. CONCLUSION: Changes of thickness with clenching showed great disparity within the masseter, which may result from the complexity of the contraction properties due to the multipennate structure and functional heterogeneity.


Assuntos
Músculo Masseter/fisiologia , Contração Muscular , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Músculo Masseter/anatomia & histologia , Músculo Masseter/diagnóstico por imagem , Relaxamento Muscular/fisiologia , Ultrassonografia
4.
Int J Prosthodont ; 27(5): 469-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25191891

RESUMO

This study aimed to investigate the pressure distribution beneath the denture bases of removable partial dentures (RPDs) with different occlusal rest designs (ORDs) by in vivo measurement. Four types of detachable occlusal rests (mesial and distal, distal, mesial, and nonrest) were placed on the direct abutment teeth of distal extension RPDs in four patients with free-end edentulous mandibles. Pressure measurements were obtained by using thin and flexible tactile sensors. The results showed significant variances with different ORDs in all four patients (P < .05), leading to the conclusion that the pressure distribution on the residual ridge beneath the RPD base was dependent on the ORD.


Assuntos
Bases de Dentadura , Planejamento de Dentadura , Prótese Parcial Removível , Força de Mordida , Dente Suporte , Retenção de Dentadura/instrumentação , Humanos , Pressão , Propriedades de Superfície
5.
J Prosthodont Res ; 53(1): 15-21, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19318066

RESUMO

PURPOSE: To develop a system to measure the pressure distribution under the base of a removable partial denture (RPD) and to apply it in vivo. METHODS: A tactile sensor sheet with 100 sensing points and a measuring system (I-SCAN, Nitta, Osaka, Japan) were used. The sensor was calibrated before being applied in vivo. A subject with a mandibular RPD (Kennedy class II, division 1) participated in this study, and the RPD was duplicated as the experimental denture. The basal surface at distal extension was accommodated to the sensor in a manner similar to direct relining. Measurements were performed with three patterns of occlusal rest design (mesial and distal rests, mesial rest only, and without a rest) during maximal voluntary clenching (MVC) and gum chewing. RESULTS: The calibration measurements showed that the output value from each sensing point and total output of sensing points were positively correlated with the applied load. The pressures recorded in vivo varied depending on the locations of sensing points on the basal surface of the denture. During MVC the pressure distribution changed with the clenching level, and the highest pressure was registered near the residual ridge crest. The pressure distribution also changed according to the number of occlusal rests. The load center shifted about 2mm during MVC and about 4mm during gum chewing. CONCLUSION: The measuring system developed here enabled us to measure the pressure distribution under the denture base of RPD. The pressure distribution varied along with the design of the occlusal rest.


Assuntos
Força de Mordida , Dente Suporte , Análise do Estresse Dentário/métodos , Prótese Parcial Removível , Mastigação/fisiologia , Pressão , Idoso , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA