Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Cardiol Young ; 31(11): 1819-1822, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33752766

RESUMO

An 11-year-old male was admitted with cough and fever for the last 4 days and also complained of pain in the right lung for some weeks. The boy did not show any other symptoms and his past medical history was unremarkable as well. The radiologist findings showed an aspect that suggested for echinococcosis.At first, it was realised the heart intervention. About a 2-month period later, the child underwent another cyst removal in lung. He had begun taking albendazole 5 days before the heart intervention. The therapy was continued until the lung intervention and for 12 weeks post-operatively. The patient had an uneventful recovery and after about 4 years.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Equinococose , Albânia , Albendazol/uso terapêutico , Criança , Equinococose/diagnóstico , Equinococose/tratamento farmacológico , Equinococose/cirurgia , Humanos , Pulmão , Masculino
2.
J Perioper Pract ; : 17504589241234191, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38595040

RESUMO

AIM OF THE STUDY: To evaluate the effect of intraoperative positive end-expiratory pressure and driving pressure on the development of postoperative pulmonary complications. METHOD: The prospective study included 83 patients undergoing abdominal surgery and receiving general anaesthesia. Patients were divided into two groups: with low intraoperative positive end-expiratory pressure (0-2cm H2O) and with high intraoperative positive end-expiratory pressure (8-10cm H2O). The primary endpoint is the development of postoperative pulmonary complications during follow-up. RESULTS: The incidence of postoperative pulmonary complications in the group of low intraoperative positive end-expiratory pressure was 9.8%, while in the group of high positive end-expiratory pressure was 7.1% (p = 0.6), demonstrating that high positive end-expiratory pressure used during general anaesthesia does not affect the frequency of complications (odds ratio = 0.71, p = 0.6). In the multivariate analysis that controls for all confounders, driving pressure resulted in a significant and independent risk factor for complications. CONCLUSION: High intraoperative positive end-expiratory pressure does not affect the frequency of postoperative pulmonary complications. The increase in driving pressure is a risk factor for complications. Positive end-expiratory pressure is easily implemented, and its use does not result in significant economic costs.

3.
Braz J Cardiovasc Surg ; 37(6): 932-936, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35657306

RESUMO

Severe functional mitral valve regurgitation should be treated in patients undergoing myocardial revascularization. When replacement is considered the best therapeutic option, preservation of the mitral subvalvular apparatus is crucial, especially in the emergency setting, because of its primary role in preserving geometry and function of left and right ventricles. Here we present a simple and quick technique, where subvalvular apparatus is preserved in toto in patients undergoing mitral valve replacement with a bioprosthesis.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia
4.
Cureus ; 14(3): e23663, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35371867

RESUMO

Pneumoperitoneum after cardiac surgery is not usual. It occurs during extended sternotomy, which is sometimes accompanied by the opening of the peritoneal cavity or in cases after previous sternotomies. A 73-year-old man was operated on two times within one month due to prosthetic mitral valve dehiscence. The second operation was accompanied by a lot of complications, including blood loss, respiratory failure, massive pleural effusion, sternal infection, pneumomediastinum, and pneumoperitoneum. The presence of pneumoperitoneum alerted the possibility of intra-abdominal cavitary organ perforation. No surgical approach was chosen because there were no signs of peritonitis. The patient was discharged to home in a good health situation. Sixteen months later, he was recovered at the hospital for heart failure, and after abdominal CT, benign pneumoperitoneum was observed in the abdominal cavity again. There was no explanation for this finding, but again conservative treatment was chosen. He was discharged for the third time from the hospital in good condition.

5.
J Med Eng Technol ; 45(3): 197-206, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33754927

RESUMO

Mitral valve repair is typically performed by implanting a ring-like device at the valve annulus to reshape the annulus and to improve leaflet coaptation. In most cases, some additional procedures are needed, including leaflet resection and artificial chordae implantation. However, artificial chordae implantation could be technically challenging and postoperative left ventricular remodeling could increase the risk of recurrent mitral regurgitation. We propose an innovative annular device made of chromo-cobalt, finalized not only to reshape the annulus but also to enable anchoring of leaflets to a fixed intraventricular structure. Durability evaluation of the device was tested by applying eight radial force vectors equally spaced along the ring and related fatigue analysis. To evaluate the efficacy of the mitral valvuloplasty using the tested ring, the device was implanted in five adult swine hearts. Functional analysis of the ring was performed by measuring left ventricular pressure and fluid volume loss, following implantation in normal and dysfunctional mitral valve leaflets. Both fatigue and functional analysis showed satisfactory and promising results in terms of durability and efficacy of mitral valve repair. Because of its favorable durability and functional characteristics this device appears promising and provides good results in terms of valve competence, thus avoiding both manipulations of papillary muscles and interference in left ventricular hemodynamics. However, an in vivo test is mandatory to fully understand the impact of the device on subvalvular apparatus.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Hemodinâmica , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Suínos
6.
Aorta (Stamford) ; 8(2): 25-28, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32736400

RESUMO

BACKGROUND: Despite improvements in operative techniques, open thoracoabdominal aortic aneurysm (TAAA) repair is complex and characterized by high mortality and morbidity rate. Less invasive techniques have been developed since 2005 for the treatment of TAAA. Unfortunately, many of these devices require custom fabrication, resulting in delay of many weeks until treatment can be delivered but crucial in critical emergency cases. We present a novel hybrid endovascular and surgical prosthesis, which was tested on five pigs, with the aim of reducing the barrier issues of endovascular therapy in such particular cases. METHODS: The principal characteristic of the proposed hybrid endovascular prosthesis is to combine a proximal and distal stented zones and, in between, a classical surgical blood tied Dacron prosthesis. The device was tested in five pigs where feasibility of implantation and acute postoperative outcomes were evaluated, including bleeding, bowel ischemia, renal function, and peripheral blood perfusion. RESULTS: In all cases, following laparotomy, the endoprosthesis was successfully implanted under fluoroscopy and the surgical prosthesis zone could be easily detected by the radio-opaque markers. No major bleeding or cardiac events occurred throughout preparation and implantation. One hour after prosthesis implantation and surgical anastomoses of all vessels were completed, normal urine output was registered, and no acidosis was detected. CONCLUSIONS: This novel graft has shown ease of endoprosthesis and visceral vessels implantation without the need of thoracotomy or extracorporeal circulation and may be useful in an emergency setting or high risk and complex anatomy TAAA unsuitable for traditional endovascular aneurysm repair, or to avoid an excess waiting time for a "custom made" prosthesis. The great adaptability of this "hybrid" prosthesis in complex anatomy for the majority of TAAA could be important in high-risk patients and in some difficult situations, such as a high risk of imminent rupture.

7.
Rev. bras. cir. cardiovasc ; 37(6): 932-936, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407320

RESUMO

ABSTRACT Severe functional mitral valve regurgitation should be treated in patients undergoing myocardial revascularization. When replacement is considered the best therapeutic option, preservation of the mitral subvalvular apparatus is crucial, especially in the emergency setting, because of its primary role in preserving geometry and function of left and right ventricles. Here we present a simple and quick technique, where subvalvular apparatus is preserved in toto in patients undergoing mitral valve replacement with a bioprosthesis.

8.
Open Access Maced J Med Sci ; 5(1): 23-26, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-28293311

RESUMO

AIM: Patient-prosthesis mismatch (PPM) is a common occurrence in aortic valve surgery. Even the discussions about the impact of this phenomenon on the results of aortic valve surgery, the management of this problem remain one of the main topics in this kind of surgery. One of the ways of a solution is aortic annulus enlargement. The main topic of this study is to evaluate the early and longterm results of this technique in our country. METHODS: During the period January 2010 -January 2015, 641 patients performed aortic valve surgery. In ten patients we performed aortic annulus enlargement according to Manouguian technique to avoid severe patient-prothesis mismatch. Operative mortality and perioperative complications (low cardiac output, pulmonary complications, etc..) were considered the indicators of the early results. Survival, clinical presentation according to NYHA, quality of life were the indicators to evaluate long-term results. Preoperative and postoperative echocardiographic data were also used to evaluate our results. We collected the data from hospital registrations and periodical clinical visit and echographic examination after hospital discharge. RESULTS: In our group, 6 of 10 patients were diagnosed with stenotic aortic valve, two patients had aortic valve regurgitation and two mixed valve pathology. Four patients had concomitant cardiac surgery procedure, mitral or CABG. In all cases, aortic valve pathology was the primary diagnose. In the preoperative echocardiographic examination mean transvalvular gradient was 54.3 ± 6.42. We had no death during early or late postoperative period. Only one patient had pulmonary complications and long time of respiratory assistance because of his pulmonary pathology. The same patient had low cardiac output and wound infection. Early after surgery mean transprostethic gradient was 16.2 ± 3.44 and late postoperative was 15.9 ± 4.3. No patient had the severe patient-prothesis mismatch. Mean follow-up was 49 ± 20.26 months. During follow-up, we had no death, and all patients had very good quality of life. CONCLUSIONS: Aortic valve annulus enlargement can be used with very good early and late results with the final goal to increase the potential benefit of the patient from surgery of aortic valve.

9.
Ann Thorac Surg ; 99(1): e3-5, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25555985

RESUMO

A 22-year-old man was referred for severe aortic coarctation. Contrast-enhanced computed tomography confirmed the aortic coarctation diagnosis and showed an aortic pseudoaneurysm arising from the anterior and left surface of the descending aorta, communicating with the aortic lumen with a small neck. Under cardiopulmonary bypass through the femoral vessels, the patient underwent closure of the pseudoaneurysm neck using a synthetic patch and interposition of a prosthetic graft between the left subclavian artery and the descending aorta below the pseudoaneurysm. The patient's postoperative course was uneventful.


Assuntos
Falso Aneurisma/complicações , Aorta Torácica , Coartação Aórtica/complicações , Doenças da Aorta/complicações , Humanos , Masculino , Índice de Gravidade de Doença , Adulto Jovem
10.
Interv Med Appl Sci ; 6(3): 104-10, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25243075

RESUMO

OBJECTIVES: The aim of this study is to report our experience on the postoperative outcome of surgical treatment of inflammatory abdominal aortic aneurysm (IAAA). MATERIALS AND METHODS: Between 1997-2014, 35 patients with IAAA underwent surgery. The mean age was 63 ± 18 years. Chronic renal failure was identified in 11 (31.4%) patients and confirmed ischemic heart disease in 15 (43%) patients. The mean aortic aneurysm diameter was 68 ± 25 mm. The abdominal aorta was clamped above the renal arteries in 6 (17%) patients. RESULTS: The hospital mortality was 5.7% (2 patients). Three patients developed an aortic pseudoaneurysm and underwent a redo operation. Another patient developed a femoral anastomotic pseudoaneurysm 7 years after operation and he was treated surgically. The actuarial free-reoperation actuarial survival at 1, 5 and 7 years was 94%, 62% and 50%, respectively. The Cox model revealed the delta erythrocyte sedimentation rate (p = 0.002), ischemic heart disease (p = 0.006) and renal failure (p = 0.036) as strong predictors for poor overall outcome. CONCLUSION: Early postoperative outcome in terms of mortality and morbidity seems acceptable, however, patients with IAAA have an increased risk for reoperation due to pseudonaneurysm formation. Strong predictors for poor overall outcome seem to be the elevated erythrocyte sedimentation rate, ischemic heart disease and chronic renal failure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA