1.
Eur Radiol ; 32(10): 6859-6867, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35778509

RESUMO

OBJECTIVES: Vorticity calculated using computational fluid dynamics (CFD) could assess the flow disturbance generated by coronary stenosis. The purpose of this study was to investigate whether vorticity would be an underlying cause of functionally significant stenosis assessed by invasive fractional flow reserve (FFR). METHODS: This retrospective study included 113 patients who underwent coronary CT angiography showing intermediate stenosis and subsequent invasive FFR between December 2015 and March 2020. Vorticity at the stenosis site was calculated using a mesh-free CFD method. We also evaluated the minimum lumen area (MLA) and diameter stenosis (DS) of the lesion. Invasive FFR of ≤ 0.80 was considered functionally significant. Data were compared using Student's t-test and logistic regression analysis was performed. RESULTS: Of the evaluated 144 vessels, 53 vessels (37%) showed FFR ≤ 0.80. Vorticity of significant stenosis was significantly higher than non-significant stenosis (569 ± 78 vs. 328 ± 34 s-1, p < 0.001). A significant negative relationship was present between vorticity and invasive FFR (R2 = 0.31, p < 0.001). Multivariate logistic regression analysis including MLA and DS showed that vorticity (per 100 s-1, odds ratio: 1.36, 95% confidence interval: 1.21-1.57, p < 0.001) was a statistically significant factor to detect functional significance. The area under the receiver operating characteristic curve statistically significantly increased when vorticity was combined with DS and MLA (0.76 vs. 0.87, p = 0.001). CONCLUSIONS: Vorticity had a statistically significant negative relationship with invasive FFR independent of geometric stenosis. KEY POINTS: • Flow disturbance caused by coronary stenosis could be evaluated by calculating vorticity which is defined as the norm of the rotation of the velocity vector. • Vorticity was statistically significantly higher in stenosis with functional significance than stenosis without. • Vorticity has an additive value to detect functionally significant stenosis over geometrical stenosis.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Constrição Patológica/patologia , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
2.
Heart Vessels ; 36(4): 461-471, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33219413

RESUMO

BACKGROUND: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are useful in determining indications for revascularization of coronary artery disease (CAD). Although the discordance of FFR and iFR was noted in approximately 20%, this cause has not been well established. We investigated patient background and features on coronary CT angiography (CCTA) showing not only FFR- and iFR-positive findings but also discordance between FFR ≤ 0.8 and iFR ≤ 0.89. METHODS: Subjects were consecutively treated in 83 cases with 105 vessels in which stenosis of 30-90% was detected at one vessel of at least 2 mm or more in the major epicardial vessels and FFR and iFR was performed within subsequent 90 days, among suspected CAD which underwent CCTA. The factors affecting not only FFR- and iFR-positive findings, respectively, but also discordance between FFR and iFR was evaluated using logistic regression analysis on per-patient and per-vessel basis. RESULTS: FFR- and iFR-positive findings were observed in 42 vessels (40.0%) and 34 vessels (32.3%), respectively. Discordance between FFR ≤ 0.8 and iFR ≤ 0.89 was observed in 22 vessels (21.0%) of 21 patients. In multivariate logistic analysis, LAD (OR 3.55; 95%CI 1.20-11.71; p = 0.0217) and lumen volume/myocardial weight (L/M) ratio (OR 0.93; 0.86-0.99, p = 0.0290) were significant predictors for FFR-positive findings. For iFR-positive findings, LAD (OR 3.86; 95%CI 1.12-13.31; p = 0.0236) was only significant predictor. In FFR ≤ 0.8 and iFR > 0.89 group (15 vessels, 14.3%), positive remodeling (PR) (OR 5.03, 95%CI 1.23-20.48, p = 0.0205) was significant predictor. In FFR > 0.8 and iFR ≤ 0.89 group (7 vessels, 6.7%), there were no significant predictors. CONCLUSION: On CCTA characteristics, a relevant predictor for FFR-positive findings included low L/M ratio. PR was significant predictor in FFR-positive, iFR-negative patients among those with discordance between the FFR and iFR.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Placa Aterosclerótica/diagnóstico , Idoso , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Placa Aterosclerótica/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
3.
J Neurosci Res ; 98(5): 936-949, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32026517

RESUMO

Neurocognitive and psychiatric disorders have significant consequences for quality of life in patients with Parkinson's disease (PD). In the current study, we evaluated microstructural white matter (WM) alterations associated with neurocognitive and psychiatric disorders in PD using neurite orientation dispersion and density imaging (NODDI) and linked independent component analysis (LICA). The indices of NODDI were compared between 20 and 19 patients with PD with and without neurocognitive and psychiatric disorders, respectively, and 25 healthy controls using tract-based spatial statistics and tract-of-interest analyses. LICA was applied to model inter-subject variability across measures. A widespread reduction in axonal density (indexed by intracellular volume fraction [ICVF]) was demonstrated in PD patients with and without neurocognitive and psychiatric disorders, as compared with healthy controls. Compared with patients without neurocognitive and psychiatric disorders, patients with neurocognitive and psychiatric disorders exhibited more extensive (posterior predominant) decreases in axonal density. Using LICA, ICVF demonstrated the highest contribution (59% weight) to the main effects of diagnosis that reflected widespread decreases in axonal density. These findings suggest that axonal loss is a major factor underlying WM pathology related to neurocognitive and psychiatric disorders in PD, whereas patients with neurocognitive and psychiatric disorders had broader axonal pathology, as compared with those without. LICA suggested that the ICVF can be used as a useful biomarker of microstructural changes in the WM related to neurocognitive and psychiatric disorders in PD.


Assuntos
Encéfalo/diagnóstico por imagem , Transtornos Cognitivos/diagnóstico por imagem , Transtornos Mentais/diagnóstico por imagem , Doença de Parkinson/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Idoso , Transtornos Cognitivos/complicações , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Transtornos Mentais/complicações , Pessoa de Meia-Idade , Doença de Parkinson/complicações
4.
Heart Vessels ; 35(2): 162-169, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31392411

RESUMO

The purpose of the study was to evaluate the optimal cut-off value of CT-Fractional Flow Reserve (CT-FFR) using fluid-structure interaction and how to adjust the CT-FFR's underestimation from a standpoint of minimize 1-year cardiac events. Subjects were 38 cases with 44 vessels in which stenosis of 30-90% was detected using one-rotation scanning by 320-row coronary CT angiography (CCTA) and invasive FFR (i-FFR) was performed within subsequent 90 days. CT-FFR was calculated using on-site from the multiple cardiac phases. A hypothetical 1-year cardiac event incidence was estimated using previous evidences when revascularization was decided based on CT-FFR. We assessed the optimal cut-off value of CT-FFR and how to correct the CT-FFR to minimize hypothetical cardiac events under four different disease prevalence (20%, 25%, 30%, 35%, and 40%). A total of 16 vessels had i-FFR ≤ 0.8. On per-patient basis, the sensitivity, specificity, positive predict value, negative predict value, and diagnostic accuracy of CT-FFR â‰¦ 0.8 vs CCTA > 50% to detect functional stenosis defined as invasive FFR â‰¦ 0.80 were 93.3% vs 73.3%, 73.9% vs 26.1%, 70.0% vs 39.3%, 94.4% vs 60.0%, and 81.6% vs 44.7%, respectively. For minimize 1-year cardiac events, the optimal cut-off value for more than 30% of disease prevalence was 0.80. However, the optimal cut-off value for 20, 25, and 30% was 0.54 in any cases. After the adjustment of CT-FFR using a formula of 0.3X + 0.634 for CT-FFR < 0.7 to counteract its underestimation, the % reduction of the events for 20, 25, 30, 35, and 40% at a 0.80 cut-off were 19.0%, 15.6%, 12.6%, 10.0%, and 7.7% respectively. It was reasonable to support that the optimal cut-off value was 0.80 in disease prevalence of more than 30% for minimize 1-year cardiac events. However, underestimation should be adjusted to reduce cardiac events, especially when disease prevalence is low.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Idoso , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/epidemiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Fatores de Tempo , Tóquio/epidemiologia
5.
Neuroradiology ; 61(12): 1343-1353, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31209529

RESUMO

PURPOSE: Autism spectrum disorder (ASD) is related to impairment in various white matter (WM) pathways. Utility of the recently developed two-compartment model of diffusion kurtosis imaging (DKI) to analyse axial diffusivity of WM is restricted by several limitations. The present study aims to validate the utility of model-free DKI in the evaluation of WM alterations in ASD and analyse the potential relationship between DKI-evident WM alterations and personality scales. METHODS: Overall, 15 participants with ASD and 15 neurotypical (NT) controls were scanned on a 3 T magnetic resonance (MR) scanner, and scores for autism quotient (AQ), systemising quotient (SQ) and empathising quotient (EQ) were obtained for both groups. Multishell diffusion-weighted MR data were acquired using two b-values (1000 and 2000 s/mm2). Differences in mean kurtosis (MK), radial kurtosis (RK) and axial kurtosis (AK) between the groups were evaluated using tract-based spatial statistics (TBSS). Finally, the relationships between the kurtosis indices and personality quotients were examined. RESULTS: The ASD group demonstrated significantly lower AK in the body and splenium of corpus callosum than the NT group; however, no other significant differences were identified. Negative correlations were found between AK and AQ or SQ, predominantly in WM areas related to social-emotional processing such as uncinate fasciculus, inferior fronto-occipital fasciculus, and inferior and superior longitudinal fasciculi. CONCLUSIONS: Model-free DKI and its indices may represent a novel, objective method for detecting the disease severity and WM alterations in patients with ASD.


Assuntos
Transtorno do Espectro Autista/patologia , Imagem de Tensor de Difusão , Leucoaraiose/patologia , Substância Branca/patologia , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Masculino
6.
BMC Med Inform Decis Mak ; 19(1): 226, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31730484

RESUMO

BACKGROUND: Electronic medical records (EMR) contain numerical data important for clinical outcomes research, such as vital signs and cardiac ejection fractions (EF), which tend to be embedded in narrative clinical notes. In current practice, this data is often manually extracted for use in research studies. However, due to the large volume of notes in datasets, manually extracting numerical data often becomes infeasible. The objective of this study is to develop and validate a natural language processing (NLP) tool that can efficiently extract numerical clinical data from narrative notes. RESULTS: To validate the accuracy of the tool EXTraction of EMR Numerical Data (EXTEND), we developed a reference standard by manually extracting vital signs from 285 notes, EF values from 300 notes, glycated hemoglobin (HbA1C), and serum creatinine from 890 notes. For each parameter of interest, we calculated the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and F1 score of EXTEND using two metrics. (1) completion of data extraction, and (2) accuracy of data extraction compared to the actual values in the note verified by chart review. At the note level, extraction by EXTEND was considered correct only if it accurately detected and extracted all values of interest in a note. Using manually-annotated labels as the gold standard, the note-level accuracy of EXTEND in capturing the numerical vital sign values, EF, HbA1C and creatinine ranged from 0.88 to 0.95 for sensitivity, 0.95 to 1.0 for specificity, 0.95 to 1.0 for PPV, 0.89 to 0.99 for NPV, and 0.92 to 0.96 in F1 scores. Compared to the actual value level, the sensitivity, PPV, and F1 score of EXTEND ranged from 0.91 to 0.95, 0.95 to 1.0 and 0.95 to 0.96. CONCLUSIONS: EXTEND is an efficient, flexible tool that uses knowledge-based rules to extract clinical numerical parameters with high accuracy. By increasing dictionary terms and developing new rules, the usage of EXTEND can easily be expanded to extract additional numerical data important in clinical outcomes research.


Assuntos
Registros Eletrônicos de Saúde , Armazenamento e Recuperação da Informação , Processamento de Linguagem Natural , Algoritmos , Creatinina/sangue , Hemoglobinas Glicadas/metabolismo , Humanos , Sensibilidade e Especificidade , Volume Sistólico , Sinais Vitais
7.
Eur Radiol ; 28(4): 1600-1608, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29063252

RESUMO

PURPOSE: To test the hypothesis that "acute-period" lumbar MRI in non-elderly patients with low back pain is less frequently performed at clinics/hospitals with greater involvement of full-time radiologists in the imaging workflow. METHODS: In a national-level claims database, we identified 14,819 non-elderly patients (mean age: 38.7±8.0 years) who visited clinics/hospitals for low back pain in 2013-2015. We classified the clinics/hospitals into four groups based on the level of full-time radiologist involvement and MRI ownership, and compared the frequency of acute-period lumbar MRI using hierarchical logistic regression analysis. RESULTS: Patients visiting facilities without a full-time radiologist (n=2105) were significantly (p<0.001) more likely to undergo acute-period MRI than those visiting facilities with ≥1 radiologist partially managing imaging workflow (level-1, n=491) or ≥1 radiologist intensively involved in imaging workflow (level-2, n=1190) (15.7% vs. 6.9% and 7.3%; adjusted odds ratio of no-radiologist versus level-2: 2.93, p=0.018). No difference was observed between level-1 and level-2 involvement. CONCLUSIONS: Facilities with no full-time radiologist were more likely to perform acute-period MRI to assess for low back pain, while no difference was seen between facilities with varying levels of radiologist involvement in the imaging workflow. Radiologist involvement may contribute to optimal utilisation of medical imaging. KEY POINTS: • Lumbar MRI was more frequently performed at facilities without full-time radiologists. • Full-time radiologists may play an important role in appropriate utilisation of imaging. • Frequency of MRI was similar between moderate and intensive radiologist involvement.


Assuntos
Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Radiologistas/estatística & dados numéricos , Doença Aguda , Adolescente , Adulto , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Razão de Chances , Adulto Jovem
8.
J Comput Assist Tomogr ; 42(2): 256-262, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28937495

RESUMO

OBJECTIVE: The aim of this study was to evaluate the reproducibility of computed tomography (CT)-derived fractional flow reserve (FFR) determined on site by inexperienced observers using a postprocessing software based on structural and fluid analysis. METHODS: Using 21 coronary vessels in 7 patients who underwent 320-row coronary CT angiography and catheter-FFR, 2 independent inexperienced observers (A: a student radiation technologist; B: a nonmedical staff) determined the CT-FFR using a postprocessing software. After a 20-minute training session, both observers postprocessed all vessels and readjusted their settings after another training/feedback. These CT-FFRs were compared with values determined by an expert analyst. RESULTS: The mean processing times were 23 ± 4 minutes (automatic), 71 ± 5 minutes (observer A), and 57 ± 7 minutes (observer B) per patient. The initial correlations with expert data were r = 0.92 (observer A) and 0.73 (observer B) and increased to 0.83 for observer B after additional training. The final absolute difference with the expert data was 0.000 to 0.020. The correlation between catheter-FFR and expert CT-FFR was r = 0.76. CONCLUSIONS: The CT-derived FFR on-site postprocessing software showed good reproducibility for measurements by inexperienced observers.


Assuntos
Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
9.
Heart Vessels ; 33(5): 462-469, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29134268

RESUMO

The clinical significance of the transluminal attenuation gradient (TAG) has not been established. We evaluated the incremental diagnostic value of TAG by 320-row area detector computed tomography (320-ADCT). Subjects were 65 patients who underwent one-rotation scanning by 320-ADCT and invasive coronary angiography (ICA) within 3 months. TAG values were obtained for the major epicardial vessels 2 mm or more each in RCA, LAD and LCX using automatic analysis software. Moreover, TAG values that excluded calcified lesions in calculation of the regression line were also evaluated (excluded-TAG). In LAD, 21 intermediate lesions underwent functional flow reserve (FFR), and the incremental diagnostic value for functional stenosis was evaluated. The TAG values in the normal vessels were - 8.3 ± 5.0 (HU/cm) for the RCA (n = 32), - 23.3 ± 4.3 for the LAD (n = 9) and - 20.6 ± 10.0 for the LCX (n = 32). The RCA value was significantly higher (p < 0.001). The TAG values with stenosis degrees of ≤ 25%, 26-75%, ≥ 76% on ICA were - 8.3 ± 5.0 (n = 32) vs - 10.3 ± 7.2 (n = 25) vs - 10.0 ± 5.4 (n = 4) in the RCA, - 23.3 ± 4.3 (n = 9) vs - 21.0 ± 11.5 (n = 35) vs - 23.5 ± 15.3 (n = 10) in the LAD and - 21.1 ± 15.1 (n = 32) vs - 21.1 ± 15.1 (n = 16) vs - 17.7 ± 15.7 (n = 6) in the LCX, with no significant difference among the three groups. The excluded-TAG values also showed no significant difference. The area under the curve in the diagnosis of FFR < 0.8 in 21 LAD cases was 0.542 for CT only, 0.694 for CT + TAG, and 0.694 for CT + excluded-TAG. In single time-phase scanning by 320-ADCT, TAG does not offer an incremental diagnostic value.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Idoso , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos
10.
Neuroradiology ; 59(1): 89-98, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28035426

RESUMO

INTRODUCTION: The characteristics of dementia with Lewy bodies (DLB), Alzheimer's disease (AD) and amnestic mild cognitive impairment (a-MCI) overlap but require different treatments; therefore, it is important to differentiate these pathologies. Assessment of dopamine uptake in the striatum using dopamine transporter (DaT) single-photon emission computed tomography (SPECT) is the gold standard for diagnosing DLB; however, this modality is expensive, time consuming and involves radiation exposure. Degeneration of the substantia nigra nigrosome-1, which occurs in DLB, but not in AD/a-MCI, can be identified by 3T susceptibility-weighted imaging (SWI). Therefore, the aim of this retrospective observational study was to compare SWI with DaT-SPECT for differentiation of DLB from AD/a-MCI. METHODS: SWI data were acquired for patients with clinically diagnosed DLB (n = 29), AD (n = 18), a-MCI (n = 13) and healthy controls (n = 26). Images were analysed for nigrosome-1 degeneration. Diagnostic accuracy was evaluated for DLB, AD and a-MCI compared with striatal dopamine uptake using DaT-SPECT. RESULTS: SWI achieved 90% diagnostic accuracy (93% sensitivity, 87% specificity) for the detection of nigrosome-1 degeneration in DLB and not in AD/a-MCI as compared with 88.3% accuracy (93% sensitivity, 84% specificity) using DaT-SPECT. CONCLUSIONS: SWI nigrosome-1 evaluation was useful in differentiating DLB from AD/a-MCI, with high accuracy. This less invasive and less expensive method is a potential alternative to DaT-SPECT for the diagnosis of DLB.


Assuntos
Mapeamento Encefálico/métodos , Doença por Corpos de Lewy/diagnóstico por imagem , Doença por Corpos de Lewy/patologia , Imageamento por Ressonância Magnética/métodos , Substância Negra/diagnóstico por imagem , Substância Negra/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Radiology ; 279(1): 287-96, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26479161

RESUMO

PURPOSE: To evaluate the frequency and severity of pulmonary hemorrhage after transthoracic needle lung biopsy (TTLB) and assess possible factors associated with pulmonary hemorrhage. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. Records from 1113 patients who underwent 1175 TTLBs between January 2008 and April 2013 were retrospectively reviewed. Primary outcomes were pulmonary hemorrhage, documented hemoptysis, and bleeding complications necessitating intervention. Pulmonary hemorrhage was graded as follows: 0, none; 1, less than or equal to 2 cm around the needle; 2, more than 2 cm and sublobar; 3, at least lobar; and 4, hemothorax. Patient, technique, and lesion-related variables were evaluated as predictors of pulmonary hemorrhage. Patient-related variables included main pulmonary artery diameter (mPAD) at computed tomography (CT), pulmonary artery pressures at echocardiography and right-sided heart catheterization, medications, chronic lung disease, bleeding diathesis, and immunodeficiency. Technique- and lesion-related variables included needle gauge, number of passes, pleura-needle angle, lesion size and morphologic characteristics, and distance to pleura. Univariate analysis was performed with χ(2), Fisher exact, and Student t tests. RESULTS: Pulmonary hemorrhage occurred in 483 of the 1175 TTLBs (41.1%); hemoptysis was documented in 21 of the 1175 TTLBs (1.8%). Higher-grade hemorrhage (grade 2 or higher) occurred in 201 of the 1175 TTLBs (17.1%); five of the 1175 TTLBs (0.4%) necessitated hemorrhage-related admission. Higher-grade hemorrhage was more likely to occur with female sex (P = .001), older age (P = .003), emphysema (P = .004), coaxial technique (P = .025), nonsubpleural location (P < .001), lesion size of 3 cm or smaller (P < .001), and subsolid lesions (P = .028). Enlarged mPAD at CT (≥2.95 cm) was not significantly associated with higher-grade hemorrhage (P = .430). CONCLUSION: Pulmonary hemorrhage after TTLB is common but rarely requires intervention. An enlarged mPAD at CT may not be a risk factor for higher-grade hemorrhage.


Assuntos
Hemorragia/etiologia , Biópsia Guiada por Imagem/efeitos adversos , Pneumopatias/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemorragia/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Risco
12.
Radiology ; 281(3): 826-834, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27228331

RESUMO

Purpose To evaluate the variation among U.S. hospitals in overall use and yield of in-hospital computed tomographic (CT) pulmonary angiography (PA) in patients undergoing total hip replacement (THR) or total knee replacement (TKR) surgery. Materials and Methods Patients in the Premier Research Database who underwent elective TKR or THR between 2007 and 2011 were enrolled in this HIPAA-compliant, institutional review board-approved retrospective observational study. The informed consent requirement was waived. Hospitals were categorized into low, medium, and high tertiles of CT PA use to compare baseline patient- and hospital-level characteristics and pulmonary embolism (PE) positivity rates. To further investigate between-hospital variation in CT PA use, a hierarchical logistic regression model that included hospital-specific random effects and fixed patient- and hospital-level effects was used. The intraclass correlation coefficient (ICC) was used to measure the amount of variability in CT PA use attributable to between-hospital variation. Results The cohort included 205 198 patients discharged from 178 hospitals (median of 734.5 patients discharged per hospital; interquartile range, 316-1461 patients) with 3647 CT PA studies (1.8%). The crude frequency of CT PA scans among the hospitals ranged from 0% to 6.2% (median, 1.6%); more than 90% of the hospitals performed CT PA in less than 3% of their patients. The mean hospital-level PE positivity rate was 12.3% (median, 9.1%); there was no significant difference in PE positivity rate across low through high CT PA use tertiles (11.3%, 11.9%, 12.9%, P = .37). After adjustment for hospital- and patient-level factors, the remaining amount of interhospital variation was relatively low (ICC, 9.0%). Conclusion Limited interhospital variation in use and yield of in-hospital CT PA was observed among patients undergoing TKR or THR in the United States. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Idoso , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Estados Unidos
13.
Eur Radiol ; 26(8): 2567-77, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26515546

RESUMO

OBJECTIVES: We used neurite orientation dispersion and density imaging (NODDI) to quantify changes in the substantia nigra pars compacta (SNpc) and striatum in Parkinson disease (PD). METHODS: Diffusion-weighted magnetic resonance images were acquired from 58 PD patients and 36 age- and sex-matched controls. The intracellular volume fraction (Vic), orientation dispersion index (OD), and isotropic volume fraction (Viso) of the basal ganglia were compared between groups. Multivariate logistic regression analysis determined which diffusion parameters were independent predictors of PD. Receiver operating characteristic (ROC) analysis compared the diagnostic accuracies of the evaluated indices. Pearson coefficient analysis correlated each diffusional parameter with disease severity. RESULTS: Vic in the contralateral SNpc and putamen were significantly lower in PD patients than in healthy controls (P < 0.00058). Vic and OD in the SNpc and putamen showed significant negative correlations (P < 0.05) with disease severity. Multivariate logistic analysis revealed that Vic (P = 0.0000046) and mean diffusivity (P = 0.019) in the contralateral SNpc were the independent predictors of PD. In the ROC analysis, Vic in the contralateral SNpc showed the best diagnostic performance (mean cutoff, 0.62; sensitivity, 0.88; specificity, 0.83). CONCLUSION: NODDI is likely to be useful for diagnosing PD and assessing its progression. KEY POINTS: • Neurite orientation dispersion and density imaging (NODDI) is a new diffusion MRI technique • NODDI estimates neurite microstructure more specifically than diffusion tensor imaging • By using NODDI, nigrostriatal alterations in PD can be evaluated in vivo • NOODI is useful for diagnosing PD and assessing its disease progression.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Neuritos/patologia , Doença de Parkinson/diagnóstico , Substância Negra/diagnóstico por imagem , Idoso , Gânglios da Base/diagnóstico por imagem , Feminino , Humanos , Masculino
14.
Radiographics ; 36(1): 176-91, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26761536

RESUMO

The migration of imaging reports to electronic medical record systems holds great potential in terms of advancing radiology research and practice by leveraging the large volume of data continuously being updated, integrated, and shared. However, there are significant challenges as well, largely due to the heterogeneity of how these data are formatted. Indeed, although there is movement toward structured reporting in radiology (ie, hierarchically itemized reporting with use of standardized terminology), the majority of radiology reports remain unstructured and use free-form language. To effectively "mine" these large datasets for hypothesis testing, a robust strategy for extracting the necessary information is needed. Manual extraction of information is a time-consuming and often unmanageable task. "Intelligent" search engines that instead rely on natural language processing (NLP), a computer-based approach to analyzing free-form text or speech, can be used to automate this data mining task. The overall goal of NLP is to translate natural human language into a structured format (ie, a fixed collection of elements), each with a standardized set of choices for its value, that is easily manipulated by computer programs to (among other things) order into subcategories or query for the presence or absence of a finding. The authors review the fundamentals of NLP and describe various techniques that constitute NLP in radiology, along with some key applications.


Assuntos
Pesquisa Biomédica/organização & administração , Mineração de Dados/métodos , Registros Eletrônicos de Saúde/organização & administração , Processamento de Linguagem Natural , Radiologia/organização & administração , Vocabulário Controlado , Humanos , Aprendizado de Máquina , Reconhecimento Automatizado de Padrão/métodos
15.
J Comput Assist Tomogr ; 40(3): 387-92, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26938697

RESUMO

OBJECTIVE: The aim of this study was to prospectively test the performance and potential for clinical integration of software that automatically calculates the right-to-left ventricular (RV/LV) diameter ratio from computed tomography pulmonary angiography images. METHODS: Using 115 computed tomography pulmonary angiography images that were positive for acute pulmonary embolism, we prospectively evaluated RV/LV ratio measurements that were obtained as follows: (1) completely manual measurement (reference standard), (2) completely automated measurement using the software, and (3 and 4) using a customized software interface that allowed 2 independent radiologists to manually adjust the automatically positioned calipers. RESULTS: Automated measurements underestimated (P < 0.001) the reference standard (1.09 [0.25] vs1.03 [0.35]). With manual correction of the automatically positioned calipers, the mean ratio became closer to the reference standard (1.06 [0.29] by read 1 and 1.07 [0.30] by read 2), and the correlation improved (r = 0.675 to 0.872 and 0.887). The mean time required for manual adjustment (37 [20] seconds) was significantly less than the time required to perform measurements entirely manually (100 [23] seconds). CONCLUSIONS: Automated CT RV/LV diameter ratio software shows promise for integration into the clinical workflow for patients with acute pulmonary embolism.


Assuntos
Angiografia por Tomografia Computadorizada , Ventrículos do Coração/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Software , Algoritmos , Ventrículos do Coração/anatomia & histologia , Humanos , Aprendizado de Máquina , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Embolia Pulmonar/patologia , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
AJR Am J Roentgenol ; 204(1): W27-36, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539270

RESUMO

OBJECTIVE. The purpose of this study was to comprehensively study estimated radiation doses for subjects included in the main analysis of the Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography (CORE320) study ( ClinicalTrials.gov identifier NCT00934037), a clinical trial comparing combined CT angiography (CTA) and perfusion CT with the reference standard catheter angiography plus myocardial perfusion SPECT. SUBJECTS AND METHODS. Prospectively acquired data on 381 CORE320 subjects were analyzed in four groups of testing related to radiation exposure. Radiation dose estimates were compared between modalities for combined CTA and perfusion CT with respect to covariates known to influence radiation exposure and for the main clinical outcomes defined by the trial. The final analysis assessed variations in radiation dose with respect to several factors inherent to the trial. RESULTS. The mean radiation dose estimate for the combined CTA and perfusion CT protocol (8.63 mSv) was significantly (p < 0.0001 for both) less than the average dose delivered from SPECT (10.48 mSv) and the average dose from diagnostic catheter angiography (11.63 mSv). There was no significant difference in estimated CTA-perfusion CT radiation dose for subjects who had false-positive or false-negative results in the CORE320 main analyses in a comparison with subjects for whom the CTA-perfusion CT findings were in accordance with the reference standard SPECT plus catheter angiographic findings. CONCLUSION. Radiation dose estimates from CORE320 support clinical implementation of a combined CT protocol for assessing coronary anatomy and myocardial perfusion.


Assuntos
Absorção de Radiação , Angiografia Coronária/estatística & dados numéricos , Estenose Coronária/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Contagem Corporal Total/estatística & dados numéricos , Idoso , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Radiographics ; 35(7): 1965-88, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26562233

RESUMO

While use of advanced visualization in radiology is instrumental in diagnosis and communication with referring clinicians, there is an unmet need to render Digital Imaging and Communications in Medicine (DICOM) images as three-dimensional (3D) printed models capable of providing both tactile feedback and tangible depth information about anatomic and pathologic states. Three-dimensional printed models, already entrenched in the nonmedical sciences, are rapidly being embraced in medicine as well as in the lay community. Incorporating 3D printing from images generated and interpreted by radiologists presents particular challenges, including training, materials and equipment, and guidelines. The overall costs of a 3D printing laboratory must be balanced by the clinical benefits. It is expected that the number of 3D-printed models generated from DICOM images for planning interventions and fabricating implants will grow exponentially. Radiologists should at a minimum be familiar with 3D printing as it relates to their field, including types of 3D printing technologies and materials used to create 3D-printed anatomic models, published applications of models to date, and clinical benefits in radiology. Online supplemental material is available for this article.


Assuntos
Modelos Anatômicos , Impressão Tridimensional , Radiologia/métodos , Recursos Audiovisuais , Humanos , Imagens de Fantasmas , Impressão Tridimensional/economia , Impressão Tridimensional/instrumentação , Impressão Tridimensional/tendências , Desenho de Prótese , Resinas Sintéticas , Reologia , Software , Cirurgia Assistida por Computador , Engenharia Tecidual/métodos , Tomografia Computadorizada por Raios X
18.
Radiology ; 271(1): 282-90, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24475801

RESUMO

PURPOSE: To test the hypothesis that type II endoleak cavity volume (ECV) and endoleak cavity diameter (ECD) measurements are accurate indicators of aneurysm sac volume (ASV) enlargement in patients who undergo endovascular aneurysm repair (EVAR) in the abdominal aorta. MATERIALS AND METHODS: The institutional review board approved and waived the need to obtain patient consent for this HIPAA-compliant retrospective study. In 72 patients who underwent EVAR, 160 computed tomographic (CT) angiography studies revealed type II endoleaks. Corresponding to these 160 CT angiography studies, 113 CT follow-up studies (in 52 patients) were available and were included in the analysis. ECV measurements were obtained by two observers in consensus by using arterial enhanced phase (ECVAEP) and 70-second delayed enhanced phase (ECVDEP) CT images. The ECVDEP was also normalized as the ECV/ASV ratio. Maximum (ECDM) and transverse (ECDT) ECDs were determined from delayed enhanced phase images. The outcome was determined as interval increase (>2%) in ASV versus stable or decreasing (≤2%) ASV. Receiver operating characteristic (ROC) analysis was used to compare the accuracy of type II ECV and ECD measurements in indicating interval increase in ASV. RESULTS: In 56 (49.5%) of 113 CT studies in type II endoleaks, there was an interval increase in ASV. The accuracies of ECVDEP (area under the ROC curve [AUC], 0.85) and normalized ECVDEP (AUC, 0.86) were superior to the accuracies of ECDM (AUC, 0.73), ECDT (AUC, 0.73), and ECVAEP (AUC, 0.66). At ROC curve analysis, the sensitivity, specificity, and positive and negative predictive values for type II endoleak cavities with an ECVDEP of less than 0.5 mL for showing no future sac volume enlargement were 33% (19 of 57), 100% (56 of 56), 100% (19 of 19), and 60% (56 of 94), respectively. CONCLUSION: With use of the delayed enhanced phase of CT angiography, ECV measurement is an accurate indicator of aneurysm sac enlargement.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Endoleak/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Aneurisma da Aorta Abdominal/patologia , Implante de Prótese Vascular , Endoleak/classificação , Feminino , Humanos , Imageamento Tridimensional , Masculino , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Resultado do Tratamento
19.
J Biomed Inform ; 52: 386-93, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25117751

RESUMO

In this paper we describe an efficient tool based on natural language processing for classifying the detail state of pulmonary embolism (PE) recorded in CT pulmonary angiography reports. The classification tasks include: PE present vs. absent, acute PE vs. others, central PE vs. others, and subsegmental PE vs. others. Statistical learning algorithms were trained with features extracted using the NLP tool and gold standard labels obtained via chart review from two radiologists. The areas under the receiver operating characteristic curves (AUC) for the four tasks were 0.998, 0.945, 0.987, and 0.986, respectively. We compared our classifiers with bag-of-words Naive Bayes classifiers, a standard text mining technology, which gave AUC 0.942, 0.765, 0.766, and 0.712, respectively.


Assuntos
Angiografia/métodos , Processamento de Linguagem Natural , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Curva ROC
20.
J Cardiol ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38876399

RESUMO

BACKGROUND: On-site computed tomography-derived fractional flow reserve (CT-FFR) is a feasible method for examining lesion-specific ischemia, and plaque analysis of coronary CT angiography (CCTA) is useful for predicting future cardiac events. However, their utility and association on a per-vessel level remain unclear. METHODS: We analyzed vessels showing 50-90 % stenosis on CCTA where planned revascularization was not performed after CCTA within 90 days. Relevant features, including CT-FFR and the plaque burden [necrotic core to the total plaque volume (% necrotic core), and non-calcified plaque (NCP) to vessel volume (% NCP)] using a novel algorithm for analyzing plaque to predict vessel-oriented composite outcomes (VOCO), including cardiac death, non-fatal myocardial infarction, and unplanned vessel-related revascularization, were assessed. RESULTS: In 256 patients (68.7 ±â€¯9.4 years; 73.8 % male) with 354 vessels (10.5 % CT-FFR ≤ 0.80), VOCO occurred in 24 vessels (6.8 %) during a median follow-up of 3.6 years. Multivariable Cox analysis revealed CT-FFR ≤ 0.80 had the pronounced impact on VOCO, and moreover, higher % necrotic core and % NCP were independently associated with VOCO [adjusted hazard ratio 3.43 (95 % confidence interval 1.42-8.29) and 4.05 (1.19-13.71), respectively], especially for vessels with CT-FFR > 0.80. CONCLUSIONS: In vessels without planned revascularization, per-vessel CT-FFR ≤ 0.80 was the notable predictor of future cardiac events. Additionally, necrotic core volume and NCP were identified as independent predictors along with CT-FFR.

SELEÇÃO DE REFERÊNCIAS