Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Am Heart J ; 275: 128-137, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Catheter Cardiovasc Interv ; 100(1): 122-130, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35485723

RESUMO

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis. METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints. RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs). CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
4.
J Extra Corpor Technol ; 49(3): 201-205, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28979045

RESUMO

A limit of peripheral veno-arterial Extracorporeal Membrane Oxigenator (VA-ECMO) is the inadequate unloading of the left ventricle. The increase of end-diastolic pressure reduces the possibility of a recovery and may cause severe pulmonary edema. In this study, we evaluate our results after implantation of VA-ECMO and Transapical Left Ventricular Vent (TLVV) as a bridge to recovery, heart transplantation or long-term left ventricular assit devices (LVAD). From 2011 to 2014, 24 consecutive patients with profound cardiogenic shock were supported by peripheral VA-ECMO as bridge to decision. In all cases, TLVV was implanted after a mean period of 12.2 ± 3.4 hours through a left mini-thoracotomy and connected to the venous inflow line of the VA-ECMO. Thirty-day mortality was 37.5% (9/24). In all patients, hemodynamics improved after TLVV implantation with an increased cardiac output, mixed venous saturation and a significant reduced heart filling pressures (p < .05). Recovery of the cardiac function was observed in 11 patients (11/24; 45.8%). Three patients were transplanted (3/24; 12.5%) and three patients (3/24; 12.5%) underwent LVAD implantation as destination therapy, all these patients were discharged from the hospital in good clinical conditions. In these critical patients, systematic TLVV improved hemodynamic seemed to provide better in hospital survival and chance of recovery, compared to VA-ECMO results in the treatment of cardiogenic shock reported in the literature . TLVV is a viable alternative to standard VA-ECMO to identify the appropriate long-term strategy (heart transplantation or long-term VAD) reducing the risk of treatment failure. A larger and multicenter experience is mandatory to validate these hypothesis.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Ventrículos do Coração/fisiopatologia , Choque Cardiogênico/terapia , Adolescente , Adulto , Suporte Vital Cardíaco Avançado , Idoso , Feminino , Coração Auxiliar , Máquina Coração-Pulmão , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Oxigenadores de Membrana , Estudos Retrospectivos , Adulto Jovem
8.
J Heart Valve Dis ; 23(2): 216-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25076553

RESUMO

Transcatheter aortic valve implantation (TAVI) is sometimes associated with severe complications due to the unpredictability of such closed-chest procedures. Reported complications include atrioventricular blocks, vascular complications, aortic root rupture, aorto-right ventricular fistulas, and aortic dissections. Herein is presented the case of an 88-year-old female with a late atrioventricular septal defect that developed after TAVI.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/patologia , Valvuloplastia com Balão/efeitos adversos , Calcinose/terapia , Cateterismo Cardíaco/efeitos adversos , Traumatismos Cardíacos/etiologia , Septos Cardíacos/lesões , Implante de Prótese de Valva Cardíaca/efeitos adversos , Doença Iatrogênica , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico , Calcinose/diagnóstico , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Evolução Fatal , Feminino , Traumatismos Cardíacos/diagnóstico , Septos Cardíacos/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Fatores de Tempo , Tomografia Computadorizada por Raios X
9.
JACC Case Rep ; 29(7): 102273, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38645293

RESUMO

An 84-year-old man presented with dyspnea at rest due to severe mitral regurgitation. He first underwent transventricular mitral valve repair with the Harpoon system, which relapsed owing to rupture of neochords. He was definitively treated with transcatheter mitral valve implantation of the Tendyne system 8 months later.

10.
J Am Heart Assoc ; 13(7): e032955, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533944

RESUMO

BACKGROUND: Dialysis is a rare but serious complication after transcatheter aortic valve replacement. We analyzed the large multicenter TRITAVI (transfusion requirements in transcatheter aortic valve implantation) registry in order to develop and validate a clinical score assessing this risk. METHODS AND RESULTS: A total of 10 071 consecutive patients were enrolled in 19 European centers. Patients were randomly assigned (2:1) to a derivation and validation cohort. Two scores were developed, 1 including only preprocedural variables (TRITAVIpre) and 1 also including procedural variables (TRITAVIpost). In the 6714 patients of the derivation cohort (age 82±6 years, 48% men), preprocedural factors independently associated with dialysis and included in the TRITAVIpre score were male sex, diabetes, prior coronary artery bypass graft, anemia, nonfemoral access, and creatinine clearance <30 mL/min per m2. Additional independent predictors among procedural features were volume of contrast, need for transfusion, and major vascular complications. Both scores showed a good discrimination power for identifying risk for dialysis with C-statistic 0.78 for TRITAVIpre and C-statistic 0.88 for TRITAVIpost score. Need for dialysis increased from the lowest to the highest of 3 risk score groups (from 0.3% to 3.9% for TRITAVIpre score and from 0.1% to 6.2% for TRITAVIpost score). Analysis of the 3357 patients of the validation cohort (age 82±7 years, 48% men) confirmed the good discrimination power of both scores (C-statistic 0.80 for TRITAVIpre and 0.81 for TRITAVIpost score). Need for dialysis was associated with a significant increase in 1-year mortality (from 6.9% to 54.4%; P=0.0001). CONCLUSIONS: A simple preprocedural clinical score can help predict the risk of dialysis after transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Diálise Renal , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Multicêntricos como Assunto
11.
J Comput Assist Tomogr ; 37(3): 419-25, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23674015

RESUMO

OBJECTIVE: To assess the accuracy of a semiautomated 3-dimensional (3D) computed tomographic angiography software in the evaluation of lower limb stenoses compared to reader evaluation, using digital subtraction angiography (DSA) as standard of reference. MATERIALS AND METHODS: Forty patients with peripheral vascular occlusive disease underwent both DSA and computed tomographic angiography. The vascular tree was divided into 6 segments from distal aorta to popliteal artery. Each district was evaluated for significant stenosis by one experienced vascular radiologist (on axial as well as 3D images) and by a semiautomated 3D software analysis, independently. Evaluation of the vessel evaluation was then repeated by a poorly experienced radiologist twice, first without 3D software analysis and then supported by 3D software analysis. RESULTS: Both experienced radiologist and automated evaluations obtained high statistical results when compared to DSA. The analysis by poorly experienced radiologist obtained lower statistical results, which significantly improved when supported by 3D software analysis. CONCLUSIONS: Three-dimensional analysis software should be feasible to identify significant vascular stenoses and may help a poorly experienced radiologist to significantly improve diagnostic accuracy.


Assuntos
Angiografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Software
12.
Echocardiography ; 30(3): 250-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23190425

RESUMO

OBJECTIVE: This study aims to assess changes in mitral regurgitation (MR) severity after transcatheter aortic valve implantation (TAVI). BACKGROUND: Existing data on MR after TAVI are contradictory. METHODS: Thirty-five patients with MR graded ≥ 2+ were followed after undergoing TAVI with either the Edwards Sapien or CoreValve device. Echocardiography was performed the week before and 3 months after the procedure. MR was graded on a scale of 0 to 4+, classified as organic or functional, and the effective regurgitant orifice area (EROA) and MR index were calculated. RESULTS: At baseline, MR was graded 4+ in 4 (11.4%) patients, 3+  in 10 (28.6%), and 2+ in 21 (60%). At follow-up, MR was graded at 3+ in 4 (11.4%) patients, 2+ in 8 (22.9%), and 1+ in 19 (54.3%); 4 (11.4%) exhibited no MR. EROA (24.4 ± 11.5 mm(2) pre-TAVI vs. 11.2 ± 10.3 mm(2) post-TAVI, P < 0.001) and MR index (1.9 ± 0.3 pre-TAVI vs. 1.3 ± 0.7 post-TAVI, P < 0.001) were reduced with TAVI, independent of the etiology. MR decreased by at least 1 grade in 28 (80%) patients, with a reduction ≥2 grades in 10 (28.6%) patients; no patient showed a worsened condition. Subgroup analyses showed that the reduction in MR was significant in patients treated with the Edwards Sapien device but not in patients treated with the CoreValve device. CONCLUSIONS: This multiparametric echocardiographic evaluation showed that MR improved significantly after TAVI and that this result may be related to the type of valve implanted.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
13.
Heart Lung Circ ; 22(12): 1036-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23726665

RESUMO

A 60 year-old female underwent tricuspid valve replacement in 2002. Post-operative recovery was complicated by severe post-pericardiotomy-syndrome. Seven years later she underwent transcatheter valve-in-valve implantation through the right jugular vein because of early prosthesis deterioration. Moreover intra-operative transoesophageal echocardiography showed an important right-to-left shunt through the patent foramen ovale that immediately disappeared after the deployment of a 29-mm Sapien-XT. The patient had an immediate and dramatic improvement in day-by-day activities. This case shows that tricuspid valve deterioration can be safely and successfully treated through this approach.


Assuntos
Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca , Veias Jugulares , Insuficiência da Valva Tricúspide , Valva Tricúspide , Feminino , Humanos , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
14.
JACC Cardiovasc Interv ; 16(9): 1081-1091, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37164607

RESUMO

BACKGROUND: Long-term right ventricular pacing (VP) has been related to negative left ventricular remodeling and heart failure (HF), but there is a lack of evidence regarding the prognostic impact on transcatheter aortic valve replacement (TAVR) patients. OBJECTIVES: The aim of the PACE-TAVI registry is to evaluate the association of high percentage of VP with adverse outcomes in patients with pacemaker implantation after TAVR. METHODS: PACE-TAVI is an international multicenter registry of all consecutive TAVR patients who underwent permanent pacemaker implantation for conduction disturbances in the first 30 days after the procedure. Patients were divided into 2 subgroups according to the percentage of VP (<40% vs ≥40%) at pacemaker interrogation. The primary endpoint was the composite of cardiovascular mortality or hospitalization for HF. RESULTS: A total of 377 patients were enrolled, 158 with VP <40% and 219 with VP ≥40%. After multivariable adjustment, VP ≥40% was associated with a higher incidence of the primary endpoint (HR: 2.76; 95% CI: 1.39-5.51; P = 0.004), first HF hospitalization (HR: 3.37; 95% CI: 1.50-7.54; P = 0.003), and cardiovascular death (HR: 3.77; 95% CI: 1.02-13.88; P = 0.04), while the incidence of all-cause death was not significantly different (HR: 2.17; 95% CI: 0.80-5.90; P = 0.13). Patients with VP ≥ 40% showed a higher New York Heart Association functional class both at 1 year (P = 0.009) and at last available follow-up (P = 0.04) and a nonsignificant reduction of left ventricular ejection fraction (P = 0.18) on 1-year echocardiography, while patients with VP <40% showed significant improvement (P = 0.009). CONCLUSIONS: In TAVR patients undergoing permanent pacemaker implantation, a high percentage of right VP at follow-up is associated with an increased risk for cardiovascular death and HF hospitalization. These findings suggest the opportunity to minimize right VP through dedicated algorithms in post-TAVR patients without complete atrioventricular block and to evaluate a more physiological VP modality in patients with persistent complete atrioventricular block.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Volume Sistólico , Estimulação Cardíaca Artificial/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Função Ventricular Esquerda , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
15.
J Invasive Cardiol ; 34(2): E104-E113, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34995208

RESUMO

AIMS: To evaluate the impact of systematic predilation with balloon aortic valvuloplasty (BAV) on transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We performed a systematic meta-analysis investigating patients undergoing TAVI with systematic BAV vs no BAV in RCT or in adjusted studies. Device success was the primary endpoint, while all-cause mortality, 30-day moderate/severe aortic regurgitation (AR), stroke, permanent pacemaker implantation (PPI) and acute kidney injury (AKI) were the secondary endpoints. Subanalysis according to design of the study (RCT and adjusted analysis) and to the type of valve (balloon-expandable [BE] vs self-expanding [SE]) were conducted. We obtained data from 15 studies, comprising 16,408 patients: 10,364 undergoing BAV prior to TAVI and 6,044 in which direct TAVI has been performed. At 30-day follow-up, BAV did not improve the rate of device success in the overall population (OR, 1.09; 95% CI, 0.90-1.31), both in SE (OR, 0.93; 95% CI, 0.60-1.45) and in BE (OR, 1.16; 95% CI, 0.88-1.52) valves. Between BAV and direct TAVI, no differences in secondary outcomes were observed neither in overall population nor according to valve type between BAV and direct TAVI strategies. All endpoints results were consistent between RCTs and adjusted studies except for postdilation rate that did not differ in observational studies (OR, 0.70; 95% CI, 0.47-1.04), while it was lower in BAV when only RCTs were included in the analysis (OR, 0.48; 95% CI, 0.24-0.97). CONCLUSIONS: Direct TAVI is feasible and safe compared to predilation approach with similar device success rates and clinical outcomes. Direct TAVI could represent a first-choice approach in contemporary TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/métodos , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
J Cardiovasc Comput Tomogr ; 16(3): 207-214, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34896066

RESUMO

BACKGROUND: The adoption of Computed tomography (CT)-defined sarcopenia to risk stratify transcatheter aortic valve implantation (TAVI) candidates remains limited by a lack of both standardized definition and evidence of independent value over currently adopted mortality prediction tools. METHODS: 391 consecutive TAVI patients with pre-procedural CT scan were included (81 â€‹± â€‹6 years, 57.5% male, STS-PROM score 4.4 â€‹± â€‹3.6%) and abdominal muscle retrospectively quantified. The two definitions of radiologic sarcopenia previously adopted in TAVI studies were compared (psoas muscle area [PMA] at the L4 vertebra level: "PMA-sarcopenia"; indexed skeletal muscle area at the L3 vertebra level: "SMI-sarcopenia"). The primary endpoint was longer available-term all-cause mortality. Secondary endpoints were Valve Academic Research Consortium-2-defined in-hospital and 30-day outcomes. RESULTS: SMI- and PMA-sarcopenia were present in 192 (49.1%) and 117 (29.9%) patients, respectively. After a median of 24 (12-30) months follow-up, 83 (21.2%) patients died. PMA-(adj-HR 1.81, 95%CI 1.12-2.93, p â€‹= â€‹0.015), but not SMI-sarcopenia (adj-HR 1.23, 95%CI 0.76-2.00, p â€‹= â€‹0.391), was associated with all-cause mortality independently of age, sex and in-study outcome predictors (atrial fibrillation, hemoglobin, history of peripheral artery disease, cancer and subcutaneous adipose tissue). PMA-defined sarcopenia provided additive prognostic value over current post-TAVI mortality risk estimators including STS-PROM (p â€‹= â€‹0.001), Euroscore II (p â€‹= â€‹0.025), Charlson index (p â€‹= â€‹0.025) and TAVI2-score (p â€‹= â€‹0.020). Device success, early safety, clinical efficacy and 30-day all-cause death were unaffected by sarcopenia status regardless of definition. CONCLUSIONS: PMA-sarcopenia (but not SMI-sarcopenia) is predictive of 2 year mortality among TAVI patients. The prognostic information provided by PMA-sarcopenia is independent of the tools currently adopted to predict post-TAVI mortality in clinical practice.


Assuntos
Estenose da Valva Aórtica , Sarcopenia , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Músculos Psoas/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Sarcopenia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
17.
Heart Lung Circ ; 20(2): 127-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21093368

RESUMO

There is no standardised approach for cardioplegia administration during ascending aorta replacement (AAR) and the techniques used so far are quite variable and show important limitations. In order to overcome these limitations, we propose a simple and inexpensive technique using a Foley catheter for cardioplegia administration and bleeding control in case of AAR or aortic root surgery. The benefits of our technique are the technical simplicity and the low cost that makes this approach an ideal solution for cardioplegia administration in all cases of AAR.


Assuntos
Aorta/cirurgia , Soluções Cardioplégicas/administração & dosagem , Cateterismo/métodos , Catéteres , Parada Cardíaca Induzida/instrumentação , Parada Cardíaca Induzida/métodos , Animais , Hemorragia/prevenção & controle , Humanos
18.
Int J Cardiol ; 323: 208-212, 2021 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-32795480

RESUMO

INTRODUCTION: Accurate predictors of good clinical response after MitraClip implant in patients with heart failure (HF) are still lacking. Aim of this study was to investigate the role of regurgitant fraction >50% as a marker of disproportionate functional mitral regurgitation (FMR) in identifying best responders to Mitraclip. METHODS AND RESULTS: Data from 58 advanced HF patients (age 66 ±â€¯8 years, 81% males, 63% NYHA class IV, LV ejection fraction (EF) 25.5 ±â€¯5.5%) with disproportionate and proportionate FMR who underwent successful MitraClip implant were analyzed. After MitraClip all patient achieved mild (≤ 2+/4+) MR. During 12-month follow-up 18 patients (31%) had a major adverse cardiac event (MACE, i.e. cardiac death, urgent LVAD implant or heart transplantation, HF hospitalization). Disproportionate FMR (n = 48, 83%) was associated with a better clinical outcome (p = .003) while regurgitant volume and EROA were not. TAPSE ≤14 mm was associated with worse outcome (p = .018). At multivariable analysis only disproportionate MR and TAPSE ≤14 mm showed a significant association with MACE (p = .017 and p = .02, respectively). A reverse left ventricular remodeling (i.e., reduction on LV end-diastolic diameter and end-diastolic volume) was achieved only in the disproportionate FMR group. CONCLUSIONS: In conclusion, disproportionate FMR assessed by regurgitant fraction and RV dysfunction assessed by TAPSE may help the selection of HF patients candidates for MitraClip therapy.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Remodelação Ventricular
19.
Int J Cardiol ; 337: 90-98, 2021 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-33974961

RESUMO

INTRODUCTION: Recently, observational data have raised concerns about safety of selfexpandable (SE) compared to balloon-expandable (BE) valves in TAVI, although potentially limited by patient selection bias. METHODS: All Randomized Controlled Trials (RCTs) comparing BE vs. SE TAVI or/and vs. aortic valve replacement (AVR) were included and compared through Network Meta Analysis (NMA). All-cause and cardiovascular (CV) mortality were the primary endpoints, stroke, rates of permanent pacemaker implantation (PPI), moderate/severe paravalvular leak (PVL) and reintervention were the secondary endpoints. Results We obtained data from 11 RCTs, encompassing 9752 patients. After one and two years, no significant differences for allcause and CV mortality were observed. Compared to surgical bioprostheses, both BE and SE TAVI reduced the risk of acute kidney injury (OR 0.42; CI 95% 0.30-0.60 and OR 0.44; CI 95% 0.32-0.60), new-onset atrial fibrillation (OR 0.24; CI 95% 0.14-0.42 and OR 0.21; CI 95% 0.13-0.34) and major bleedings (OR 0.32; CI 95% 0.16-0.65 and OR 0.47; CI 95% 0.25-0.89). The BE prostheses reduced the risk of moderate/severe PVL at 30-day (OR 0.31; CI 95% 0.17-0.55) and of PPI both at 30-day (OR 0.51; CI 95% 0.33-0.79) and 1 year (OR 0.40; CI 95% 0.30-0.55) as compared to SE TAVI. Conclusions A TAVI strategy, independently from BE or SE prostheses, offers a midterm survival comparable to AVR. The BE prostheses are associated with a reduction of PPI and PVL compared to SE prostheses without any differences in all-cause and CV mortality during two years of follow up. PROSPERO ID CRD42020182407.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Metanálise em Rede , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Eur Heart J Qual Care Clin Outcomes ; 7(2): 143-153, 2021 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-33289527

RESUMO

AIMS: Permanent pacemaker implantation (PPI) may be required after transcatheter aortic valve implantation (TAVI). Evidence on PPI prediction has largely been gathered from high-risk patients receiving first-generation valve implants. We undertook a meta-analysis of the existing literature to examine the incidence and predictors of PPI after TAVI according to generation of valve, valve type, and surgical risk. METHODS AND RESULTS: We made a systematic literature search for studies with ≥100 patients reporting the incidence and adjusted predictors of PPI after TAVI. Subgroup analyses examined these features according to generation of valve, specific valve type, and surgical risk. We obtained data from 43 studies, encompassing 29 113 patients. Permanent pacemaker implantation rates ranged from 6.7% to 39.2% in individual studies with a pooled incidence of 19% (95% CI 16-21). Independent predictors for PPI were age [odds ratio (OR) 1.05, 95% confidence interval (CI) 1.01-1.09], left bundle branch block (LBBB) (OR 1.45, 95% CI 1.12-1.77), right bundle branch block (RBBB) (OR 4.15, 95% CI 3.23-4.88), implantation depth (OR 1.18, 95% CI 1.11-1.26), and self-expanding valve prosthesis (OR 2.99, 95% CI 1.39-4.59). Among subgroups analysed according to valve type, valve generation and surgical risk, independent predictors were RBBB, self-expanding valve type, first-degree atrioventricular block, and implantation depth. CONCLUSIONS: The principle independent predictors for PPI following TAVI are age, RBBB, LBBB, self-expanding valve type, and valve implantation depth. These characteristics should be taken into account in pre-procedural assessment to reduce PPI rates. PROSPERO ID CRD42020164043.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA