Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circ J ; 76(11): 2662-72, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22864277

RESUMO

BACKGROUND: While statin induces plaque regression, its effects, particularly with different doses on plaque virtual histology composition, remain unknown. METHODS AND RESULTS: In this prospective, randomized, double-blinded study, 40 consecutive statin-naive patients with stable angina requiring percutaneous coronary intervention (PCI) were randomized to 2 arms (20 patients each) receiving 6 months of atorvastatin 10 mg or 40 mg daily. The primary end-point was (VH-IVUS) changes from baseline to 6 months, as assessed by a core laboratory. Fifty-four VH-IVUS lesions were analyzed from the 10 mg group and 57 from the 40 mg group. Overall, plaque volume was reduced by 4.28% (-5.10±14.93 mm(3), P<0.001), absolute VH-IVUS fibrous volume by 10.54% (-4.87±10.74 mm(3), P<0.001), and relative percentage fibrous component by 3.29±7.84% (P<0.001), while relative percentage dense calcium increased by 1.50±3.08% (P<0.001), and necrotic core by 3.19±7.82% (P<0.001). Beneficial changes were more substantial in the higher dose (40 mg) group, with significantly more percentage plaque volume regression (-1.50±3.85% vs. 0.38±4.05% increase in the 10 mg group, P=0.014), less relative percentage necrotic core expansion (1.68±7.57% vs. 4.78±7.82% in the 10 mg group, P=0.037), and without occurrence of major adverse cardiac events (vs. 6 patients in the 10 mg group, P=0.020). CONCLUSIONS: In statin-naive patients requiring PCI, 6 months of atorvastatin induced a significant percentage of plaque volume reduction and substantial modification of VH-IVUS composition. In addition, these effects appeared to vary with different doses of atorvastatin, showing significantly better limitation of relative percentage necrotic core expansion at a higher dose.


Assuntos
Anticolesterolemiantes/administração & dosagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/terapia , Ácidos Heptanoicos/administração & dosagem , Placa Aterosclerótica/tratamento farmacológico , Placa Aterosclerótica/patologia , Pirróis/administração & dosagem , Idoso , Atorvastatina , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Fatores de Tempo
2.
Hong Kong Med J ; 18(5): 395-406, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23018067

RESUMO

OBJECTIVES. To evaluate attainment of low-density lipoprotein cholesterol goals among hypercholesterolaemic patients undergoing lipid-lowering drug treatment in Hong Kong and to identify potential determinants of treatment outcomes. DESIGN. Cross-sectional observational study. SETTING. A single site in Hong Kong, as part of the CEPHEUS Pan-Asian survey. PATIENTS. Subjects with hypercholesterolaemia aged 18 years or above, who had been on lipid-lowering drug treatment for at least 3 months with no dose adjustment for at least 6 weeks. RESULTS. A total of 561 such patients (mean age, 65.3; standard deviation, 9.7 years) were evaluated. Most had major cardiovascular risk factors; 534 (95.2%) of 561 patients had coronary heart disease and 534 (95.4%) of 560 patients had low-density lipoprotein cholesterol goals set at lower than 70 mg/dL. In all, 465 (82.9%) patients attained their respective low-density lipoprotein cholesterol goals. Among 75 patients who had coronary heart disease or equivalent risk, and multiple risk factors with a 10-year coronary heart disease risk of over 20%, 62 (82.7%) attained their respective low-density lipoprotein cholesterol goals. Significant predictors of low-density lipoprotein cholesterol goal attainment included the patient's baseline lipid profile (total cholesterol and low-density lipoprotein cholesterol levels), blood pressure, and drugs (statin/non-statin) used for treatment. CONCLUSIONS. Hypercholesterolaemic patients undergoing lipid-lowering drug treatment in the present Hong Kong study were able to achieve a very high attainment rate for the low-density lipoprotein cholesterol goal, despite the fact that most of them had major cardiovascular risk factors.


Assuntos
Doenças Cardiovasculares/prevenção & controle , LDL-Colesterol/sangue , Hipercolesterolemia/tratamento farmacológico , Hipolipemiantes/uso terapêutico , Adulto , Idoso , Pressão Sanguínea , Doenças Cardiovasculares/etiologia , Colesterol/sangue , Doença das Coronárias/etiologia , Doença das Coronárias/prevenção & controle , Estudos Transversais , Feminino , Hong Kong , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipercolesterolemia/complicações , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Resultado do Tratamento
3.
BMJ Open ; 11(1): e042587, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33402409

RESUMO

INTRODUCTION: Optimal antithrombotic strategy following transcatheter aortic valve replacement (TAVR) is still unknown. We hypothesised that the direct factor Xa inhibitor edoxaban can potentially prevent subclinical leaflet thrombosis and cerebral embolisation compared with conventional dual antiplatelet therapy (DAPT) in patients undergoing TAVR. METHODS AND ANALYSIS: The ADAPT-TAVR trial is an international, multicentre, randomised, open-label, superiority trial comparing edoxaban-based strategy and DAPT strategy in patients without an indication for oral anticoagulation who underwent successful TAVR. A total of 220 patients are randomised (1:1 ratio), 1-7 days after successful TAVR, to receive either edoxaban (60 mg daily or 30 mg daily if patients had dose-reduction criteria) or DAPT using aspirin (100 mg daily) plus clopidogrel (75 mg daily) for 6 months. The primary endpoint was an incidence of leaflet thrombosis on four-dimensional, volume-rendered cardiac CT imaging at 6 months post-TAVR. The key secondary endpoints were the number of new lesions and new lesion volume on brain diffusion-weighted MRI and the changes in neurological and neurocognitive function assessment between immediate post-TAVR and 6 months of study drug administration. Detailed clinical information on thromboembolic and bleeding events were also assessed. ETHICS AND DISSEMINATION: Ethic approval has been obtained from the Ethics Committee/Institutional Review Board of Asan Medical Center (approval number: 2017-1317) and this trial is also approved by National Institute of Food and Drug Safety Evaluation of Republic of Korea (approval number: 31511). Results of this study will be disseminated in scientific publication in reputed journals. TRIAL REGISTRATION NUMBER: NCT03284827.


Assuntos
Estenose da Valva Aórtica , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Piridinas , República da Coreia , Fatores de Risco , Tiazóis , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Circ Cardiovasc Interv ; 11(4): e006034, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29654119

RESUMO

BACKGROUND: Durable polymers used in drug-eluting stents are considered a potential cause of hypersensitivity inflammatory response adversely affecting stent healing. Using a sequential follow-up with optical coherence tomography, we compared the differences in healing profiles of 2 drug-eluting stents with a biodegradable or durable polymer. METHODS AND RESULTS: Sixty patients with multivessel disease were prospectively enrolled to receive both study stents, which were randomly assigned to 2 individual vessels, a Resolute Integrity zotarolimus-eluting stent with a durable BioLinx polymer and a BioMatrix NeoFlex Biolimus A9-eluting stent with a biodegradable polylactic acid polymer. Optical coherence tomography was performed at baseline, then in 5 randomly assigned monthly groups at 2 to 6 months, and at 9 months in all patients. The primary end point was the difference in optical coherence tomography strut coverage at 9 months. Key secondary end points included angiographic late lumen loss and composite major adverse cardiac events (cardiac death, myocardial infarction, target lesion revascularization, and definite or probable stent thrombosis) at 9 months. Resolute Integrity zotarolimus-eluting stent showed significantly better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent at 2 to 6 months (P<0.001) and less variance of percent coverage at 9 months, 99.7% (interquartile range, 99.1-100) versus 99.6% (interquartile range, 96.8-99.9; difference, 0.10; 95% confidence interval, 0.00-1.05; P<0.001). No significant difference was observed in major adverse cardiac events or angiographic end points. CONCLUSIONS: Despite having a durable polymer, Resolute Integrity zotarolimus-eluting stent exhibited better strut coverage than BioMatrix NeoFlex Biolimus A9-eluting stent having a biodegradable polymer; both showed similar antiproliferative efficacy. This novel, longitudinal, sequential optical coherence tomography protocol using each patient as own control could achieve conclusive results in small sample size. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01742507.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
5.
EuroIntervention ; 14(7): 780-788, 2018 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-29901444

RESUMO

AIMS: This study aimed to establish the early healing and neointimal transformation profile of the new polymer-free BioFreedom stent through sequential optical coherence tomography (OCT) within the first nine months following stent implantation. METHODS AND RESULTS: We randomly assigned 104 BFS recipients to one of five groups with angiography and OCT follow-up at 1, 2, 3, 4, or 5 months, together with another follow-up for all at nine months. The primary endpoint was the degree of OCT-detected strut coverage at nine months. From 1, 2, 3, 4, and 5 months, median neointimal strut coverage increased from 85.8, 87.0, 88.6, 96.8 to 97.1%, respectively, to 99.6% (IQR 98.2-99.9) at nine months. At nine months, median percent neointimal volume was 13.0% and angiographic late lumen loss was 0.21±0.30 mm. Major adverse cardiac events (MACE) were limited to one non-cardiac death, one non-ST-elevation myocardial infarction not related to BFS, and two target lesion revascularisations without stent thrombosis (MACE rate 4.0%). CONCLUSIONS: Neointimal strut coverage of the BFS was rapid and the BFS was shown to be clinically safe and effective.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Polímeros , Estudos Prospectivos , Desenho de Prótese , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-27418609

RESUMO

BACKGROUND: Current monotherapy drug-eluting stents are associated with impaired healing, neoatherosclerosis, and late stent thrombosis. The healing profile and neointimal transformation of the first dual-therapy endothelial progenitor cell-capturing sirolimus-eluting stent are unknown. METHODS AND RESULTS: In this prospective, single-center study, 61 patients treated with the Combo stent had optical coherence tomography at baseline, early follow-up (4 monthly groups in a 1:2:2:1 ratio from 2 to 5 months), 9 months, and 24 months. Optical coherence tomography early strut coverage increased from 77.1% to 92.5% to 92.7% to 94.9% between 2 and 5 months. At 9 months, the major adverse cardiac event rate was 1.64%, and angiographic in-stent late loss was 0.24 mm (0.08-0.40). The 36-month major adverse cardiac event rate was 3.3%. From 9 to 24 months, neointimal regression was confirmed by optical coherence tomography: neointimal thickness (median [first quartile and third quartile]), 0.14 mm (0.08 and 0.21) versus 0.12 mm (0.07 and 0.19), P<0.001; neointimal volume, 29.9 mm(3) (22.1 and 43.2) versus 26.2 mm(3) (19.6 and 35.8), P=0.003; and percent neointimal volume, 17.8% (12.2 and 21.2) versus 15.7% (11.2 and 19.4), P=0.01. No definite or probable late stent thrombosis was recorded. CONCLUSIONS: With additional endothelial progenitor cell-capturing technology, the Combo stent exhibits a unique late neointimal regression (from 9 to 24 months) that has not been reported in any drug-eluting stents, translating into good 36-month clinical results with minimal restenosis and no late stent thrombosis. This is the first study testing the concept of using a longitudinal sequential optical coherence tomography protocol to continuously document early healing profile and late neointimal transformation, predicting long-term outcomes of a new novel stent platform. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01274234, NCT01756807, and NCT02263313.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Células Progenitoras Endoteliais/transplante , Neointima , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Terapia Combinada , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA