Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Prostate ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39219052

RESUMO

BACKGROUND: Proliferating cell nuclear antigen (PCNA) is essential for DNA replication and repair, cell growth, and survival. PCNA also enhances androgen receptor (AR) signaling in prostate cancer (PC) cells. We identified a PCNA interaction protein (PIP) box at the N-terminal domain of AR and developed a small peptide PCNA inhibitor R9-AR-PIP containing AR PIP-box. We also identified a series of small molecule PCNA inhibitors (PCNA-Is) that bind directly to PCNA and interrupt PCNA functions. The present study investigated the effects of the PCNA inhibitors on the sensitivity of PC cells to X-ray radiation. METHODS: The effects of targeting PCNA on radio sensitivity of PC cells were investigated in four lines of castration-resistant PC (CRPC) cells with different AR expression statuses. The cells were treated with the PCNA inhibitors and X-ray radiation alone or in combination. The effects of the treatment on expression of AR target genes, DNA damage response, DNA damage, homologous recombination repair (HRR), and cytotoxicity were evaluated. RESULTS: We found that the androgen response element (ARE) occupancy of the DNA damage response gene PARP1 by AR is significantly attenuated by PCNA-I1S or R9-AR-PIP combined with X-ray radiation, while X-ray radiation alone does not enhance the ARE occupancy. PCNA-I1S or R9-AR-PIP alone significantly inhibits occupancy of the AR-occupied regions (AROR) in PRKDC and XRCC2 genes. R9-AR-PIP and PCNA-I1S inhibit expression of AR-Vs target gene cyclin A2 and show the additive effects with radiation in AR-positive CRPC cells. Targeting PCNA by PCNA-I1S and R9-AR-PIP downregulates expression of DNA damage response genes EXO1, Rad54L, Rad51, and/or PARP1 and shows the additive effects with radiation as compared with their respective controls in AR-positive CRPC LNCaP-AI, 22Rv1, and R1-D567 cells, but not in AR-negative PC-3 cells. R9-AR-PIP and PCNA-I1S elevate the levels of phospho-DNA-PKcs(S2056) and γH2AX, indicating DNA damage in response to radiation in AR-positive cells. The HRR is significantly attenuated by PCNA inhibitors PCNA-I1S, R9-AR-PIP, and T2AA in all four CRPC cells examined, and inhibited by Enzalutamide (Enz) only in 22RV1 cells. The cytotoxicity induced by X-ray radiation in androgen-dependent LNCaP cells is enhanced by Enz and a lower concentration of R9-AR-PIP in the colony formation assay. R9-AR-PIP at higher concentration reduces the colony formation and has an additive effect with X-ray radiation in all AR expressing cells, regardless of AR-FL and AR-Vs, but does not significantly alter the colony formation in AR-negative PC-3 cells. PCNA-I1S attenuates colony formation and has an additive effect with ionizing radiation in all four CRPC cells, regardless of AR expression status. CONCLUSION: These data provide a strong rationale for the therapy studies using PCNA-I1S or R9-AR-PIP in combination with X-ray radiation against CRPC tumors in preclinical models.

2.
J Appl Clin Med Phys ; 23(10): e13771, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36107002

RESUMO

The Professional Doctorate in Medical Physics (DMP) was originally conceived as a solution to the shortage of medical physics residency training positions. While this shortage has now been largely satisfied through conventional residency training positions, the DMP has expanded to multiple institutions and grown into an educational pathway that provides specialized clinical training and extends well beyond the creation of additional training spots. As such, it is important to reevaluate the purpose and the value of the DMP. Additionally, it is important to outline the defining characteristics of the DMP to assure that all existing and future programs provide this anticipated value. Since the formation and subsequent accreditation of the first DMP program in 2009-2010, four additional programs have been created and accredited. However, no guidelines have yet been recommended by the American Association of Physicists in Medicine. CAMPEP accreditation of these programs has thus far been based only on the respective graduate and residency program standards. This allows the development and operation of DMP programs which contain only the requisite Master of Science (MS) coursework and a 2-year clinical training program. Since the MS plus 2-year residency pathway already exists, this form of DMP does not provide added value, and one may question why this existing pathway should be considered a doctorate. Not only do we, as a profession, need to outline the defining characteristics of the DMP, we need to carefully evaluate the potential advantages and disadvantages of this pathway within our education and training infrastructure. The aims of this report from the Working Group on the Professional Doctorate Degree for Medical Physicists (WGPDMP) are to (1) describe the current state of the DMP within the profession, (2) make recommendations on the structure and content of the DMP for existing and new DMP programs, and (3) evaluate the value of the DMP to the profession of medical physics.


Assuntos
Física Médica , Internato e Residência , Humanos , Estados Unidos , Física Médica/educação , Acreditação , Relatório de Pesquisa , Educação de Pós-Graduação em Medicina
3.
Pediatr Blood Cancer ; 65(9): e27245, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29856521

RESUMO

BACKGROUND: Advances in radiation treatment (RT), specifically volumetric planning with detailed dose and volumetric data for specific brain structures, have provided new opportunities to study neurobehavioral outcomes of RT in children treated for brain tumor. The present study examined the relationship between biophysical and physical dose metrics and neurocognitive ability, namely learning and memory, 2 years post-RT in pediatric brain tumor patients. PROCEDURE: The sample consisted of 26 pediatric patients with brain tumor, 14 of whom completed neuropsychological evaluations on average 24 months post-RT. Prescribed dose and dose-volume metrics for specific brain regions were calculated including physical metrics (i.e., mean dose and maximum dose) and biophysical metrics (i.e., integral biological effective dose and generalized equivalent uniform dose). We examined the associations between dose-volume metrics (whole brain, right and left hippocampus), and performance on measures of learning and memory (Children's Memory Scale). RESULTS: Biophysical dose metrics were highly correlated with the physical metric of mean dose but not with prescribed dose. Biophysical metrics and mean dose, but not prescribed dose, correlated with measures of learning and memory. CONCLUSIONS: These preliminary findings call into question the value of prescribed dose for characterizing treatment intensity; they also suggest that biophysical dose has only a limited advantage compared to physical dose when calculated for specific regions of the brain. We discuss the implications of the findings for evaluating and understanding the relation between RT and neurocognitive functioning.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana/efeitos adversos , Deficiências da Aprendizagem/etiologia , Aprendizagem/efeitos da radiação , Transtornos da Memória/etiologia , Memória/efeitos da radiação , Dosagem Radioterapêutica , Adolescente , Antineoplásicos/uso terapêutico , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/cirurgia , Quimioterapia Adjuvante , Criança , Pré-Escolar , Terapia Combinada , Relação Dose-Resposta à Radiação , Feminino , Seguimentos , Hipocampo/efeitos da radiação , Humanos , Deficiências da Aprendizagem/psicologia , Imageamento por Ressonância Magnética , Masculino , Transtornos da Memória/psicologia , Neuroimagem , Testes Neuropsicológicos , Tamanho do Órgão , Radioterapia Adjuvante/efeitos adversos , Eficiência Biológica Relativa , Carga Tumoral , Aprendizagem Verbal/efeitos da radiação
4.
Cancers (Basel) ; 16(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38473367

RESUMO

Proton therapy (PT) is emerging as an effective and less toxic alternative to conventional X-ray-based photon therapy (XRT) for patients with advanced head and neck squamous cell carcinomas (HNSCCs) owing to its clustered dose deposition dosimetric characteristics. For optimal efficacy, cancer therapies, including PT, must elicit a robust anti-tumor response by effector and cytotoxic immune cells in the tumor microenvironment (TME). While tumor-derived exosomes contribute to immune cell suppression in the TME, information on the effects of PT on exosomes and anti-tumor immune responses in HNSCC is not known. In this study, we generated primary HNSCC cells from tumors resected from HNSCC patients, irradiated them with 5 Gy PT or XRT, and isolated exosomes from cell culture supernatants. HNSCC cells exposed to PT produced 75% fewer exosomes than XRT- and non-irradiated HNSCC cells. This effect persisted in proton-irradiated cells for up to five days. Furthermore, we observed that exosomes from proton-irradiated cells were identical in morphology and immunosuppressive effects (suppression of IFN-γ release by peripheral blood mononuclear cells) to those of photon-irradiated cells. Our results suggest that PT limits the suppressive effect of exosomes on cancer immune surveillance by reducing the production of exosomes that can inhibit immune cell function.

6.
Radiat Res ; 199(4): 422-428, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37039678

RESUMO

In vitro studies allow evaluation of normal or cancer cell responses to radiation, either alone or in combination with agents used to modify these biological responses. Ionizing radiation can be produced by a variety of particles and sources, with varying energy spectra, interaction probabilities, linear energy transfer, dose uniformity, dose rates, and delivery methods. Multiple radiation sources have been used to irradiate cells in the published literature. However, the equivalence of response in cell culture models across radiation sources has not been rigorously established. Moreover, current reporting of radiation source parameters lacks consistency and rigor which may impact the reproducibility of pre-clinical data between laboratories. Relevant choices of radiation source are also of high importance due to growing interest in comparing photon versus particle radiation effect on biological responses. Therefore, this study robustly evaluates the cellular response (cell survival, apoptosis, and DNA damage) of three distinct cell lines using four unique photon generating radiation sources. We hypothesize there may be subtle differences across the radiation sources, without an appreciable difference in cellular response. The four photon irradiation energies investigated, 662 keV, 100 kVp, 220 kVp, 6 MV, did produce subtle differences in DNA damage and cell survival when treating three distinct tumor cell lines. These variations in cellular response emphasize the need to carefully consider irradiation source, energy, and dose rate depending on study goal and endpoint.


Assuntos
Apoptose , Sobrevivência Celular , Dano ao DNA , Radiação Ionizante , Carcinoma de Células Escamosas de Cabeça e Pescoço , Humanos , Linhagem Celular Tumoral , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Sobrevivência Celular/efeitos da radiação , Apoptose/efeitos da radiação , Dano ao DNA/efeitos da radiação , Radiação Ionizante/classificação , Doses de Radiação
7.
Phys Med Biol ; 68(2)2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36595327

RESUMO

Objective.Mapping of dose delivery in proton beam therapy can potentially be performed by analyzing thermoacoustic emissions measured by ultrasound arrays. Here, a method is derived and demonstrated for spatial mapping of thermoacoustic sources using numerical time reversal, simulating re-transmission of measured emissions into the medium.Approach.Spatial distributions of thermoacoustic emission sources are shown to be approximated by the analytic-signal form of the time-reversed acoustic field, evaluated at the time of the initial proton pulse. Given calibration of the array sensitivity and knowledge of tissue properties, this approach approximately reconstructs the acoustic source amplitude, equal to the product of the time derivative of the radiation dose rate, mass density, and Grüneisen parameter. This approach was implemented using two models for acoustic fields of the array elements, one modeling elements as line sources and the other as rectangular radiators. Thermoacoustic source reconstructions employed previously reported measurements of emissions from proton energy deposition in tissue-mimicking phantoms. For a phantom incorporating a bone layer, reconstructions accounted for the higher sound speed in bone. Dependence of reconstruction quality on array aperture size and signal-to-noise ratio was consistent with previous acoustic simulation studies.Main results.Thermoacoustic source distributions were successfully reconstructed from acoustic emissions measured by a linear ultrasound array. Spatial resolution of reconstructions was significantly improved in the azimuthal (array) direction by incorporation of array element diffraction. Source localization agreed well with Monte Carlo simulations of energy deposition, and was improved by incorporating effects of inhomogeneous sound speed.Significance.The presented numerical time reversal approach reconstructs thermoacoustic sources from proton beam radiation, based on straightforward processing of acoustic emissions measured by ultrasound arrays. This approach may be useful for ranging and dosimetry of clinical proton beams, if acoustic emissions of sufficient amplitude and bandwidth can be generated by therapeutic proton sources.


Assuntos
Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Acústica , Som , Radiação Ionizante , Imagens de Fantasmas , Método de Monte Carlo
8.
J Appl Clin Med Phys ; 13(6): 3832, 2012 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-23149776

RESUMO

Some of the lowest voltages used in radiotherapy are termed Grenz and superficial X-rays of ~ 20 and ~ 100 kVp, respectively. Dosimetrically, the surface doses from these beams are calculated with the use of a free in-air air kerma measurement combined with a backscatter factor and the appropriate ratio of mass energy absorption coefficients from the measurement material to water. Alternative tools to the standard ion chamber for measuring the BSF are GAFCHROMIC EBT2 film and optically stimulated luminescent dosimeter (OSLD) crystals made from Al2O3. The scope of this project included making three different backscatter measurements with an Xstrahl-D3100 X-ray unit on the Grenz ray and superficial settings. These measurements were with OSLDs, GAFCHROMIC EBT2 film, and a PTW ionization chamber. The varied measurement methods allowed for intercomparison to determine the accuracy of the results. The ion chamber measurement was the least accurate, as expected from previous experimental findings. GAFCHROMIC EBT2 film proved to be a useful tool which gave reasonable results, and Landauer OSLDs showed good results for smaller field sizes and an increasing overresponse with larger fields. The specific backscatter factors for this machine demonstrated values about 5% higher than the universal values suggested by the AAPM and IPEMB codes of practice for the 100 kVp setting. The 20 kvp measured data from both techniques showed general agreement with those found in the BJR Supplement No. 10, indicating that this unit's Grenz ray spectrum is similar to those used in previous experimental work.


Assuntos
Dosimetria Fotográfica/instrumentação , Dispositivos Ópticos , Filme para Raios X , Dosimetria Fotográfica/métodos , Humanos , Espalhamento de Radiação
9.
Med Dosim ; 47(2): 142-145, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34996678

RESUMO

The purpose of this study was to compare dose to anterior organs at risk (OARs) and quantify the risk of developing secondary malignancy (SMN) in pediatric patients treated with vertebral-body-sparing (VBS) vs vertebral body (VB) pencil beam scanning proton craniospinal irradiation (CSI). Comparative plans of VBS and VB CSI were created for 10 previously treated patients. Dose-volume histograms were used to evaluate dose to OARs. Absolute excess risk of SMN was calculated according to the organ-specific, radiation-induced cancer incidence based on the organ equivalent dose. OAR dosimetric parameters and absolute excess risk of SMN were compared for VBS and VB plans using the Kruskal-Wallis H test (α = 0.05). VBS CSI leads to significantly lower radiation dose to the heart, esophagus, kidney, liver and bowel. Excluding the vertebral body also significantly decreases the absolute excess risk of SMN for liver, esophagus and bowel. For these reasons, implementation of VBS pencil beam scanning proton CSI should be considered.


Assuntos
Radiação Cranioespinal , Segunda Neoplasia Primária , Terapia com Prótons , Criança , Radiação Cranioespinal/efeitos adversos , Humanos , Segunda Neoplasia Primária/etiologia , Terapia com Prótons/efeitos adversos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Corpo Vertebral
10.
Med Phys ; 49(11): 6765-6773, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36114793

RESUMO

PURPOSE: FLASH radiotherapy (FLASH-RT) is the potential for a major breakthrough in cancer care, as preclinical results have shown significantly reduced toxicities to healthy tissues while maintaining excellent tumor control. However, FLASH conditions were not considered in the current proton facilities' shielding designs. The purpose of this study is to validate the adequacy of conventionally shielded proton rooms used for FLASH-RT. METHODS: Clinical FLASH irradiations typically take place in a few 100 ms, orders of magnitude shorter than the response time of the wide-energy neutron detector (WENDI-II). The nozzle beam current (representing the dose rate) dependence of the WENDI-II detector response was empirically determined to stabilize with a beam current of ≤10 nA at the measurement point with the highest dose rate. A large, predefined proton transmission FLASH plan (250 MeV, 7 × 20 cm2 , 8 Gy at isocenter) was commissioned as part of a FLASH clinical trial. For purpose of this study, that field was adjusted from 250 to 244 MeV, allowing a lower beam current of 10 nA to provide reliable detector response. Radiation surveys were performed for the proton beams with/without extra beam stopper (30 × 30 × 40-cm3 solid water slabs) at 0°, 90°, 180°, and 270° gantry angles. RESULTS: Ambient doses were recorded at seven different locations. A 170-nA beam current, commonly used for clinical FLASH plans, was chosen to normalize the average ambient dose rate to FLASH conditions. Assuming 200-Gy/h workload (25 FLASH beams, 8 Gy/beam), annual occupational dose at controlled areas was calculated. For all gantry angles, ≤0.4 mSv/year is expected at treatment room door. The highest ambient dose, 2.46 mSv/year, ∼5% of the maximum annual permissible occupational dose, was identified at the isocenter of the adjacent treatment room with 90° gantry. CONCLUSION: These survey results indicate that our conventionally shielded proton rotating gantry rooms result in acceptable occupational and public doses when the transmission FLASH beams delivered at four cardinal gantry angles based on 200-Gy/h workload assumption. These findings support that FLASH clinical trials in our conventionally shielded proton facilities can be safely implemented.


Assuntos
Prótons
11.
Sci Rep ; 12(1): 8221, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35581287

RESUMO

The pathological changes in epigenetics and gene regulation that accompany the progression of low-grade to high-grade gliomas are under-studied. The authors use a large set of paired atac-seq and RNA-seq data from surgically resected glioma specimens to infer gene regulatory relationships in glioma. Thirty-eight glioma patient samples underwent atac-seq sequencing and 16 samples underwent additional RNA-seq analysis. Using an atac-seq/RNA-seq correlation matrix, atac-seq peaks were paired with genes based on high correlation values (|r2| > 0.6). Samples clustered by IDH1 status but not by grade. Surprisingly there was a trend for IDH1 mutant samples to have more peaks. The majority of peaks are positively correlated with survival and positively correlated with gene expression. Constructing a model of the top six atac-seq peaks created a highly accurate survival prediction model (r2 = 0.68). Four of these peaks were still significant after controlling for age, grade, pathology, IDH1 status and gender. Grade II, III, and IV (primary) samples have similar transcription factors and gene modules. However, grade IV (recurrent) samples have strikingly few peaks. Patient-derived glioma cultures showed decreased peak counts following radiation indicating that this may be radiation-induced. This study supports the notion that IDH1 mutant and IDH1 wildtype gliomas have different epigenetic landscapes and that accessible chromatin sites mapped by atac-seq peaks tend to be positively correlated with expression. The data in this study leads to a new model of treatment response wherein glioma cells respond to radiation therapy by closing open regions of DNA.


Assuntos
Glioma , Cromatina/genética , Sequenciamento de Cromatina por Imunoprecipitação , DNA/genética , Glioma/genética , Glioma/patologia , Humanos , Fatores de Transcrição/genética
12.
AJR Am J Roentgenol ; 196(2): 374-81, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21257890

RESUMO

OBJECTIVE: The purpose of this article is to evaluate the relationship between apparent diffusion coefficient (ADC) values, tumor volume, and total Gleason grade in patients with prostate cancer before radical prostatectomy. MATERIALS AND METHODS: A total of 110 patients with prostate cancer who had undergone endorectal prostate MRI at 1.5 T before radical prostatectomy were included. ADC values were derived by drawing a region of interest on the histologically confirmed tumors. Tumor volume was obtained by manual segmentation on T2-weighted images (T2WIs) and ADC maps. The relationship between the ADC value or tumor volume and the Gleason grade was assessed by using multivariate mixed linear and effect models. Multivariate analysis was performed to evaluate the accuracy of ADC and tumor volume in determining the aggressiveness of prostate cancer. RESULTS: A total of 197 tumors were studied; 128 (65%) tumors were found in the peripheral zone and 69 (35%) were found in the central gland. The ADC value was found to be negatively correlated with the Gleason grade (r = -0.39 for peripheral zone cancer). Higher ADC values were found to be associated with lower Gleason grades in the peripheral zone prostate cancers. No association was found in the central zone prostate cancers. Both ADC values and tumor volumes were found to significantly predict tumor aggressiveness, specifically in the peripheral zone (area under the curve, 0.78). CONCLUSION: ADC values were found to be negatively correlated with the postsurgical Gleason grade in patients with prostate cancer. Our results show that ADC values might help to predict prostate cancer, especially for tumors in the peripheral zone. Given the substantial overlap in the ADC values, the addition of other MR parameters, such as volumetry, and technical improvements in diffusion-weighted imaging might improve accuracy in the stratification of patients.


Assuntos
Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Adulto , Idoso , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Prostatectomia , Estudos Retrospectivos , Carga Tumoral
13.
J Appl Clin Med Phys ; 11(3): 3136, 2010 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-20717081

RESUMO

The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity-modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were designated for thermoluminescent dosimeter (TLD) placement. Following the RTOG IMRT Protocol 0522, treatment of the primary tumor and involved nodes (PTV70) and subclinical disease sites (PTV56) was planned utilizing IMRT to 70Gy and 56 Gy. Clinically acceptable treatment plans were produced for linac and TomoTherapy treatments. TLDs were placed and each treatment plan was delivered to the anthropomorphic phantom four times. Within 2.5 cm (one helical TomoTherapy field width) superior and inferior to the field edges, normal tissue doses were on average 45% lower using linear accelerator. Beyond 2.5 cm, the helical TomoTherapy normal tissue dose was an average of 52% lower. The majority of points proved to be statistically different using the Student's t-test with p > 0.05. Using one method of calculation, probability of a secondary malignancy was 5.88% for the linear accelerator and 4.08% for helical TomoTherapy. Helical TomoTherapy delivers more dose than a linac immediately above and below the treatment field, contributing to the higher peripheral doses adjacent to the field. At distances beyond one field width (where leakage is dominant), helical TomoTherapy doses are lower than linear accelerator doses.


Assuntos
Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/instrumentação , Tomografia Computadorizada Espiral , Neoplasias da Língua/radioterapia , Humanos , Órgãos em Risco , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Dosimetria Termoluminescente
14.
Med Phys ; 35(4): 1464-75, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18491541

RESUMO

The effects of intrafraction respiratory motion on nonhelical intensity-modulated radiotherapy have been well addressed in the literature, both theoretically and experimentally. However, the consequences of respiratory motion on helical tomotherapy, for patient-specific treatment plans, are less well known. Parameters specific to this treatment modality such as pitch, gantry speed, and degree of modulation may play prominent roles in radiation delivery with respect to intrafraction respiratory motion. This phantom-based study specifically addressed the effects of intrafraction respiratory motion on whole breast helical tomotherapy. A device capable of driving an acrylic phantom with reproducible, one-dimensional, anterior-posterior motion resembling a sinusoid of 4.6 mm crest-trough amplitude was developed. A plan to irradiate the corner of an acrylic phantom using parameters typical of a whole breast helical tomotherapy technique was developed using the TomoTherapy Hi-Art-II System. The treatment was delivered to the phantom, with Kodak EDR2 film in the axial plane, for each of the following conditions: (i) phantom at 270 degrees initial sinusoidal phase and 12 cycles/min motion, (ii) phantom at 270 degrees initial sinusoidal phase and 18 cycles/min motion, and (iii)-(v) phantom at 18 cycles/min motion with 0 degrees, 90 degrees, and 180 degrees initial sinusoidal phases. A measure of technique reproducibility was also performed for several irradiations with the phantom static at 270 degrees initial sinusoidal phase. Films were processed using a Kodak MIN-R mammography film processor, scanned with a Vidar NXR-16 Dosimetry Pro scanner and analyzed with RIT113 v.4.2 software. Films were compared to a reference film irradiated under the conditions of no motion and 270 degrees sinusoidal phase. For all comparisons, 5% dose difference threshold, 3% dose difference and 2 mm distance-to-agreement gamma analysis, and isodose plots were generated. The results of this study show a small area of greater than 5% decrease in dose at the phantom's anterior surface and a 1.5-3 mm posterior-medial shift of isodose lines in the penumbral and apex regions of the PTV. Frequency and phase effects are apparent within the PTV where dose varies with high spatial frequency. As the reference film was produced by delivering the treatment plan to the phantom static and in the position corresponding to maximum expiration, results are representative of extreme deviations between planned and delivered dose with respect to sinusoidal motion of clinically relevant magnitudes and frequencies.


Assuntos
Artefatos , Neoplasias da Mama/radioterapia , Movimento , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mecânica Respiratória , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Med Dosim ; 43(2): 150-158, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29609845

RESUMO

Brachytherapy was among the first methods of radiotherapy and has steadily continued to evolve. Here we present a brief review of the progression of dose calculation methods in brachytherapy to the current state-of-the art computerized methods for heterogeneity correction. We further review the origin and development of the BrachyVision (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system and evaluate dosimetric results from 12 patients implanted with the strut-assisted volumetric implant (SAVI) applicator (Cianna Medical, Aliso Viejo, CA) for accelerated partial breast irradiation (APBI). Dosimetric results from plans calculated using homogenous and heterogeneous algorithms have been compared to investigate the impact of heterogeneity corrections. Our study showed large percent difference between mean cardiac doses 11.8 ± 6.2% (p = 0.0007) calculated with and without heterogeneity corrections. Our findings are consistent with those of others, indicating an overestimation of the distal dose to organs-at-risk by traditional methods, especially at interfaces between air and tissue.


Assuntos
Braquiterapia/tendências , Planejamento da Radioterapia Assistida por Computador/métodos , Coração , Humanos , Tratamentos com Preservação do Órgão , Doses de Radiação
16.
Bioengineering (Basel) ; 5(3)2018 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-29996496

RESUMO

Gel dosimeters are attractive detectors for radiation therapy, with properties similar to biological tissue and the potential to visualize volumetric dose distributions. Radio-fluorogenesis is the yield of fluorescent chemical products in response to energy deposition from ionizing radiation. This report shares the development of a novel radio-fluorogenic gel (RFG) dosimeter, gelatin infused with coumarin-3-carboxlyic acid (C3CA), for the quantification of imparted energy. Aqueous solutions exposed to ionizing radiation result in the production of hydroxyl free radicals through water radiolysis. Interactions between hydroxyl free radicals and coumarin-3-carboxylic acid produce a fluorescent product. 7-hydroxy-coumarin-3-carboxylic acid has a blue (445 nm) emission following ultra-violet (UV) to near UV (365⁻405 nm) excitation. Effects of C3CA concentration and pH buffers were investigated. The response of the RFG was explored with respect to strength, type, and exposure rate of high-energy radiation. Results show a linear dose response relationship independent of energy and type, with a dose-rate dependency. This report demonstrates increased photo-yield with high pH and the utility of gelatin-RFG for phantom studies of radiation dosimetry.

17.
J Neurosurg ; 125(5): 1167-1170, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26918472

RESUMO

This case report documents the migration of 3 iodine-125 (125I) seeds from the tumor resection cavity into brain parenchyma over a 7-year period. A 66-year-old woman had a history of metastatic ovarian carcinoma, nickel allergy, and reaction to a titanium hip implant that required reoperation for hardware removal. In this unique case of parenchymal migration, the seed paths seemed to follow white matter tracts, traveling between 18.5 and 35.5 mm from the initial implant site. The patient's initial neurological decline, which was thought to be related to radiation necrosis, appeared to stabilize with medical therapy. She subsequently developed progressive right hemispheric edema that resulted in neurological deterioration and death. Considering her previous reactions to nickel and titanium, the authors now speculate that her later clinical course reflected an allergic reaction to the titanium casing of the 125I seeds. Containing a trace amount of nickel, 125I seeds can elicit a delayed hypersensitivity reaction in patients with a history of nickel dermatitis. Preoperative patch testing is recommended in these patients, and 125I seed implantation should be avoided in those who test positive.


Assuntos
Braquiterapia/efeitos adversos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Encéfalo , Migração de Corpo Estranho/etiologia , Radioisótopos do Iodo/uso terapêutico , Tecido Parenquimatoso , Idoso , Feminino , Humanos , Neoplasias Ovarianas/patologia
18.
Acad Radiol ; 23(8): 987-93, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27287714

RESUMO

RATIONALE AND OBJECTIVES: This work aimed to study the effects of scanner model and study protocol on radiation dose received by breast tissues from 64-slice computed tomography (CT) studies. MATERIALS AND METHODS: Four scanner models and three study protocols were used in scanning an anthropomorphic phantom with breast modules. Each protocol follows recommendations or guidelines from the American Association of Physicists in Medicine and the American College of Radiology. Twenty thermoluminescent dosimeters were placed inside the breast modules to measure breast tissue doses. Both the absolute and the normalized breast tissue doses were analyzed. RESULTS: The mean glandular doses of a lung cancer screening CT, a chest/abdomen/pelvis CT, and a virtual colonoscopy CT are equivalent to less than 1, 5-7, and 1-3 two-view digital mammograms, respectively, for a standard-sized patient. The normalized breast dose differs significantly (P < 0.01) between lung cancer screening CT and chest/abdomen/pelvis CT; however, it shows less than ±10% variation among scanner models for the same protocol. In virtual colonoscopy CT, breast tissue dose decreases with the distance between local tissues to the edge of the x-ray field, although the decreasing trend varies for different scanner models and protocol settings. CONCLUSIONS: When breasts are entirely included in the primary x-ray field, breast dose by 64-slice CT is mainly protocol dependent, with the normalized breast dose about 15% lower for protocols with modulated mA than for those with constant mA; when breasts are only partially included in the primary beam field, breast dose by 64-slice CT is dependent on both the scanner model and the protocol settings.


Assuntos
Mama/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Projetos de Pesquisa
19.
Med Dosim ; 29(4): 271-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15528069

RESUMO

The purpose of this study was to present a theoretical analysis of how the presence of bone in interstitial brachytherapy affects dose rate distributions. This study was carried out using a Monte Carlo simulation of the dose distribution in homogeneous medium for 3 commonly used brachytherapy seeds. The 3 seeds investigated in this study are iridium-192 (192Ir) iodine-125 (125I), and palladium-103 (103Pd). The computer code was validated by comparing the specific dose rate (Lambda), the radial dose function g(r), and anisotropy function F(r,theta;) for all 3 seeds with the AAPM TG-43 dosimetry formalism and current literature. The 192Ir seed resulted in a dose rate of 1.115 +/- 0.001 cGy-hr(-1)-U(-1), the 125I seed resulted in a dose rate of 0.965 +/- 0.006 cGy/h(-1)/U(-1), and the 103Pd seed resulted in a dose rate of 0.671 +/- 0.002 cGy/h(-1)/U(-1). The results for all 3 seeds are in good agreement with the AAPM TG-43 and current literature. The validated computer code was then applied to a simple inhomogeneous model to determine the effect bone has on dose distribution from an interstitial implant. The inhomogeneous model showed a decrease in dose rate of 2% for the 192Ir, an increase in dose rate of 84% for 125I, and an increase in dose rate of 83% for the 103Pd at the surface of the bone nearest to the source.


Assuntos
Braquiterapia , Radioisótopos do Iodo/administração & dosagem , Radioisótopos de Irídio/administração & dosagem , Método de Monte Carlo , Análise Numérica Assistida por Computador , Paládio/administração & dosagem , Anisotropia , Humanos , Glândula Parótida/efeitos da radiação , Imagens de Fantasmas , Valor Preditivo dos Testes , Dosagem Radioterapêutica
20.
Pract Radiat Oncol ; 4(5): e195-e201, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25194105

RESUMO

PURPOSE: Currently, most high-grade glioma patients undergo a 1.5T brain magnetic resonance (MR) for radiation treatment planning. We hypothesized that 3T MR imaging (MRI) scanning is superior to 1.5T due to higher signal-to-noise ratio (SNR), and thus will result in more accurate quantification of tumor volumes. The purpose of this prospective study was to determine differences in radiation planning volumes for high-grade gliomas when scanned on 3T MR versus 1.5T MR. METHODS AND MATERIALS: In this prospective controlled trial, 23 patients with high-grade gliomas underwent brain MRI scanning in both 1.5T and 3T field strengths within a 24-hour period; no steroids or treatment changes were made in-between scans. After 3 investigators contoured the T2 fast low-angle inversion recovery (FLAIR) abnormality (gross tumor volumes or [GTV]) for all patients, clinical target volume (CTV) and planning treatment volumes (PTV) were defined. Calculations by an independent investigator included volumes, standard deviations, SNRs, and contrast-to-noise ratios (CNRs); statistical analysis was performed on raw data. RESULTS: Planning treatment volume ratios (3T:1.5T) for each investigator were 0.95 ± 0.12 (range, 0.64-1.10), 0.98 ± 0.10 (range, 0.64-1.16), and 0.99 ± 0.06 (range, 0.86-1.13). By paired 2-tailed t test, these volumes were not statistically different (P = .051), although there is a trend to 3T producing smaller volumes than 1.5T. Dice similarity coefficients were 0.90 ± 0.05, 0.90 ± 0.06, and 0.91 ± 0.05 for the investigators. CONCLUSIONS: Planning target volumes for high-grade gliomas were similar at 3T and 1.5T MR using our standard imaging protocols. However, in some patients, the 3T MR may reveal substantially smaller tumor volume due to inferior conspicuity of the lesion. These findings imply that while overall the radiation target volumes are comparable, there are differences in CNR and SNR that lead to differences in individual patients. The 1.5T may be better for gaining conspicuity of the tumor.


Assuntos
Neoplasias Encefálicas/radioterapia , Glioma/radioterapia , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Estudos Prospectivos , Razão Sinal-Ruído , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA