Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Exp Dermatol ; 33(8): e15150, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39113601

RESUMO

Acne is a chronic inflammatory skin condition that involves Cutibacterium acnes (C. acnes), which is classified into six main phylotypes (IA1, IA2, IB, IC, II and III). Acne development is associated with loss of C. acnes phylotype diversity, characterised by overgrowth of phylotype IA1 relative to other phylotypes. It was also shown that purified extracellular vesicles (EVs) secreted by C. acnes can induce an acne-like inflammatory response in skin models. We aimed to determine if the inflammatory profile of EVs secreted by C. acnes phylotype IA1 from an inflammatory acne lesion was different from C. acnes phylotype IA1 from normal skin, thus playing a direct role in the severity of inflammation. EVs were produced in vitro after culture of two clinical strains of C. acnes phylotype IA1, T5 from normal human skin and A47 from an inflammatory acne lesion, and then incubated with either human immortalised keratinocytes, HaCaT cells, or skin explants obtained from abdominoplasty. Subsequently, quantitative PCR (qPCR) was performed for human ß-defensin 2 (hBD2), cathelicidin (LL-37), interleukin (IL)-1ß, IL-6, IL-8, IL-17α and IL-36γ, and ELISA for IL-6, IL-8 and IL-17α. We found that EVs produced in vitro by C. acnes derived from inflammatory acne lesions significantly increased the pro-inflammatory cytokines and anti-microbial peptides at both transcriptional and protein levels compared with EVs derived from normal human skin. We show for the first time that C. acnes EVs from inflammatory acne play a crucial role in acne-associated inflammation in vitro and that C. acnes phylotype IA1 collected from inflammatory acne lesion and normal skin produce different EVs and inflammatory profiles in vitro.


Assuntos
Acne Vulgar , Vesículas Extracelulares , Queratinócitos , Propionibacterium acnes , Humanos , Vesículas Extracelulares/metabolismo , Acne Vulgar/microbiologia , Queratinócitos/microbiologia , Pele/microbiologia , Inflamação/microbiologia , Interleucina-6/metabolismo , Interleucina-8/metabolismo , Células HaCaT , Interleucina-1alfa/metabolismo , Interleucina-1beta/metabolismo , Citocinas/metabolismo , Interleucina-17/metabolismo , Propionibacteriaceae
2.
J Surg Res ; 288: 298-308, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37058986

RESUMO

INTRODUCTION: Recent microsurgical reconstruction techniques benefit from the use of skin and perforator flaps that spare the donor sites. Studies on these skin flaps in rat models are numerous but there is currently no reference regarding the position of the perforators, their caliber, and the length of the vascular pedicles. METHODS: We performed an anatomical study on 10 Wistar rats and 140 vessels: cranial epigastric (CE), superficial inferior epigastric (SIE), lateral thoracic (LT), posterior thigh (PT), deep iliac circumflex (DCI) and posterior intercostal (PIC) vessels. The evaluation criteria were the external caliber, the length of the pedicle, and the position of the vessels reported on the skin surface. RESULTS: Data from the six perforator vascular pedicles are reported, with figures illustrating the orthonormal reference frame, the representation of the vessel's position, the cloud of points corresponding to the various measurements, and the average representation of the collected data. The analysis of the literature does not find similar studies; the different vascular pedicles are discussed as well as the limitations of our study: evaluation of cadaver specimen, presence of the very mobile panniculus carnosus, other perforator vessels not evaluated as well as the precise definition of perforating vessels. CONCLUSIONS: Our work describes the vascular calibers, pedicle lengths, and location of birth and arrival at the skin of the perforator vessels PT, DCI, PIC, LT, SIE, and CE in rat animal models. This work, without an equivalent in the literature, lays the foundation for future studies about flap perfusion, microsurgery, and super microsurgery learning.


Assuntos
Retalho Perfurante , Retalhos Cirúrgicos , Ratos , Animais , Ratos Wistar , Retalhos Cirúrgicos/irrigação sanguínea , Pele , Cadáver , Microcirurgia/métodos , Retalho Perfurante/irrigação sanguínea
3.
J Plast Reconstr Aesthet Surg ; 94: 46-49, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38759510

RESUMO

BACKGROUND: In the existing literature, assessing transgender patients' quality of life after surgery, especially using standardized surveys, is rare. The nipple sensation regarding the operating technique has neither been studied in a prospective nor standardized way. METHODS: For one year, we prospectively assessed transgender patients operated on for a gender-affirming chest surgery in our unit. Each patient answered the BREAST-Q© survey and the BODY-Q© chest module survey before and six months after the surgery. In addition, a measure of nipple sensation was performed using Semmes-Weinstein monofilaments pre-and post-operatively to compare surgical techniques. RESULTS: Fifty-one patients (102 breasts) were included in our study. The average age was 23.1 years and the average BMI was 24.8 kg/m2. Twenty-one patients (45%) had double incision and free nipple graft mastectomy, 14 (27%) patients had double incision and inferior pedicle mastectomy, while the 14 (27%) other patients had a semi-circular technique. Our study shows an improvement in all the scores of the surveys after surgery (p < 0.0001). Patients with double incision and inferior pedicle mastectomies rated a significantly higher satisfaction with nipples (p = 0.013) and significantly better sexual well-being (p = 0.007) than other techniques. In addition, preservation of nipple sensation was shown in patients operated by semi-circular technique (p < 0.001) and inferior pedicle technique (p < 0.0001). CONCLUSIONS: Our prospective study confirms the significant improvement in the quality of life of transgender patients after chest gender-affirming surgery. Double incision with inferior pedicle seems to provide better satisfaction with nipples, higher sexual well-being, and preservation of nipple sensation.


Assuntos
Mamilos , Satisfação do Paciente , Qualidade de Vida , Sensação , Humanos , Mamilos/cirurgia , Feminino , Masculino , Estudos Prospectivos , Adulto , Adulto Jovem , Sensação/fisiologia , Cirurgia de Readequação Sexual/métodos , Pessoas Transgênero , Mamoplastia/métodos , Inquéritos e Questionários
4.
J Plast Reconstr Aesthet Surg ; 84: 223-232, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37343423

RESUMO

INTRODUCTION: Breast reconstruction using Deep Inferior Epigastric Perforator (DIEP) flap involves complementary surgeries such as lipofilling, symmetrization, and nipple-areolar complex (NAC) reconstruction. Their role and impact have not been explored yet after the DIEP flap use. MATERIAL AND METHODS: A retrospective study was performed to evaluate the impact of complementary surgeries on the quality of life of 75 patients after DIEP flap breast reconstruction between 2012 and 2021, comparing the BREAST-Q© score of two groups, patients with DIEP flap only reconstruction and patients with DIEP flap and additional surgeries. Satisfaction for each surgery was assessed using a numeric visual scale on five dimensions (esthetic, self-image, confidence in society, pain, and intimate relationship). Complications and healthcare pathways were also recorded. RESULTS: Psychosocial well-being (Q1 BREAST-Q©), satisfaction with medical team (Q9) and with surgeon (Q11) was superior in group 2 (p = 0041, p = 0.001 and p = 0.001 respectively). NAC reconstruction improved BREAST-Q© (p = 0029) by regression analysis and was deemed indispensable by 64% of the patients. An important satisfaction is observed after each surgery (DIEP flap, symmetrization, lipofilling and NAC reconstruction). Complications were uncommon (0-4%) for lipofilling and NAC reconstruction and notable but harmless for symmetrization (wound dressings more than a month in 17%). CONCLUSION: Complementary surgeries, especially NAC reconstruction, improved BREAST-Q© score, and have a major impact on satisfaction with minor complications. These surgeries should always be proposed to the patients to assess a satisfactory breast reconstruction using DIEP flap.


Assuntos
Neoplasias da Mama , Retalhos de Tecido Biológico , Mamoplastia , Retalho Perfurante , Humanos , Feminino , Estudos Retrospectivos , Retalhos de Tecido Biológico/cirurgia , Qualidade de Vida , Retalho Perfurante/cirurgia , Artérias Epigástricas/cirurgia , Mamoplastia/métodos , Neoplasias da Mama/cirurgia
5.
J Plast Reconstr Aesthet Surg ; 83: 94-97, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37271002

RESUMO

INTRODUCTION: The microsurgical literature reports the vascular calibers of the vessels studied even though the method of measurement of these vessels is very rarely reported. MATERIAL AND METHOD: We performed a metrological study evaluating three methods to measure the external calibers of catheters corresponding to microsurgical and super-microsurgical vessels (1.2 mm, 0.8 mm, and 0.6 mm). Six evaluators measured 15 catheters of three different hidden diameters by each of the three methods applicable in clinical practice: standard graduated ruler, Shinwa® micrometric ruler, and ImageJ® software from a photograph. Accuracy and reliability of the measurements were assessed by studying the inter- and intra-rater and inter-method coefficients (variants of the intra-class coefficient (ICC)) and analysis of the IC95% of the ICCs. RESULTS: Intra class correlation ICC "intra-rater" coefficient finds for the standard rule 0.81 [0.65-0.93], Shinwa® rule 0.86 [0.67-0.96], and for the ImageJ® software 0.97 [0.94-0.99]. The "Inter-rater" ICC shows respectively the coefficient 0.51 [0.23 and max 0.93], 0.87 [0.75-0.95], and 0.95 [0.89-0.98]. It appears that the graduated decimeter is the least reliable method of measurement, the Shinwa® ruler presents acceptable reliability but requires the purchase of equipment. The reliability of ImageJ® software is the best and appears to be the most reliable method. CONCLUSION: Our original study, with no equivalent in the scientific literature, demonstrates objectively the great accuracy and reliability of a method of measurement of vascular calibers in micro and super microsurgery using intraoperative photography and the use of free computer software.


Assuntos
Microcirurgia , Software , Humanos , Reprodutibilidade dos Testes , Fotografação , Variações Dependentes do Observador
6.
Cureus ; 15(8): e42917, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37664396

RESUMO

Traumatic amputation is a severe injury that requires urgent surgical care. A fillet-free flap from the amputated limb is the most conservative way to ensure proper coverage of the stump when replantation is not possible. We report the case of a male patient who suffered from a traumatic limb amputation in a motorcycle accident. A free fillet flap from the posterior compartment of the leg carrying the posterior tibial pedicle, the soleus muscle, and skin tissue harvested from the amputated limb was performed to cover the amputation stump and thus allow preservation of the knee joint. In our case report, the patient conserved almost maximal knee joint range of motion (130°). He regained the ability to walk only two months after the initial trauma. Prosthetic fitting occurred quickly and without any particular issues throughout the process. Regarding quality of life, after one year, our patient had a five-level EQ-5D version (EQ-5D-5L) score of 21,221, and his 36-Item Short Form Survey (SF-36) score was divided between the five components in 85 points in physical functioning, 100 points in role limitations due to physical health, 100 points in role limitations due to emotional problems, 50 points in energy/fatigue, 68 points in emotional well-being, 75 points in social functioning, 45 points in pain, and 95 points in general health. This technique helped provide good coverage of the stump while preserving a functional knee joint, allowing for effective prosthetic fitting in the future and therefore optimizing our patient's quality of life.

7.
Eur J Dermatol ; 33(4): 419-425, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37823493

RESUMO

BACKGROUND: Therapeutic make-up has previously been proven to be efficacious in improving the quality of life of patients with facial dermatoses, but its efficacy has only been assessed in the short term (less than one month). OBJECTIVES: This study aimed to determine whether the effect of therapeutic make-up on patients' quality of life persists in the longer term, i.e., after one year. MATERIALS & METHODS: This study included 53 patients who benefited from a therapeutic make-up consultation in the context of various facial dermatoses (pigmentation disorders, scars, acne, rosacea, eczema, adverse events of chemotherapy, etc.). Patients were asked to complete a quality-of-life questionnaire to obtain the Skindex score at baseline, and one month (M1) and one year (M12) after the first consultation. The difference in scores between baseline and M12 was calculated and Student's t-test was used to assess the significance of the values. RESULTS: Our results showed a significant difference (p<0.001) with an improvement in quality-of-life score by more than 10% between baseline and M12, for all the dimensions of the score (Emotion, Symptoms and Functioning). Based on the subgroup analysis, this score particularly improved for patients suffering with acne or rosacea (p=0.009) and scars (p=0.43), as well as for younger patients (<30 years old) (p=0.009). CONCLUSION: This is the first study to demonstrate a persistent long-term effect of therapeutic make-up on the quality of life of patients with facial dermatoses.


Assuntos
Acne Vulgar , Dermatoses Faciais , Rosácea , Humanos , Adulto , Cicatriz/patologia , Qualidade de Vida , Acne Vulgar/tratamento farmacológico , Rosácea/tratamento farmacológico , Dermatoses Faciais/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA