Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 251(3): 839-45, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22886095

RESUMO

PURPOSE: To evaluate the transient pattern electroretinogram (t-PERG) and the retinal nerve fiber layer (RNFL) thickness in eyes with ocular hypertension (OH) and normal short-wavelength automated perimetry (SWAP). METHODS: In 26 patients with bilateral OH with normal SWAP, and in 26 age and sex matched healthy controls, t-PERG recording and RNFL thickness measurement were performed. Mean deviation (MD) and pattern standard deviation (PSD) of a reliable full threshold 24-2 SWAP were considered. RNFL thickness was determined by OCT3. Monocular PERG were recorded by using a black and white checkerboard pattern (check size 0.9°, contrast 100 %, mean luminance 80 cd/m2) generated on a monitor and reversed in contrast (four reversals per second, 2 Hz) at a distance of 70 cm. Patients had optimal correction at viewing distance; no mydriatic or miotic eye drops were used. Silver/silver chloride skin electrodes were placed over the lower eyelids in the stimulated eye (active electrode) and in the patched eye (reference electrode); ground electrode was in the Fpz scalp. Peak-to peak amplitude of P50 (N35-P50) and N95 (P50-N95) waves, and implicit time of P50, were considered. RESULTS: Compared to controls, in OH eyes, a reduction of N35-P50 amplitude (2.86 ± 1.49 vs. 3.77 ± 1.08 microvolts, -24.1 %, t-test p = 0.015), of average RNFL thickness (88 ± 11 vs. 96 ± 10 µm, -9.5 %, t-test p = 0.002), and of RNFL thickness in superior (p = 0.015) and inferior quadrant (p < 0.001), were found. Multivariate analysis showed that in OH eyes, N35-P50 amplitude was inversely related to intraocular pressure (IOP) (p = 0.001); no correlation was found between N35-P50 amplitude and MD, PSD, CCT or RNFL thickness. CONCLUSIONS: In OH eyes, both PERG and RNFL thickness changes occur in hypertensive eyes with undamaged SWAP; the correlation of PERG amplitude with IOP, but not with RNFL thickness, suggests that such PERG changes are an effect of the IOP on retinal ganglion cells, rather than a sign of their loss.


Assuntos
Fibras Nervosas/patologia , Hipertensão Ocular/fisiopatologia , Retina/fisiopatologia , Células Ganglionares da Retina/patologia , Campos Visuais/fisiologia , Adulto , Eletrorretinografia , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Acuidade Visual/fisiologia , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA