Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Appl Psychophysiol Biofeedback ; 48(4): 393-401, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37341838

RESUMO

The value of biofeedback before elective coronary computed tomography angiography (CCTA) to reduce patients' heart rates (HR) was investigated in the current work. Sixty patients who received CCTA to exclude coronary artery disease were included in our study and separated into two groups: with biofeedback (W-BF) and without biofeedback (WO-BF). The W-BF group used a biofeedback device for 15 min before CCTA. HR was determined in each patient at four measurement time points (MTP): during the pre-examination interview (MTP1), positioning on the CT patient table before CCTA (MTP2), during CCTA image acquisition (MTP3), and after completing CCTA (MTP4). If necessary, beta-blockers were administered in both groups after MTP2 until a HR of less than 65 bpm was achieved. Two board-certified radiologists subsequently assessed the image quality and analyzed the findings. Overall, the need for beta-blockers was significantly lower in patients in the W-BF group than the WO-BF group (p = 0.032). In patients with a HR of 81-90, beta-blockers were not required in four of six cases in the W-BF group, whereas in the WO-BF group all patients needed beta-blockers (p = 0.03). The amount of HR reduction between MTP1 and MTP2 was significantly higher in the W-BF compared to the WO-BF group (p = 0.028). There was no significant difference between the W-BF and WO-BF groups regarding image quality (p = 0.179). By using biofeedback prior to elective CCTA, beta-blocker use could be decreased without compromising CT image quality and analysis, especially in patients with an initial HR of 81-90 bpm.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Humanos , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Frequência Cardíaca/fisiologia , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X
2.
J Magn Reson Imaging ; 52(5): 1510-1524, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32537799

RESUMO

BACKGROUND: Free-breathing noncontrast-enhanced (non-CE) magnetic resonance angiography (MRA) techniques are of considerable interest for the diagnosis of acute pulmonary embolism (APE), due to the possibility for repeated examinations, avoidance of side effects from iodine-based contrast agents, and the absence of ionizing radiation exposure as compared to CE-computed tomographic angiography (CTA). PURPOSE: To analyze the clinical performance of free-breathing and electrocardiogram (ECG)-gated radial quiescent-interval slice-selective (QISS)-MRA compared to CE-CTA and to Cartesian balanced steady-state free precession (bSSFP)-MRA. STUDY TYPE: Prospective. SUBJECTS: Thirty patients with confirmed APE and 30 healthy volunteers (HVs). FIELD STRENGTH/SEQUENCE: Radial QISS- and bSSFP-MRA at 1.5T. ASSESSMENT: Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed to compare the pulmonary imaging quality between MRA methods. The pulmonary arterial tree was divided into 25 branches and an ordinal scoring system was used to assess the image quality of each pulmonary branch. The clinical performance of the two MRA techniques in accurately assessing APE was evaluated with respect to CE-CTA as the clinical reference standard. STATISTICAL TESTS: Wilcoxon signed-rank and Spearman's correlation tests were performed. Sensitivity and specificity of the MRA techniques were determined using CE-CTA as the clinical reference standard. RESULTS: Thrombus-mimicking artifacts appeared more frequently in lobar and peripheral arteries of patients with Cartesian bSSFP than with radial QISS-MRA (pulmonary trunk: 12.2% vs. 14.0%, P = 0.64; lobar arteries: 35.6% vs. 22.0%, P = 0.005, peripheral arteries: 74.4% vs. 49.0%, P < 0.001). The relative increases in SNR and of CNR provided by radial QISS-MRA with respect to Cartesian bSSFP-MRA were 30-35% (P-values of SNR/CNR, HVs: 0.09/0.09, patients: 0.03/0.02). The image quality of pulmonary arterial branches was considered good to excellent in 77.2% of patients with radial QISS-MRA and in 43.2% with Cartesian bSSFP-MRA (P < 0.0001). The clinical performance of radial QISS-MRA was higher than Cartesian bSSFP-MRA for grading embolism, with a total sensitivity of 86.0% vs. 80.6% and a specificity of 93.3% vs. 84.0%, respectively. DATA CONCLUSION: Radial QISS-MRA is a reliable and safe non-CE angiographic technique with promising clinical potential compared to Cartesian bSSFP-MRA and as an alternative technique to CE-CTA for the diagnosis of APE. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Angiografia por Ressonância Magnética , Embolia Pulmonar , Angiografia por Tomografia Computadorizada , Meios de Contraste , Humanos , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
4.
J Med Case Rep ; 18(1): 196, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38643176

RESUMO

INTRODUCTION: The management of a pregnancy in a bicornuate uterus is particularly challenging. A bicornuate uterus is a rare occurrence and a twin pregnancy in a bicornuate uterus even more rare. These pregnancies call for intensive diagnostic investigation and interdisciplinary care. CASE PRESENTATION: We report on a 27-year-old European woman patient (gravida I, para 0) with a simultaneous pregnancy in each cavity of a bicornuate bicollis uterus after embryo transfer. The condition was confirmed by hysteroscopy and laparoscopy. Several unsuccessful in vitro fertilization (IVF) attempts had been performed earlier before embryo transfer in each cornus. After a physiological course of pregnancy with differential screening at 12 + 6 weeks and 22 + 0 weeks of gestation, the patient presented with therapy-resistant contractions at 27 + 2 weeks. This culminated in the uncomplicated spontaneous delivery of the leading fetus and delayed spontaneous delivery of the second fetus. DISCUSSION: Only 16 cases of twin pregnancy in a bicornuate unicollis uterus have been reported worldwide and only 6 in a bicornuate bicollis uterus. The principal risks in such pregnancies are preterm labor, intrauterine growth restriction, malpresentation and preeclampsia. These typical risk factors of a twin pregnancy are greatly potentiated in the above mentioned setting. CONCLUSION: A twin pregnancy in the presence of a uterine malformation is rare and difficult to manage. These rare cases must be collected and reported in order to work out algorithms of monitoring and therapy as well as issue appropriate recommendations for their management.


Assuntos
Útero Bicorno , Gravidez , Feminino , Recém-Nascido , Humanos , Adulto , Gravidez de Gêmeos , Útero/diagnóstico por imagem , Útero/anormalidades , Gêmeos , Histeroscopia
6.
J Clin Med ; 12(4)2023 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-36836170

RESUMO

(1) Background: Preoperative imaging of the lower leg arteries is essential for planning fibular grafting. The aim of this study was to evaluate the feasibility and clinical value of non-contrast-enhanced (CE) Quiescent-Interval Slice-Selective (QISS)-magnetic resonance angiography (MRA) for reliably visualizing the anatomy and patency of the lower leg arteries and for preoperatively determining the presence, number, and location of fibular perforators. (2) Methods: The anatomy and stenoses of the lower leg arteries and the presence, number, and location of fibular perforators were determined in fifty patients with oral and maxillofacial tumors. Postoperative outcomes of patients after fibula grafting were correlated with preoperative imaging, demographic, and clinical parameters. (3) Results: A regular three-vessel supply was present in 87% of the 100 legs. QISS-MRA was able to accurately assign the branching pattern in patients with aberrant anatomy. Fibular perforators were found in 87% of legs. More than 94% of the lower leg arteries had no relevant stenoses. Fibular grafting was performed in 50% of patients with a 92% success rate. (4) Conclusions: QISS-MRA has the potential to be used as a preoperative non-CE MRA technique for the diagnosis and detection of anatomic variants of lower leg arteries and their pathologies, as well as for the assessment of fibular perforators.

7.
Magn Reson Imaging ; 78: 58-68, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33582146

RESUMO

PURPOSE: Non-contrast-enhanced (CE) magnetic resonance angiography (MRA) techniques are of considerable interest for diagnosing vascular diseases in the upper extremities owing to the possibility of repeated examinations, sufficient coverage of the measurement volume, and because possible side effects of administering iodine- or gadolinium-based contrast agents and radiation exposure can be avoided. The aim of this study was to investigate the feasibility of an optimized electrocardiogram (ECG) triggered Cartesian quiescent interval slice selective (QISS) technique for MRA of hand arteries. MATERIAL AND METHODS: Both hands of 20 healthy volunteers (HVs) were examined using an optimized QISS-MRA pulse sequence at 1.5 Tesla. The wrist and hand arterial trees were divided into 36 segments. Cross-sectional areas (CSA) of all arterial segments were measured. For the technical evaluation of the pulse sequence, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed and six imaging artifacts were graded. Two experienced observers used an ordinal scoring system to assess the image quality of each arterial segment. Interobserver agreement was determined. RESULTS: The median CSA was 7.3 mm2 in the ulnar and radial artery, 3.2 mm2 in the four common digital arteries, and 1.5 mm2 in five proper digital arteries. The median SNR and CNR of the third common proper arteries were 45.9 and 20.3, respectively. None of the arterial segments were contaminated by venous enhancement. The image quality of arterial segments for both hands was considered as diagnostic in 87.2% of all 1440 segments. An interobserver agreement of 0.67 for both hands was determined for image quality of arterial segments using a five-grade scoring system. Optimized QISS-MRA allows as the first MRA technique the classification of superficial palmar arch (SPA) and deep palmar arch (DPA) variants. 5 new SPA and 6 new DPA variants could be classified using QISS-MRA in comparison with previous studies using CE computed tomography angiography and using fixed cadaver hands. CONCLUSIONS: By using this optimized 2D Cartesian QISS-MRA protocol, contrast agent-free angiography of the wrist and hand arteries provided a high in-plane spatial resolution and an excellent visualization of small digital arteries.


Assuntos
Artérias/diagnóstico por imagem , Meios de Contraste , Mãos/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Punho/diagnóstico por imagem , Adulto , Idoso , Feminino , Mãos/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Punho/irrigação sanguínea
8.
Clin Neuroradiol ; 31(4): 911-920, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33688981

RESUMO

PURPOSE: Recurrent stroke is considered to increase the incidence of severe disability and death. For correct risk assessment and patient management it is essential to identify the origin of stroke at an early stage. Transthoracic echocardiography (TTE) is the initial standard of care for evaluating patients in whom a cardioembolic source of stroke (CES) is suspected but its diagnostic capability is limited. Transesophageal echocardiography (TEE) is considered as gold standard; however, this approach is time consuming, semi-invasive and not always feasible. We hypothesized that adding a delayed-phase cardiac computed tomography (cCT) to initial multimodal CT might represent a valid alternative to routine clinical echocardiographic work-up. MATERIAL AND METHODS: Patients with suspected acute cardioembolic stroke verified by initial multimodal CT and subsequently examined with cCT were included. The cCT was evaluated for presence of major CES and compared to routine clinical echocardiographic work-up. RESULTS: In all, 102 patients with suspected acute CES underwent cCT. Among them 60 patients underwent routine work-up with echocardiography (50 TTE and only 10 TEE). By cCT 10/60 (16.7%) major CES were detected but only 4 (6.7%) were identified by echocardiography. All CES observed by echocardiography were also detected by cCT. In 8 of 36 patients in whom echocardiography was not performed cCT also revealed a major CES. CONCLUSION: These preliminary results show the potential diagnostic yield of delayed-phase cCT to detect major CES and therefore could accelerate decision-making to prevent recurrence stroke. To confirm these results larger studies with TEE as the reference standard and also compared to TTE would be necessary.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Humanos , Estudo de Prova de Conceito , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Tomografia Computadorizada por Raios X
9.
Magn Reson Imaging ; 65: 155-165, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31715249

RESUMO

PURPOSE: The aim of this study was to investigate the diagnostic value of myocardial deformation analysis based on the 17-segment heart model using non-contrast enhanced (CE) 2D tissue feature tracking (2D-FT) technique. MATERIAL AND METHODS: Seventy patients with suspected myocarditis underwent a cardiovascular magnetic resonance (CMR) examination at 1.5 Tesla. A contrast-agent-free part of this CMR protocol was additionally performed in forty healthy volunteers (HV). Besides standard CMR data sets, 2D-FT derived segmental and global longitudinal, radial, and circumferential deformation parameters were analyzed. The 2D-FT results were compared to the combined findings from CMR imaging and endomyocardial biopsy (EMB). RESULTS: Patients were assigned to three groups depending on their ejection fraction (EF) (<40%, 40-55%, ≥55%). Compared to HV, impaired EF (<55%) was significantly correlated to reduced segmental and global strain and strain rate values. The circumferential deformation analysis was more sensitive to myocardial changes than longitudinal and radial analysis. The segmental strain/strain rate had an accuracy of 84.3%/70.0% for the diagnosis of an acute myocarditis, stated by EMB and CMR in 42 of 70 patients. In patients with preserved EF, acute myocarditis could be ruled out using only segmental strain analysis with a negative predictive value of 87.5%. CONCLUSION: In patients with suspected myocarditis, the deformation analysis based on the 17-segment heart model provides valuable information about functional myocardial inhomogeneity. This quantitative approach could be used in addition to the clinical standard CMR protocol and represents a promising tool in the framework of a prospective automatized multiparametric CMR imaging analysis.


Assuntos
Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Miocardite/diagnóstico por imagem , Adulto , Biópsia , Feminino , Voluntários Saudáveis , Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/patologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA