Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Br J Anaesth ; 108(4): 690-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22258205

RESUMO

BACKGROUND: New ventilators have simplified the use of supraglottic superimposed high-frequency jet ventilation (SHFJV(SG)), but it has not been systematically compared with other modes of jet ventilation (JV) in humans. We sought to investigate whether SHFJV(SG) would provide more effective ventilation compared with single-frequency JV techniques. METHODS: A total of 16 patients undergoing minor laryngeal surgery under general anaesthesia were included. In each patient, four different JV techniques were applied in random order for 10-min periods: SHFJV(SG), supraglottic normal frequency (NFJV(SG)), supraglottic high frequency (HFJV(SG)), and infraglottic high-frequency jet ventilation (HFJV(IG)). Chest wall volume variations were continuously measured with opto-electronic plethysmography (OEP), intratracheal pressure was recorded and blood gases were measured. RESULTS: Chest wall volumes were normalized to NFJV(SG) end-expiratory level. The increase in end-expiratory chest wall volume (EEV(CW)) was 239 (196) ml during SHFJV(SG) (P<0.05 compared with NFJV(SG)). EEV(CW) was 148 (145) and 44 (106) ml during HFJV(SG) and HFJV(IG), respectively (P<0.05 compared with SHFJV(SG)). Tidal volume (V(T)) during SHFJV(SG) was 269 (149) ml. V(T) was 229 (169) ml (P=1.00 compared with SHFJV(SG)), 145 (50) ml (P<0.05), and 110 (33) ml (P<0.01) during NFJV(SG), HFJV(SG), and HFJV(IG), respectively. Intratracheal pressures corresponded well to changes in both EEV(CW) and V(T). All JV modes resulted in adequate oxygenation. However, was lowest during HFJV(SG) [4.3 (1.3) kPa; P<0.01 compared with SHFJV(SG)]. CONCLUSION: SHFJV(SG) was associated with increased EEV(CW) and V(T) compared with the three other investigated JV modes. All four modes provided adequate ventilation and oxygenation, and thus can be used for uncomplicated laryngeal surgery in healthy patients with limited airway obstruction.


Assuntos
Ventilação em Jatos de Alta Frequência/métodos , Laringoscopia/métodos , Laringe/cirurgia , Adulto , Idoso , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/métodos , Volume de Ventilação Pulmonar
2.
Space Sci Rev ; 217(3): 48, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34776548

RESUMO

NASA's Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.

3.
Rev Sci Instrum ; 79(4): 043302, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18447523

RESUMO

A fusion-product source, utilizing a 150 kV Cockraft-Walton linear accelerator, has been refurbished to provide a reliable nuclear diagnostic development tool to the national inertial confinement fusion (ICF) research program. The accelerator is capable of routinely generating DD reaction rates at approximately 10(7)/s when using a 150 kV, 150 microA deuterium (D) beam onto an erbium (Er) or titanium (Ti) target doped with D, and D(3)He reaction rates at approximately 5 x 10(5)/s when using a using a 120 kV, approximately 100 microA D beam onto a Er or Ti target doped with (3)He. The new accelerator is currently being used in a number of projects related to the national ICF program at the OMEGA Laser Fusion Facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)], which includes the wedge range filter charged-particle spectrometry program [F. H. Seguin et al., Rev. Sci Instrum. 75, 3520 (2004)] and the magnetic recoil neutron spectrometer [J. A. Frenje et al., Rev. Sci. Instrum. 72, 854 (2001)].

4.
QJM ; 98(8): 575-9, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15983022

RESUMO

BACKGROUND: Fractures and atherosclerosis are common in patients with renal failure; this may be due to hyperhomocysteinemia. AIM: To examine the relationships between fractures, vascular calcification and homocysteine levels in haemodialysis patients. DESIGN: Cross-sectional survey. METHODS: We enrolled 37 men and 15 women who had been on haemodialysis for at least 1 year. We identified prevalent spine fractures by radiographs. Non-spine fractures were identified by self-report and confirmed by review of radiographs or radiology reports. We classified the presence and severity of lumbar aortic calcifications with lateral lumbar radiographs. We measured serum homocysteine in all subjects within 30 days of study entry. RESULTS: After adjusting for age and weight, increased levels of homocysteine were associated with an increased risk fracture (OR per mmol/l increase in homocysteine 1.6, 95%CI 1.2-2.0), as was the presence of aortic calcification (OR 1.6, 95%CI 1.2-2.1). Homocysteine and lumbar aortic calcification were highly correlated (r = 0.86). DISCUSSION: Hyperhomocysteinaemia may explain the relationship between fractures and atherosclerosis in patients with renal failure.


Assuntos
Calcinose/etiologia , Fraturas Ósseas/etiologia , Homocisteína/sangue , Hiper-Homocisteinemia/complicações , Falência Renal Crônica/complicações , Doenças Vasculares/etiologia , Idoso , Estudos Transversais , Feminino , Humanos , Hiper-Homocisteinemia/sangue , Hiper-Homocisteinemia/patologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Diálise Renal , Fraturas da Coluna Vertebral/etiologia
5.
Osteoporos Int ; 17(9): 1390-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16799753

RESUMO

INTRODUCTION: Fractures are extremely common among hemodialysis (HD) patients. METHODS: To assess if bone mineral density (BMD) and/or tests of muscle strength were associated with fractures, we studied 37 men and 15 women, 50 years and older, on HD for at least 1 year. We excluded subjects with prior renal transplants and women taking hormone replacement therapy. We inquired about low-trauma fractures since starting dialysis. Subjects underwent BMD testing with a Lunar DPX-L densitometer. Tests of muscle strength included: timed up and go (TUG), 6-min walk, functional reach, and grip strength. Lateral and thoracic radiographs of the spine were obtained and reviewed for prevalent vertebral fractures. We used logistic regression to examine associations between fracture (prevalent vertebral, self-reported low trauma since starting dialysis and/or both) and BMD, and fracture and muscle-strength tests. Analyses were adjusted for age, weight, and gender. RESULTS: Mean age was 66+/-9.0 years, mean weight was 72.9+/-15.2 kg, and most (35 of 52) participants were Caucasian. Average duration of dialysis was 40.2 (interquartile range: 24-61.2) months. The most common cause of renal failure was diabetes (16 subjects). There were no differences by gender or fracture. Of the 52 subjects, 27 had either a vertebral fracture or low trauma fracture. There was no association between fractures, hip or spine BMD, or grip strength. In contrast, greater functional reach [odds ratio (OR) per standard deviation (SD) increase: 0.29; 95% CI: 0.13-0.69), quicker TUG (OR per SD decrease: 0.14; 95% CI: 0.11-0.23), and a greater distance walked in 6 min (OR per SD increase: 0.10; 95% CI: 0.03-0.36) were all associated with a reduced risk of fracture. CONCLUSIONS: Impaired neuromuscular function is associated with fracture in hemodialysis patients.


Assuntos
Fraturas Ósseas/etiologia , Força Muscular , Diálise Renal/efeitos adversos , Absorciometria de Fóton , Idoso , Densidade Óssea , Feminino , Colo do Fêmur/fisiopatologia , Fraturas Ósseas/fisiopatologia , Força da Mão , Articulação do Quadril/fisiopatologia , Humanos , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiopatologia , Osteoporose/complicações , Osteoporose/fisiopatologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA