Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Europace ; 25(3): 1100-1109, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36660771

RESUMO

AIMS: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads with a dwell time of >10 years (Group A) vs. younger leads (Group B) using mechanical extraction systems. METHODS AND RESULTS: Between October 2011 and July 2022, we performed TLE in 318 patients. Forty-six (14.4%) extracted ICD leads in 46 (14.5%) patients that had been implanted for >10 years. The median dwell time of all extracted ICD leads was 5.9 years. Cardiovascular implantable electronic device-related infection was an indication for TLE in 31.8% of patients. Complete ICD leads removal and complete procedural success in both groups were similar (95.7% in Group A vs. 99.6% in Group B, P = 0.056% and 95.6% in Group A vs. 99.6% in Group B, P = 0.056, respectively). We did not find a significant difference between major and minor complication rates in both groups (6.5% in Group A vs. 1.5% in Group B and 2.2% in Group A vs. 1.8% in Group B, P = 0.082, respectively). One death associated with the TLE procedure was recorded in Group B. CONCLUSION: The TLE procedures involving the extraction of old ICD leads were effective and safe. The outcomes of ICD lead removal with a dwell time of >10 years did not differ significantly compared with younger ICD leads. However, extraction of older ICD leads required more frequent necessity for utilizing multiple extraction tools, more experience and versatility of the operator, and increased surgery costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Resultado do Tratamento , Estudos Retrospectivos
2.
Echocardiography ; 40(10): 1068-1078, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632153

RESUMO

BACKGROUND: His bundle pacing (HBP) has proved to be a valuable alternative enabling the physiological activation of cardiac contraction in cardiac resynchronization therapy (CRT). At present, however, little is known about the optimal method of programming of the His bundle-paced CRT systems in terms of achieving the best cardiac output. AIM: The aim of this study was to evaluate the impact of cardiac resynchronization therapy with conduction system pacing (CRT+CSP) on echo-based hemodynamic parameters in the early post-operative measurements. METHODS: The study enrollment criteria included: permanent atrial fibrillation, heart failure and bundle branch block. All patients underwent implantation of CRT + HBP. During the post-operative phase, we aimed to optimize HOT-CRT settings in order to achieve the greatest cardiac output assessed by complex echocardiographic measurements. RESULTS: The study included 21 patients, mean age 71.2 (6.3) years, predominantly men (71.4%) with non-ischemic cardiomyopathy 62%. All patients had heart failure with NYHA functional class III and IV (81%). Mean left ventricular ejection fraction was 27.5 (9.7%). The mean duration of the QRS complex was 148.8 ms. The effects of resynchronization pacing: HBP alone, HBP with left ventricular pacing, HBP with biventricular pacing (BiV) and BiV without HBP ​​were analyzed consecutively. HBP combined with left ventricular pacing demonstrated the best hemodynamic response. CONCLUSION: His bundle pacing coupled with LV pacing proved to be the most advantageous pacing program setting with regard to cardiac output. Moreover, it performed better than biventricular pacing and significantly better than RV pacing.

3.
Pacing Clin Electrophysiol ; 44(1): 148-150, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33165971

RESUMO

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. We present an interesting ECG with a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with atrial fibrillation, pacing beats, ventricular ectopic beats, and couple of ventricular beats. This report shows unexceptional occurrence of tricky ECG finding in patient with Biotronik ICDs.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Impedância Elétrica , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária
4.
Pol Merkur Lekarski ; 48(285): 204-208, 2020 Jun 17.
Artigo em Polonês | MEDLINE | ID: mdl-32564048

RESUMO

Atrial flutter (AFL) is one of the most common arrhythmias present in clinical practice, both for the GPs and cardiologist practice. After atrial fibrillation (AF) is second the most common supraventricular arrhythmia. This usually occurs along the cavo-tricuspid isthmus of the right atrium though atrial flutter can originate from the left atrium as well. As AFL is rarely susceptible to pharmacotherapy, that is why, the guidelines of the European and American Cardiology Societies suggest non-pharmacological treatment - an ablation, which is a "gold standard". Due to the reentrant nature of atrial flutter, it is often possible to ablate the circuit that causes atrial flutter with radiofrequency catheter ablation. Catheter ablation is considered to be a first-line treatment method for many people with typical atrial flutter due to its high rate of success (>90%) and low incidence of complications. This is done in the cardiac electrophysiology lab by causing a ridge of scar tissue in the cavo-tricuspid isthmus that crosses the path of the circuit that causes atrial flutter. Eliminating conduction through the isthmus prevents reentry, and if successful, prevents the recurrence of the atrial flutter. Atrial fibrillation often occurs after catheter ablation for atrial flutter. We present an up to date overview of the most important information about AFL based on the available literature.


Assuntos
Fibrilação Atrial , Flutter Atrial , Cardiologia , Ablação por Cateter , Flutter Atrial/diagnóstico , Flutter Atrial/terapia , Eletrocardiografia , Átrios do Coração , Humanos
5.
J Cardiovasc Electrophysiol ; 30(8): 1325-1329, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31187551

RESUMO

INTRODUCTION: To deliver accurate morphological descriptions of the Vieussens valve (VV) and to investigate whether this structure could be visualized using standard contrast-enhanced electrocardiogram-gated multislice computed tomography (MSCT). METHODS: A total of 145 human autopsied hearts and 114 cardiac MSCT scans were examined. RESULTS: The VV was observed in both study groups, however, the detection rate was significantly worse in the MSCT examination (18.4% in MSCT vs 62.1% in cadavers, P < .0001). The VV height was larger in MSCT patients (2.8 ± 1.2 vs 5.4 ± 1.7 mm; P < .0001). No significant difference was found in the measured distance between the VV and the coronary sinus ostium between the two separate subgroups (27.3 ± 9.5 vs 24.4 ± 5.8 mm; P = .18). In autopsied material the most frequent valve location was the anterior wall of the coronary sinus (43.3%); the same was observed in MSCT scans (71.4%). CONCLUSION: The VV is a common heart structure, present in over 60% of humans, located mainly on the anterior and superior circuit of the coronary sinus, with relatively high morphological variability. Large VVs, which pose a significant obstacle in catheterization procedures, may be visualized using standard-protocol contrast-enhanced cardiac MSCT.


Assuntos
Vasos Coronários/anatomia & histologia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Válvulas Venosas/anatomia & histologia , Válvulas Venosas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Cadáver , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Adulto Jovem
6.
Pacing Clin Electrophysiol ; 42(3): 374-380, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30659629

RESUMO

AIMS: A novel therapy offering cardiac resynchronization therapy (CRT) with an additional lead placed in His bundle has been reported in a few case reports and case series as improving the hemodynamical and clinical condition of patients with permanent atrial fibrillation (AF) in whom other therapeutic methods have not been successful. METHODS: Fourteen consecutive patients with permanent AF, heart failure (HF), bundle branch block (BBB) with QRS complex width >130 ms, and impaired left ventricular ejection fraction (LVEF) underwent implantation of implantable cardioverter defibrillator (ICD)/CRT systems with His bundle pacing (HBP). During the follow-up, we assessed the efficacy of ICD/CRT systems with HBP in HF treatment. RESULTS: The study cohort consisted of 14 patients with the mean age of 67.35 ± 10 years. The mean duration of QRS was 159.2 ± 28.6 ms, mean LVEF was 24.36 ± 10.7%, and mean follow-up duration was 14.4 months. One patient died due to HF aggravation during the follow-up. In the remaining 13 patients, the mean LVEF significantly improved from 24% to 38%, P = 0.0015. The left ventricular end-diastolic dimension decreased from 72 mm to 59 mm, P < 0.001; left ventricular end-systolic dimension decreased from 59 mm to 47 mm, P = 0.0026. The mean QRS duration shortened from 159 ms to 128 ms, P = 0.016. The mean percentage of HBP reached 97%. As a result, 92.3% of patients demonstrated significant improvement in the New York Heart Association functional class, P < 0.001. CONCLUSION: The use of atrial channel for HBP, choice of optimal ICD/CRT pacing configuration, and optimization of pharmacological therapy resulted in a substantial narrowing of QRS width and clinical improvement in left ventricular mechanical function during the follow-up.


Assuntos
Fibrilação Atrial/terapia , Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Feminino , Humanos , Masculino
7.
Pacing Clin Electrophysiol ; 42(7): 998-1005, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045256

RESUMO

OBJECTIVE: To analyze and compare the effectiveness and safety of transvenous lead extraction (TLE) with mechanical systems of pacing leads older than 20 years (group A) versus younger leads (group B). METHODS: We performed TLE of 591 pacing leads in 377 patients. Fifty (8.5%) leads in 43 (11.4%) patients were implanted for equal to or more than 20 years. The mean dwell time of all extracted leads was 8.9 years (range, 0.1-36.0). Infection related to cardiovascular implantable electronic device was an indication for TLE in 18.3% of patients. RESULTS: Complete lead removal and complete procedural success rates were similar between both groups (94.7% in group A vs 97.1% in group B, P = 0.445, and 90.7% in group A vs 95.8% in group B, P = 0.329, respectively). Incomplete lead removal in group A was observed only in leads older than 20 years. Removal of leads in group A was associated with significantly longer fluoroscopy time compared with group B (4.6 vs 1.9 minutes, P < 0.001). We did not find a significant difference in major and minor complication rates between groups (2.3% in group A vs 0.9% in group B and 2.3% in group A vs 2.2% in group B, P = 0.687, respectively). There were no deaths associated with the TLE procedure within 30 days after the procedure in either group. CONCLUSION: This study shows that TLE of leads older than 20 years conducted at an experienced center seems to be comparably safe and effective as extraction of younger leads but requires longer fluoroscopy time.


Assuntos
Remoção de Dispositivo/métodos , Eletrodos Implantados , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Falha de Equipamento , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Segurança do Paciente , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Fatores de Tempo
8.
Ann Noninvasive Electrocardiol ; 24(4): e12648, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30896054

RESUMO

The electrocardiogram (ECG) interpretation in patients with implantable pacemaker is often a perplexing problem. The difficulty in the device evaluation increases in the presence of novel timing cycles and additional functions. Authors describe a special function frequently encountered in Medtronic dual-chamber pacemakers and implantable cardioverter-defibrillator devices called managed ventricular pacing (MVP) and demonstrate its performance in the patient with undersensing episodes in ventricular channel. Intermittent ventricular undersensing in the device with MVP feature turned on caused repetitive mode switches between AAI and DDD mode. This report shows unexceptional occurrence of tricky ECG findings in patient with Medtronic dual-chamber device.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Marca-Passo Artificial , Idoso , Feminino , Humanos
9.
Ann Noninvasive Electrocardiol ; 24(2): e12545, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29693306

RESUMO

The electrocardiogram (ECG) interpretation in patients with implantable cardioverter defibrillator (ICD) is often a puzzling problem. The difficulty of the device function evaluation further increases in the presence of unfamiliar timing cycles and additional functions. Authors present a special function of a Biotronik ICD devices called the thoracic impedance monitoring, and demonstrate its behavior in a patient with sinus rhythm, ventricular ectopic beats, and ventricular tachycardia episode. This report shows unexceptional occurrence of tricky ECG finding in patient with Biotronik ICD.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Segurança de Equipamentos , Taquicardia Ventricular/diagnóstico por imagem , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial/métodos , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
10.
Pol Merkur Lekarski ; 46(274): 187-189, 2019 Apr 29.
Artigo em Polonês | MEDLINE | ID: mdl-31099767

RESUMO

Cardiovascular implantable electronic devices (CIED) encompass permanent cardiac pacemakers (PM) and implantable cardioverterdefibrillators (ICD). CIED play an important role in treatment of cardiac arrhythmias, including significant bradyarrhythmias and tachyarrhythmias. The conventional right ventricular endocardial leads as well as right ventricular pacing may increase valvular defects (especially dysfunction of tricuspid and mitral valve), cause adverse cardiac remodelling and lead to a decrease in left ventricular ejection fraction. These changes may be due to mechanical damage to the leaflets or other structures of the tricuspid apparatus, such as the annulus, papillary muscles or chordae tendineae. In addition, the endocardial lead passing through the tricuspid valve may adhere to it and exacerbate the inflammatory processes and fibrosis of its leaflets. On the other hand, right ventricular pacing leads to electromechanical dyssynchrony of the cardiac muscle. New forms of CIED therapy such as leadless pacemakers, His bundle pacing, synchronized left ventricular pacing or biventricular pacing may reduce some adverse changes induced by the right ventricular pacing with the use of conventional cardiac pacemakers. Similarly, subcutaneous cardioverter-defibrillators, despite limitations, may prevent some complications associated with traditional implantable cardioverterdefibrillator lead.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas , Estimulação Cardíaca Artificial , Cardioversão Elétrica , Humanos
11.
Pol Merkur Lekarski ; 47(280): 153-156, 2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31760399

RESUMO

Cardiac arrhythmias are common in patients with various types of muscular dystrophies. The pathophysiological mechanisms of arrhythmias are complex and related to direct involvement of the conduction system and to the development of cardiomyopathy. The occurrence of atrio-ventricular conduction abnormalities and ventricular arrhythmias are associated with increased risk of sudden cardiac death. The threshold for device therapy ( cardiac pacemaker, implantable cardioverter defibrillator) is relatively low according to current guidelines due to the risk of rapid progression of the disease. Atrial arrhythmias carry high risk of stroke and anticoagulation should be considered even in young patients without coexisting risk factors for stroke as estimated by the CHA2DS2-VASc score. Patients with muscular dystrophies should be under regular cardiology follow up even in the absence of symptoms. Early detection of cardiac involvement is crucial. The management of patients with muscular dystrophies requires disease-specific and multidisciplinary approach due to the multi-organ involvement.


Assuntos
Arritmias Cardíacas , Desfibriladores Implantáveis , Distrofias Musculares , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca , Sistema de Condução Cardíaco , Humanos , Distrofias Musculares/complicações
12.
Pol Merkur Lekarski ; 47(278): 65-66, 2019 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-31473754

RESUMO

A CASE REPORT: A 65-year-old male patient underwent left-sided placement of implantable cardioverter-defibrillator. At three years after implantation he emerged complaining on left upper limb and left-sided neck edema. Left brachicephalic vein thrombosis due to device leads was recognized. The attending cardiologist referred the patient to university radiology department for venous angioplasty but the patient was admitted to cardiology department. Coronary angiography was performed due to suspicion of ischemic heart disease. However, it showed the presence of foreign body in cardiovascular system - completely intravascular round-tipped guide wire used in Seldinger technique for insertion of the endocardial lead abandoned in left subclavian vein and reaching to superior vena cava. Patient was transferred to third-degree reference lead extraction center. The procedure was performed under general anesthesia in hybrid operating room. Via femoral vein access we introduced Needle's Eye Snare and grasped the guide wire. Then, using polytetrafluoroethylene sheath the tissue adhesions were dissected and the complete guide wire was retrieved.


Assuntos
Desfibriladores Implantáveis , Migração de Corpo Estranho , Síndrome da Veia Cava Superior , Idoso , Desfibriladores Implantáveis/efeitos adversos , Humanos , Masculino , Síndrome da Veia Cava Superior/etiologia , Veia Cava Superior
13.
Pacing Clin Electrophysiol ; 41(9): 1217-1223, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30055057

RESUMO

INTRODUCTION: We evaluated the influences of selected factors on electrical lead failure (ELF) occurrence in patients referred for transvenous lead extraction (TLE) procedures. METHODS AND RESULTS: The study cohort consisted of 432 patients referred for TLE procedures due to various indications (42 - lead-dependent infective endocarditis, 47 - pocket infection, 343 - noninfectious indications) with a total of 804 endocardial leads. In the analyzed group, there were 192 patients with ELF, denoted as group ELF(+) (200 malfunctioning endocardial leads). The percentage of women was higher in the ELF(+) group than in the ELF(-) group (42.7% vs 30.0%; P  =  0.006). The ELF(+) patients had more endocardial leads implanted via subclavian vein puncture (80.0% vs 72.4%; P  =  0.032), had more indwelling leads in the cardiovascular system (1.94 vs 1.8; P  =  0.03), were older (68.9 vs 66.0 years old; P  =  0.028), and had better left ventricular ejection fractions than the ELF(-) patients (48.0% vs 40.7%; P < 0.001). The time interval to ELF occurrence was significantly longer for pacing leads than for cardioverter-defibrillator leads (95.7 vs 65.7 months; P  =  0.016). The most important factor associated with ELF was subclavian vein puncture, increasing the risk of ELF occurrence by 2.5-fold and 2.7-fold in the univariate and multivariate Cox proportional hazards regression models, respectively. The presence of a cardioverter-defibrillator lead increased the risk of ELF by 1.9-fold and 2.7-fold in the univariate and multivariate models, respectively. CONCLUSION: The most significant factors predisposing patients to ELF are the lead implantation approach and the presence of a cardioverter-defibrillator lead.


Assuntos
Remoção de Dispositivo , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Endocardite/etiologia , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Sistema de Registros , Fatores de Risco
14.
Artigo em Inglês | MEDLINE | ID: mdl-28593660

RESUMO

The electrocardiogram (ECG) interpretation in patients with cardiac resynchronization therapy (CRT) is often a perplexing problem. The difficulty in the device evaluation increases in the presence of unfamiliar timing cycles and a lead dysfunction. Authors describe a special function of a Biotronik CRT devices called the left ventricle T-wave protection (LVTP), and demonstrate its behavior in a patient with left ventricular (LV) lead failure. This report shows that sometimes it might be difficult to understand the loss of resynchronization in 12-lead ECG when LVTP feature is on, and a malfunction of left ventricular lead sensing occurs.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Falha de Equipamento , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Algoritmos , Diagnóstico Diferencial , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
15.
J Electrocardiol ; 51(3): 487-489, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29779529

RESUMO

The electrocardiogram (ECG) interpretation in patients with cardiac resynchronization therapy (CRT) may be challenging. The difficulty increases if not well-known pacemaker algorithm is turned on. We show a T-wave protection algorithm (LVTP) in a patient with CRT. Accelerated sinus rhythm and intermittent oversensing in left ventricular channel resulted in loss of CRT pacing. The restoration of biventricular pacing occurred when atrial rate decreased. We provide detailed descriptions of the electrocardiogram and intracardiac electrogram. LVTP may confuse ECG examination interpretation, especially in patients with accelerated atrial rhythm and oversensing in left ventricular channel.


Assuntos
Algoritmos , Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Morte Súbita Cardíaca/prevenção & controle , Análise de Falha de Equipamento , Insuficiência Cardíaca/terapia , Idoso , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino
16.
J Electrocardiol ; 51(3): 405-408, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29525386

RESUMO

CRT is a therapeutic option for patients with heart failure, sinus rhythm, prolonged QRS complex duration and reduced ejection fraction. We present a case of 71-year-old woman with dilated cardiomyopathy, NYHA functional class III and AF. We implanted CRT combined with direct His-bundle pacing. The indication for such a therapy was a left bundle branch block with a QRS complex of 178ms and a left ventricular EF of 15%, left ventricular end-diastolic diameter (LVEDD) of 75mm. After 8months of follow-up the LVEDD was 60mm with EF 35-40%.


Assuntos
Fibrilação Atrial/terapia , Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatia Dilatada/terapia , Eletrocardiografia , Insuficiência Cardíaca/terapia , Idoso , Fibrilação Atrial/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Cardiomiopatia Dilatada/fisiopatologia , Angiografia Coronária , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Resultado do Tratamento
17.
Pol Merkur Lekarski ; 44(264): 267-271, 2018 Jun 27.
Artigo em Polonês | MEDLINE | ID: mdl-30057392

RESUMO

Cardiac arrhythmias most often arise in the mechanism of disorders of impulse formation (automaticity, triggered activity), disorders of impulse conduction (reentry, block) or a combination of both. Atrial fibrillation (AF) most often occurs in the course of mitral stenosis and/or mitral regurgitation, rarely in the defects of the aortic valve. Ventricular arrhythmias may be associated with the most valvular heart diseases. Among the disturbances of automatism and conduction in valvular heart diseases, the most common are atrioventricular blocks (AV blocks) and intraventricular blocks. In addition to defect correction and pharmacological treatment, non-pharmacological treatment of cardiac arrhythmias (transcatheter ablative techniques, permanent pacemakers, implantable cardioverter-defibrillators, implantable cardiac resynchronization devices) plays a significant role in the treatment. It is important for the practitioner to understand about the mechanisms of arrhythmia and nonpharmacological treatment in patients with acquired valvular heart diseases.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/métodos , Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Pol Merkur Lekarski ; 44(259): 23-25, 2018 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-29374419

RESUMO

A man with non-ischemic cardiomyopathy, EF 22%, permanent AF and ICD was admitted for elective device replacement. The need for the optimization of the ventricular rate and avoidance of right ventricular pacing made it necessary to up-grade the existing pacing system using direct His bundle pacing and dual chamber ICD. This enabled the regularization of ventricular rate, avoiding the RV pacing and optimize the beta-blocker dose. The one month follow-up already showed reduction in left ventricle diameter, improvement in ejection fraction, NYHA class decrease to II. The His bundle pacing enabled the optimal treatment of the patient resulting in excellent clinical improvement.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Fibrilação Atrial/terapia , Cardiomiopatias/complicações , Desfibriladores Implantáveis , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Masculino , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-28044401

RESUMO

The 24-hr electrocardiogram (ECG) interpretation in patients with double-chamber pacemakers may be challenging. The difficulty increases if not well-known pacemaker algorithm and device malfunction coexist. We show atrial synchronization pace (ASP) in a patient with ventricular lead damage. We provide detailed description of electrocardiogram and intracardiac electrogram. ASP may confuse 24-hr ECG monitoring interpretation, especially in patients with ventricular lead dysfunction.


Assuntos
Complexos Atriais Prematuros/diagnóstico , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia Ambulatorial/métodos , Marca-Passo Artificial , Disfunção Ventricular/diagnóstico , Idoso de 80 Anos ou mais , Complexos Atriais Prematuros/complicações , Complexos Atriais Prematuros/fisiopatologia , Feminino , Humanos , Disfunção Ventricular/complicações , Disfunção Ventricular/fisiopatologia
20.
Acta Cardiol ; 72(1): 61-67, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28597736

RESUMO

Objective The aim of this study was to evaluate the incidence of venous stenosis and occlusion (VSO) in patients referred for transvenous lead extraction (TLE) with regard to the indications for this treatment and to analyse the influence of VSO on efficacy, complications and technical challenges of TLE procedures. Methods The material consists of 133 consecutive TLE procedure records. The contrast venography examination of the ipsilateral access vein was performed prior to the operation. The whole study population was divided into two subgroups, based on the presence (subgroup I) or absence (subgroup II) of VSO. Results Phlebography was performed in 133 patients with age ranging from 25.7 to 86.1 years, 44 female (33.1%). The VSO was confirmed in 48 (36.1%) patients - subgroup I. Most of the patients were referred to TLE due to non-infectious reasons (100 pts-75.2%). The absence of VSO was observed substantially more frequently in patients with diabetes (P = 0.02). Procedural success rate reached 93.3% in subgroup I and 98.8% in subgroup II (P = 0.1). There was no significant difference in the use of advanced tools and alternative access sites. Conclusion The presence of VSO can be expected in one third of patients referred for lead extraction. There is no association between indication for TLE (infected or noninfected lead extraction) and the incidence of VSO. Diabetes proved to have a protective effect on venous patency in the previously mentioned group. VSO does not influence the effectiveness, safety, and the use of additional tools during TLE procedures.


Assuntos
Veias Braquiocefálicas , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/terapia , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA